Safety Standard for Refrigeration Systems

Similar documents
ICC CODE CORNER 2015 International Fire Code

BSR/ASHRAE Addendum b to ANSI/ASHRAE Standard FORWORD

Methods of Testing Capacity of Refrigerant Solenoid Valves

1. PURPOSE This standard specifies safe design, construction, installation, and operation of refrigeration systems.

Craig Wolfe Toxalert International, Inc. Mound, MN

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Ammonia Refrigeration RAGAGEP

Ammonia Refrigeration RAGAGEP

ARENA-SAFETY & OPPORTUNITIES MAULIK SHAH, MSC, PENG

Ammonia Refrigeration RAGAGEP

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

Update on ASHRAE 15 Safety Standard for Refrigeration Systems Karim Amrane Air Conditioning, Heating & Refrigeration Institute (AHRI)

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

ASHRAE ADDENDA. Safety Standard for Refrigeration Systems

REFRIGERATION CHAPTER 11

Performance Rating of Refrigerant Pressure Regulating Valves

REFRIGERATION CHAPTER 11

REFRIGERATION CHAPTER 11

Performance Rating of Automatic Commercial Ice-makers

Standard for 2006 Performance Rating Of Positive Displacement Ammonia Compressors and Compressor Units

REFRIGERATION CHAPTER 11

ASHRAE WILL GIVE YOU THE WORLD

Todd Jekel, Assistant Director, IRC Feb. 8, Standard Definition. What is a machinery room?

BSR/IIAR 2-201x Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems November 14, 2014 Public Review #3 Draft

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

Sound Performance Rating of Outdoor Unitary Equipment

Performance Rating of Heat Pump Pool Heaters

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

Providing Solutions. Simplifying Regulation. IIAR Standards. Peter Thomas, P.E., CSP Resource Compliance, Inc.

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Safety Standard for Refrigeration Systems

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

AHRI Standard 751 (SI) 2016 Standard for Performance Rating of Thermostatic Refrigerant Expansion Valves

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

Safety standard developments within ASHRAE 15 and ISO UNEP workshop on safety standards, Bangkok

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Ammonia Detection System Codes and Design Specifications

Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers

Sound Performance Rating of Non-ducted Indoor Airconditioning

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

Performance Rating of Computer and Data Processing Room Air Conditioners

Performance Rating of Unit Ventilators

HIGH-RISE RETROFIT ORDINANCES - NO and NO

rpsa FIRE PROTECTION ENGINEERS

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

Update on Codes and Standards Research. Karim Amrane, Ph.D. Senior Vice President

Safe Operating Procedure

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

1997 STANDARD for APPLICATION OF SOUND RATING LEVELS OF OUTDOOR UNITARY EQUIPMENT. Standard NORTH FAIRFAX DRIVE! ARLINGTON, VIRGINIA 22203

HOT WORK SAFETY PROGRAM:

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

IMC Significant Changes Summary Tier I

Australian/New Zealand Standard

Performance Rating of Heat Pump Pool Heaters

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

Applying VRF? Don t Overlook Standard 15

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

Applying VRF? Don t Overlook Standard 15

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

GASEOUS HYDROGEN SYSTEMS

Specifications for Fluorocarbon Refrigerants

ISHRAE. Guideline document to ISO Version 1 Feb Indian Society of Heating, Refrigerating and Air Conditioning Engineers

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

NFPA 96, 2017 REVIEW SUMMARY

BUILDING CODE INTERPRETATION

(h) Pesticide Application.

CHAPTER 7 ALTERATIONS LEVEL

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

INVESTIGATION FINDINGS III IMPACT OF INADEQUATE VENTILATION AND DISCHARGE SYSTEMS

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS

***DRAFT - NOT FOR FILING***

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

A2L Refrigerants. Objectives 14/09/2017

INTERNATIONAL STANDARD

2015 & 2012 International Mechanical Code Significant Changes and the PA Uniform Construction Code

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

CHAPTER 11 REFRIGERATION

UMC 2012 (Chapter 9): Item # 86. gas utilization appliances having an operating temperature exceeding 500 F (260 C). [NFPA 54:9.1.8.

SEMICONDUCTOR FABRICATION FACILITIES

FIRE & LIFE SAFTEY STANDARD

Performance Rating of Active Chilled Beams

Specifications for Fluorocarbon Refrigerants

CHAPTER 8 CHIMNEYS AND VENTS

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

American National Standard

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

Transcription:

BSR/ASHRAE Addendum a ANSI/ASHRAE Standard 15-2016 First Public Review Draft Safety Standard for Refrigeration Systems First Public Review (April 2017) (Draft shows Proposed Changes to Current Standard) This draft has been recommended for public review by the responsible project committee. To submit a comment on this proposed standard, go to the ASHRAE website at www.ashrae.org/standards-research--technology/public-reviewdrafts and access the online comment database. The draft is subject to modification until it is approved for publication by the Board of Directors and ANSI. The appearance of any technical data or editorial material in this public review document does not constitute endorsement, warranty, or guaranty by ASHRAE of any product, service, process, procedure, or design, and ASHRAE expressly disclaims such. 2016 ASHRAE. This draft is covered under ASHRAE copyright. Permission to reproduce or redistribute all or any part of this document must be obtained from the ASHRAE Manager of Standards, 1791 Tullie Circle, NE, Atlanta, GA 029. Phone: 404-66-8400, Ext. 1125. Fax: 404-21-5478. E-mail: standards.section@ashrae.org. ASHRAE, 1791 Tullie Circle, NE, Atlanta GA 029-205

1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 (This foreword is not part of this standard. It is merely informative and does not contain requirements necessary for conformance to the standard. It has not been processed according to the ANSI requirements for a standard and may contain material that has not been subject to public review or a consensus process. Unresolved objectors on informative material are not offered the right to appeal at ASHRAE or ANSI.) FOREWORD This addendum modifies ASHRAE 15 by making necessary changes to defer regulation of ammonia refrigeration systems to ANSI/IIAR 2. ASHRAE 15 and ANSI/IIAR 2 have historically served as additive standards for regulation of ammonia systems, with ASHRAE addressing general design and IIAR addressing ammonia-specific topics. The arrangement has burdened ASHRAE 15 with a variety of ammonia-specific exceptions, and it challenges designers, engineers, operators, and regulators with the task of deciphering regulations from overlapping standards. These stakeholder groups, which include OSHA and EPA, have questioned the need for two independent standards for ammonia refrigeration systems and have encouraged the elimination of this unnecessary complexity. In response, a comprehensive rewrite of ANSI/IIAR 2 was completed to consolidate necessary regulations for safe design of ammonia systems into ANSI/IIAR 2. Following publication of the resulting edition of ANSI/IIAR 2-2014, a gap analysis with ASHRAE 15 was conducted to validate ANSI/IIAR 2 s suitability to serve as a standalone design standard for ammonia refrigeration. ANSI/IIAR 2-2014 has since been adopted as a reference standard by all U.S. model fire and mechanical codes. In addition, based on the comprehensive nature of ANSI/IIAR 2-2014, the 2018 International Fire Code no longer references ASHRAE 15 for ammonia systems, and the 2018 Uniform Mechanical Code is proposing to entirely drop requirements for ammonia refrigeration in favor of a mandatory reference to ANSI/IIAR 2. The UMC change recognizes that ANSI/IIAR 2 now includes necessary content to serve as both a code and a standard. The changes proposed by this addendum delete requirements and exceptions that are unique to ammonia and R-717, and add a new mandatory reference to follow ANSI/IIAR 2 for ammonia refrigeration systems. Note that some of the text of the standard that is not changed but is included so that the proposed changes will make sense to the reader. Only proposed changes are open to public review; text that is not changed is not open for public review. [Note to Reviewers: This addendum makes proposed changes to the current standard. Some of the text of the standard is not changed but is included so that the proposed changes will make sense to the reader. These changes are indicated in the text by underlining (for additions) and strikethrough (for deletions) except where the reviewer instructions specifically describe some other means of showing the changes. Only proposed changes are open to public review; text that is not changed is not open for public review. Page 2 of 6

2 4 5 6 7 8 9 40 41 42 4 44 45 46 47 48 2. SCOPE 2. This standard shall not apply to refrigeration systems using ammonia (R-717) as the refrigerant. Such systems shall comply with IIAR 2.. DEFINITIONS sealed ammonia / water absorption system: An absorption system where Ammonia (R-717) is the refrigerant and water (R-718) is the absorbent and all refrigerant-containing parts are made permanently tight by welding or brazing. 7. RESTRICTIONS ON REFRIGERANT USE 7.2.2 Industrial Occupancies and Refrigerated Rooms. e. Open flames and surfaces exceeding 800 F (426.7 C) are not permitted where any Group A2, B2, A, or B refrigerant other than R 717 (ammonia) is used. f. All electrical equipment conforms to Class 1, Division 2, of NFPA 705 where the quantity of any Group A2, B2, A, or B other than R-717 (ammonia) in an independent circuit would exceed 25% of the lower flammability limit (LFL) upon release to the space based on the volume determined by Section 7.. TABLE 7.4 Special Quantity Limits for Sealed Ammonia/Water Absorption and Self-Contained Systems Type of Refrigeration System Institutional Maximum lb (kg) for Various Occupancies Public/Large Residential Mercantile Commercial Sealed Ammonia/Water Absorption System In public hallways or lobbies 0 (0) 0 (0). (1.5). (1.5) In adjacent outdoor locations 0 (0) 0 (0) 22 (10) 22 (10) In other than public hallways or lobbies 0 (0) 6.6 () 6.6 () 22 (10) Unit Systems 49 50 51 52 5 54 55 56 In other than public hallways or lobbies 0 (0) 0 (0) 6.6 () 22 (10) 7.4 Location in a Machinery Room or Outdoors. All components containing refrigerant shall be located either in a machinery room or outdoors, where the quantity of refrigerant needed exceeds the limits defined by Section 7.2 and Section 7. a. the quantity of refrigerant needed exceeds the limits defined by Section 7.2 and Section 7., or b. direct fired absorption equipment, other than sealed absorption systems not exceeding the refrigerant quantity limits indicated in Table 7.4 is used. Exception: Self-contained systems are permitted outside of a machinery room provided that such systems are not Page of 6

57 58 59 60 61 62 6 64 65 66 67 68 69 70 71 72 7 74 75 76 77 78 79 80 81 82 8 84 85 86 87 88 89 90 91 92 9 94 95 96 97 98 99 100 101 located in public hallways or lobbies and are limited to the following occupancies and refrigerant quantities: 1. 6.6 pounds ( kg) of refrigerant where located in residential occupancies. 2. 22 pounds (10 kg) of refrigerant where located in commercial occupancies. 7.5 Additional Restrictions 7.5.1.1 Flammable Refrigerants. The total of all Group A2, B2, A, and B refrigerants other than R 717 (ammonia) shall not exceed 1100 lb (500 kg) without approval by the AHJ. 8. INSTALLATION RESTRICTIONS 8.11.2.1 Each refrigerating machinery room shall contain a detector, located in an area where refrigerant from a leak will concentrate, that actuates an alarm and mechanical ventilation in accordance with Section 8.11.4 at a value not greater than the corresponding TLV-TWA (or toxicity measure consistent therewith). The alarm shall annunciate visual and audible alarms inside the refrigerating machinery room and outside each entrance to the refrigerating machinery room. The alarms required in this section shall be of the manual reset type with the reset located inside the refrigerating machinery room. Alarms set at other levels (such as IDLH) and automatic reset alarms are permitted in addition to those required by this section. The meaning of each alarm shall be clearly marked by signage near the annunciators. Exceptions: 1. For ammonia, refer to Section 8.12(g). 2. Detectors are not required when only systems using R-718 (water) are located in the refrigerating machinery room. 8.11.6 No open flames that use combustion air from the machinery room shall be installed where any refrigerant is used. Combustion equipment shall not be installed in the same machinery room with refrigerant containing equipment except under one of the following conditions: a. Combustion air is ducted from outside the machinery room and sealed in such a manner as to prevent any refrigerant leakage from entering the combustion chamber. b. A refrigerant detector, conforming to Section 8.11.2.1, is employed to automatically shut down the combustion process in the event of refrigerant leakage. Exceptions: 1. Machinery rooms where only carbon dioxide (R-744) or water (R-718) is the refrigerant. 2. Machinery rooms where only ammonia (R-717) is the refrigerant and internal combustion engines are used as the prime mover for the compressors. 8.12 Machinery Room, Special Requirements. In cases specified in the rules of Section 7.4, a refrigerating machinery room shall meet the following special requirements in addition to those in Section 8.11: a. There shall be no flame-producing device or continuously operating hot surface over 800 F (427 C) permanently installed in the room. b. Doors communicating with the building shall be approved, self-closing, tight-fitting fire doors. c. Walls, floor, and ceiling shall be tight and of noncombustible construction. Walls, floor, and ceiling separating the refrigerating machinery room from other occupied spaces shall be of at least one-hour fireresistive construction. d. Exterior openings, if present, shall not be under any fire escape or any open stairway. Page 4 of 6

102 10 104 105 106 107 108 109 110 111 112 11 114 115 116 117 118 119 120 121 122 12 124 125 126 127 128 129 10 11 12 1 14 15 16 17 18 19 140 141 142 14 e. All pipes piercing the interior walls, ceiling, or floor of such rooms shall be tightly sealed to the walls, ceiling, or floor through which they pass. f. When refrigerants of Groups A2, A, B2, and B are used, the machinery room shall conform to Class 1, Division 2, of the National Electrical Code.5 When refrigerant Groups A1 and B1 are used, the machinery room is not required to meet Class 1, Division 2, of the National Electrical Code. Exception: When ammonia is used, the requirements of Class 1, Division 2, of the National Electrical Code shall not apply, providing the requirements of Section 8.12(h) are met. h. When ammonia (R 717) is used, the machinery room is not required to meet Class 1, Division 2, of the National Electrical Code!' provided (a) the mechanical ventilation systern in the machinery room is run continuously and failure of the mechanical ventilation system actuates an alarm or (b) the machinery room is equipped with a detector, conforming to Section 8.11.2.1, except the detector shall alarm at 1000 ppm. h. i. Remote control of the mechanical equipment in the refrigerating machinery room shall be provided immediately outside the machinery room door solely for the purpose of shutting down the equipment in an emergency. Ventilation fans shall be on a separate electrical circuit and have a control switch located immediately outside the machinery room door. 9. DESIGN AND CONSTRUCTION OF EQUIPMENT AND SYSTEMS 9.1 Materials 9.1.1 Copper and its alloys shall not be used in contact with ammonia except as a component of bronze alloys for bearings or other non-refrigerant-containing uses. 9.1.2 Aluminum and its alloys are suitable for use in ammonia systems. Table 9.7.5 Relief Devices Capacity Factor R-717 0.5 (0.041) 9.7.8.4.1 Ammonia (R-717). Pressure relief valves serving systems using ammonia as a refrigerant shall dis- charge in accordance with one of the following: a. To atmosphere in accordance with Section 9.7.8.2 b. Internally in accordance with Section 9.7.8. c. To a treatment system approved by the authority having jurisdiction INFORMATIVE APPENDIX A INFORMATIVE REFERENCES 14. IIAR. 2014. IIAR Bulletin 114, Guidelines for Identifica- tion of Ammonia Refrigeration Piping and System Compo- nents. Arlington, VA: International Institute of Ammonia Refrigeration. INFORMATIVE APPENDIX C METHOD FOR CALCULATING DISCHARGE CAPACITY OF POSITIVE DISPLACEMENT COMPRESSOR PRESSURE RELIEF DEVICE Table C-1 Constants for Calculating Discharge Capacity R-717 1.422 17.0 58.0 1.28 Page 5 of 6

144 145 146 147 148 149 150 151 152 15 154 155 156 157 158 159 160 161 162 16 164 165 166 167 Example Determine the flow capacity of a relief device for a CO2 (R-744) compressor with a swept volume (Q) of 160 ft/min (0.0755 m/s). The compressor is equipped with capacity control that is actuated at 90% of the pressure relief device set pressure and has a minimum regulated flow of 10%. Q = 160 ft/min (I-P) Q = 0.0755 m/s (SI) hv = 0.90, assumed PL = 0.1 vg = 0.1185 ft/lbm (I-P) vg = 0.0074 m/kg (SI) a ft 160 0.1 0.9 min lbm W r = = 121.52 (I-P [see C-1]) ft min 0.1185 lb m m 0.0755 0.1 0.9 s kg W r = = 0.92 (SI [see C-1]) m s 0.0074 kg = Wr rw lbm = 121.52 0.65 = 78.99 of air min W (I-P [see C-2]) kg W a = Wr rw = 0.92 0.65 = 0.60 of air (SI [see C-1]) s Converting to standard cubic feet per minute (scfm), where Va = specific volume of air = 1.1 ft/lbm (0.818 m/kg) for dry air at 60 F (15.6 C): SCFM = 1.1 (78.99) = 1,05 ft/min (I-P) SCFM = 0.818 (0.60) = 0.49 m/s (SI) Page 6 of 6