INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Similar documents
INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

BACKUP BATTERY INSTALLATION INSTRUCTIONS

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

CDL8 LED Architectural

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Bdl60u Fluorescent Emergency Ballast

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

WPLED 26W INSTALLATION INSTRUCTIONS

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

Installation Guide for models:

Operator: Save these instructions for future use!

SERVICE BY QUALIFIED PERSONNEL ONLY

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Honeywell Durafit LED Retrofit Kit

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Installation Guide for models:

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Cold Door 2 LED Retrofit Kit Lighting System

MaxLite LED Vapor Tight Linear Fixture

ESRB and ESRN Installation & Safety Instructions

Innovative Lighting R-Series Vertical Refrigeration

LED Emergency Battery Backup

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Innovative Lighting R-Series Overhead LED Conversion Kits

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

SP-1000X. Panic Device Power Controller Installation Guide. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Rack Mount Series Installation Guide

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

1 x4 Dimmable LED RetroFits

Operator: Save these instructions for future use!

30-YEAR LIMITED WARRANTY

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

HOT FOOD DISPLAY Technical Service Manual

CEILING FAN OWNER'S MANUAL

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Installation Instructions

Dioluce Products Installation Instructions

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Installation Instructions

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Smart-Wall TV Kit - Installation & Operation Instructions -

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

USER MANUAL. Adventure Kings 50L Refrigerator

FerronTM. Instruction Manual A Kichler Decor ceiling fan

LED IMPORTANT SAFETY INSTRUCTIONS

MaxLite LED Round Pendant Highbay Series

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Q7800H Integrated Burner Control Subpanel

CEILING FAN OWNER'S MANUAL

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

HIGH BAY APPLICATIONS

Electric Heat Accessory Installation Instructions

INSTALLER S & OWNER S MANUAL

SCHWAN INSTALLATION GUIDE

USER MANUAL. Adventure Kings WiFi Refrigerator

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Operator: Save these instructions for future use!

Table of Contents. What to Expect with. Mounting Options. Tools Needed

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

Please Keep This Manual For Future Reference REV.01

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation Instructions

Installation Instructions

New Silent Alert Fire Safe System

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Smart Temp. Model

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Transcription:

LED EMERGENCY DRIVER PS1055LCP & PS1555LCP INSTALLATION INSTRUCTIONS READ AND FOLLOW THESE INSTRUCTIONS BEFORE INSTALLATION TO ENSURE PROPER AND SAFE OPERATION SAVE THESE INSTRUCTIONS LED EMERGENCY DRIVER COMPATIBLE WITH THE LED LOADS LISTED IN SPECIFICATIONS. FOR OTHER LED LOADS CONTACT THE FACTORY. 1-888-300-7017 www.acuitybrands.com When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS WARNING Dual Power Supply - Risk of Shock Hazard Even if AC Power is OFF. Disconnect Test Switch / Pilot Light and Battery connector before servicing fixture. DO NOT mount near a gas or electric heater. CAUTION Before wiring to power supply, turn off electricity at fuse panel or circuit breaker. Service by Qualified Personnel Only. De-energize before opening. DO NOT attempt to service the battery. It is not field replaceable. DO NOT use in hazardous locations. DO NOT use this product outdoors. DO NOT use this product in air handler heated outlets. DO NOT use accessory equipment not recommended by the manufacturer. DO NOT use this equipment for other than its intended use. IMPORTANT SAFEGUARDS Consult your local building code for approved wiring or installation. The LED Emergency Driver must be connected to an unswitched AC power source of 120 to 277 Vac. This product is for use with indoor and damp rated fixtures. Where the ambient temperature is 5 C minimum, +50 C maximum. This product is for use with LED load voltage between 15V to 55V for PS1055LCP & 20V to 55V for PS1555LCP. Equipment should be mounted in a location and at heights where it will not readily be subject to tampering by unauthorized personnel. Make sure that the branch circuits are derived from a common phase for both normal lighting LED drivers and the LED Emergency Driver prior to installation. When used with a switched fixture, it is important that the power to the LED Emergency Driver must be provided by an unswitched circuit. LED Emergency Drivers are for factory and field installation. They are not field serviceable. Allow LED Emergency Drivers to charge 24 hours before initial and full discharge testing. Do not locate the Test Switch / Pilot Light or route cable within 1 inch of the fixture LED Modules. Emergency lighting system should be tested per all of the required tests and as often as local codes require or at least monthly to ensure all components are operational. LED CLASS 2 CONTAINS LIFEPO 4 RECHARGEABLE BATTERY. MUST BE RECYCLED OR DISPOSED OF PROPERLY. Page 1 of 5

LED Emergency Driver Components 5 Installation Step 1 - Install LED Emergency Driver 6 1. Turn off all external power to the luminaire. 4 2. Inspect LED Emergency Driver 1 and make sure the TS/PL 8 is not connected. If so, disconnect it before 7 installation of the LED Emergency Driver. 3. Place the unit on the mounting surface and fasten 1 3 2 11 10 Fig 1 8 9 through the mounting slots 2 using serrated head screws (U3840). 4. Refer to the wiring diagram. Connect Input/Output wires to the LED module and AC input power as indicated in the wiring diagram. Make sure all connections are in accordance with NEC and any other local requirements. 5. CAUTION: Cap LEDCODE wires if unused. Component Descriptions Step 2 - Install Test Switch / Pilot Light (TS/PL) 1 LED Emergency Driver 2 Mounting Slots 3 AC Wires 4 Adapter Harness 5 (TS/PL) Socket 6 Load Socket 7 (TS/PL) Connector 8 Test Switch / Pilot Light (TS/PL) 9 (TS/PL) Mounting Clip 10 (TS/PL) Label 11 SD Status Indicator Sticker 1. Identify a suitable location for the TS/PL 8 and cable that is at least 1 inch from the fixture LED Module and is visible outside the fixture lens. 2. Drill or punch a ½ inch diameter hole in the fixture wall or use a Remote TS/PL (ELA TSPLP SD) for location up to 25 feet away. 3. Insert one side of TS/PL 8 into the hole from the inside of the fixture housing until it snaps in place. 4. Slide TS/PL Mounting Clip 9 firmly to lock and secure the TS/PL assembly. 5. Mark the TS/PL location on the fixture with the TS/PL Label 10 and apply the SD status Indicator Sticker 11 to the TS/PL location. 6. Connect and fully engage the TS/PL Connector 7 to the TS/PL Socket 5. Ensure the TS/PL Connector is properly seated in the TS/PL Socket. Page 2 of 5

Step 3 - Installation Inspection Apply continuous AC power to LED Emergency Driver. Prior to operation of the LED Emergency Driver in normal service perform the following installation inspections. Charge LED Emergency Driver at least 1 hour before doing a functional test. Allow 24 hours for full rated performance of the LED Emergency Driver. 1. Check the equipment rating to be sure the LED Emergency Driver will receive the proper line voltage. 2. Be sure the TS/PL pilot lamp is on. The lamp will show Red for low battery, Green for sufficient battery charge. If not see Troubleshooting Section. 3. Press TS/PL test button for two seconds. The pilot light will blink. Within 5 seconds, the LED Module should then be operating at a reduced light output. 4. The test mode runs for 30 seconds. To exit test mode earlier, press the TS/PL for two seconds. 5. If the LED Module in the fixture returns to normal operation, the fixture is ready for normal and emergency service. If not, see Troubleshooting Section. Troubleshooting Problem Emergency LED Module does not operate when TS/PL Button is pressed TS/PL Charging LED not on Possible Cause 1. Incorrect wiring of the LED Emergency Driver and/or LED Driver 2. Use of a LED Module not listed as compatible with the LED Emergency Driver 3. Battery not charged at least 1 hour 4. TS/PL not inserted properly to the LED Emergency Driver socket 5. Wrong TS/PL 1. AC Power is Off 2. TS/PL not inserted properly to LED Emergency Driver socket 3. Wrong TS/PL Normal and Emergency Operation During normal operation AC power is applied and the charging indicator light is illuminated indicating the battery is charging. When the power fails, the LED Emergency Driver automatically switches to emergency power from the LiFePO 4 battery that will operate the LED Module for a minimum of 90 minutes. When the AC power is restored, the LED Emergency Driver switches the fixture back to the normal mode within 10 seconds. Fixture does not operate in the Normal mode LED Emergency Driver does not operate LED Module in the emergency mode for at least 90 minutes 1. Incorrect wiring of the LED Emergency Driver and/or LED Driver 2. AC power off to the LED Driver 1. Battery not fully charged 2. LED module not within LED Emergency Driver specifications. 3. Battery at end of life SPECIFICATIONS NORMAL OPERATION INPUT AMPS MODEL NO. 120 Vac 277 Vac MAX. CHARGE AMPS MINIMUM VOLTS EMERGENCY OPERATION MAXIMUM VOLTS (OC) BATTERY AMPS, MAX PS1055LCP 0.08 0.10 0.213 15 55 1.20 PS1555LCP 0.09 0.11 0.211 20 55 1.04 Page 3 of 5

SELF-DIAGNOSTIC MODULE SPECIFICATIONS Designed to perform self-diagnostics testing for five minutes every month, and ninety minutes every 12 months. Testing includes AC to DC transfer evaluation, battery condition and emergency load operation. Self-diagnostics work in conjunction with Test Switch/ Pilot Light (TS/PL) assembly. Any detected failures will be indicated by flashing of the bicolor LED. See Diagnostic key for additional details. DIAGNOSTIC KEY CONDITION Normal Mode Self-testing Emergency mode Insufficient charge Battery pack failure Emergency lamp failure Fixture diagnostic failure detected Temperature out of range = STATUS INDICATION Steady green or Steady red Flashing green Off Flashing red/green Single-flash red Double-flash red Triple-flash red Quadruple - flash red PERIODIC MAINTENANCE If the automated compliance testing function is disabled, Emergency lighting system should be manually tested as required by NEC and local code. 1. Periodically test the emergency lighting system by pressing the TS/PL test button. 2. Check the system LED Module to ensure that it operates in both the normal AC and emergency modes. 3. Ensure the Green LED charging light is on when the AC power is on. The lamp will show Red for low battery, Green for sufficient battery charge. LED EMERGENCY DRIVER SHIPPING / POWERING DOWN The LED Emergency Driver may be completely powered down by removing AC power AND performing one of the following steps: OR Press and hold the TS/PL for approximately five seconds until LED Module shuts off. This function can only be performed during the first thirty seconds of Emergency mode. Unplug TS/PL in emergency mode. Page 4 of 5

Wiring Diagram READ ALL SAFETY INSTRUCTIONS AND IMPORTANT SAFEGUARDS PRIOR TO WIRING AND INSTALLATION MOUNTING HEIGHT The maximum luminaire mounting height is 8 feet unless otherwise determined by the end product or validated at the installation site to meet national and local electric codes. www.acuitybrands.com 1-888-300-7017 INSTALLATION INSTRUCTIONS PS1055LCP & PS1555LCP Part Number 912-00019-002 Rev A 07/12/17 Page 5 of 5