Since 1983 Nuova COTERM has developed a wide range of water heaters.

Similar documents
1 VICTRIX ZEUS Superior kw I features

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

C Tahiti. condensing

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Wall-mounted air heaters for outdoor installation MEC EX C

VICTRIX Superior kw Export VICTRIX Superior kw X Export

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

Condensing, pre-mixed, wall-hung gas boilers with water tank

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

RinNOVA. User manual and installation instructions

Light oil - kerosene burner

SPECIFICATIONS - NIKE

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

INSTALLATION AND OPERATION MANUAL

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

GAS AIR HEATER RANGE

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

GAS FRYER, FG C

Compact wall hung boiler. Micro processor Brass Hydraulic set

ENERGY TOP. Condensing boiler solutions

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Gas heaters and convectors ROBUR

VELA COMPACT INSTALLATION USE AND MAINTENANCE

INDUSTRIAL / DOMESTIC WATER HEATERS

"HC" AIRFLO. In-duct firing line burner

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Installation & Maintenance Manual

Series 1000 & Storage Water Heaters

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

RIELLO 40 GS/M SERIES

LBF RANGE BALANCED FLUED WATER HEATERS

INSTALLER INSTRUCTIONS

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: CODICE: AST 14C157/00. Wall-hung boilers

NEW. Quality and efficiency made of experience! Oil- and gas heated boilers for the professionals manifold proven.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

Light oil burners. One stage operation

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

GHP AWO 38 Technical overview

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

PACKAGED METALLIC BURNERS

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Light oil / kerosene burner

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Sirius FS. Working towards a cleaner future

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Recourse to the italian Law - SIENA COURT in case of controversy shall apply.

DH-Direct Fired Poultry Farm Diesel Heater

Boiler & Water Heater

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

RINNOVA COND. User manual and installation instructions

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

The ultimate in air handling units: directly and indirectly fired

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

6/8 burners gas range on gas oven

Oil burners Brûleurs fioul Stookoliebranders

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

Super four. Installation and servicing instructions

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

CAST IRON ATMOSPHERIC BOILERS

STATIONARY HEATERS 2011/

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Waste/Multi Oil Boilers from Flexiheat

BG2000S PRE-MIX GAS BURNER

The unit is encased in a stainless steel cabinet; doors are painted, pre-galvanized carbon steel.

INSTALLATION AND MANINTENANCE INSTRUCTIONS

The ultimate in air handling units: directly and indirectly fired

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

Air Handling Units. T F E.

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Transcription:

Since 1983 Nuova COTERM has developed a wide range of water heaters. Thank to careful attention to market demands and continuous research towards new solutions, Nuova COTERM is able to offer clients the most competitive water heaters range. Products reliability is guaranteed by strict quality controls carried out in the Nuova COTERM laboratory which is equipped with suitable instruments to control the combustion process

Serie S Gas - Oil Fired, Cryolite Glass Finished Industrial Duty Water Heaters Gas - Oil Fired Burner SERIE S - gas UM S 60 S 75 S 90 S 115 BURNER RIELLO mod. BS 2 BS 2 BS 3 BS 3 BURNER TYPE RIELLO tipo 912 T1 912 T1 913 T1 913 T1 CAPACITY Litri 320 320 317 280 NOMINAL THERMAL CAPACITY kw 60 75 90 115 WORKING THERMAL POWER kw 51 64 76 96 FUME EVACUATION DUCT Ø mm 220 220 220 220 MAX WATER PRESSURE bar 8 8 8 8 HEATING TIME AT 60 C min. 20 15 14 9 CONSTANT DRAWING AT 60 C ( T 45 C) l/h 975 1224 1455 1847 CONSTANT DRAWING AT 45 C ( T 30 C) l/h 1462 1835 2180 2755 CONSTANT DRAWING AT 40 C ( T 25 C) l/h 1754 2203 2615 3305 METHANE G20-20 mbar PRESSURE valve inlet GAS INLET PRESSURE mbar 20 20 20 20 PRESSURE TO BURNER mbar 4 6 3 4,3 GAS CONSUMPTION (15 C e 1013 mbar) m 3 /h 6,35 7,94 9,53 12,17 GAS PROPANO G31-30/37/50 mbar PRESSURE valve inlet GAS INLET PRESSURE mbar 30/37/50 30/37/50 30/37/50 30/37/50 PRESSURE TO BURNER mbar 4,4 6,5 2,6 3,7 GAS CONSUMPTION (15 C e 1013 mbar) Kg/h 4,9 6 7,4 9,1 GAS BUTANO G30-30/50 mbar PRESSURE valve inlet GAS INLET PRESSURE mbar 30/50 30/50 30/50 30/50 PRESSURE TO BURNER mbar 6,3 8,7 3,35 4,9 GAS CONSUMPTION (15 C e 1013 mbar) Kg/h 4,81 5,97 7,31 9,01 Industrial duty gas fired water heater designed to provide a highly cost effective water boiler for high users (SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SITES, HOTELS, REST HO- MES, GYMS, SAUNAS ETC.). BOILER: made of top quality and very thick steel casing, featuring a carefully applied cryolite glass finish, which ensures a higher resistance to scaling. CASING: pre-painted sheet metal. BURNER: with blown air; not included in the boiler. The burner must be installed by the customer. INSULATION: made from fibreglass rolls, which ensure an even insulation. SERIE S - gas oil UM S 60 S 75 S 90 S 115 BURNER RIELLO mod. RG 2 RG 2 RG 3 RG 3 BURNER TYPE RIELLO tipo 377 T1 377 T1 393 T1 393 T1 GAS OIL NOZZLE tipo 1,25x80B 1,5x80B 1,75x80B 2,25x80B CAPACITY Litri 320 320 317 280 NOMINAL THERMAL CAPACITY kw 63 76 88 114 WORKING THERMAL POWER kw 54 64 74 96 FUME EVACUATION DUCT Ø mm 220 220 220 220 MAX WATER PRESSURE bar 8 8 8 8 HEATING TIME AT 60 C min. 20 15 14 9 OIL CAPACITY Kg/h 5,4 6,4 7,5 9,6 PUMP PRESSURE bar 12 12 12 12 CONSTANT DRAWING AT 60 C ( T 45 C) l/h 975 1224 1455 1847 CONSTANT DRAWING AT 45 C ( T 30 C) l/h 1462 1835 2180 2755 CONSTANT DRAWING AT 40 C ( T 25 C) l/h 1754 2203 2615 3305 DIMENSIONAL FEATURES COLD WATER INLET 1 ½ 1 ½ 1 ½ 1 ½ HOT WATER OUTLET 1 ½ 1 ½ 1 ½ 1 ½ DRAIN ¾ ¾ ¾ ¾ ANODE CONNECTION ¾ ¾ ¾ ¾ NUMBER OF ANODES 2 2 2 2 PRESSURE VALVE CONNECTOR 1 1 1 1 MAX. OPERATING PRESSURE bar 8 8 8 8 EMPTY APPLIANCE WEIGHT Kg 261 261 289 289

220 300 400 500 800 A Total height mm 1600 1950 1766 2036 2146 B Water header body height mm 1265 1615 1430 1700 1810 C Base width mm 710 710 810 810 1010 D Water heaters Ø mm 700 700 800 800 1000 E Drain 3/4 mm 480 480 460 460 545 F Cold water inlet 1 1/4 mm 645 645 625 625 645 G Recirculation 1 1/4 mm 890 950 1026 1026 990 H Hot water outlet 1 1/4 mm 1170 1460 1325 1595 1604 I Fume exhaust axis 60/100 mm 1700 2050 1866 2136 2246 L gas inlet mm 630 630 630 630 630 GTF Gas Fan Assisted Sealed Chamber Unità 220 300 400 500 800 Capacity of the tank lt 212 310 410 510 810 Nominal heat input KW 30 34 34 34 34 Nominal heat output KW 26,8 30,6 30,6 30,6 30,6 Combustion efficiency % 92% 93% 93% 93% 94% Natural gas rate (G20) m 3 /h 3,17 3,60 3,60 3,60 3,60 LPG gas rate (G30/31) Kg/h 2,13 2,50 2,50 2,50 2,50 Recovery time ( T 25 C) min. 15 17 23 29 46 Recovery time ( T 45 C) min. 28 31 41 52 82 Single withdraw ( T 25 C) lt 484 660 880 1100 1760 Single withdraw ( T 45 C) lt 268 366 488 611 977 Continuous water output ( T 25 C) lt/h 921 1052 1052 1052 1052 Continuous water output ( T 45 C) lt/h 512 585 585 585 585 Continuous water output ( T 30 C) lt/h 768 877 877 877 877 Electrical data V-Hz 220-240 V ~ 50 Hz (IP 20) Max water pressure bar 6 6 6 6 6 Empty appliance weight kg 142 166 177 207 300 Full appliance weight kg 354 476 587 717 1110 PARALLEL KIT Mod. 220 / 300 / 400 / 500 /800 CONCENTRIC KIT TO WALL Mod. 220 / 300 / 400 / 500 /800 CONCENTRIC KIT TO ROOF Mod. 220 / 300 / 400 / 500 /800

GTF 80-120 Gas Fan Assisted Sealed Chamber 80 120 Total height (mm.) 1040 1400 Exhaust height 895 1255 Inner diameter exhaust pipe (mm.) 38 38 Inner diameter air intake pipe (mm.) 60 60 GAS INLET 3/8 Diameter flange for inspection and anod replacement (mm.) 85 85 REAR VIEW HOT WATER 1/2 COLD WATER 1/2 FLANGE FOR CLEANING AND ANOD REPLACEMENT FRONT VIEW Unit 80 120 Capacity lt 75 115 Nominal Heat input Kcal/h 4300 4300 K/W 5,0 5,0 Nominal heat output Kcal/h 4040 4040 K/W 4,7 4,7 Combustion efficiency % 94% 94% Single spillage at 40 C (termost. 70 C - inlet temp. 15 C) lt 147 231 First 10 min. spillage at 40 C (termost. 70 C - inlet temp. 15 C) lt 168 252 Recovery time at 40 C (inlet temp. 15 C) min. 25 38 Continuous water output at 40 C (inlet temp. 15 C) lt/h. 164 164 Supply volt 220-240 220-240 Frequency hz 50 50 Electrical power w 26 26 TOP VIEW Max water pressure bar 6 6 Empty weight Kg 49 49 HORIZONTAL KIT Mod. 80 / 120 VERTICAL KIT Mod. 80 / 120 PARALLEL KIT Mod. 80 / 120

GTS Sol Gas Fan Assisted 220 300 400 500 800 Liters 220 300 400 500 800 Solar panel surface ~ 2 ~ 4 ~ 6 ~ 8 ~ 10 Finned heater surface ~ 0.6 ~ 1.0 ~ 1.5 ~ 2.0 > 2.0 Number of users 2-3 3-4 4-5 6-7 10-11

Serie BE Cryolite Glass Finished Industrial Duty Water Heaters BE BE BE BE BE BE BE BE BE BE BTE BTE BTE BTE BTE BTE BTE BTE BTE BTE LITERS 150 200 300 400 500 600 800 1000 1500 2000 A 540 540 700 750 750 800 1000 1000 1500 2000 B 1150 1350 1450 1500 1780 1900 1820 2100 2000 2250 C 480 480 600 650 650 700 900 900 1200 1200 D 280 280 360 360 360 360 370 370 390 400 E 260 380 470 470 600 600 600 600 600 600 F 450 450 500 500 600 600 600 600 600 600 G 70 70 70 70 70 70 70 70 70 70 H ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ I ¾ ¾ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ¼ WEIGHT (Kg) 50 60 85 87 100 120 200 230 280 350 SERIE BE/BTE UM 120 150 200 300 400 500 600 800 1000 2000 PRESSURE bar 6 6 6 6 6 6 6 6 6 6 POWER kw 1,5 2 3 4,5 5 6 8 10 15 20 VOLTAGE V 230 230 230 230 230 380 380 380 380 380 WATER PRODUCTION 15 to 45 C l/h 41 55 82 125 139 167 223 80 280 280 HEATING TIME 15 to 45 C min 218 218 217 191 215 215 215 215 215 215 COIL SURFACE m 2 0,59 0,59 1,05 1,05 1,05 1,05 1,5 1,5 1,5 1,5 WATER PRODUCTION FROM 15 to 45 C C 243 243 432 432 431 605 757 757 757 757 RECOVERY TIME min 37 50 42 56 70 60 63 80 80 80 Ø CONNECTION ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ WATER FLOW RESISTANCE 80/70 C mca 0,1 0,1 0,4 0,5 0,5 1,0 1,8 1, 2,0 2,0 CAPACITY l/h 730 730 1310 1310 1310 1830 2300 2300 3000 3800 This electrical industrial duty water heater is ideal for high water production for applications where gas cannot be used. This electric version is the best solution for SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SI- TES, HOTELS, REST HOMES, GYMS, SAUNAS, and for any applications requiring high water production. BOILER: made of top quality steel sheet metal. CASING: made of pre-painted galvanised sheet metal. THERMOSTAT RESISTANCE UNIT: consisting of a copper resistance available in a range of power outputs according to the water capacities and requirement (see technical datasheet) and of a single pole thermostat to control the temperature of the water. 80 mm THERMAL INSULATION: made of top quality fibreglass to ensure optimal output.

Serie BGP Cryolite Glass Finished Industrial Duty Gas Water Heaters With Natural Draft - Pilot Light BGP BGP BGP BGP LITERS 300 400 500 900 A 1590 1890 1980 1950 B 1390 1690 1780 1750 C 750 750 800 990 D 650 650 700 900 E 440 440 440 480 F 710 930 930 1120 G 1330 1610 1710 1850 I 200 200 200 200 M 520 520 520 520 N 120 120 120 105 P 1"¼ 1"¼ 1"¼ 1"¼ Q R S T COLD WATER INLET 1 - SHUTOFF VALVE 3 - SAFETY VALVE 2 - PRESSURE REDUCER 4 - EXPANSION TANK HOT WATER OUTLET DRAINAGE CONNECTION - ½" 5 - DRAIN VALVE RECIRCULATION CONNECTION WEIGHT (Kg) 165 180 215 320 SERIE BGP UM 300 400 500 900 CAPACITY OF THE TANK Litri 292 380 485 850 NOMINAL HEAT INPUT kw 43 46,5 49 82,5 WORKING THERMAL POWER kw 36,55 39,52 41,65 70,12 FUME EVACUATION DUCT Ø mm 200 200 200 200 MAX WATER PRESSURE bar 6 6 6 6 FUME TEMPERATURE C 135 150 150 193 RECOVERY TIME 45 C min. 17 20 25 26 CONSTANT DRAWING AT 45 C l/h 1047 1133 1194 2010 CONSTANT DRAWING AT 65 C l/h 628 680 716 1206 METHANE G20-20 mbar PRESSURE valve inlet CONSUMPTION m3/h 4,55 4,92 5,18 8,73 BURNER NOZZLE Ø mm 4 x 2,8 4 x 2,8 4 x 2,8 6 x 3,0 PILOT FLAME NOZZLE Ø mm 2 x 0,27 2 x 0,27 2 x 0,27 2 x 0,27 PRESSURE TO BURNER mbar 12,0 13,0 15,5 13,0 MASS FUME CAPACITY g/s 18,0 19,5 20,6 34,7 GPL G30/G31-30/37 mbar PRESSURE valve inlet CONSUMPTION Kg/h 3,21 3,47 3,66 6,17 BURNER NOZZLE Ø mm 4 x 1,65 4 x 1,70 4 x 1,75 6 x 1,85 PILOT FLAME NOZZLE Ø mm 1 x 0,22 1 x 0,22 1 x 0,22 1 x 0,22 Industrial duty gas fired water heater designed to provide a highly cost effective water boiler for high users (SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SITES, HOTELS, REST HO- MES, GYMS, SAUNAS ETC.) BOILER: made of top quality and very thick steel casing, featuring a carefully applied cryolite glass finish, which ensures a higher resistance to scaling. CASING: pre-painted sheet metal. BURNER: made of stainless steel. The burner is supplied with a nozzle kit for gas conversion. PILOT BURNER: suitable for any type of gas. THERMOCOUPLE: to ensure a safe gas flow to the burner. ELECTRIC VALVE: supplied with a pressure regulator and safety valve which stops the gas from being released should the pilot light go off. INSULATION: made of fibreglass rolls, which ensure an even insulation.

Serie BGPE Cryolite Glass Finished Industrial Duty Gas Water Heaters With Natural Draft - Electronic Ignition BGP-E BGP-E BGP-E BGP-E LITERS 300 400 500 900 A 1590 1890 1980 1950 B 1390 1690 1780 1750 C 750 750 800 990 D 650 650 700 900 E 440 440 440 480 F 710 930 930 1120 G 1330 1610 1710 1850 I 200 200 200 200 M 520 520 520 520 N 120 120 120 105 P 1"¼ 1"¼ 1"¼ 1"¼ Q COLD WATER INLET 1 - SHUTOFF VALVE 3 - SAFETY VALVE 2 - PRESSURE REDUCER 4 - EXPANSION TANK R HOT WATER OUTLET S DRAINAGE CONNECTION - ½" 5 - DRAIN VALVE T RECIRCULATION CONNECTION WEIGHT (Kg) 165 180 215 320 SERIE BGP-E UM 300 400 500 900 CAPACITY OF THE TANK Litri 292 380 485 850 Industrial duty gas fired water heater designed to provide a highly cost effective water boiler for high users (SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SITES, HOTELS, REST HO- MES, GYMS, SAUNAS ETC.). BOILER: made of top quality and very thick steel casing, featuring a carefully applied cryolite glass finish, which ensures a higher resistance to scaling. CASING: pre-painted sheet metal. BURNER: made of stainless steel. The burner is supplied with a nozzle kit for gas conversion. IGNITION AND DETECTION ELECTRODES: to ensure a safe gas flow to the burner. ELECTRIC VALVE: fitted with a pressure regulator and a safety valve which stops the gas from being released should the pilot light go off. INSULATION: made of fibreglass rolls, which ensure an even insulation. NOMINAL HEAT INPUT kw 43 46,5 49 82,5 WORKING THERMAL POWER kw 36,55 39,52 41,65 70,12 FUME EVACUATION DUCT Ø mm 200 200 200 200 MAX WATER PRESSURE bar 6 6 6 6 FUME TEMPERATURE C 135 150 150 193 RECOVERY TIME 45 C min. 17 20 25 26 CONSTANT DRAWING AT 45 C l/h 1047 1133 1194 2010 CONSTANT DRAWING AT 65 C l/h 628 680 716 1206 METHANE G20-20 mbar PRESSURE valve inlet CONSUMPTION m3/h 4,55 4,92 5,18 8,73 BURNER NOZZLE Ø mm 4 x 2,8 4 x 2,8 4 x 2,8 6 x 3,0 PRESSURE TO BURNER mbar 12,0 13,0 15,5 13,0 MASS FUME CAPACITY g/s 18,0 19,5 20,6 34,7 GPL G30/G31-30/37 mbar PRESSURE valve inlet CONSUMPTION Kg/h 3,21 3,47 3,66 6,17 BURNER NOZZLE Ø mm 4 x 1,65 4 x 1,70 4 x 1,75 6 x 1,85

Serie BG Cryolite Glass Finished Industrial Duty Gas Water Heaters With Natural Draft - Pilot Light BG BG BG BG BG BG BG BG BG LITERS 120 150 200 300 400 500 600 800 1000 A 1200 1300 1500 1700 1760 1990 2090 2000 2220 B 1100 1200 1400 1500 1560 1790 1890 1800 2020 C 450 540 540 700 750 750 800 990 990 D 410 480 480 600 650 650 700 900 900 E 260 360 360 375 380 380 390 460 460 F 360 600 725 845 850 920 990 950 1070 G 1130 1230 1430 1235 1270 1520 1610 1440 1680 I 80 100 100 140 140 140 140 160 160 M / 400 400 620 630 630 660 710 720 N / / / 100 100 100 100 120 120 P ¾" ¾" ¾" 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ Q R S COLD WATER INLET 1 - SHUTOFF VALVE 2 - PRESSURE REDUCER HOT WATER OUTLET DRAINAGE CONNECTION - ½" 5 - DRAIN VALVE RECIRCULATION CONNECTION 3 - SAFETY VALVE 4 - EXPANSION TANK T WEIGHT (Kg) 45 55 64 107 117 135 158 252 285 SERIE BG UM 120 150 200 300 400 500 600 800 1000 CAPACITY OF THE TANK Litri 115 150 200 240 390 450 565 780 950 NOMINAL HEAT INPUT kw 5,8 9,9 9,9 17,4 23,7 23,7 23,7 37.0 37,0 WORKING THERMAL POWER kw 4,8 8,2 8,2 14,6 19,9 19,9 19,9 32,5 32,5 FUME EVACUATION DUCT Ø mm 80 100 100 140 140 140 140 160 160 MAX WATER PRESSURE bar 6 6 6 6 6 6 6 6 6 FUME TEMPERATURE C 176 176 176 125 120 115 115 123 123 NATURAL GAS - 20 mbar PRESSURE CONSUMPTION m3/h 0,6 1 1 1,8 2,5 2,50 2,5 3,90 3,90 BURNER NOZZLE Ø mm 2,00 2,40 2,40 3,45 4,10 4,10 4,10 3,15x3 3,15x3 PILOT FLAME NOZZLE Ø mm 2x0,27 2x0,27 2x0,27 2x0,27 2x0,27 2x0,27 2x0,27 2x0,27 2x0,27 PRESSURE TO BURNER mbar 10,9 15,5 15,5 13,3 11,6 11,6 11,6 11,7 11,7 MASS FUME CAPACITY g/s 5,8 6,7 6,7 19,6 18,8 18,8 18,8 32,0 32,0 GPL G30/G31-30/37 mbar PRESSURE CONSUMPTION Kg/h 0,4 0,75 0,75 1,30 1,80 1,80 1,80 2,90 2,90 BURNER NOZZLE Ø mm 1,15 1,60 1,60 1,95 2,40 2,40 2,40 1,80x3 1,80x3 PILOT FLAME NOZZLE Ø mm 0,4 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 MASS FUME CAPACITY g/s 6,8 12,3 12,0 21,5 19,0 19,0 19,0 30,6 30,6 Industrial duty gas fired water heater designed to provide a highly cost effective water boiler for high users (SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SITES, HOTELS, REST HOMES, GYMS, SAUNAS ETC.). BOILER: made of top quality and very thick steel casing, featuring a carefully applied, double cryolite glass or galvanised finish, which ensure a higher resistance to scaling. CASING: pre-painted sheet metal. BURNER: made of stainless steel with three nozzles according to the type of gas used. PILOT BURNER: suitable for any type of gas. THERMOCOUPLE: to ensure safe gas flow to the burner. THERMOSTATIC VALVE: fitted with a pressure regulator and a safety valve which stops the gas from being released should the pilot light go off. INSULATION: made of fibreglass rolls, which ensure an even insulation.

Serie BGE Gas Fired Industrial Duty Water Storage Heaters With Natural Draft - Electronic Ignition BGE BGE BGE BGE BGE BGE BGE BGE BGE BGE LITERS 150 200 300 400 500 600 800 1000 1500 2000 A 1300 1500 1700 1760 1990 2090 2000 2220 2180 2500 B 1200 1400 1500 1560 1790 1890 1800 2020 1900 2300 C 540 540 700 750 750 800 990 990 1290 1290 D 480 480 600 650 650 700 900 900 1200 1200 E 360 360 375 380 380 390 460 460 340 340 F 600 725 845 850 920 990 950 1070 840 940 G 1230 1430 1235 1270 1520 1610 1440 1680 1400 1800 I 100 100 140 140 140 140 160 160 160 160 M 400 400 620 630 630 660 710 720 450 450 N / / 100 100 100 100 120 120 120 120 P ¾" ¾" 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ 1"¼ Q R S COLD WATER INLET 1 - SHUTOFF VALVE 2 - PRESSURE REDUCER HOT WATER OUTLET DRAINAGE CONNECTION - ½" 5 - DRAIN VALVE RECIRCULATION CONNECTION 3 - SAFETY VALVE 4 - EXPANSION TANK T WEIGHT (Kg) 55 64 107 117 135 158 252 285 350 420 SERIE BGE UM 150 200 300 400 500 600 800 1000 1500 2000 Industrial duty gas fired water heater designed to provide a highly cost effective water boiler for high users (SPORT CENTRES, HOSPITALS, LARGE PREMISES, CAMP SITES, HOTELS, REST HOMES, GYMS, SAUNAS ETC.). BOILER: made of top quality and very thick steel casing, featuring a carefully applied, double cryolite glass or galvanised finish, which ensures a higher resistance to scaling. CASING: pre-painted sheet metal. BURNER: Stainless steel burner electronically ignited by means of ionizing flame detection. INSULATION: made of fibreglass rolls, which ensure an even insulation. CAPACITY OF THE TANK Litri 150 200 240 390 450 565 780 950 1450 1900 NOMINAL HEAT INPUT kw 9,9 9,9 17,4 23,7 23,7 23,7 37,0 37,0 42,0 42,0 WORKING THERMAL POWER kw 8,2 8,2 14,6 19,9 19,9 19,9 32,5 32,5 35,3 35,3 FUME EVACUATION DUCT Ø mm 100 100 140 140 140 140 160 160 160 160 MAX WATER PRESSURE bar 6 6 6 6 6 6 6 6 6 6 FUME TEMPERATURE C 176 176 125 120 115 115 123 123 123 123 RECOVERY TIME 45 C min. 40 43 45 33 36 40 38 34 67 70 CONSTANT DRAWING AT 45 C l/h 195 195 418 570 570 570 1035 1047 1047 1100 CONSTANT DRAWING AT 65 C l/h 117 117 251 342 342 342 621 628 628 650 NATURAL GAS - 20 mbar PRESSURE CONSUMPTION m3/h 1 1 1,8 2,5 2,50 2,5 3,90 3,90 4,44 4,44 BURNER NOZZLE Ø mm 2,40 2,40 3,45 4,10 4,10 4,10 3,15x3 3,15x3 3,15x3 3,15x3 PRESSURE TO BURNER mbar 15,5 15,5 13,3 11,6 11,6 11,6 11,7 11,7 13,5 13,5 MASS FUME CAPACITY g/s 6,7 6,7 19,6 18,8 18,8 18,8 32,0 32,0 30,2 30,2 GPL G30/G31-30/37 mbar PRESSURE CONSUMPTION Kg/h 0,75 0,75 1,30 1,80 1,80 1,80 2,90 2,90 3,30 3,30 BURNER NOZZLE Ø mm 1,60 1,60 1,95 2,40 2,40 2,40 1,80x3 1,80x3 1,85x3 1,85x3 MASS FUME CAPACITY g/s 12,3 12,0 21,5 19,0 19,0 19,0 30,6 30,6 28 28

0051 LA NUOVA COTERM s.r.l. 24068 SERIATE (Bg) Via Levata, 10 Tel. 035.290.665 Fax 035.301.843 www.coterm.com e-mail: info@coterm.com COME RAGGIUNGERCI SERIATE BERGAMO Via Levata USCITA SERIATE BRESCIA