Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

Similar documents
Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Safety. Operating instructions Burners for gas ZIO 165, ZIO 200 DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Safety. Operating instructions Burners for gas ZIC DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 05.

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Control valve S11T. Pilot burner ZT. Control valve S11T

Safety. Operating instructions Heater GP 40 DANGER. Contents WARNING CAUTION. Edition Please read and keep in a safe place

Self-recuperative burner for gas

Burner control unit BCU 370

Safety. Operating instructions Heater GP 95 DANGER. Contents WARNING CAUTION. Changes to edition Please read and keep in a safe place

Burner control unit BCU 370

Burner control unit PFU 780

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Industrial & Commercial Thermal BCU 580

Burner control units BCU 480

Burner control units BCU 560, 565

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Burner control units BCU 560, 565

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

INDITHERM. Low temperature gas burners

Burner control units BCU 460, BCU 465

Operating Instructions TSF 010. Power Failure Venting Unit PM BNE/L (0007)

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Burner control units BCU 480

Manual Isolating Barrier D461 (Revision 05)

Manual Isolating Barrier D461R1 (Revision 01)

Installation, Operation and Service Instructions VARIOMAX. (one-stage) (two-stage) VARIOMAX 06 / 1 VARIOMAX 06 / 2 VARIOMAX 12 / 1 VARIOMAX 12 / 2

A6 Safety Monitoring Device

Instructions SCHICK ceramic - milling set

INDITHERM. Low temperature gas burners

Heating controller Lago

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Operating Instruction SCHICK ceramic - milling set

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

1 - High-velocity gas burners

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

Torch framed Installation Guide

ADSDUDPTB Mounting Base

terrasschwank+ 4A Technical Manual NL (English) Patio gas-infrared-heater 0085BR0505 terrasschwank+ 7/2A with housing

Ignition Burner Maintenance

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Parts Available from

Old documentation - Only for your information! Product is not available anymore!

WARNING FOR YOUR SAFETY FOR YOUR SAFETY. Outback Patio Heaters. Patio Heaters

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

Proline GAS HOB Model TCG40IX Instruction Book

Indirect gas-fired air heater

Manual OW Caution:

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Propane Heater REMKO PGM 30 REMKO PGM 60

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

Physikalisch-Technische Bundesanstalt

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Gas Instantaneous Water Heater

USER MANUAL Gas Countertop Charbroilers

Light oil burners. One stage operation

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

NiteCool TCC-100/RCC-100

TC MODULE (FFD) (with Gas Hob)

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

OPERATING AND MAINTENANCE MANUAL

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

USHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE

INSTALLATION AND MANINTENANCE INSTRUCTIONS

NMG NOZZLE MIX GAS BURNERS

Specifications of V-Line burners

GAS HEATERS MODEL NOS: DEVIL 700, 900/910SS,1600/ 1610SS & 2100 PART NOS: , , , , , &

Instruction Manual for AFS Air Purification Devices for Separating Oil and Emulsion Mist

Installation and maintenance manual

OPERATING MANUAL RAY-NC 1000 SERIES

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Grohtherm Wireless! Installation Instructions Pumped High Pressure

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Operating and Installation Instructions for CRAMER COE Gas Cooker

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

Gas Fire Patio Heater Q9

MULTIPLEX SELF RECUPERATIVE gas burner

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

FLAME HEATER PYRAMID CLFH-10SS OPERATION INSTRUCTIONS

MAINTENANCE AND SERVICE GUIDE

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

BFM. Balanced Flue Commerial Water Heater BFM - 30/50/80/100/120. Installation, User and Service Manual. Innovation has a name.

Instructions for use. Gas hobs for installation in worktops GKS GWS GKS GKS

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

Transcription:

03 Elster GmbH Edition 09.3 Translation from the German 0350560 D F NL E DK S N P GR TR C PL RUS H www.docuthek.com Operating instructions Pilot burners, Contents Pilot burners,... Contents... Safety.... Checking the usage... Setting the gas type.... nstallation...3 Wiring... Tightness test... Commissioning....5 Maintenance...6 Replacing the electrodes...6 Accessories...7 Technical data...7 Declaration of ncorporation....8 Contact...8 Safety Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator. This unit must be installed and commissioned in accordance with the regulations and standards in force. These instructions can also be found at www.docuthek.com. Explanation of symbols,,,... = Action = nstruction Liability We will not be held liable for damage resulting from non-observance of the instructions and non-compliant use. Safety instructions nformation that is relevant for safety is indicated in the instructions as follows: ndicates potentially fatal situations. WARNNG ndicates possible danger to life and limb. CAUTON ndicates possible material damage. All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians. Conversion, spare parts All technical changes are prohibited. Only use OEM spare parts. Transport On receipt of the product, check that the delivery is complete (see Part designations). Report any transport damage immediately. Storage Store the product in a dry place. Ambient temperature: see Technical data. Changes to edition. The following chapters have been changed: Setting the gas type Commissioning M is not included in these operating instructions, see new operating instructions for M, MC, www.docuthek.com -

Checking the usage ntended use onization-controlled pilot burners for safely igniting gas burners. The capacity of the pilot burner should be to 5% of that of the main burner. Can also be used as independently operated burners. For natural gas, town gas, coke oven gas and LPG. Other types of gas on request. This function is only guaranteed when used within the specified limits see also page 7 (Technical data). Any other use is considered as non-compliant. Type code K TN Thermo ionization pilot burner with two electrodes Double-cone olive for 8 mm tube /" NPT internal thread Part designations 6 7 5 3 8 9 nterference-suppressed plug for ignition electrode Plug for ionization electrode 3 onization electrode gnition electrode 5 Air slide valve 6 Gas connection 7 0.7 mm gas nozzle for LPG 8 Cone olive (only for K) 9 Cap screw (only for K) 0 Enclosed documentation: operating instructions Gas connection see type label. 0 Part designations 5 Burner housing Burner housing cover 3 Burner tube set, comprising protective tube a and flame tube b Retaining screw for nozzle insert (in burner housing) 5 Nozzle insert (in burner housing) 6 Enclosed documentation: operating instructions and flow rate curves Rated capacity P max., gas type see type label. D-908 Osnabrück Germany Gas Pmax. Setting the gas type Pilot burners are set for natural gas on delivery. f the pilot burner is to be used with a different type of gas, retrofit the burner for its use. 3 a 6 3 b D-Osnabrück Germany K 0.7 Gas nozzle Ø 0.7 mm (0.08") for LPG. Type code onization pilot burner with forced air supply 50 000 Burner tube length /00 Flame tube length R Rp internal thread Order gas nozzle for town gas Ø.8 mm (0.07") separately (Order No. 77880). 5 6 -

Electric shocks can be fatal! Live components in the housing connection chamber. The burner housing cover must be fitted during ignition. Pilot burners are set for natural gas on delivery. f the pilot burner is to be used with a different type of gas, retrofit the burner for its use. 3 Attention! Live components. nstallation Risk of explosion! Ensure the connection is gastight. nstall the pilot burner so that reliable ignition of the main burner is guaranteed. Attach the pilot burner securely. We recommend that a filter be installed in the gas and air supply line respectively. nlet pressure: natural gas: max. 35 mbar ( "WC), town gas: max. 30 mbar ( "WC), LPG: max. 60 mbar (3 "WC). n the case of higher inlet pressures, insert a gas restrictor orifice. Ensure air intake is not obstructed. The has bare electrodes and no protective flame tube. Protective tube, see page 7 (Accessories). WARNNG Risk of injury! Observe the projecting ionization electrode. Attach the burner using the two holes on the fastening lug. 5 6 + = Natural gas + = LPG = Town gas 7 8 For operation with town gas, screw the retaining screw back in without the nozzle insert do not store the nozzle insert in the connection box: danger of short-circuits. 9 After conversion to another type of gas, adjust the air volume see page 5 (Commissioning). -3 8 mm 9 Connect the pilot gas line with 8 mm tube. When tightening the cap screw 9, ensure that the cone olive 8 is correctly positioned lubricate the cone olive. flow rate curve see www.docuthek.com nlet pressure: Gas [mbar ("WC)] Natural gas 0 (8) Town gas 7 (6.8) LPG 30 () Flow rate curves see www.docuthek.com n the case of higher gas pressures, insert a gas restrictor orifice see page 7 (Accessories).

Connect the PE wire for burner ground to the fastening lug on the burner insert. 3 Tighten the PG cable gland. 3 Connect the pilot gas line with Rp ¼ and the air line with Rp ½. For connecting pilot gas and air lines with NPT thread, order the adapter set see page 7 (Accessories). Wiring Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. For the ionization and ignition cables, use unscreened high-voltage cable: FLSi /7-50 to 80 C (-58 to 356 F), Order No. 0500, or FLK /7-5 to 80 C (3 to 76 F), Order No. 05009. Wire the burner as shown in the connection diagrams of the automatic burner control unit/ ignition transformer. = onization electrode 5 6 Tighten ionization and ignition cables securely. 7 Replace seal and cover and screw into place. 8 Connect the PE wire for burner ground to the burner. Tightness test Risk of explosion and poisoning! To ensure that there is no danger resulting from a leak, check the gas connections on the burner for leaks immediately after the burner has been put into operation. = onization electrode = gnition electrode = Screw for PE wire = gnition electrode 3 Screw for PE wire -

Risk of explosion in case of CO being formed in the furnace chamber! An incorrect change of the burner settings may change the gas/air ratio and lead to unsafe operating conditions. CO is odourless and poisonous! 5 The air slide is open on delivery. Only close the air slide if the burner flame is not stable. Commissioning Risk of explosion! Please observe the appropriate precautions when igniting the burners. Risk of poisoning! Open the gas and air supply so that the burner is always operated with excess air otherwise CO will form in the furnace chamber. CO is odourless and poisonous! Conduct a flue gas analysis. Arrange the adjustment and commissioning of the burner with the system operator or manufacturer. Check the entire system, upstream devices and electrical connections. Pre-purge the furnace chamber with air (5 x furnace chamber volume) before every ignition attempt. Fill the gas line to the burner carefully and correctly with gas and vent it safely into the open air do not discharge the test volume into the furnace chamber. Risk of explosion! f the burner does not ignite although the automatic burner control unit has been switched on and off several times: check the entire system. After ignition, monitor the gas and air pressures measured on the burner and the flame. Measure the ionization current. Switch-off threshold see automatic burner control unit operating instructions. Switch on the system. Open the manual valve. 3 gnite the burner via the automatic burner control unit. Adjust the burner. Set the ionization current by adjusting the air volume. Electric shocks can be fatal! Live components in the housing connection chamber. Re-ignition must be prevented if the burner housing cover is open. Fit the burner housing cover before igniting the burner. nlet pressure for air adjustment screw set at the factory: Gas [mbar ("WC)] Air [mbar ("WC)] Natural gas 0 (8) 0 (8) Town gas 7 (6.8) 35 (3.8) LPG 30 () 30 () 5 6 7 f the air inlet pressure cannot be set to the recommended value owing to the factory setting of the air adjustment screw, readjust the air adjustment screw. Attention! Live components. Turn the air adjustment screw to the left to increase the air flow. Turn the air adjustment screw to the right to reduce the air flow. 8 Replace seal and cover and screw into place. -5

Maintenance We recommend an annual function check. Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. Risk of burning! Dismantled burner components can be hot due to outflowing flue gases. Risk of explosion and poisoning during burner adjustment with an air deficiency! Adjust the gas and air supply so that the burner is always operated with excess air otherwise CO will form in the furnace chamber. CO is odourless and poisonous! Conduct a flue gas analysis. Check the ionization and ignition cables. Measure the ionization current. The ionization current must be at least 5 µa and must not vary. 0 Once the electrodes have been positioned, hand tighten the retaining plate screw using a spanner (approx. 3 turns). After tightening, the electrodes cannot be moved any more. 6 Undo the housing cover screws, remove seal and housing cover. 7 Unscrew the ionization and ignition cables. 8 Unscrew the PE wire for burner ground from the burner. 9 Remove the burner see page 3 (nstallation). Removal and reassembly of the electrodes is facilitated, when the housing is placed in a vertical position on a smooth working surface. 0 Loosen the screws ½ a turn. + μa 3 Disconnect the system from the electrical power supply. Shut off the gas and air supply do not change the restrictor settings. 5 Check the nozzles for dirt. Replacing the electrodes 6 7 Loosen the screw of the retaining plate by turning it approx. 3 turns. 3 mm mm Replace the electrodes one after the other. Align the ignition electrode and the ionization electrode. Adjust the spacing of the electrode tips. 8 Groove for correct positioning of the electrode. Slide the rear guide lug as far as it will go in the direction of the burner housing. Hand tighten the screw. 9 For correct positioning, slide in the electrodes until the projection of the retaining plate engages into the groove. When sliding in the electrodes, ensure they are aligned. -6

5 6 6 mm Align the insulators. Slide the front guide lugs as far as they will go in the direction of the burner head. Hand tighten the screw. Gas restrictor orifice Rp /". For operation of the at the following inlet pressures: nlet pressure in mbar Hole Order Natural Town Propane mm No. gas gas 0 50.3 7570 3 50 50 00.5 757 50 0 00 500. 757 0 50 50 00 0.9 7575 50 500 00 500 0.6 7577 7 For longer burners, slide the other guide lugs against the retaining plate. Hand tighten the screw., Reconnect the electrode plug(s). Produce a maintenance report. Accessories Protective tube set For, heat-resistant. 353700 Gas nozzle For :.8 mm. For operation with town gas. Order No. 77880 Adapter set For connecting the pilot burner to pilot gas and air lines. Comprising one adapter with /-8 NPT internal thread and one adapter with /- NPT internal thread. Technical data Capacity: approx..8 3 kw. Gas types: natural gas, LPG (gaseous) and coke oven gas. Gas inlet pressure: 0 60 mbar (8 "WC), depending on the gas type. Condition on delivery: for natural gas, max. 30 mbar ( "WC), (gas inlet pressures see www.docuthek.com, Kind of document: Flow rate curve). Flame control: with ionization electrode. gnition: direct spark ignition (5 kv ignition transformer). gnition electrode plug: interference-suppressed. gnition head made of galvanized steel. Retaining plate made of galvanized steel. Capacity: approx. to 5 kw. Gas types: natural gas, LPG (gaseous) and coke oven gas. Gas inlet pressure: 5 to approx. 50 mbar ( to approx. 0 "WC), air inlet pressure: 5 to approx. 30 mbar ( to approx. "WC), each depending on the gas type (burner pressures see www.docuthek.com, Kind of document: Flow rate curve). On delivery: natural gas setting (gas and air pressures: 0 mbar (8 "WC)). For cold air only. Flame control: with ionization electrode. gnition: direct spark ignition (5 kv ignition transformer). Housing: AlSi. Protective tube: stainless steel. Flame tube: heat-resistant steel. Max. temperature at the tip of the flame tube: < 000 C (< 83 F), < 900 C (< 65 F) for lambda <. Max. temperature of the protective tube: 500 C (93 F). 79330-7

Declaration of ncorporation pursuant to 006//EC, Annex, No. B The products Burners for gas and are partly completed machines pursuant to Article g which are designed exclusively for installation in or assembly with another machine or other equipment. The following essential health and safety requirements pursuant to Annex of this Directive have been applied and satisfied: Annex, Articles..3,..5,.3.,.5.,.7. The special technical documentation pursuant to Annex V B has been produced and will be transmitted to the competent national authorities in electronic form on request. The following (harmonized) standards have been applied: EN 76- (00) ndustrial thermoprocessing equipment Safety requirements for combustion and fuel handling systems EN SO 00 (00) Safety of machinery Basic concepts, general principles for design The partly completed machine may only be put into service once it has been established that the machine where the product mentioned above is to be installed complies with the provisions of the Machinery Directive (006//EC). Elster GmbH Einbauerklärung / Declaration of ncorporation nach 006//EG, Anhang, Nr. B / according to 006//EC, Annex No. B Folgendes Produkt / The following product: Bezeichnung: Brenner für Gas Description Burner for gas Typenbezeichnung / Type:, M, MC, ist eine unvollständige Maschine nach Artikel g und ausschließlich zum Einbau in oder zum usammenbau mit einer anderen Maschine oder Ausrüstung vorgesehen. is a partly completed machine pursuant to Article g and is designed exclusively for installation in or assembly with another machine or other equipment. Folgende grundlegende Sicherheits- und Gesundheitsschutzanforderungen gemäß Anhang dieser Richtlinie kommen zur Anwendung und wurden eingehalten: The following essential health and safety requirements in accordance with Annex of this Directive are applicable and have been fulfilled: Anhang, Artikel / Annex, Article..3,..5,.3.,.5.,.7. Die speziellen technischen Unterlagen gemäß Anhang V B wurden erstellt und werden der zuständigen nationalen Behörde auf Verlangen in elektronischer Form übermittelt. The relevant technical documentation has been compiled in accordance with part B of Annex V and will be sent to the relevant national authorities on request as a digital file. Folgende (harmonisierte) Normen wurden angewandt: / The following (harmonized) standards have been applied: EN 76- (00) - ndustrielle Thermoprozessanlagen; Sicherheitsanforderungen an Feuerungen und Brennstoffführungssysteme - ndustrial thermoprocessing equipment; Safety requirements for combustion and fuel handling systems EN SO 00 (00) - Sicherheit von Maschinen Grundbegriffe, allg. Gestaltungsleitsätze - Safety of machinery Basic concepts, general principles for design Die unvollständige Maschine darf erst dann in Betrieb genommen werden, wenn festgestellt wurde, dass die Maschine, in der das oben bezeichnete Produkt eingebaut werden soll, den Bestimmungen der Richtlinie für Maschinen (006//EG) entspricht. The partly completed machine may only be commissioned once it has been established that the machine into which the product mentioned above should be incorporated complies with the provisions of the Machinery Directive Elster GmbH 006//EC. Postfach 8 09 D-908 Osnabrück Lotte (Büren) Strotheweg D-950 Lotte (Büren) Tel. +9 (0)5-0 5.0.03 Sandra Runde, Lars Schröder Fax +9 (0)5-3 70 Datum / Date Konstrukteure / Designers info@kromschroeder.com www.kromschroeder.com Sandra Runde, Lars Schröder sind bevollmächtigt, die speziellen technischen Unterlagen gemäß Anhang V B zusammenzustellen. Sandra Runde, Lars Schröder are authorized to compile the relevant technical documentation according to Annex V B. Contact f you have any technical questions, please contact your local branch office/agent. The addresses are available on the nternet or from Elster GmbH. We reserve the right to make technical modifications in the interests of progress. -8 Elster GmbH Postfach 8 09, D-908 Osnabrück Strotheweg, D-950 Lotte (Büren) T +9 5-0 F +9 5-370 info@kromschroeder.com, www.kromschroeder.com