TWINFLOW STDR Installation & Maintenance

Similar documents
RAPTOR SPA Installation & Maintenance

POWERPLUS SPP Installation & Maintenance

RAPTOR COOLER SRC Installation & Maintenance

MINIFLOW SMF Installation & Maintenance

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

HIT Centrifugal In-Line Fan

GORILLA HVLS Installation & Maintenance

POWERPLUS SPP Product Brochure

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

SAX. Window & Wall Fans

Installation and Wiring Instructions

XB-EFA-8L-BK & XB-EFA-8R-BK

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Installation manual Mori HR

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

GIVE A FAN A CHANCE Installation Dos & Don ts

HHWCH51 Galvanised Hot Water Coil Heater

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Installation & User Instructions:

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Centrif Duo & Centrif Duo Plus

AP-EH500-L/RQA9837. Installation Guide


INSTALLATION, OPERATION & MAINTENANCE MANUAL

Lo-Carbon T-series Window & Roof Models

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Lo-Carbon Quadra Centrifugal Fan

Whole Room Dryer WRD, WRD/110

OPERATION AND MONTAGE MANUAL ROOF FANS

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Swaging Machine Type H50-46ECO

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

OPERATION AND MONTAGE MANUAL ROOF FANS

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

2 IN 1 JUICER AND BLENDER

JMP Series Plate Mounted Axial Flow Fans

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

SUPER T WALL FANS. Installation and Wiring Instructions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

LOWERING THE COST OF HIGH CEILINGS

Purge Ventilation Unit. Product Manual. ventilation systems TP625

AIR CURTAIN T SURFACE MOUNTED RANGE

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

EVG Extractors. Manual for Installation, Use and Maintenance

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Lo-Carbon Quadra SELV

AIR CURTAIN HX RECESSED RANGE

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Panel Fan Series Operators Manual (Galvanized and Polymer)

Simply Silent Contour 4 (100mm) Axial Extraction Fan

BSK-RPR Fire Damper. Additional operating instructions according to

DEVIL CERAMIC SPACE HEATERS

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Silhouette Installation and Wiring Instructions

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

AHU INSTALLATION & OPERATION MANUAL

ISCG90SS _03 ISCG90SS

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

BKA-EN Fire Damper. Additional operating instructions according to

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

PERFORMANCE SLIMMING BELT

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Xpelair Simply Silent DX150

Multi-Elec COMPACTE BOILER

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

ART cm Island Curved Glass

Spiral Dough Mixer. Instruction manual. Model: CP821

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Transcription:

TWINFLOW STDR Installation & Maintenance These instructions must be read fully before commencing installation 535-IOM0039 Issue A

Installation Instructions AC EC 1.0 GENERAL 1.1 It is important these Installation and Maintenance Instructions are fully adhered to. 1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail contact Elta Fans Ltd or its agents for clarification. 1.3 All electrical installation must be carried out by suitably qualified and competent personnel in accordance with all current statutory requirements. 1.4 These instructions cover only the Elta Fans Ltd product and do not include the supply or installation of any safety equipment that may be required e.g. adequate guarding or protection from rotating parts and proper electrical isolation. 1.5 Any declarations made by Elta Fans Ltd about product installation and safety, are dependant on the fan equipment being used within installations which themselves meet the requirements of the relevant Standards and Directives of your region. 1.6 The fan is designed for use in an ambient temperature of -20 C up to +60 C and up to 95% relative humidity. The fan is not suitable for corrosive or explosive atmospheres. 1.7 The installer should provide easy access to the fan to facilitate future maintenance. 1.8 The installer should ensure the fan is adequately supported. 1.9 This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for their safety. Children should be supervised to ensure that they do not play with the product. 1.10 At end-of-life, the unit must be disposed of in an environmentally friendly manner by suitably qualified and competent personnel in accordance with the requirements of applicable Standards and Directive 2.0 INSTALLATION WARNING The fan must be isolated from the power supply during installation and maintenance. The fan must be earthed in accordance with the local regulations. 2.1 Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that the impeller is free to rotate. 2.2 If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to the installation. 2.3 The fan must be securely mounted in the desired position to suit the application. The fan is only suitable for horizontal mounting. 2.4 Check the details on the motor rating plate to ensure that the correct power supply (voltage, frequency and phase) is available. An incorrect power supply will lead to permanent damage to the fan motor. 2.5 Refer to the appropriate wiring diagram. Ensure that all earth connections are made. 2.6 Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical regulations. 2.7 Precaution must be taken to locate the exhaust discharge terminal so as to avoid the backflow of gases into the room from the open flue of gas or other fuel burning appliances. 3.0 START-UP 3.1 Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram. 3.2 At initial start-up, check that impeller rotation and airflow direction is correct. 3.3 Check that the motor amperage draw does not exceed the nameplate rating. 4.0 FAN MAINTENANCE 4.1 Inspection of the fan at least once every 12 months is recommended to ensure that the motor, fan blades, and supporting guards, are clean. Any build up of dust and deposits on the blades or guards should be removed using a non-abrasive cleaner. 4.2 All fastenings should be checked for tightness. In addition, all rotating items should be checked. 4.3 Bearings are of the sealed for life type and will not need a detailed inspection. WARNING STDR fans are fitted with an auto-reset thermal contact which switches the fan off in the event of a fault condition. Once the motor cools down the fan may start unexpectedly. Fuses /circuit breakers are used to provide short circuit protection only. A starter panel with overload protection should be used to protect the motor. Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 2

Installation Instructions AC EC Table 1: Operational Maintenance Product Code Wiring Diagram No. Inspect AV mounts for Corrosion or Sag 6 months Check earth bonding 6 months Dampers check rubber stops and grease (lithium based) pivot points, by removing plastic caps Yearly Check fixings tightness and conditions of brass track and rivets Inspect and clean impeller Remove dirt from motor cooling fins Check operation of anti-condensation heaters Check for even tip clearance between impeller and casing For ATEX 10% of motor shaft diameter with 2mm minimum and 13mm maximum. Check motor Amps Any corrosion - treat with suitable chemicals Check casing seals Table 2: Terminal Box Maintenance Activity Frequency Check that lid seal is in place and not damaged Each time the enclosure is opened Check that lid fixing screws are in place and secured Each time the enclosure is closed Check that the mounting bolts are tight and free from corrosion Check security of all cable glands Check that all screw clamps terminals are secure Check enclosure for damage Annually Annually Annually and each time enclosure is opened Annually 5.0 STORAGE 5.1 If the fan is not to be used immediately then it should be stored in a clean, dry, vibration free and lockable location. 5.2 The impeller must be spun by hand (ensuring that it does not come to rest in the same position) on a monthly basis to prevent hardening of the grease and possible damage to the bearings. 5.3 All items to be stored on pallets that afford adequate protection from damage, dust and high humidity. 5.4 If storage periods of longer than 1 month are anticipated then Elta (or their Agent) should be contacted prior to storage taking place, to ensure the storage area provisions will not be detrimental to the well being of Elta products. 6.0 GUARANTEE Elta Fans Ltd will, free of charge, within a period of 1 year from the date of dispatch from their works, repair or at its option replace any goods which are proved to have defects as a result of defective materials or workmanship. The goods MUST be returned to Elta Fans Ltd carriage paid for examination. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 3

Wiring Diagram No. AC EC Product Code Wiring Diagram No. STDR200-1AC 152-2177 STDR250L-1AC 152-2177 Product Code Wiring Diagram No. STDR200-1EC 152-000236 STDR250L-1EC 152-000236 STDR250H-1EC 152-000236 STDR315-1EC 152-000244 STDR400-1EC 152-000244 STDR500-1EC 152-000244 STDR500-3EC 152-2MOEA03K3 Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 4

Notes Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 5

Notes Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 6

EC Declaration of confirmity/incorporation Herewith we declare that the air movement equipment below, on the basis of its design and construction in the form brought onto the market is in accordance within the relevant health and safety requirements of the EC Directive for use of machinery. EC Declaration of Conformity EC Declaration of Incorporation In accordance with the Machinery Directive 2006/42/EC Designation of Equipment: Raptor, Compact, Powerplus, Revolution, Miniflow, Multiflow, Viper, Jetflow, Jetstream, Hideaway, Singleflow, Quietflow, Twinflow, Powerduct, Qube, Slim-Qube, Skyflow, Heritage, Biflow, Zoo Fan, Ceiling Fan, SmokeVent, Pedestal, Window/Wall, Ezifit Type: SPA, SDA, SCP, SCPA, SCD, SCPP, SPP, SLC, SAMF, SMB, SMC, SMT, SCC, HIT, SJS, SH, SSD, SQS, SQSDCV,STD, SQT, SQTDCV, SPD, SQU, SQU-HT, SSQU, SSR, SSF, SSMF, SMF, SSDR, SSDRD- CV, STDR, STDRDCV, SGE, SCH, SCHT, SSFV, SSRV, SSC, SB, SDF, HCF, HPFA, HWFA, SRC, SAX, SRE, SEIE, SEWE Low Voltage Directive2006/95/EC Electromagnetic Compatibility (EMC) Directive 2004/108/EC Energy-Related Products (ErP) Directive 2009/125/EC Herewith declare that the air movement equipment below, on the basis of its design and construction as partly completed machines brought onto the market is in compliance within relevant health and safety requirements of the EC Directives stated above. In the event that alterations are made to the machinery without prior consent with the manufacturer, this declaration becomes invalid. Designation of Equipment: Raptor, Compact, Powerplus, Revolution, Miniflow, Multiflow, Viper, Jetflow, Jetstream, Hideaway, Singleflow, Quietflow, Twinflow, Powerduct, Qube, Slim-Qube, Skyflow, Heritage, Biflow, Zoo Fan, Ceiling Fan, SmokeVent, Window/Wall, Ezifit Type: SPA, SDA, SCP, SCPA, SCD, SCPP, SPP, SLC, SAMF, SMB, SMC, SMT, SCC, HIT, SJS, SH, SSD, SQS, SQSDCV,STD, SQT, SQTDCV, SPD, SQU, SQU-HT, SSQU, SSR, SSF, SSMF, SMF, SSDR, SSDRD- CV, STDR, STDRDCV, SGE, SCH, SCHT, SSFV, SSRV, SSC, SB, SDF, HCF, SEIE, SEWE The design of the partly completed machines listed below complies with the Essential Health and Safety Requirements (EHSRs) of ANNEX I, sections 1.1.2, 1.1.5, 1.4.1, 1.5.1 in EC Machinery Directive 2006/42/ EC The partly completed machines comply with the requirements of :- Low Voltage Directive 2006/95/EC, Electromagnetic Compatibility (EMC) Directive 2004/108/EC, Energy-Related Products (ErP) Directive 2009/125/EC The machinery is incomplete and must not be put into service until such time as the machinery which is partly complete is to be incorporated and has been assessed and declared in conformity with the provisions of the Machinery Directive 2006/42/EC. We undertake to transmit, upon reasoned request by appropriate national authorities, relevant information on the partly completed machinery identified above. Manufacturer: Elta Fans Limited 17 Barnes Wallis Road Segensworth East Industrial Estate Fareham, Hampshire PO15 5ST, UK Date / Signature of Manufacturer: Date: 20th May 2013 Name / Position of Signatory: Mr. Robert Rees Q.A.Manager Elta fans Ltd Issue A Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 7

Applied Technology Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: at@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom Building Services Tel: +44 (0) 1384 275800 Fax: +44 (0) 1384 275810 Email: bs@eltafans.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom Export Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: export@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom www.eltafans.com BS EN ISO 9001:2008 FM 556465 A member of HEVAC ASSOCIATION