OVER 55 YEARS OF STEAM SHOWER INNOVATION

Similar documents
Signature Series Control

For Tutorials and Troubleshooting visit

OVER 55 YEARS OF STEAM SHOWER INNOVATION

Installation Instructions PRO SERIES

One Touch Control Installation and Operation Instructions

Elite Control Installation and Operation Instructions

Installation Instructions Day Spa Generator

ThermaSol PowerPak Series Installation & Operating Instructions Commercial Steam Bath Generators (Three Phase)

Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -

POWER PAK 480V Commercial Steam bath Generator

SYSTEM INSTALLATION AND SERVICE AT AND 3T STEAMERS

AT and 3T STEAMBATH GENERATORS For Models 4kW thru 14kW With T100 Control (Includes Optional Warm Start)

FREWIN STEAM SHOWER ENCLOSURE

ARLEY STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

Electrical Installation Instructions

Installation, Operation & Maintenance Manual. isteam. Controls. mr.steam. Feel Good Inc.

Mini Mist Installation Instructions. Health. Relaxation. Exhilaration

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

Installation. Please keep this manual for future reference.

SK SERIES INSTALLATION INSTRUCTIONS 1

SYSTEM BASIC WHIRLPOOLS

CORALAIS BODYSPA BATH AND SHOWER FAUCET

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

K60 & KT60 STEAM BATH CONTROLS FOR USE WITH AMEREC AK STEAM GENERATORS

Find thousands more great ideas online

E2 Series Installation

Infrared sauna SUN S Pure Infra User Manual

AMEREC EASYSTEAM STEAMBATH GENERATORS with the R30K Control

signals a situation where minor injury or product damage may occur if you do not follow instructions.

Installation Instructions Acrylic Shower & Tub-Shower Modules Fax on Demand #4010

Installation Manual PS-225 & PS-275

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Headquarters & Technical Support 1958 Steam Way, Round Rock, TX (800) Mon Fri 7:00 7:00 CST Fog-Free Mirrors

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

ATTENTION INSTALLER: Please deliver this manual to homeowner.

NEPTUNE Steam Room Installation Instructions

Installation Manual PS-200 & PS-201

Installation and Operation Manual

Destination Collection Whirlpool Bath Installation Instructions

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Threaded Faucet Installation

Whirlpool Bathtub Model Number: MT618

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

Cable Drain & Cable Drain Trim Kit

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

Commercial Series Installation Instructions. Health. Relaxation. Exhilaration

Clean Water Made Easy

Owners Manual. Pub. No. 601-D

Dishwasher installation guide

User manual Whirlpool

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

Hydrotherapy Jets (Remote Water Quality System)

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

INSTALLATION AND USER MANUAL

Package Content. Decor Star 1 2. PL-011-GS Rev. A

InfraSauna Custom Cut Installation Guide

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

Fleck 5600 Carbon Filter Installation & Start Up Guide

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

WizCG grinder. WizlingCG grinder INSTRUCTION MANUAL

Kallista Bath Flip Drain

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Spa Control System OWNER S MANUAL

Features Luxier SP21-SS

General Guidelines for Installing Mr.Steam. Steambath Systems

Installation Guide BUBBLEMASSAGE. English page T01-A

INSTALLATION INSTRUCTIONS

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Features Luxier SP21-SS

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

OWNER S MANUAL THREE-PERSON & FOUR-PERSON CORNER SAUNAS

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

Oceanic Sauna Heater Manual

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

INSTALLATION AND OPERATING INSTRUCTIONS Page 1

PVC Venting Addendum. RIVA Plus WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY

Installation Instructions for. OmniFount

Decor Star 1. Decor Star PL-037-SS

AQUAPEUTICS MONACO INSTALLATION MANUAL

PL-004-SS. * Proper water pressure is required for simultaneous operations

INSTALLATION AND OPERATING INSTRUCTIONS

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

infrared essential lounge owner s manual

1.6 GALLON ONE PIECE TOILET

Installation Instructions for. CattleMaster Series Fountains

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4010B 4011B

Transcription:

Signature Series Control +Steamhead Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions SET-NTS-XX Traditional, SEM-NTS-XX Modern, SEMR-NTS-XX Modern Recessed. SEC-NTS-XX Contemporary, SER-NTS-XX Regency. OVER 55 YEARS OF STEAM SHOWER INNOVATION

SELECT SELECT 1 STEAM 2 1 STEAM 2 Signature Series Control Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions From top - L to R: SET-XX Traditional, SEM-XX Modern, SEMR-XX Modern Recessed, SEC-XX Contemporary, SER-XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION 2

Signature Series Control Installation Instructions 1 Important Information before You Install The Signature Series Control must be installed inside the shower. The Signature Series control will only function on the current SSM, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH. PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH. STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON, UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD. NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH. DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH. YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY. IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE STEAM ROOM. DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT. THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES. THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME. All products must be installed in accordance with installation instructions provided. Failure to do so may invalidate warranty at manufacturer s discretion. 2016 ThermaSol. 97005_NC 4/16 Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. 3

Signature Series Control Installation Instructions 2 Tools and Materials Parts enclosed Controller (Contemporary style shown here) Silicone Mud Ring (RIK-SEMR-1) for SEMR-NTS-XX installation only Installation instructions, warranty, static cling warning label Materials needed: Signature Series control CAN-Bus Cable (included with generator) Silicone Other materials as required Tools needed: 1/2 drill for surface mount Follow pre-installation instruction on page 5 for recessed mount controls Drill motor Other tools as required 3 Control Installation and Data Cable Connection Surface Mount Installation SEC-XX, SEM-XX, SET-XX, SER-XX, SEC-NTS-XX, SEM-NTS-XX, SET-NTS-XX, SER-NTS-XX Recessed Mount Installation SEMR-XX and SEMR-NTS-XX Data cable to generator Shower wall Shower wall Data cable to generator Make a 1/2" diameter hole in the desired location. The control should be installed 60" from the fl oor of the shower and away from the steamhead. Install recessed control mud-ring (provided with control) during rough-in stage of wall preparation. Fabricate and install materials as precise as possible, following the shape of the mud-ring. See page 6 for detailed instructions. Read warnings on page 3. For illustrative purposes only. Consult with qualifi ed professional for steam room construction details. PN: 97005_NC 4/16 4

Signature Series Control Installation Instructions 4 Control Installation and Data Cable Connection Back of Control Route the data cable (included with generator) through the finished wall to the back side of the control. The other end of the cable runs to the steam generator location or if present to SWM-2 or PDM. NOTE: It is recommended to run the cable through electrical conduit. Connector Detail Back of control or side of generator "ON" Turn Clockwise "OFF" Turn Contact pins Contact pins Cable ends Counter Clockwise DO NOT pinch, nail, staple, wedge, or bind the data cable. DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable. Any damage to the control cable will result in the control not working properly. Carefully connect the data cable to the generator and control BEFORE turning power on to the generator. Back of control or side of generator Side of generator Do not staple, strain or damage data cable Align pins to receptacle visually before tightening Do not force plug Hand tighten only Connect the data cable to steam generator connector. (The other end of the cable runs to the back of the control in the the shower location or to the SWM-2 or PDM if present. Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 97005_NC 4/16 5

Signature Series Control Installation Instructions 5 Mud Ring Installation + Sealing Control For Recessed Controls Only (SEMR-XX and SEMR-NTS-XX) Silicone (included) Recessed Control (shown) Step 1: BEFORE TILE - Use the supplied mud ring by attaching to wall face using a few standard screws. Then tile to the edge of the mud ring. Data Cable Step 2: Once finished tile is completed remove mud ring from wall. Ensure that the total minimum depth is 5/8 so control face sits flush to wall. Connect cable so it is not lost in wall. Test fit for flushness. Step 3: IMPORTANT: Fully test the control system prior to silicone. Once desired fit is achieved coat back of control face with supplied silicone. Firmly press to wall surface and wipe excess silicone from around control. Tape into LEVEL position and let dry for 24 hours before using steam bath. Sealing Control For Surface Controls Only (SEC-XX, SEM-XX, SET-XX, SER-XX, SEC-NTS-XX, SEM-NTS-XX, SET-NTS-XX, SER-NTS-XX) 1/2" hole for surface mount Step 1: Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall. Completely seal the control to the wall so moisture does not collect behind it. Step 2: Place the control on the wall pressing firmly. (You may need to tape the control into place until the silicone dries.) Be careful not to harm the wall or control with the tape. Let dry for 24 hours before using steam bath. IMPORTANT: Fully test the control system prior to silicone. Surface Mount Control (shown) Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 97005_NC 4/16 6

6 Operation Signature Series Control Installation Instructions For More Operating Interactive Instructions please visit: www.thermasol.com/solutions A Taking a Steam Bath On your ThermaSol Signature Series Control, touch and release the power icon to power on. To turn off the steam unit touch and release the power icon once. B Setting or Changing the Temperature Set Point Press the or button until you reach the temperature menu. Press button. Set the temperature of your ThermaSol steam shower by using the or symbols, which are located immediately to the left and to the right of the Select/Return button. Press button. Increase the temperature by touching the UP symbol until desired temperature is displayed. Press Select/Return button. Reduce the temperature by touching the down symbol until desired temperature is displayed. Press Select/Return button. C Setting the timer Press the or button until you reach the time menu. Press Select/Return button. Set the timer of your ThermaSol steam shower by using the or button symbols, which are located immediately to the left and to the right of the Select/Return button. Press Select/Return button. User 1 & 2 Presets To preset user settings, press user button and makes changes, five seconds after control will save settings. Each User (1 & 2) has two settings - one for regular shower use and one for steam session use. Volume Short-Cut Press and hold or buttons for three second up or down arrows while in home menus. Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 97005_NC 4/16 7

7 Trouble Shooting and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on Signature Series Control Error Codes Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details. PN: 97005_NC 4/16 8

Steamhead Installation Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions From top: NTST-XX Traditional, NTSM-XX Modern, NTSC-XX Contemporary, NTSR-XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION

Steamhead Installation Instructions 2 Tools and Materials Parts enclosed Steamhead (Contemporary style shown here) Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fi tting! INSTALL steamhead as far as possible from the inshower controller. NEVER install the steamhead under controller A Silicone Installation instructions 3 Steamhead Location Install the steamhead 12" from the fl oor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible. i. For retrofit to existing finish wall: Drill a 2-1/2" diameter hole in the shower wall or wall above bathtub rim for the steam outlet roughin fi tting and install to be fl ush with the fi nished wall. (plumbing must be done from backside of fi nshed space) B Materials needed: Steamhead Steamhead Rough-In Housing 1/2" Copper Tubing (For PRO-650, PRO-850-3/4" drop elbow, 3/4" Copper Tubing 50' max. (2) 3/4" to 1/2" adapters) Silicone Other materials as required Connect a 1/2" NPT brass pipe or copper tubing to the steam outlet union (not included) on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough-in. For PRO-650 and PRO-850 run 3/4" copper steam line. It is very important that the pipe is fi rmly secured to the wall, so that when the steamhead is installed it doesn t push the rough-in fi tting back into the wall. Install a 1/2 dropear elbow on the end of the 1/2 pipe or tubing for the rough-in fi tting. For all the connections, use solder for copper joints and Tefl on tape for pipe fi ttings and do not over tighten fi ttings. DO NOT USE PVC CEMENT. For detail installation instructions of the steamhead please see Installation section in thermasol.com/customersupport Tools needed: 1" deep socket and ratchet 2 1/2" Masonry/tile/stone Hole Saw Upon fi nal installation mount steamhead with facing up to allow aromatherapy well to dispense steam. ii. For new framing: Mount and install rough-in fi tting to be fl ush with fi nished wall. A Aromatherapy Fill Channels Place silicone around groove Steamhead rough-in fi tting to be installed fl ush with fi nished wall B Parts provided by installer O-Rings Read warnings on page 3. For illustrative purposes only. Consult with qualifi ed professional for steam room construction details. PN: 97005_NC 4/16 10

Steamhead Installation Instructions 4 Steamhead Installation A B When fi nalizing installation, install the steamhead into the housing, making sure that the aromatherapy fi ll channels are facing upwards. To ensure that no moisture gets behind the steamhead and into the wall, place a generous bead of waterproof silicone around the steamhead, using the machined groove (located on the back of the steamhead) as a guide. C D Be sure there isn t any debris within the housing, and that the two O-rings are in place on the steamhead. Press the steamhead into the housing until the steamhead is tight against the fi nished wall. You may need to wipe away any excess silicone. A Make sure aromatherapy fi ll channels face up This edge must be fl ush with fi nished wall (+/- 1/8") D Finished wall B Place silicone around this groove Finished wall C O-rings 3.5".63" 3.5".63" 3.75".63" 3.75".63" Contemporary Traditional Modern Regency Read warnings on page 3. For illustrative purposes only. Consult with qualifi ed professional for steam room construction details. PN: 97005_NC 4/16 11

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 SUPPORT@THERMASOL.COM WWW.THERMASOL.COM WWW.THERMASOL.COM/SOLUTIONS 97005_NC 4/16