Krantz. HVAC systems for hospitals. System solutions

Similar documents
Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

C o o l i n g a n d h e a t i n g s y s t e m s

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Air distribution systems. Sidewall air outlets Turbulent mixing air flow

Air distribution systems. Opticlean OC-Q...

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air distribution systems. Air distribution systems for assembly rooms

Air distribution systems. Displacement air outlets Low-turbulence air flow in the commercial sector

Recirculated air ceiling for operating rooms made by Krantz Components

Displacement air outlets Low-turbulence air flow in the industrial sector. Air distribution systems

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

Product catalogue. Air Distribution Systems Cooling and Heating Systems Filter Systems and Dampers. Krantz A trademark of Caverion

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Ceiling diffusers. Type DLQL

Air distribution systems. Ceiling air outlets Turbulent mixing air flow

Units for suspended ceilings

KLIMA Active Chilled Beams

Displacement Ventilation

CRITICAL ENVIRONMENTS. Fully Integrated Systems for: Operating Rooms, Isolation Rooms & Pharmacies

Units for suspended cei lings

Ceiling air diffuser INDULTHERM INDULTHERM-e

Mediclean Complanate Ultra Clean Ventilation

Ceiling swirl diffusers

Ceiling swirl diffusers

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Space Air Diffusion II

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

VENTILATION SYSTEM COMPONENTS. Product Overview

DESCRIPTION OF TECHNOLOGY

ASSEMBLY HALL AIR DISTRIBUTION

Cooling ceiling technology

PREEVA air handling unit

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

German Products Suitable for low energy / sustainable buildings

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Polaris-I-60. active chilled beam. the future of space conditioning

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

System architecture. Air treatment Index

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Enriching Environments

CASSETTE UNIT. Comfort Circle

Discover the diversity of thermofer

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

LTG Air-Water Systems

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

CHILLED & HEATED CEILINGS

Halton Rex 600 Basic R6B - Active chilled beam

NEW. Group. Front loading models EcoStar 430 F / 530 F Pass-through model EcoStar 545 D. Dish- and glass washing machines of the EcoStar-Line

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Ceiling air diffuser INDULTHERM INDULTHERM-e

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

Smoke extract fan SMHA HATCH

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

mediclean Clean air systems in operating theatres

Volume control units

raymagic quad Installation, Operation & Maintenance Manual

Chilled ceiling panel INDUCOOL-Compact

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

MECHANICAL SERVICES 101. Ian White

New LED Product Offerings

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Thermal Comfort with Convective and Radiant Cooling Systems

... DF / IDF Gas fired combined heating and ventilation ...

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Flat-Screen TV Ceiling Mount - Short Pole - Full Motion

CHILLED ROOM AIR CURTAIN. IsolAir

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Halton CHB Active chilled beam with boost function for bulkhead installation

INCREASE YOUR LAB EFFICIENCY

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Modular Active. Chilled. Beams

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Air Management and Energy Savings with

LTG Air-Water Systems

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Cleanroom Technology. Complete solutions for pharmacies.

HIGH performance exchanger

HEAT RECOVERY AIR HANDLING UNIT

Unit heater with accessories

Halton Rex for Vario R6O - Variable air volume chilled beam

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

Dehumidification of indoor pools

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

DF-IDF air handling units

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Waterborne Climate Systems

The Tube Heater Principle

Transcription:

Krantz HVAC systems for hospitals System solutions

Best air management solutions through customized systems Krantz has been a leading specialist in comprehensive HVAC system solutions for more than 40 years, and has been supplying innovative ventilation and air-conditioning systems for hospitals and clean rooms for over 20 years. This overview presents air management solutions based on innovative systems designed to match any user requirements. We shall be glad to work out customized solutions together with you. Just contact us! Take advantage of our expertise and experience. Early dialogue with clients, investors, architects, and design consultants Very high level of quality, efficiency and reliability Ease of operation and maintenance of our systems Let us convince you of our creative approach to optimum design solutions. Visit our website www.krantz.de 2

Reception / Waiting area Pages 4 7 Examination / Treatment Operating area Pages 8 9 Regeneration Pages 10 11 Research / Teaching Laboratory, lecture hall, administrative area Pages 12 15 3

Reception / Waiting area The reception and waiting area is, so to speak, the business card of a building. Innovative air distribution systems in aesthetic design set new architectural trends while ensuring optimum thermal comfort. 4

Opticlean OC-Q Contact cooling ceiling system KKS-3/LD, for metal ceilings Thermal comfort coupled with attractive design The chilled sail AVACS is the result of further developments on our chilled sails. It combines the proven chilled ceiling technology with air diffusers that are invisible to room occupants. The exposed part of the AVACS chilled sail is an assembly of perforated rectangular metal tiles which incorporate the contact cooling ceiling system KKS-3/LD for metal ceilings. Nominal width: 1 200 mm Nominal length of each metal tile: 2 800 mm Suspension height: min. 150 mm Volume fl ow rate: 28 l/s [100 m 3 /h] Cooling output: up to 160 W/m 2 The Opticlean OC (with square or circular faceplate) has been developed in order to combine in a single product the main features of a ceiling-mounted supply air outlet for diffuse indoor air fl ow, i.e. high level of thermal comfort, unobtrusive integration into the suspended ceiling, very low amount of dirt accumulated on the ceiling, and low sound power level. Size OC-Q: 215 625 Size OC-R: 300 and 500 Discharge height: 2.5 4.5 m Volume fl ow rate range: OC-Q: 11 239 l/s [40 860 m 3 /h] OC-R: 25 170 l/s [90 610 m 3 /h] Temp. differential: 10 K Radiant cooling and heating ceilings provide a comfortable climate. KKS-3/LD is used for metal acoustic ceilings and KKS-4/GK for various types of gypsum board ceilings. PKS-D is used for plastered ceilings. Dimensions: variable Cooling output to EN 14240 ( t 10 K) KKS-3/LD: 116 W/m 2 KKS-4/GK: 89 W/m 2 PKS-D: 80 W/m 2 Heating output: > 100 W/m 2 is achievable ( t 15 K) Chilled sail AVACS 5

Adjustable induction outlet IN-V Swivel jet nozzle DW-V2 Diffuse indoor air flow and a multitude of design options Radial outlets RA-N3 are available with square or circular face. They generate high-quality diffuse air fl ow according to the principle of turbulent mixing ventilation. They can be installed free-hanging from the ceiling, above open grid or expanded metal ceilings, or fl ush with closed false ceilings or square tile ceilings. Adjustable induction outlets IN-V are linear ceiling air outlets that are eminently suited for installation in suspended ceiling systems in commercial buildings. Good visual integration into ceiling thanks to small width of visible air outlet profi le, in particular that of IN-V3 (only 15 mm wide). Swivel jet nozzles DW-V2 are used to aircondition large spaces or galleries with very high acoustic requirements. The discharge direction can be adjusted to any position in the horizontal and vertical planes. The jet discharge angle can be adapted to the desired operating conditions. Size: DN 355 and DN 500 Discharge height: 2.4 4.5 m Volume fl ow rate range: 26 400 l/s [95 1 440 m 3 /h] Temperature differential: 12 K to +5 K Element width: 15 or 28 mm Number of outlet rows: 1 4 Discharge height: 2.5 5 m Volume fl ow rate range: 2.8 110 l/(s m) [10 400 m 3 /(h m)] Nominal size: DN 60 to DN 250 Throw: 3 50 m Discharge height: 2.5 10 m Volume fl ow rate range: 11 589 l/s [40 2 120 m 3 /h] Adjustment: manual electric self-acting 6 Radial outlet RA-N3

Circular Opticlean OC-R Rectangular floor displacement outlet Q-BR The linear whirl outlet WL produces turbulent mixing ventilation. It can be installed in ceilings and walls. Applications are rooms with high acoustic and thermal comfort requirements, e.g. offi ces, restaurants, assembly rooms as well as lobbies and entrance halls. Discharge chamber height: 30, 45 and 65 mm Penetration depth: 4 16 m Discharge height: 2.6 6 m Volume fl ow rate range: 28 300 l/s [100 1 100 m 3 /h] Circular Opticlean OC-R with horizontal air discharge, for installation in suspended ceiling systems made from mineral fi bre or gypsum board. It is characterized by high level of thermal comfort, unobtrusive integration into the suspended ceiling, very low amount of dirt accumulated on the ceiling, and low sound power level. Sizes: 300 and 500 mm Discharge height: 2.5 4.5 m Volume fl ow rate range: 25 169 l/s [90 610 m³/h] Temp. differential: ±10 K The rectangular floor displacement outlet Q-BR is designed to deliver supply air to commercial rooms with raised fl oors or fl oor plenums. The air outlet generates a combined mixing/displacement fl ow or hybrid fl ow as described in the German guideline VDI 3804. The advantage of this hybrid fl ow over a mere displacement fl ow is a low vertical temperature gradient with lower air discharge temperature. Unit length: 800 1 900 mm Unit depth: 140 340 mm Unit height: 190 mm Volume fl ow rate: up to 55 l/(s m) [200 m 3 /(h m)] Grille: aluminium stainless steel wood Linear whirl outlet WL 7

Operating area Demanding requirements have to be complied with when designing and building a complete "operating room" system. During this process the protection of patients and staff is the centre of attention. Standards and guidelines provide safety. Our systems fulfil the requirements of DIN 1946-4 "Ventilation in buildings and rooms of health care" and are suited for all room classes (Ia, Ib and II) described therein. 8

Puri twist outlet PDK Fibre filter F Best treatment conditions Very often wall heating is necessary in operating rooms. The wall heating-cooling element WHK-GK is used in gypsum board walls, and the plaster system PKS-W is used in plastered walls. Dimensions: customizable Heating output to EN 14037 ( t 15K) WHK-GK: 84 W/m 2 PKS-W: 120 W/m 2 Cooling output: 30 W/m 2 ( t 8 K) The Puri twist outlet PDK for turbulent mixing ventilation, with HEPA filter, is suited for air cleanliness levels of Class 6 to 8 to EN ISO 14644-1 and Grade C and D to EU GMP guidelines as well as for treatment rooms of Class Ib to DIN 1946-4. The Puriclean PCK has the same properties as the Opticlean (p. 5) and is easy to clean. Size: DN 250 to DN 400 Discharge height: 2.4 4.5 m Housing height: 432 mm Volume fl ow rate range: 69 389 l/s [250 1 400 m 3 /h] The fi bre fi lters F and G are return air inlets for fi ltering textile fi bres out of the return air of clean rooms, particularly operating theatres and ancillary rooms; for wall or duct mounting. The fi bres are removed directly at the extract point. The fi bre fi lter is built into the wall of the clean room or exhaust air duct. Width x height: 225 x 225 mm to 825 x 825 mm Depth F / G: 61 / 75 mm Volume fl ow rate range: 65 1 670 l/s [230 6 000 m 3 /h] Wall heating-cooling element WHK-GK 9

Regeneration In medicine, regeneration means restoration of a body's normal function. During regeneration the organism tries to heal damaged tissue or organs by building new cells. To make the patients' stay less unpleasant, hospitals provide comfortable rooms with a cosy atmosphere. 10

Broad multiplex outlet BF-V Multiplex outlet FA-VT Ideal air quality and state-of-the-art solutions The adjustable wall slot diffuser WSD is a slim air outlet with aesthetic design. Since it requires little space, it is specially designed for installation in standard gypsum board walls. It generates turbulent mixing ventilation. The wall slot diffuser is particularly suitable for offi ces and rooms with concrete slab cooling. Nominal length: 525, 1 050, 1 125 mm Discharge height: 2.4 3.5 m Volume fl ow rate: up to 66.5 l/s [240 m 3 /h] per metre of diffuser length Temperature differential: 10 K to +6 K The broad multiplex outlet BF-V has been developed to fulfi l the high thermal comfort criteria required in commercial applications. The broad multiplex outlet is well suited to replace existing sidewall air outlets and air grilles. This is an optimum way to signifi cantly improve thermal comfort in rooms at low cost. Nominal length: 600, 800, 1 000 mm Mounting height: 2.2 4 m Volume fl ow rate range: 22 150 l/s [80 540 m 3 /h] Temperature differential: ±10 K The multiplex outlet FA-VT generates highturbulence mixing ventilation with spread-out air jets. The multiplex outlet is a sidewall air outlet whose front plate generates a large number of thin air jets through built-in jet bundle elements. The discharge direction of these elements being adjustable, the supply air jets can be spread out as required. Nominal length: 600, 800, 1 000 mm Discharge height: 2.5 4 m Volume fl ow rate single-row: 43 l/(s m) [155 m 3 /(h m)] double-row: 50 l/(s m) [185 m 3 /(h m)] Temperature differential: ±12 K Wall slot diffuser WSD 11

Laboratory, lecture hall, administrative area In a hospital the requirements for the ambient air conditions are very different depending on the building areas. For instance, hospital pharmacies and laboratories, which deal and work with substances that are hazardous to health, require specific air distribution systems that will ensure the protection of people and medicines. Lecture halls and seminar rooms must accommodate a great number of people. The indoor air quality and the acoustic performance of the air-conditioning systems are of vital importance for occupant comfort and learning success. Even in rooms where the risk of infection is low, e.g. in the administrative area, the indoor air quality has to be brought to a level that is conducive to good health. 12

Radial slot outlet RL Puriclean PCK Customized systems to meet the most varied demands The dissection outlet SZ is a displacement outlet which is placed above the dissection table and discharges a laminar fl ow of supply air into the dissection zone. The air pollutants are thus displaced downwards and the polluted air is extracted at fl oor level. Length x width: 2 120 x 1 130 mm Height: 300 mm (standard) Volume fl ow rate range: 210 280 l/s [750 1 000 m 3 /h] Lighting intensity: > 1 100 Lux The radial slot outlet RL generates turbulent mixing ventilation and is used for supply air distribution in commercial buildings. It is particularly suitable for rooms with high indoor air fl ow requirements and can be installed fl ush with the ceiling or free-hanging. Size: 300 800 Discharge height: 2.5 4.5 m Volume fl ow rate range: 20 330 l/s [75 1 200 m 3 /h] Temperature differential: 12 K to +5 K Discharge direction: 2-, 3- or 4-sided The Puri twist outlet PDK for turbulent mixing ventilation, with HEPA fi lter, is suited for air cleanliness levels of Class 6 to 8 to EN ISO 14644-1 and Grade C and D to EU GMP guidelines. The Puriclean PCK has the same properties as the Opticlean (p. 5) and is easy to clean. Nominal size: DN 250 to DN 400 Discharge height: 2.4 4.5 m Housing height: 432 mm Volume fl ow rate range: 69 389 l/s [250 1 400 m 3 /h] Dissection outlet SZ 13

Induction outlet with preset discharge direction IN-N6 Adjustable radial outlet with core tube RA-V2 High air quality and many system configurations Step displacement outlets Q-SR and Q-SL are used to supply air to assembly rooms with seating arranged on stepped fl oors, such as auditoria, convention centres, theatres, etc. They operate according to the principle of displacement ventilation and are designed for installation in step risers, directly behind the seats. Nominal size circular: DN 80 and DN 100 rectangular: variable Volume fl ow rate DN 80: 10 l/s [35 m 3 /h] DN 100: 16.5 l/s [60 m 3 /h] rectangular: 21 l/(s m) [75 m 3 /(h m)] The induction outlet with preset discharge direction IN-N6 is a linear ceiling air outlet that is eminently suited for installation in suspended ceiling systems in commercial buildings. The discharge element has a number of consecutive jet channels which are inclined at a 45 angle to the horizontal, alternately to the right and to the left. This enables alternate air discharge. Length: 1 000 1 600 mm Discharge height: 4 7 m Volume fl ow rate range: 28 85 l/(s m) [100 300 m 3 /(h m)] Temperature differential: 10 K to +6 K The adjustable radial outlet with core tube RA-V2 generates a diffuse air fl ow according to the principle of turbulent mixing ventilation and is particularly suited for large thermal load variations in commercial applications as well as for great ceiling heights. The direction of the supply air jets is adjustable from horizontal to vertically downwards, depending on the supply air temperature. Nominal size: DN 250 to DN 900 Discharge height: 2.8 18 m Volume fl ow rate range: 83 3 055 l/s [300 11 000 m 3 /h] Temperature differential: ±12 K Adjustment: manual electric self-acting 14 Step displacement outlet Q-SL

Chilled beam DK-LIG/Z, with ventilation function, two-sided discharge Ventilation unit (supply/return air) for mixing ventilation LG-ZA-M-SB, for vertical parapet mounting The static cooling ceiling system SKS-5/3 comes into use as exposed ceiling elements having an attractive linear-panel appearance. This system can be designed as free-hanging chilled sail or chilled island. The chilled beam DK-LIG, with ventilation function and one-sided or two-sided discharge, is used for room cooling and heating in commercial buildings. High cooling outputs and fresh air supply to enhance the indoor air quality. The ventilation unit LG-ZA-M-SB is designed for integration into the parapet of a facade. It enables ductless ventilation as it is fi tted with direct outdoor and exhaust air connections. It provides the following functions: fresh air supply, cooling, heating, operation with heat recovery, and operation with recirculated or outdoor air. Nominal width: up to 1 480 mm Nominal length: up to 4 000 mm Cooling output: up to 160 W/m 2 Nominal width: 300 and 600 mm Nominal length: up to 3 000 mm Primary air volume fl ow rate: 3 25 l/(s m) 10 90 m 3 /(h m) Cooling output: up to 820 W/m Width: 1 000 mm Height: 650 mm Depth: 297 mm Volume fl ow rate: max. 53 l/s [190 m 3 /h] Total cooling output: 720 W Total heating output: 1 200 W Static cooling ceiling system SKS-5/3, for visible installation 15

Caverion Deutschland GmbH Business Unit Krantz Uersfeld 24, 52072 Aachen, Germany Phone +49 241 441-1 Fax +49 241 441-555 info@krantz.de www.krantz.de Krantz A Trademark of Caverion