30HXC Nominal cooling capacity kw

Similar documents
30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

3 0 H X C A - H P 2

AQUASNAP JUNIOR 30RHV

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

High COP. Water-Cooled Screw Chiller

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RB /30RQ

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30XW-PZE/30XWHPZE-A WATER-COOLED SCREW CHILLERS WATER-SOURCED SCREW HEAT PUMPS PRODUCT SELECTION DATA

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RB /30RQ

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

30KAV Variable Speed Air-cooled Screw Chiller

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

30XW-V/30XWHV. Water-cooled variable-speed screw chillers Water-sourced variable-speed screw heat pumps PRODUCT SELECTION DATA

30RB /30RQ

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB A /30RQ

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30GX HXC Screw Compressor Water-Cooled Liquid Chillers and Air-Cooled Liquid Chillers

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

MISSING 30XB / 30XBP AIR-COOLED FIXED-SPEED SCREW CHILLER PRODUCT SELECTION DATA

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

Water-cooled chillers Remote condenser chillers NEW

30HXC Screw Compressor Water-Cooled Liquid Chillers INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

EWWD MBYN EWLD MBYN Applied systems

30RB Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features. Quiet operation

ARV.

30XW Water-Cooled Liquid Chiller

EPLE Water-cooled chillers Remote condenser chillers. EUW40-200MAXY EUWL40-200MXY Applied systems

Carrier India. Snapshots of Carrier India manufacturing facility

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

30XW Water-Cooled Liquid Chiller

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

kw COOLING kw HEATING

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30XW-V Variable-speed water-cooled screw chiller & heat pump

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

30XAV Variable-Speed Air-Cooled Screw Chillers. product selection data. Low energy consumption. Built in reliability and easy servicing

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Index Features and advantages... 3 General characteristics... 5 Nomenclature... 9 Technical Specifications Sound levels...

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

Installation Instructions

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

30RW/RWA. Water-Cooled/Condenserless Liquid Chillers with Integrated Hydronic Modules PRO-DIALOG INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Water-cooled chillers with High Speed Centrifugal Compressors

XStream Water-cooled screw chillers and Water/Water Heat pumps

Galletti Water chillers and heat pumps catalogue

Compact and silent Scroll compressors All-season operation

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

water-cooled CHILLERS

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only.

Leadership, Innovation, Advanced Technology Synergise Here!

44,9 202,0 kw. technicalcatalogue

kw. technicalcatalogue

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

30XW-V Variable-speed water-cooled screw chiller & heat pump

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Transcription:

WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC Nominal cooling capacity 286-102 kw The 0HXC units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow: - Non-ozone depleting HFC-14a refrigerant - Screw compressors - Fits through a standard door with no disassembly required- - mechanically cleanable evaporators and condensers ll units are equipped with Pro-Dialog Plus control to optimise the efficiency of the refrigerant circuit. 240 C R R I E R 2 0 1 6 / 2 0 1 7

WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC 080-75 Physical data 0HXC 080 090 100 110 120 10 140 155 175 190 200 20 260 285 10 45 75 Cooling Full load performances* Seasonal Efficiency* C1 Nominal capacity kw 287 12 48 75 41 450 510 54 600 652 701 814 899 987 1109 1207 102 C1 EER kw/kw 5.0 4.79 4.82 4.60 4.87 4.72 4.74 4.57 4.68 4.7 4.74 4.74 4.46 4.77 4.76 4.56 4.66 C1 Eurovent Energy Class B B B C B B B C B B B B C B B C B ESEER kw/kw 5.56 5.41 5.1 5.28 5.2 5.21 5.17 4.85 5.0 4.97 5.08 5.06 5.01 5.11 5.49 5.9 5.4 Sound Power Level Standard Unit db() 94 94 94 94 94 97 98 100 101 101 99 101 102 102 10 104 104 Operating weight kg 2274 2279 202 24 2615 2617 2702 2712 08 179 87 4602 4656 4776 5477 555 5721 Dimensions, standard unit Depth mm 2558 2558 2558 2565 275 275 275 275 275 275 90 924 924 924 45 45 45 Length mm 980 980 980 980 980 980 980 980 980 980 1015 1015 1015 1015 1015 1015 1015 Height mm 1800 1800 1800 1850 1816 1816 1816 1816 1940 1940 1980 2060 2060 2060 2112 2112 2112 Refrigerant Compressors R-14a 06N semi-hermetic twin-screw compressor Quantity - Circuit 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 Quantity - Circuit B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 Capacity control Pro-Dialog Plus control No. of control steps 6 6 6 6 6 6 6 6 6 6 8 8 8 8 10 10 10 Evaporator Water connections Shell and tube with internally finned copper tubes Victaulic Inlet/outlet in 4 4 4 5 5 5 5 5 5 5 6 6 6 6 8 8 8 Condenser Water connections Shell and tube with internally finned copper tubes Victaulic Inlet/outlet in 5 5 5 5 5 5 5 5 6 6 6 8 8 8 8 8 8 C1 Cooling mode conditions: Evaporator Water heat exchanger, entering/leaving temperature 12 C/7 C, fouling factor 0 m 2 K/W. Condenser Water heat exchanger, entering/leaving temperature 0 C/5 C, fouling factor 0 m 2 K/W. * In accordance with standard EN14511-:201 Weight shown is a guideline only. The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings. Eurovent certified data Electrical data 0HXC 080 090 100 110 120 10 140 155 175 190 200 20 260 285 10 45 75 Power circuit Nominal power supply (Un)* V-ph-Hz 400--50 ± 10% Control circuit supply The control circuit is supplied via the factory-installed transformer Nominal current drawn* 101 115 127 14 149 168 190 207 226 24 255 294 7 54 99 448 477 Maximum starting current*** 181 206 22 249 267 298 55 82 442 841 978 1027 1200 1129 1184 17 Circuit ** - - - - - - - - - - 712 822 871 1028 844 871 1028 Circuit B** - - - - - - - - - - 605 715 715 856 844 871 1028 * Standard Eurovent conditions: Evaporator entering/leaving water temperature 12 C and 7 C. Condenser entering/leaving water temperature 0 C/5 C. ** Maximum unit operating current at maximum unit power input. *** Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced starting current of the largest compressor). CONTROLS IR TRETMENT HETING HETING C R R I E R 2 0 1 6 / 2 0 1 7 241

Options Options No. Description dvantages Use 0HXC Low-temperature brine solution 6 Low-temperature glycol solution production down to -10 C Covers specific applications such as ice storage and industrial processes 090, 110, 10, 155, 175, 200, 20, 260, 10, 45 080-75 IP44C electrical protection level 20 Control box tightness reinforced Permits unit installation in more severe environments Tropicalisation 22 Unit control box suitable for tropical climates Reduced relative humidity in the control boxes for 080-75 operation in tropical climates (warm and humid) Soft starter 25 Electronic compressor starter Reduced compressor start-up current 200-75 Cu/Ni condensers Condenser tubes and tubes sheets in 90-10 llows applications with sea water 080-75 Copper/Nickel alloy Cu/Ni condensers + Sakaphen 4 Condenser tubes and tubes sheets in 90-10 llows applications with sea water, improved 080-75 coated water boxes Copper/Nickel alloy and Sakaphen treatment inside durability of water boxes Unit supplied in two assembled parts water boxes 51 Unit supplied in two assembled parts. The unit is Facilitates installation in plant rooms with limited equipped with flanges that allow disassembly of the access unit on site. 080-75 460--60 power supply 60 Power supply of 460 V- ph-60 Hz Permits unit connection to a power network with 080-75 specific characteristics 80--60 power supply 61 Power supply of 80 V- ph-60 Hz Permits unit connection to a power network with 080-75 specific characteristics Evaporator pump electrical power/ 84 Unit equipped with an electrical power/control Quick and easy installation 080-75 control circuit circuit for single evaporator pumps Dual evaporator pump electrical power/control circuit 84D Unit equipped with an electrical power/control circuit for dual evaporator pumps Quick and easy installation 080-75 Condenser pump electrical power/ 84R Unit equipped with an electrical power/control Quick and easy installation 080-75 control circuit circuit for single condenser pumps Compressor suction valve 92 Valve set for the compressor suction side to isolate it Simplified service and maintenance 080-75 in the refrigerant circuit. Evaporator with one pass 100C Evaporator with one pass on the water-side. Evaporator inlet and outlet on opposite sides. Quick and easy installation. Reduced evaporator 080-75 pressure losses. Condenser with one pass 102C Condenser with one pass on the water-side. Quick and easy installation. Reduced condenser 080-75 Condenser inlet and outlet on opposite sides. pressure losses. 21 bar evaporator 104 Reinforced evaporator for extension of the Covers applications with a high water column 080-75 maximum water-side service pressure to 21 bar (high buildings) 21 bar condenser 104 Reinforced condenser for extension of the Covers applications with a high water column 080-75 maximum water-side service pressure to 21 bar (high buildings) Reversed evaporator water 107 Evaporator with reversed water inlet/outlet Simplification of the water piping 080-75 connections Reversed condenser water 107 Condenser with reversed water inlet/outlet Simplification of the water piping 080-75 connections JBus/ModBus gateway 148B Two-directional communications board, complies Easy connection by communication bus to a 080-75 with JBus/ModBus protocol building management system BacNet gateway 148C Two-directional communications board, complies Easy connection by communication bus to a 080-75 with BacNet protocol building management system LON gateway 148D Two-directional communications board, complies Easy connection by communication bus to a 080-75 with LON protocol building management system High condensing temperature 150 Increased condenser leaving water tempe-rature up to 6 C. Control of the condenser leaving water llows applications with high condensing temperature (for heat reclaim or dry cooler 080-75 High condensing temperature in non-reversible applications Control for low condensing temperature systems RS 485 communication interface with open protocol Dual discharge valve installed with three-way valve Code compliance for Switzerland in addition to PED code temperature. applications) 150 Operation in heat pump mode only with condenser llows applications with high condensing 080-75 leaving water temperature up to 6 C. temperature (for heat reclaim or dry cooler applications) 152 Output signal (0-10 V) to control the condenser Used for applications with cold water at 080-75 water inlet valve condenser inlet (well water). In this case the valve controls the water entering temp. to maintain an acceptable condensing pressure. 155 dditional RS 485 communication board Communication via CCN protocol 080-75 194 Three-way valve upstream of the discharge valves on the evaporator and the oil separator Vallve change and inspection facilitated without refrigerant loss. Complies with European standard EN 78/BGVD4. 197 dditional tests on the water heat exchangers. Conformance with Swiss regulations in addition dditional supply of PED documents, supple-mentary to the PED code certificates and test certificates. 080-190 080-75 Russian code compliance 199 GOST certification Conformance with Russian regulations (GOST) 080-75 Water connection kit for welded 266 Victaulic piping connections with welded joints. Easy installation 080-75 evaporator connections Water connection kit for welded 267 Victaulic piping connections with welded joints. Easy installation 080-75 condenser connections Water connection kit for flanged 268 Victaulic piping connections with flanged joints. Easy installation 080-75 evaporator connections Water connection kit for flanged condenser connections 269 Victaulic piping connections with flanged joints. Easy installation 080-75 242 C R R I E R 2 0 1 6 / 2 0 1 7

WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC 080-75 Features and advantages Quality design and construction make the 0HXC unit the preferred choice. Non-controlled, Non-ozone depleting HFC-14a refrigerant. HCF-14a is a proven, non-toxic, non-flammable refrigerant. Medium-pressure refrigerant HFC-14a minimises stress on the compressors and ensures their long operating life. The 0HXC units are equipped with screw compressors for extremely quiet operation and low-vibration levels. The 0HXC units exceed the efficiency level of average industry standards for both full- and part-load operation, saving on operating costs, through lower electrical costs. Part of the 0HXC product range is available equipped with the very low temperature option that permits evaporator leaving water temperatures down to -10 C with ethylene glycol or down to -7 C with propylene glycol. The 0HXC control is fully automatic. The leaving water temperature is continuously monitored to detect load and flow changes. This combination provides the most precise temperature control available. Two independent refrigerant circuits - the second one takes over automatically, when the first one malfunctions, maintain-ing partial cooling under all circumstances. Easy installation - the 0HXC chillers are supplied with a full refrigerant charge, and conveniently located power supply and water inlet and outlet connections. uto-diagnostics - quick display of the machine status. Multiple compressor concept for optimised part-load efficiency and minimised starting current. Series star/delta starter, limiting the start-up current on 0HXC 080-190 units. Controls Pro-Dialog Plus control Pro-Dialog Plus is an advanced numeric control system that combines intelligence with great operating simplicity. Pro-Dialog Plus ensures intelligent leaving water temperature control and optimises energy requirements. The PID control algorithm with permanent compensation for the difference between the heat exchanger entering and leaving temperature, anticipates load variations, guarantees leaving water temperature stability and prevents unnecessary compressor cycling. The long-stroke electronic expansion valves (EXV), together with refrigerant level control via heat exchange in the evaporator, allows a significant energy efficiency improvement at part load conditions, and faultless chiller operation in a wider temperature range. djustable ramp loading, according to the inertia of the application, avoids load increases that are too fast and too frequent, increasing unit life and limiting power consump-tion peaks. Several capacity loading possibilities ensure improved start-up at low outdoor air temperature, and permit use of one of the refrigerant circuits as a back-up circuit. ll units are also available as high condensing temperature and non-reversible heat pump versions (options 150 and 150). Their application range is the same as for the standard units, on which they are based, but they also allow condenser leaving water temperatures of up to 6 C. Pro-Dialog control offers all the advantages of the standard units, plus control of the leaving condenser water temperature. Easy installation The 0HXC has a compact design that fits through a standard door opening and requires minimal indoor space. The 0HXC is supplied as a complete package for easy installation. There are no extra controls, timers, starters or other items to install. 0HXC units have a single power point and one main disconnect/isolator switch for sizes 0HXC 080 to 190, and one power point and one main disconnect/ isolator switch per circuit for sizes 0HXC 200 to 75. The hydraulic connections are simple and facilitated by the use of Victaulic connections for the evaporator and condenser. Simple to service Mechanically-cleanable evaporator and condenser Twin-screw compressors which require minimum routine service or maintenance. Easily accessed suction and discharge pressure and temperature information via a display module. Pro-Dialog Plus ensures preventive protection and enhances chiller reliability. Equalisation of compressor operating hours No capillary tubes or pressostats (except as safety device) Pro-Dialog Plus monitors all chiller safety parameters. The fault history function and the fault codes facilitate immediate location of faults and in certain cases the condi-tions causing the alarm. Prognostic and preventive mainte-nance functions (incorrect water loop, oil filter dirty etc.) permit anticipation of possible problems. Pro-Dialog Plus operator interface CONTROLS IR TRETMENT HETING HETING C R R I E R 2 0 1 6 / 2 0 1 7 24

Operating limits, standard units Condenser water flow rates Evaporator water flow rates Minimum flow rate, l/s* Maximum flow 0HXC Open loop Closed rate, l/s** loop 080-110 2. 7 28.2 120-10.1 9. 7.1 140-155.7 11.1 44.5 175-190 4. 1 51.9 200 4.9 14.8 59.2 20-285 6.7 20.1 80.4 10-75 8 24 95.9 * Based on a velocity of 0. m/s in a closed loop and 0.9 m/s in an open loop. ** Based on a water velocity of.6 m/s. 0HXC Minimum flow rate, l/s 080-090 5.2 20.8 100 6.5 25.9 110 7.4 29.6 120-10 8..4 140-155 9.4 7.8 175-190 11.5 45.9 200 14.1 56. 20 16. 65.2 260-285 18. 7.4 10 20.9 8.7 45-75 2 91.9 Maximum flow rate, l/s* * The maximum flow rate corresponds to a pressure drop of 100 kpa. Operating range, standard units 58 50 45 5 0 25 20 15 1 B C Notes: 1. Evaporator and condenser Δ T = 5 K 2. For start-up at full load with a condenser water entering temperature below 20 C, a three-way valve must be used to maintain the correct condensing temperature.. Maximum condenser water leaving temperature 50 C (at full load). 4. For low evaporator leaving water temperatures <+4 C and >-10 C please order option 6. Standard unit operating at full load. B Standard unit operating at reduced load. C Units operating with head pressure control with analogue water control valve. For transient operating modes (start-up and part load) the unit can operate down to a condenser entering water temperature of 1 C. 4 5 10 1 15 C dditional operating range for high condensing temperature units and non-reversible heat pumps. 244 C R R I E R 2 0 1 6 / 2 0 1 7

WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC 080-75 Operating limits, units for very low temperature (option 6) Evaporator water flow rate with 5% ethylene glycol 0HXC Minimum flow rate, l/s* Maximum flow rate, l/s** 090 8 15.7 110 10.6 21. 10 12.4 25.1 155 14.5 28.1 175 15.6 200 20.5 8 20 21 9.7 260 24.1 48. 10 29.6 62 45 0.2 6 * Based on a Reynolds number of 4000. ** Based on a water velocity of.6 m/s. For very low temperature applications the amount of antifreeze solution added is critical for the unit operation. The following amounts are required: Evaporator leaving water temperature, C Ethylene glycol, % Propylene glycol, % -6 25 27-7 28 0-8 0 N -9 N -10 5 N Evaporator water flow rate with 0% propylene glycol 0HXC Minimum flow rate, l/s* Maximum flow rate, l/s** 090 11.1 15.7 110 14.2 21. 10 16.7 25.1 155 19.1 28.1 175 21.1 200 25.1 8 20 27.4 9.7 260 2. 48. 10 40 62 45 40.6 6 * Based on a Reynolds number of 4000. ** Based on a water velocity of.6 m/s. Operating range, units for very low temperature (option 6) Operating range 5% ethylene glycol Notes: 1. Evaporator ΔT = 4 K max. - condenser ΔT = 5 K 2. Operating range applicable for full and reduced load.. t full load with a condenser water entering temperature below 20 C, a three-way valve must be used to maintain the correct condensing temperature. C R R I E R 2 0 1 6 / 2 0 1 7 Operating range 0% propylene glycol 50 48 44 20 15 1 C D -7 0 4 1 15 Legend C Unit operating with condensing pressure control with an analogue water control valve. For transient operating modes (start-up and part load), the unit can operate down to a condenser entering water temperature of 1 C. D Operation permitted, but performance is not optimised. 245 CONTROLS IR TRETMENT HETING HETING

Dimensions/clearances The 0HXC fits through a standard door opening, minimising installation cost. 0HXC 080-190 600 Legend ll dimensions are given in mm. Evaporator Condenser 0HXC-080 0HXC-090 0HXC-100 0HXC-110 1 C Required clearances for maintenance Recommended space for tube removal (clearances D and E can be either on the right or the left-hand side). Water outlet 2 Water inlet 5 Power supply connection D E B 500 Notes: Non-certified drawings. Refer to the certified dimensional drawings supplied with the unit or available on request, when designing an installation. 4 4 For the location of fixing points, weight distribution and coordinates of the centre of gravity refer to the certified dimensional drawings. 700 F 0HXC B C D E F 080-100 2558 980 1800 2200 1000 85 110 2565 980 1850 2200 1000 85 120-155 275 980 1816 2990 1000 689 175-190 275 980 1940 2990 1000 689 246 C R R I E R 2 0 1 6 / 2 0 1 7

WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC 080-75 0HXC 200-75 500 1 2 E 500 4 B C D 4 Legend ll dimensions are given in mm. Evaporator Condenser Required clearances for maintenance F Recommended space for tube removal (clearances D and E can be either on the right or the left-hand side). Water outlet Water inlet 5 Power supply connection 700 Notes: Non-certified drawings. Refer to the certified dimensional drawings supplied with the unit or available on request, when designing an installation. For the location of fixing points, weight distribution and coordinates of the centre of gravity refer to the certified dimensional drawings. 0HXC B C D E F 200 90 1015 1980 600 1000 489 20-285 924 1015 2060 600 1000 489 10-75 45 1015 2112 4200 1000 50 CONTROLS IR TRETMENT HETING HETING C R R I E R 2 0 1 6 / 2 0 1 7 247