CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

Similar documents
CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

Certificate: _01 / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 9 September 2014

Certificate: _02 / 9 September 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 2 February 2015

Certificate: / 9 February 2011

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 29 April 2014

Certificate: _02 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 20 August 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 19 August 2011

CERTIFICATE of Product Conformity (QAL1)

_03 / 28 July 2015

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CONFIRMATION of Product Conformity (QAL1)

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

This document is a preview generated by EVS

Complete Gas Analysis

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

continuous emissions monitoring Combustion & Environmental Monitoring

including the locations according to annex

International comparison of validation methods for dust concentration measurement

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Datasheet: K-22 LO Sensor

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Automation, Software und Informationstechnologie

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

ALTAIR 5X Multigas Detector Product Specification

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Glenside Environmental Services Ltd

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

NO NO 2 NO x SO 2 CO CO 2 O 2

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

PCT Workshop Before you leave the office

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Product data sheet Palas Fidas 200 S

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Supplementary Installation and Operating Instructions. Category II2G

Universal Gripper UG 16, UG 18. Operating Instructions

Shipboard incinerators with capacities up to 4000 kw

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

PED Workshop Nicosia, 3-5 October, 2005

WIO200 Water In Oil measuring instrument

FIDAS FINE DUST MONITORING SYSTEMS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Declaration of conformity - Safety relays 14:2. Declaration of conformity - JSBR4 14:3. Declaration of conformity - Vital 1 14:4

This document is a preview generated by EVS

Product- and Environment Data Sheet Page: 1/5 Date: Date of revision:

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

OPTIBAR DP 7060 Supplementary Instructions

Transcription:

Umwelt Bundes Amt @ For our Environment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000035010 Certified AMS: : Test Institute: with analysing module CMA-5800 for NOx. S0, CO, co and 0 Kaplanstr. 5 3430 Tulln Austria Energie und Umwelt GmbH This is to certify that the AMS has been tested and found to comply with: EN 1567-1: 009, EN 1567-: 009, EN 1567-3: 008 and EN 14181: 004 Certification is awarded in respect of the conditions stated in this certificate (see also the following pages). ~-.t~ tuv.c 0 / A ~~ - - ::;. luvrheinland ::;: ~ ~ 1:>... ~ ooooo~l5\) Publication in the German Federal Gazette (BAnz.) of 0 March 01 Umweltbundesamt Dessau, 16 March 01 EN 1567-3 tested QAL 1 certified TUV approved Annual inspection The certificate is valid until: 01 March 017 Energie und Umwelt GmbH Köln, 15 March 01 i.~li:ns~achim Hummel ppa. Dr. Peter Wilbring www.umwelt-tuv.de I www.eco-tuv.com teu@umwelt-tuv.de Tel. +49 1 806-756 TUV Rheinland Energie und Umwelt GmbH Am Grauen Stein 51105 Köln Accreditation accordinq to EN ISOliEG 1705 and certified accordinq to ISO 9001:008. qa11.de info@qal1.de page 1 of9

: of 18 October 011 First certification: 0 March 01 Validity ends: 01 March 017 Publication: BAnz. 0 March 01, No. 36, p. 90, chapter I, No. 4.5 Approved application The tested AMS is suitable for use at combustion plants according to EC directive 001-80-EC, at waste incineration plants according to EC directive 000-76-EC and other plants requiring official approval. The tested ranges have been chosen with respect to the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a five months field test at a municipal waste incinerator. The AMS is approved for an ambient temperature range of +5 C to +40 C. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: test report dated 18 October 011 of Energie und Umwelt GmbH suitability announced by the German Environmental Agency (UBA) as the relevant body the ongoing surveillance of the product and the manufacturing process publication in the German Federal Gazette (BAnz. 0 March 01, No. 36, p. 90, chapter I, No. 4.5, announcement by UBA from 3 February 01) qal1.de info@qal1.de page of 9

AMS name: with analysing module CMA-5800 for NO x, SO, CO, CO and O :, Tulln, Austria Field of application: For measurements at plants requiring official approval (i. e. plants in 000-76-EC, waste incineration directive and 001-80-EC large combustion plants directive) Measuring ranges during the suitability test: Component Certification range supplementary Unit measurement ranges NO x 0 153 1) 0-1530 ) mg/m³ SO 0-75 0-750 mg/m³ CO 0-50 0-500 mg/m³ CO 0-0 0-5 Vol.-% O 0-5 0-10 Vol.-% 1) as NO, this corresponds to app. 0 100 mg/m³ NO ) as NO, this corresponds to app. 0 1000 mg/m³ NO Software version: P1000877001I Restrictions: None Note: A four weeks period has been specified as maintenance interval with a reservoir size of 40 l for the phosphoric acid. : Energie und Umwelt GmbH, Köln Report No.: dated 18 October 011 qal1.de info@qal1.de page 3 of 9

Certified product This certificate applies to automated measurement systems confirming to the following description: The measuring system is a multicomponent gas analyser for the measurement of emissions. The analyser of the type series is a measuring device to observe continuously the concentration of NO x, SO, CO, CO and O at stationary emission sources. It measures simultaneously the five above listed gas components. The system measures the concentration of the components NO x, SO, CO, CO and O in dry conditions because the moisture from the measuring gas is removed with help of sample gas chillers. For the measuring channels NO x, SO, CO and CO the non-dispersive infrared ray absorptiometry with cross modulation system (NDIR) is used. For the determination of the oxygen concentration a magneto-pneumatic system (MPA) is applied, which is free from cylinder gas as a carrier gas. For the minimisation of the SO losses in the sample conditioning system a 10 percent phosphoric acid is added upstream of the sample gas chiller into the hot sample gas. General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 1567. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, Energie und Umwelt GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of Energie und Umwelt GmbH. With revocation of the publication the certificate looses its validity. After the expiration of the validity of the certificate and on requests of the Energie und Umwelt GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and the validity is also accessible on the internet Address: qal1.de. Certification of with analysing module CMA-5800 for NO x, SO, CO, CO and O is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Initial certification according to EN 1567 Certificate No. 0000035010: 16 March 01 Validity of the certificate: 01 March 017 : of 18 October 011 Energie und Umwelt GmbH, Köln Publication: BAnz. 0 March 01, No. 36, p. 90, chapter I, No. 4.5: Announcement by UBA from 3 February 01 qal1.de info@qal1.de page 4 of 9

NDIR 011-10-18 Measured component NO Certification range 0-100 mg/m³ Sum of positive CS at zero point 1.30 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at reference point 3.00 mg/m³ Sum of negative CS at reference point 0.00 mg/m³ Maximum sum of cross sensitivities 3.00 mg/m³ Uncertainty of cross sensitivity 1.73 mg/m³ Standard deviation from paired measurements under field conditions * u D 0.37 mg/m³ 0.138 (mg/m³)² Lack of fit u lof 0.173 mg/m³ 0.030 (mg/m³)² Zero drift from field test u d,z -0.543 mg/m³ 0.95 (mg/m³)² Span drift from field test u d,s -1.547 mg/m³.393 (mg/m³)² Influence of ambient temperature at span u t 0.954 mg/m³ 0.910 (mg/m³)² Influence of supply voltage u v 0.580 mg/m³ 0.336 (mg/m³)² Cross sensitivity (interference) u i 1.73 mg/m³ 3.000 (mg/m³)² Influence of sample gas flow u p 0.04 mg/m³ 0.04 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.808 mg/m³ 0.653 (mg/m³)² Converter efficiency for AMS measuring NOx u ce 1.900 mg/m³ 3.610 (mg/m³)² Combined standard uncertainty (u C) u c 3.38 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 6.6 mg/m³ Relative total expanded uncertainty U in % of the ELV 131 mg/m³ 5.1 Requirement of 000/76/EC and 001/80/EC U in % of the ELV 131 mg/m³ 0.0 Requirement of EN 1567-3 U in % of the ELV 131 mg/m³ 15.0 qal1.de info@qal1.de page 5 of 9

NDIR 011-10-18 Measured component SO Certification range 0-75 mg/m³ Sum of positive CS at zero point.85 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at reference point.80 mg/m³ Sum of negative CS at reference point -0.90 mg/m³ Maximum sum of cross sensitivities.85 mg/m³ Uncertainty of cross sensitivity 1.645 mg/m³ Standard deviation from paired measurements under field conditions * u D 0.416 mg/m³ 0.173 (mg/m³)² Lack of fit u lof 0.346 mg/m³ 0.10 (mg/m³)² Zero drift from field test u d,z -0.64 mg/m³ 0.389 (mg/m³)² Span drift from field test u d,s 0.784 mg/m³ 0.615 (mg/m³)² Influence of ambient temperature at span u t 0.755 mg/m³ 0.570 (mg/m³)² Influence of supply voltage u v 0.367 mg/m³ 0.135 (mg/m³)² Cross sensitivity (interference) u i 1.645 mg/m³.708 (mg/m³)² Influence of sample gas flow u p 0.045 mg/m³ 0.00 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.606 mg/m³ 0.368 (mg/m³)² Combined standard uncertainty (u C) u c.5 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 4.4 mg/m³ Relative total expanded uncertainty U in % of the ELV 50 mg/m³ 8.8 Requirement of 000/76/EC and 001/80/EC U in % of the ELV 50 mg/m³ 0.0 Requirement of EN 1567-3 U in % of the ELV 50 mg/m³ 15.0 qal1.de info@qal1.de page 6 of 9

NDIR 011-10-18 Measured component CO Certification range 0-50 mg/m³ Sum of positive CS at zero point 1.3 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at reference point 1.30 mg/m³ Sum of negative CS at reference point 0.00 mg/m³ Maximum sum of cross sensitivities 1.30 mg/m³ Uncertainty of cross sensitivity 0.751 mg/m³ Repeatability standard deviation at set point * u r 0.650 mg/m³ 0.43 (mg/m³)² Lack of fit u lof -0.173 mg/m³ 0.030 (mg/m³)² Zero drift from field test u d,z -0.17 mg/m³ 0.016 (mg/m³)² Span drift from field test u d,s 0.650 mg/m³ 0.43 (mg/m³)² Influence of ambient temperature at span u t 0.643 mg/m³ 0.413 (mg/m³)² Influence of supply voltage u v 0.163 mg/m³ 0.07 (mg/m³)² Cross sensitivity (interference) u i 0.751 mg/m³ 0.563 (mg/m³)² Influence of sample gas flow u p -0.018 mg/m³ 0.000 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.404 mg/m³ 0.163 (mg/m³)² Combined standard uncertainty (u C) u c 1.43 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96.81 mg/m³ Relative total expanded uncertainty U in % of the ELV 50 mg/m³ 5.6 Requirement of 000/76/EC and 001/80/EC U in % of the ELV 50 mg/m³ 10.0 Requirement of EN 1567-3 U in % of the ELV 50 mg/m³ 7.5 qal1.de info@qal1.de page 7 of 9

NDIR 011-10-18 Measured component CO Certification range 0-0 Vol.-% Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at reference point 0.00 Vol.-% Sum of negative CS at reference point -0.19 Vol.-% Maximum sum of cross sensitivities -0.19 Vol.-% Uncertainty of cross sensitivity -0.110 Vol.-% Standard deviation from paired measurements under field conditions * u D 0.094 Vol.-% 0.009 (Vol.-%)² Lack of fit u lof -0.115 Vol.-% 0.013 (Vol.-%)² Zero drift from field test u d,z -0.07 Vol.-% 0.005 (Vol.-%)² Span drift from field test u d,s 0.311 Vol.-% 0.097 (Vol.-%)² Influence of ambient temperature at span u t 0.100 Vol.-% 0.010 (Vol.-%)² Influence of supply voltage u v 0.067 Vol.-% 0.004 (Vol.-%)² Cross sensitivity (interference) u i -0.110 Vol.-% 0.01 (Vol.-%)² Influence of sample gas flow u p -0.005 Vol.-% 0.000 (Vol.-%)² Uncertainty of reference material at 70% of certification range u rm 0.16 Vol.-% 0.06 (Vol.-%)² Combined standard uncertainty (u C) u c 0.4 Vol.-% Total expanded uncertainty U = u c * k = u c * 1.96 0.8 Vol.-% Relative total expanded uncertainty U in % of the ELV 0 Vol.-% 4.1 Requirement of 000/76/EC and 001/80/EC U in % of the ELV 0 Vol.-% 10.0 Requirement of EN 1567-3 U in % of the ELV 0 Vol.-% 7.5 ** For this component no requirements in the EC-directives 001/80/EG und 000/76/EG are given. The chosen value is recommended by the certification body. qal1.de info@qal1.de page 8 of 9

Paramagnetism 011-10-18 Measured component O Certification range 0-5 Vol.-% Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at reference point 0.00 Vol.-% Sum of negative CS at reference point -0.19 Vol.-% Maximum sum of cross sensitivities -0.19 Vol.-% Uncertainty of cross sensitivity -0.110 Vol.-% Standard deviation from paired measurements under field conditions * u D 0.066 Vol.-% 0.004 (Vol.-%)² Lack of fit u lof 0.040 Vol.-% 0.00 (Vol.-%)² Zero drift from field test u d,z 0.098 Vol.-% 0.010 (Vol.-%)² Span drift from field test u d,s 0.081 Vol.-% 0.007 (Vol.-%)² Influence of ambient temperature at span u t 0.056 Vol.-% 0.003 (Vol.-%)² Influence of supply voltage u v 0.07 Vol.-% 0.001 (Vol.-%)² Cross sensitivity (interference) u i -0.110 Vol.-% 0.01 (Vol.-%)² Influence of sample gas flow u p 0.039 Vol.-% 0.00 (Vol.-%)² Uncertainty of reference material at 70% of certification range u rm 0.0 Vol.-% 0.041 (Vol.-%)² Combined standard uncertainty (u C ) u c 0.8 Vol.-% Total expanded uncertainty U = u c * k = u c * 1.96 0.56 Vol.-% Relative total expanded uncertainty U in % of the range 5 Vol.-%. Requirement of 000/76/EC and 001/80/EC U in % of the range 5 Vol.-% 10,0 Requirement of EN 1567-3 U in % of the range 5 Vol.-% 7,5 ** For this component no requirements in the EC-directives 001/80/EG und 000/76/EG are given. The chosen value is recommended by the certification body. qal1.de info@qal1.de page 9 of 9