www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Similar documents
www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Public Safety DAS Annunciator Panel

SECTION AUTOMATIC TRANSFER SWITCHES

TECHNICAL DATA OBSOLETE

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

MODEL B2 INSTALLATION MANUAL

Model A1600 Series Annunciator

Installation, Operating and Maintenance Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RELEASE DEVICE CONTROLS

Pioneer-R16 Gas Monitor Operator s Manual

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Power Supply Display Module PSDM. Installation and Operation Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

LC2200 Level Controller Installation and Maintenance Instructions

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EXTINGUISHING AGENT RELEASE MODULE

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

4100U City and Relay Cards Installation Instructions

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

PART 4 ELECTRICAL STANDARDS

SAFETY INFORMATION AND WARNINGS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

INTRODUCTION / TABLE OF CONTENTS

MEC 18 Mechanical Exhaust Control

RAM3 Remote Alarm Module

LC3000 Level Controller Installation and Maintenance Instructions

21-light Remote Annunciator. Owner s Manual

Pump-Down Controller MODEL 4052

Powerohm Resistors Digital HRG System

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Instructions Oxygen Controller R8471C 2.1 8/

Pump-Up Controller MODEL 4062

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Technical Manual. Level Alarm Unit CARLA & WIDS

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Universal Clamp Meter

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Electric Release Panel Wiring Tips

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

INTRODUCTION / TABLE OF CONTENTS

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

SAFESMART Backup Controller SAFE-FSP. Installation & Operation Manual

30.45 Electric Release PDRP-2001

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

AC/DC Power Supply and Battery Charger Installation and Maintenance

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

EBC 12 Modulating Fan Control

Interrupted Ignition Series Oil Primary Control

STATUS ALARM HISTORY ALARM RESET

4 & 8-POINT ANNUNCIATORS Instruction Manual

1U ULTRA Compact System

ACCURATE ELECTRONICS INC

MR-2602 Two Zone Fire Alarm Control Panel

Operator: Save these instructions for future use!

ESSEX ENGINEERING CORPORATION

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Model 4001 Series Single Channel Controller

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

vibration switch

RTD TEMPERATURE SENSING SYSTEM

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Transcription:

Ground Fault Protection GADP Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR 737-4787 www.i-gard.com

TABLE OF CONTENTS 1. INTRODUCTION:... 1 2. APPLICATION:... 1 2.1 3 Phase, 3 Wire Delta Connected System Components... 1 2.2 Artificial Neutrals... 1 2.3 Neutral Grounding Resistors... 2 2.4 Alarm Resistor Unit DDR2... 3 3. REFERENCES... 3 4. SPECIFICATIONS... 4 4.1 Power Requirements: 120V, 50/60 Hz, 50VA... 4 4.2 Maximum Ratings:... 4 4.3 Dielectric:... 4 4.4. Remote Alarm Relay Contacts:... 4 4.5 Pick-up Settings:... 4 4.6 Alarm Time Delay:... 4 4.7 Meter Range: 0 to 100% of system let-through current... 4 4.8 Accuracy:... 4 4.9 Temperature Range:0 C to 65 C... 4 4.10. Dimensions:...4 5. DESCRIPTION:... 5 5.1 Frame (GADP-MF2)... 5 5.2 Main Module (GADP-CM2)... 5 5.3 Pulse Module (DS-PM)... 6 6. SHIPMENT:... 6 7. INSTALLATION:... 7 8. CONNECTIONS:... 7 10. MAINTENANCE AND TROUBLESHOOTING:... 9 10.1 Preventative Maintenance... 9 10.2 Troubleshooting... 9 11. TESTING THE GADP:... 11 12. REPAIR AND RECALIBRATION... 12 13. SPARE PARTS:... 12 14. APPENDIX:... 13

TABLE OF FIGURES Figure 1 Dimensional Details GADP...14 Figure 2 Typical Wiring schematic for GADP with delta system shown...15 Figure 3 Connection Diagram for GAPD...16 Figure 4 Typical Test Fault Resistor...16 LIST OF TABLES Table 2 I-Gard Resistors Artificial Neutral Units...2 Table 3 Pulsing Ground Resistors for GADP...3 Table 4 Alarm Resistor Units...3 Table 5 Shipping Information...6

1. INTRODUCTION: 1 The I-Gard GADP is a modular, Ground Alarm Indicator unit designed specifically for Ground Fault Indication and location, on Wye or Delta-connected, three-phase, three-wire, High Resistance-Grounded power systems. It may be used on systems up to any voltage with the use of 120V PTs. An I-Gard Alarm Resistor unit (DDR2) is used to provide the GADP with a means to monitor the power system voltages to ground. This information is utilized by the GADP to determine and confirm whether a ground fault exists somewhere in the distribution system. This same information is also used to detect the occurrence of blown fuses that protect the phase lines connected to the Alarm Resistor unit itself. The GADP is designed to provide an alarm when a single ground fault occurs on a resistance grounded system, and to indicate on which phase, the fault occurred. Means is also provided to locate the fault with a pulsing circuit that can be energized to provide pulsating current in the fault so that the fault can be traced using a simple, flexible-core clamp-on probe. For this purpose it is necessary to have a grounding resistor installed which provides a safe level of current which can be modulated by the pulsing system. When a second fault, on another phase, is incurred by the distribution system, the only limitations on the amount of ground current are the impedances of the faults and the ground circuit between them. Under this condition, extensive damage can occur, making it necessary to clear the first fault as soon as possible. The prime advantage, then, of using the GADP GROUND ALARM INDICATOR unit, is that the user is given early warning of ground faults allowing time to locate and clear the fault to assure maximum service continuity. 2. APPLICATION: The standard GADP GROUND ALARM INDICATOR unit is used in conjunction with the following, appropriately rated, auxiliary components. The following tables list those components. 2.1 3 Phase, 3 Wire Delta Connected System Components. For delta systems an artificial neutral transformer arrangement will be necessary to provide a convenient star-point for the grounding Resistor. The Resistor will be connected between this point and Ground to create the current limiting circuit. Note: If Pulse operation is such as to double normal fault current, then the artificial neutral must be capable of taking this extra current. This generally means that the artificial neutral transformer must be rated at twice the continuous fault current as defined by the grounding resistor under steady state fault conditions. For example if the current rating of the resistor is 5A, then a 10A artificial neutral transformer would be necessary to pulse up to 10A. The OHMNI-PM series resistors do not require double current rated artificial neutrals since they pulse to a lower current when pulsing is invoked. 2.2 Artificial Neutrals

2 I-Gard provides artificial neutrals in the form of zig-zag transformers for various voltages, as standard units. See Table 1. For systems with voltages in excess of 4160V it is usually more convenient to use a broken-delta transformer arrangement and close the secondary delta with a current limiting Resistor. See Application Guide for Ungrounded and High-Resistance Grounded Systems C-400E for more details or call I-Gard. Continuous Current Rating (Amps) 2.3. Neutral Grounding Resistors System Line to Line Voltage (Volts) Catalogue No. 1 480 DDAI-1004* 2 480 DDAI-2004* 5 480 DDAI-5004 1 600 DDAI-1006* 2 600 DDAI-2006* 5 600 DDAI-5006 2 2400 DDAI-2024 5 2400 DDAI-5024 10 2400 DDAI-10024 2 4160 DDAI-2040 5 4160 DDAI-5040 10 4160 DDAI-10040 Table 1 I-Gard Resistors Artificial Neutral Units A special Grounding Resistor Type OHMNI-PM is recommended for the GADP operation to allow the Pulse Module to pulse the Ground Current. This is made possible when a Pulse Module in the GADP is connected to a Solid State switch in the OHMNI-PM. The Pulse Module (DS-PM) provides a current pulse from its output terminals from a 12V dc pulse, with a variable pulse rate. This current controls the Solid State Switch which in turn switches an auxiliary resistor into the Ground Resistor path causing the Ground current to be reduced on the positive half cycle of the pulse. The result is a Ground Current that is pulsating from high to low, which a hand-held current probe wrapped around all conductors of a faulted circuit can readily detect. The standard Neutral Grounding Resistors available are rated as per Table 2 below. Catalog Number System Voltage I G HI/LO (with 100%fault) OHMNI-4PM-01 480V 1/0.5A OHMNI-4PM-02 2/1A OHMNI-4PM-05 5/2.5A OHMNI-4PM-10 10/5A OHMNI-6PM-01 600V 1/0.5A OHMNI-6PM-02 2/1A OHMNI-6PM-05 5/2.5A

OHMNI-6PM-10 10/5A 3. REFERENCES Table 2 Pulsing Ground Resistors for GADP 2.4 Alarm Resistor Unit DDR2 3 The GADP must also be used with a voltage divider resistance device or Alarm Resistor Unit Type DDR2. This device matches the GADP to the system, and reduces the Line to Ground voltage levels from system voltage to electronic levels. Furthermore, this allows the GADP to determine which phase is faulted and the level of the fault on the system. The bar graph meter derives its indication directly from the DDR2 N-Ground voltage level, without any need to have a connection to the Grounding Resistor at all. Table 3 indicates the DDR2 types available. Catalogue No. DDR2-4 DDR2-6 DDR2-2 DDR2-1 System Voltage 480V 600V 240V 120V + Used on system voltages over 600V by connecting to P.T.'s with 120V secondaries Table 3 Alarm Resistor Units For further information regarding all of the above components, refer to the following I-Gard manuals: - Application Guide - Ungrounded Systems Instruction Manual Type DDAI Artificial Neutrals Instruction Type DDR2 Alarm Resistor Units Instruction Type NGR Neutral Grounding Resistors Instruction Manual DS-PM Pulse Card C-400E C-430EM C-440EM C-450EM C-412EM

4. SPECIFICATIONS 4.1 Power Requirements: 120V, 50/60 Hz, 50VA 4.2 Maximum Ratings: Control Voltage 104-132V Input Voltage A, B and C to G 240 rms N to G 240 rms 4.3 Dielectric: a) Relay contacts to chassis: 1500 Vrms for a min or 1800 Vrms for a sec. b) Control terminals to chassis: 1500 Vrms for a min or 1800 Vrms for a sec. Note: Do not hi-pot test the unit. Refer to section 10 for details. 4.4. Remote Alarm Relay Contacts: SPDT dry contacts 4.5 Pick-up Settings: Main Module Alarm: 4.6 Alarm Time Delay: Main Module 8 amperes resistive, 5 amperes inductive at 120/240 VAC 8 amperes resistive, 5 amperes inductive at 24 VDC 4 50% of system Ground current.5 seconds minimum 4.7 Meter Range: 0 to 100% of system let-through current 4.8 Accuracy: Alarm Pick-up: ±10% of system let-through current Meter: ±10% of system let-through current Repeatability: ±2% 4.9 Temperature Range: 0 C to 65 C 4.10. Dimensions: See Figure 1 in Appendix 1 I-GARD RESERVES THE RIGHT TO CHANGE SPECIFICATION OF ITS PRODUCTS WITHOUT NOTICE

5. DESCRIPTION: 5 The GADP Ground Alarm Indicator Unit is designed as a plug-in modular enclosure. This arrangement provides convenient draw-out serviceability. A Main Module and Pulsing Module are plugged into these racks to provide system monitoring, far beyond the minimum required by Code. Each enclosure is suitable for flush mounting in switchgear control compartment doors or other convenient panel space. For long life and resistance to vibration damage, all lamps, meter and digital displays are light-emitting diodes (LEDS). 5.1 Frame (GADP-MF2) This component is 8 (205 mm) wide with three edge-connector slots for the Main Module GADP-CM2 and the Pulse Module DS-PM. At the back of the GADP-MF2 there are marked connection terminals. For user connections refer to Figures 2 and 3 in the Appendix. The GADP-CM2 module can only fit in the left-hand position. The DS-PM can be installed on the right hand slot only. The expansion connector, accessible through a slot on the left-hand side panel is reserved for future use. For the GADP-MF2 outline dimensions, refer to Fig. 1 in the Appendix. 5.2 Main Module (GADP-CM2) This component can only be inserted into the two extreme left-hand slots of the Main Frame. Contained in this module is the power supply section (including transformer), which provides the AC and DC voltages, required to operate the GADP unit. For remote alarm indication a SPDT (Form C) relay is provided and wired out to rear terminals. A time delay of 0.5sec is incorporated to prevent undesired momentary alarm indications. Main alarm detection and indicator circuits are located in this module. Three red phase lamps (A, B and C) are available on the module s faceplate for indicating whether any phase has incurred a ground or blown fuse fault. An amber lamp (BLOWN FUSE) serves as a blown fuse alarm indicator. A green lamp (NORMAL) is also provided to indicate when the complete GADP system is functioning under normal conditions. A 10-segment LED bar graph display is incorporated into this module to serve as both the principal local alarm indicator and a meter scale. Two push-button switches are located on the front face of this module. One push-button switch (ALARM SILENCE) provides the means to silence the remote alarm circuit. The other (RESET) provides a reset for the faulted phase indication, as well as energizing the meter function to display the total system Ground current I G at the time, when depressed.

units. 6 Note: the 4-position DIPswitch SW1 on the circuit board 155-112B is not used in GAPD 5.3 Pulse Module (DS-PM) 6. SHIPMENT: The DS-PM can only be inserted into the right hand location in the unit. This module contains a microprocessor pulsing circuit for fault location. It can be configured in different ways depending on the desired mode of operation. A four-position DIPswitch allows the use of NORMAL or INVERTED operation. This allows two modes: - 1) NORMAL In non-pulse condition no current is output to SS switch. Then, when Pulsing Starts current is output with positive current on positive half-cycle of square wave output. 2) INVERTED In non-pulse condition current is output continuously to SS switch. Then, when pulsing current is output on negative half-cycle of square wave output. This allows Pulse up current (e.g. 5A to 10A) in case a) and Pulse down current (e.g. 5A to 2.5A) in case b). Each GADP is carefully inspected before being packed in specially designed containers. The following table lists the components by catalog number The GADP is shipped as a single carton. Other associated devices that may be ordered are included below. COMPONENT GADP-MF (Main Frame) GADP-CM2 (Main Module) Pulse Module OHMNI-PM (Pulsing Ground Resistor) DDR2 (Alarm Resistor Unit) DDAI (Artificial Neutral) TS-SENSOR (Flexible core probe) Table 4 Shipping Information Every unit should be examined immediately upon receipt. If damage or indication of rough handing is apparent, a claim should be filed without delay with the transport company. I-Gard should also be notified promptly if replacements for damaged goods are necessary. If units received are not to be installed immediately, they should be stored in their original containers in an area free of dirt and moisture.

7. INSTALLATION: 7 The GADP will normally be mounted in the main distribution switchgear where ready access can be gained to signal wires, switching device control lines and a power source from which to operate. The enclosure should be flush mounted in either a compartment door or in a fixed surface that facilitates easy access to the back of either unit for viewing and operation. CAUTION Hazard of Electrostatic Damage Care should be taken when handling the Plug-In Modules to ensure that they are not damaged by static electricity. The use of grounded wrist straps or foot straps is recommended, particularly in conditions of low humidity and where synthetic materials such as plastics, nylon etc are allowed to contact the circuit boards or any ungrounded persons handling them.. Failure to observe these precautions may result in permanent damage to the modules. 8. CONNECTIONS: 8.4 It is recommended that the GADP be connected to the properly selected I-Gard Artificial Neutrals or Neutral Grounding resistors listed in Section 2. It can be used with other types of high resistance grounding but in any case, an Alarm Resistor unit (DDR2) and ZSCS current sensors must be used to provide phase voltage and ground fault current information, respectively. 8.4 All user connections are to be made to the rear terminal blocks of the GADP-MF2 or GADP-EF and shall be made with 14 AWG switchboard type wire. 8.4 Phase voltage information is brought to the Main Module by connecting the A, B, C and N terminals of the GADP-MF2 to the identically labelled terminals in the DDR2 Alarm Resistor unit. The ground connection in the Alarm Resistor is to be taken to the user supplied terminal block (noted above) to provide a single point ground connection. The ground should be reliable and use of the door or chassis is not generally recommended. The installer should check that all connections are secure. 8.4 Care should be taken not to exceed the Alarm relay dry contact rating of 8 Amperes, 120/240V AC or 24V DC (Resistive). When connecting remote alarm annunciation circuits an external power source must be used. 8.5 Detailed user connection diagrams, Figures 2 and 3, can be found in the Appendix.

9. OPERATION: 8 9.1 When a ground fault occurs on a high resistance ground system, the GADP unit is designed to detect it, provide an alarm, and display the phase, on which it is located. 9.2 The unit also detects, provides an alarm, and shows which phase of the Alarm Resistor unit connections has a blown fuse. Ground fault current is also monitored by the DDR2 also which provides a voltage proportional to that across the grounding resistor, but without direct connection to the grounding resistor. 9.3 The Main Module simultaneously monitors the phase-to-ground voltages and the voltage developed across a resistor from the DDR2 starpoint to ground. It will detect and show an alarm condition (after 0.5 seconds) during a single ground fault when: 1) One phase to ground voltage goes to below 50% of its nominal rated voltage; 2) The other two phase to ground voltages rise above 30% of their nominal rated value, and 3) The signal developed across a resistor from the star-point to ground in the DDR2 Alarm Resistor unit rises to a preset level when the power system is experiencing a ground fault equivalent to 50% of the NGR let-through current. 9.4 Phase indication, when it occurs, is a latched function, which can only be cleared by pressing the RESET pushbutton switch on the Main Module. The main Alarm, comprised of the bar indicator and the Alarm relay, and Blown Fuse indication are self-resetting when the fault disappears. 9.5 The Blown Fuse circuit is meant to provide an alarm indication when a fuse protecting the Alarm Resistor unit blows. This circuit also controls the remote alarm relay. If a fuse blows before or after a ground fault on the same phase is detected, the faulted phase indicator will begin to flash. However, the blown fuse should always be replaced and the GADP reset to obtain an unambiguous indication of the ground fault condition. 9.6 The ALARM/METER bar type display, located on the Main Module, has a dual function. If the ground current on the power system exceeds 50% of the NGR let-through current, an alarm situation exists and all 10-segments (100%) of the bar will automatically light, to indicate an alarm condition. The bar display also functions as a meter scale, with a full-scale deflection of 100%, referenced to the particular Artificial Neutral or NGR let-through current being used. The approximate ground current can be displayed on this scale by pressing the RESET pushbutton switch for the total system ground current. The seriousness of the fault can be determined from the meter indication (60% is a high resistance fault, 100% a solid ground on one phase 9.7 Once the GADP unit detects a ground fault or a blown fuse condition and goes into alarm, it may be desired that the remote annunciation be silenced. The ALARM SILENCE switch on the Main Module provides this facility. However, the alarm cannot be silenced unless the GADP is already in Alarm. Pressing the RESET switch can restore the remote alarm.

10. MAINTENANCE AND TROUBLESHOOTING: 9 The major advantage of ungrounded or high resistance grounded systems is their ability to provide service continuity with a ground fault on one phase. A single phase fault to ground does not cause high currents to flow in the ground circuit; however, the voltage to ground of the two unfaulted phases rises by 73%, stressing the insulation of the power system components. It is common practice to run a faulted system until it is convenient to shut it down for repairs. The proper operation of the GADP Ground Alarm Indicator unit is therefore very important in order that a fault may be located and corrective maintenance performed. It is recommended that the unit be periodically tested. (Refer to section 10 for instructions.) 10.1 Preventative Maintenance Every effort has been made during the design and manufacture of the GADP components to ensure the reliability of the whole system. Critical components are tested before insertion and the completed subassemblies are subjected to a variety of inspections and tests before shipping. The only maintenance recommended is the periodic verification that the various modules are functioning (refer to sections 10.1 and 10.2 for test procedure). This may be supplemented by an occasional leakage current check. 10.2 Troubleshooting The Ground Alarm Indicator unit components undergo extensive tests before shipment, but occasionally, problems and damage can occur in the field. However, most problems arise from external conditions and incorrect connections in the installation stage. Provided in the following is a list of trouble that could be encountered. If after troubleshooting, the problem cannot be traced or replacement units are required, contact your nearest I-Gard representative or I-Gard factory service. DANGER Hazard of Electrical Shock, Burn or Explosion All installation, servicing and testing referred to in this manual must be performed by qualified personnel. All power should be disconnected prior to removing covers or enclosures and where live conductors may otherwise be exposed. Failure to observe these precautions will result in death or severe personal injury.

10.2.1 No Indications on GADP 10 1. Check that 120 volts AC control power is present at the appropriate rear terminals of the GADP-MF2. 2. Check that the GADP-CM2 module is securely inserted in its proper location. 10.2.2 Blown Fuse Alarm Check fuses protecting the DDR2 Alarm Resistor unit. If any are blown, replace them. DANGER Hazard of Electrical Shock, Burn or Explosion Before installing new fuses be certain that the cause of the blown fuse has been corrected. Installation of a fuse in the presence of a short circuit can be extremely hazardous to the installer! Failure to observe these precautions may result in severe personal injury. 10.2.3 Alarm with no apparent fault 1. Check that this fault is valid by pressing and holding the RESET switch on the Main Module. If the fault is valid, the meter indication should be 50% or above. 2. Check for equal voltages between A and G, B and G and C and G on the outputs of the DDR2 to the GADP Mainframe (Can be done at the GADP inputs also) of 2 to 3 Volts under normal conditions. Voltage from N to G should be zero. 3. If a fault cannot be found, continue to monitor the situation, since faults can be intermittent. 10.2.3 Phase Indication without Alarm present Fault has been cleared, either when a machine or service has been shut off, or fault was intermittent in the first place. 10.2.4 All three Phase lamps flashing Fault has occurred on the dc side of a rectifier such as may be used in VFD, UPS or welder equipment. 10.2.5 Pulse Cannot be found When fault location cannot detect a pulse it may be due to the following reasons:- a) Pulse card fuse has blown or missing.

11. TESTING THE GADP: 11 b) Fault is at an upstream location such as transformer, duct or switchgear where probe cannot be used conveniently. c) Probe battery is dead. d) Probe is set for dc instead of ac measurement. e) Fault has been cleared e.g. switching off a machine or service Refer to Pulse Card Manual C-412EM for further details on fault location. Field-testing should be carried out to maintain a routine check on the operation of the Feeder and Main Modules prior to any necessary repairs or recalibration. WARNING Dielectric Test Hazard Do not Hi-Pot Test the GADP connection terminals. These units are subjected to this class of testing in the factory prior to shipping. If absolutely necessary, remove all modules from the frames to be tested and Hi-Pot all, except the `G' terminal from terminal to chassis. The test voltage must not exceed 1,500 volts (AC rms) for 1 minute or 1,800 volts (AC rms) for 1 second. Failure to observe these precautions may result in permanent damage DANGER Hazard of Electrical Shock, Burn or Explosion All installation, servicing and testing referred to in this manual must be performed by qualified personnel. All power should be disconnected prior to removing covers or enclosures and where live conductors may otherwise be exposed. Failure to observe these precautions will result in death or severe personal injury. The alarm measurement and indicating functions of the GADP modules can be checked in the field To perform such testing, follow the procedure detailed below.

12 11.1. The simplest way to test the GADP is to apply a test fault to the system in a controlled manner. For this test a Test fault should be constructed from a power resistor as shown in Figure 4. Note all components should be rated for the voltage and power required. The power rating of the resistor particularly should be observed. P = I 2 R watts where I is the continuous current in amperes and R is the resistance of the resistor in Ohms. 11.2. The test fault should be connected at a safe location such as a disconnect that can be switched on and off away from people or any hazardous materials. 11.3 Connect the fault to phase A on the system and close the disconnect. Switch on the test fault switch and verify that A Phase lamp flashes on the GAPD. Alarm bar should light up all 10 bars, and NORMAL lamp should go OFF. The alarm horn should energize if connected. Check ALARM contacts for continuity if applicable. 11.4 While in Alarm, check that the SILENCE operates correctly.\ 11.5 Switch Pulse Module START button. Connect TS-SENSOR probe around one of the fault conductors and verify that a visible pulse is obtained on the probe meter indicator. 11.6 Switch off the disconnect and remove all test connections after testing. 12. REPAIR AND RECALIBRATION If any of the previous test results suggest that a particular module should be recalibrated or replaced, contact your I-Gard representative or I-Gard customer service to arrange return. For your protection, please do not return any material without proper authorization. It should be noted that any attempt by the user to replace or recalibrate any component during the warranty period, automatically invalidates the warranty. 13. SPARE PARTS: Due to its modular nature, no spare parts are being supplied for the GADP. Complete subassemblies, however, can be ordered as replacement units.

14. APPENDIX: The following is a list of drawings found in the appendix. FIG. 1 FIG. 2 FIG. 3 FIG. 4 Dimensional details for GADP Typical Wiring schematic for GADP Connection Diagram for GADP Typical Test Fault Schematic 13

7-1/4 in. 184 mm) 8-1/4in. (210 mm) A A 6-1/4 in. (158 mm) 'A' 4 HOLES 0.25in (6 mm) DIA. 6.5 (165 mm) 7.5 (191 mm) Figure 1 Dimensional Details GADP 14 9 in, (229mm) A A 4.0 (102 mm) 6.75 (171 mm)

C ZIG-ZAG IF REQUIRED A B DDAI OHMNI-PM N X 0 POWER SYSTEM + - + - 15 DS-PM GADP RESISTOR DIVIDER DDR2 A B C N ALARM 120V CONTROL HORN Figure 2 Typical Wiring schematic for GADP with delta system shown

TO OHMNI-PM RESISTOR To System line PULSE + _ TO DDR2 MAIN MODULE A B C N 16 GAPD G N.O. COM NC 1 V 2 A 0 C NOT USED Figure 3 Connection Diagram for GAPD TO RELIABLE GROUND TO ALARM DEVICE (HORN etc.) TO CONTROL POWER 120V 50VA FUSED F1 S1 R F Bonded to chassis Figure 4 Typical Test Fault Resistor

ADDITIONAL INFORMATION 17 If you require more information or experience problems with your equipment that persist after taking the steps identified in this manual, contact I-GARD Customer Service at the number below. I-GARD 7615 KIMBEL ST UNIT 1 MISSISSAUGA ON L5S 1A8 CANADA Telephone: 905 673 1553 Fax: 905 673 8472 e-mail: sales@i-gard.com Website: www.i-gard.com