Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Similar documents
Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Domestic Chill Tap

Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Zip Domestic ChillTap

Affix Model Number Label Here

Zip Chillmaster Floor Mounted Chiller

Zenith ChillTap Sparkling

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Zip Chilled Water Systems

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

HydroTap Taps Installation

Zip HydroTap Miniboil

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zenith HydroTap. CS Residential. Filtered Boiling, Chilled and Sparkling drinking water for Residential kitchens and tea rooms.

Model pictured: ST6001

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Installation & Operating Instructions

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Miniboil Boiling Only

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

INSTALLATION MANUAL CT-200

Model pictured: ST7001SLIM/ST7001SLIMA

DRINKING WATERCOOLER MANUAL. Website:

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Installation guide Sahara & Sahara Plus

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Model pictured: ST3701

Pear Kitchen Sink Tap

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

Model pictured: ST90001W/ST9001WA

SCHWAN INSTALLATION GUIDE

Target Monobloc Kitchen Mixer Chrome

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Blueberry Kitchen Sink Tap

Cinnamon Kitchen Sink Tap

HydroTap. Filtered boiling and chilled drinking water for residential use. Affix Model Number Label Here NZ. Installation Instructions

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

ZIP VARIPOINT II Direct unvented water heaters.

Monza Easyfit Kitchen Sink Mixer

Installation instructions. Zip HydroTap. Affix model number label here UK

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

Zip HydroTap G4 Celsius

RSA2CL6SS model pictured

Installation and Operating Instructions. ZIP UK Domestic - DOMBC2 - Filtered boiling and chilled drinking water for kitchens.

CHILLER DADDY MODEL: CHL-501 Intended Use For: Residential & Office Water Chiller

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Installation Instructions. Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms.

Installation & Operating Instructions

Beeline Monobloc Kitchen Mixer Tap

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

Instant Hot Water Dispenser Owner s Manual

HydroTap. User Guide. Tap Operation...(Pages 2-10) LCD Screen & Menu...(Pages 11-24) Maintenance... (Pages 24-26) Home Menu Icons...

Install Guide Billi Quadra & Quadra Plus (Gooseneck)

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Installation Instructions Zip HydroTap G4 BCS Residential Affix Model Number Label Here

Zen Boiling Tap Range

User Guide Reverse Osmosis Undersink Water Filter Systems RO SERIES

2-Stage Under Counter Filtration System Model: WP-2 LCV

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Owners Manual. 900 Series Drinking Water Appliance

User guide Billi Sahara & Sahara Plus Tap options XL, XT, XR

YEAR 2WARRANTY. Steamglide Iron RHC909 INSTRUCTIONS & WARRANTY RHC909_IB_100112

Installation instructions. Zip HydroTap. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Zip HydroTap. B & BA Residential. Affix Model Number Label Here Installation Instructions

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

STEAM WALLPAPER STRIPPER MODEL HTW5

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Work-Shed Vac 1100 Watt

Installation guide Billi Quadra & Quadra Plus XL, XT, XR tap options

INSTALLATION INSTRUCTIONS

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Karbon Kitchen Sink Tap

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

SCHWAN INSTALLATION GUIDE

Hot-1 Hot Water Dispenser

ZIP HydroTap G4 Celsius User Guide

OWNE R S MA N UA L. Made in USA. September 2015

aquamanta the experts in aquatic technology

1/7 SPOUT INSTALLATION

Whirly Cream Soft Serve Maker

ZIP HYDROCHILL High capacity chiller systems

RHK112_IB_FA_ Part No. T INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES

Autofill Wall Mount Boilers

Instruction Manual. Cheese Warmer with Pump

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

User guide Billi B-4000 Tap options XL, XT, XR

INSTALLATION GUIDE NZ AU D

Transcription:

Installation and Operating Instructions Zenith Chill Tap Extra Filtered Ambient and Chilled drinking water Affix Model Number Label Here 89520NZ Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00 Page 1 of 8

# Read Section These Heading Warnings First Please read all installation requirements, installation procedures and precautions before installing any Chill Tap. Never attempt to install any Chill Tap without reading all of the applicable instructions. All electrical connections must comply with current wiring rules. This appliance is not designed for use by young children or infirm people without supervision. Young children should be prevented from having access to ensure they are not able to use or play with the chiller. This appliance must be earthed. If the power supply cord is damaged it must be replaced by a Zenith Heaters Limited Service Provider or a qualified electrician. The Power cord and general power outlet must be in a safe and accessible position after installation. Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply. This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet. This unit is fitted with a chilled water expansion relief valve. It is normal operation to experience a small discharge from the carafe spout as the water will expand when the unit is chilling down. This is a protection device to prevent internal damage. Precautions The plumbing installation must be done in accordance with local Water Authority regulations and these Installation Instructions. As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and relevant standards. Page 2 of 8 Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00

# Installation Section Heading requirements Power supply 220-240V AC 50Hz for connection via a 10amp G.P.O. Operating temperatures 5º C - 35º C. Water pressure 70 kpa - 700 kpa (0.07 MPa -0.7 MPa) # Installation Instructions Installing the Chiller Sit the chiller unit into the cupboard as close to the proposed outlet tap position as is possible, to minimise the length of tubing exposed between the chiller unit and the outlet tap. Allow at least 50 mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must remain accessible for servicing purposes. Installing the Tap Position and install the carafe filler at the back of the sink or Font, where there is a minimum 52 mm wide flat area within the draining area of the sink. Make sure the selected position allows the carafe filler spout to overhang the sink bowl. Use a 35 mm sheet metal punch to create a neat hole without burrs. Remove the large nut with the brass and rubber washers from the base of the carafe filler, leaving the rubber-sealing ring (o-ring) in place. Fit the carafe filler and seal to the sink, oriented so both the operating levers are easily accessible. Slide first, the rubber washer and then the brass washer, followed by the nut, over the plastic tubes from under the sink, and tighten the nut to secure the carafe filler firmly into place. John Guest connections Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00 Page 3 of 8

# Installation Instructions continued Connecting: NOTE: You must separately supply and install an isolating valve in the supply line before the connection to the product. If the pressure exceeds 700kPa, you must also supply and install a 350kPa pressure-limiting valve. Minimum supply pressure must be 70kPa. Ambient Connection (with chiller inlet branch line): With 1/4 white tubing, Connect the outlet of the Pressure Reduction valve to the inlet of the filter. From the outlet of the filter, connect the 1/4 white tubing from the vented carafe filler, via the Tee piece supplied. The branch line from this Tee piece must connect to the JG fitting marked INLET on the top right rear of the chiller. Cut excess off to ensure a neat job. Make sure all connections to John Guest fittings are pushed in past the O ring to full depth, at least 15-16mm. Chiller connection (with expansion control valve): Similarly, use the Blue tube, to connect via a Tee piece, to the JG fitting marked OUTLET on the top left rear of the chiller unit. Insulate the 1/4 BLUE tube with the loose length of the pipe insulation, cut both pieces to correct length. Now connect the branch line from the (Blue tube) Tee piece, with a length of 1/4 Clear tube to the inlet of the relief valve. Locate the 1/4 Clear (vent) tube from the carafe filler and connect this to the outlet of the relief valve. Clear Blue NOTE: The inlet and outlet connections on the brass relief valve require the use of a small internal brass ferrule. This ferrule is used to stop the LLDPE tube from collapsing when the brass nut and olive are tightened. Flow White Clear Pressure reduction valve Isolation Valve NOT SUPPLIED Expansion control valve Filter Under Bench Chiller Page 4 of 8 Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00

# Installation Section Heading Instructions continued The Tap connection is now complete. Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing around a bend. As it is plastic tubing containing water under mains pressure, be careful not to nick, scratch or damage it during installation. Cut the tube squarely with a sharp knife or tube cutter. Shake out and remove any swarf and debris. Ensure there is adequate ventilation available through the cupboard. If there is inadequate ventilation, and the cupboard temperature rises to above 40 C, the chiller may become damaged and malfunction which will void the product warranty. The air temperature should be no more than 35 C. There must be a minimum 168cm2 of cupboard cross-flow ventilation. Suitable holes or vents will need to be cut into the cupboard and door. For safe operation, thoroughly flush the water through after non-use periods longer than 12 hours. Filter cartridges (if fitted) should be replaced at least every 6-12 months, or sooner if you notice: A. a persistent reduction in water pressure from the product, or; B. an unpleasant taste or odour in the water. Not changing the cartridges when required may cause the water to become biologically unsafe. Commissioning Clip the tubing in the cupboard. After the appliance is installed and connected, turn ON the water supply. Check all connections for leaks. Repair any leaks found. The filter, chiller and tubing will be full of air until purged. Press the operating lever on the appliance outlet tap for a minimum of five minutes until all of the air has been purged from the system. Plug the 3-pin power cord into a standard power point. Do NOT turn ON until after the unit is purged. Wipe clean and dry the area. Dispose of packaging wisely. End of life disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details. Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00 Page 5 of 8

# Operating Procedures # ROTATE Operation: The lever on the right is used for Chilled filtered water and the other, on the left, is used for Ambient filtered water. Chilled water is obtained by rotating the lever on the right, to a horizontal position. The water is chilled by a refrigeration unit fitted within the cabinet stand, under the basin. With the carafe filler, you can obtain chilled water within the rated capacity, for as long as you leave the lever in the open (horizontal) position. When finished, return the lever to the OFF (upright) position. Ambient water is obtained in the same way as the chilled water, by rotating the lever on the left hand side of the carafe. Cleaning Never use strong, corrosive or abrasive cleaning materials on the Zenith Chill Tap. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water. The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents. They should be checked regularly, at least monthly, and dusted or vacuumed. Filter Replacement The Zenith Chill Tap Under Counter Chiller may have a separate filtration system connected to the incoming water supply line, and which may be located within the same cupoard as the chiller unit. For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water. WARNING Not changing filtration cartridges when required, may cause the water to become biologically unsafe. Make an entry in your diary to check the water quality of the Chill Tap at least six months after installation and after every subsequent filter change. Use only a Zenith Filter to match that used with this Chill Tap (if fitted). Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zenith Heaters Limited. Replacement instructions come with the filter cartridges. Before attempting to disconnect or remove the filter cartridge from the housing, isolate (turn off) the water supply prior to the filter system, and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow. Service There are no user serviceable parts but there are dangerous voltages present within the unit. All service work must only be carried out by a suitably qualified and experienced service person. Before calling for service, check that both the water and electricity supplies are turned ON and OK. Call an electrican, a plumber or Zenith Heaters Limited, for assistance, service, spare parts, or enquiries. Page 6 of 8 Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00

# Warranty Section Heading Information Certain warranties may be implied by law into your contract with Zenith Heaters Limited. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law. Zenith Heaters Limited warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by Zenith Heaters Limited or its distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Zenith Heaters Limited. Zenith Heaters Limited shall be the sole arbiter of whether there is a part failure intended to be covered by this warranty. No costs are payable by you other than any mileage or travelling-time charges incurred by a Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair to it s Distributor. This warranty does not cover damage resulting from non-operation of the appliance, the use of non authorised parts or consequential damage to any other goods, furnishings or property. Zenith Heaters Limited does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zenith Heaters Limited under the laws applicable. Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zenith Heaters Limited is entitled to do so, the liability of Zenith Heaters Limited under any statutory warranty will be limited at Zenith Heaters Limited option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance. Registering your product: Registering your installation on the Zenith Heaters Limited website may help to establish date of installation, should it become necessary to service the appliance, under the terms of Zenith Heaters Limited warranty. To register your installation go to www.zenithheaters.co.nz and look under the heading Warranty. As Zenith Heaters Limited policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. Full warranty details may be found on the website Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00 Page 7 of 8

Contact Details Head Office Zenith Heaters Limited, IRD No. 95 640 729 Unit 2/15 Moselle Avenue, Henderson. Auckland. 0610 New Zealand. WMKA21821 ATS 5200.105 www.zenithheaters.co.nz Telephone: 0800 558055 Facsimile: 0800 559055 Chilltap - Installation & Operating Instructions - 89520NZ - June 2012 v1.00 Page 8 of 8