Installer & User Guide Effective January 2017

Similar documents
Installer & User Guide Effective February 2013

PS12 12 day Autotimer water softener

Effective April 14. Installation Date:..

Installer & User Guide Effective January 2013

MONARCH WATER INSTALLER & USER GUIDE. Effective January The Plumbsoft Water Softeners with the 7 & 2 year Guarantee

With CRYSTALGUARD. post filter technology

MONARCH SCALEOUT MONARCH WATER

Watch Water USA Green Chemical Technology

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Installation Instructions Flute Tap Range

Installation, Operation and Maintenance Manual. Model: SSC ScaleSolver Systems. Chemical Free, Salt Free, Scale Prevention

Thermostatic bar mixer valve with adjustable head Installation guide

~-ti-=t"- MODELS. !'..,.~-_ ~ _,, -:~.. l- l.. -l > _ {.- ~ t "',, j ~ t. t- -,l-~ -+ _ "'l.,.._

Owners Guide ScaleSolver Residential System

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

The Professional s Choice

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

NOT EVERYTHING IN LIFE IS COMPLICATED.

X62 Tap Range. Please keep these instructions for future reference

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

Installation, Operation and Maintenance Manual

Thermostatic exposed shower valve and bath/shower mixer systems Installation guide

Inta City Concealed Shower Mixing Valve CT80010CP

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Scale Stopper Plus Installation & Start-Up Guide

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Intatherm Safe Touch Basin Tap IT1008CP

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

These instructions must be left with the user.

Mira Reflex Thermostatic Bar Valve

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

What to expect from your water softener

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

The Classeq under counter range

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Installation Instructions and User Guide. Heritage Fixed Riser Kit. Models Covered: STC03 (Chrome) STA03 (Gold)

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Empura Water Filter. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Water Softener. Operating Manual

Telo Shower Mixing Valve TL10016CP

Residential Application

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Blitz Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Enzo Concealed Shower Mixing Valve

Inta City Shower Mixing Valve CT20010CP

SEALED THERMAL STORE

Tier1 Water Home Filtration System

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Plus Bath Shower Mixing Valve CP and PL30020CP

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Artisan Thermostatic Bath Filler

Thermostatic Shower Tower Installation and Operating Instructions

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

To us it, s more than just water. Made right here for Australian conditions. water softeners

Deluge Shower Mixing Valve 10045CP

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

ACN Home Security in collaboration with Verisure UK. Market & Product Overview

The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Please take time to carefully read through these guidelines before using your Kamco pump.

Dene Bath Shower Mixer

Thermostatic Bar Valve

MIDAS. Installation instructions 110/220

Mio Concealed Shower Mixing Valve MI40010CP

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Installation & Operators Manual

The Professional s Choice

Mira Atom ERD Thermostatic Bar Valve

Installation, Commissioning, Programming & User Information For Water Softener Models: SF 10 Litre Timed & SF 12 Litre Metered

Puro Mini Dual Control Shower Mixer PU90010CP

Installation Instructions and User Guide

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1

Installation, Operating and Maintenance Guide

installation INSTRUCTIONS

Kiko Bath Shower Mixing Valve KK90015CP

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

Please take time to carefully read through these guidelines before using your Kamco pump.

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Bath Shower Mixer

Installation, Operation & Maintenance Instructions

Deluge Concealed Shower Mixing Valve DL40010CP

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Please take time to carefully read through these guidelines before using your Kamco pump.

Shower Tower manual mixer

Water Softener Installation Guide Effective for all Softeners from our Range

WC2 & WC3 Installation & Maintenance Instructions

Thames thermostatic bar mixer with diverter Installation and operating instructions

Ambassador. Installation guide & user instructions. Please ensure that this document is handed to the user after installation is completed

Installation Instructions and User Guide

Transcription:

Model No. MONARCH WATER Installer & User Guide Effective January 2017 For Monarch Scaleout Suppliers to H.M. the Queens Estate at Sandringham Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP T 01986 784759 F 01986 784769 info@monarchwater.co.uk www.monarchwater.co.uk

HINTS AND TIPS ABOUT YOUR NEW SCALEOUT 1 The Scaleout converts both cations and anions into harmless crystals. Crystals will adhere themselves to the Post Filters internal cartridge, which is to be changed annually (or before in very hard water areas). However some will pass through as this is part of the descaling process. These will materialise as a residue/dust if the water is allowed to evaporate. For best results it is recommended to wipe away with a damp cloth before they appear. 2 Helping your kettle last longer: Your kettle will continue to have an amount of scale, but the level can be kept to a minimum by running the tap for 5-10 seconds prior to filling. Additionally, it is recommended to empty the kettle of any water left over from the previous use. When emptying, you may notice scale flakes and possibly milky water too. This is normal and proof that the Scaleout is working at optimum performance. Flakes are caused by taking the water to boiling point and will not happen elsewhere throughout your system. 3 Toilets, Showers, Shower cubicle/screen, Taps etc: Because there is no direct flow across these surfaces, other than water splashing, the old scale may need to be removed with a scale remover. Any new accumulation will deposit as a soft scale and can be removed. For best results, wipe away water before being allowed to evaporate. 4 Existing scale Scaleout water will immediately begin to de-scale your pipes and appliances. Your hot water cylinder will take longer to de-scale than your pipe work; in some cases 12-18 months; therefore you may notice different levels of Scaleout water for some time whilst the system is de-scaling. This is particularly noticeable in your bath and shower. 5 Dishwashers On most installations the dishwasher is to be connected to the Scaleout water. We recommend that you continue to add a small amount of salt to the appliance as before, as this helps the salt holder in the appliance stay clean. We do not however recommend that crystal glass; solid silver or silver plated items are washed in your dishwasher as etching may occur. Less dishwasher liquid may be required and in certain cases this will also apply to rinse aid. For best results use a natural soap detergent/ cleaning agent. On dishwashers connected to untreated water, you should continue to put salt into the dishwashers own softener. It will help if your dishwasher could be de-scaled prior to the installation of the Scaleout. This would also apply to your shower cubicle too. For best results use a phosphate free dish washing detergent. 6 Scaleout water will become available throughout your system in varying time spans. Conventional systems (tanks in your roof) will take anything from 4-10 days, whilst mains fed Pressurised Systems will give treated water within 2-3 days. 7 Scaleout water will have no adverse effect in your heating system. In every case a corrosion inhibitor such as Sentinel X100 must be used. 8 Bath and shower surfaces will become smoother be careful, in particular the young and infirm why not buy a bath mat? 9 If possible look to use a pure soap powder as this will help give optimum results. 10 Outside Tap It is recommended to leave your outside tap on mains water. Additionally, in the wintertime we recommend that this tap is isolated via an internal valve to prevent freezing. 11 Accumulators Please ensure that a Scaleout is installed on the outlet to an accumulator. 2

MONARCH SCALEOUT INSTALLATION INSTRUCTIONS Thank you for choosing our SCALEOUT XP. Please read the following carefully, which if followed correctly, should ensure the installation is trouble free. Before you install the unit, please ensure you have the correct model with regard to demand placed upon unit and also the water hardness. Ensure + models are used on all water hardness over 500ppm. Monarch has a nationwide database on all water hardness s for your assistance A. PLANNING THE INSTALLATION Always observe the water byelaws. Ensure there is only one rising main. Make sure you have allowed space for access to the unit for any possible maintenance in the future. Check the water pressure and locate the rising main. Be aware of condensation occurring in warm environments. If condensation occurs, we recommend the unit is sited in a small tray that allows the water to evaporate. Unit must be kept upright. B. SITING THE SCALEOUT Where possible, this should be close to the rising main. T off for an untreated mains supply for the outside tap. Ensure that the unit is not subject to below 4 or above 50ºC. If siting the unit within a kitchen cupboard, loft etc. Ensure that the base/ floor is adequately supported. If the unit is being installed in your loft, 1st, 2nd floor etc., it is recommended to house the unit within a plastic tank and insulate well. The overflow on the plastic tank should be a minimum of ¾ in size. Failure to install the unit in a suitable tank will void the Guarantee. C. NON-RETURN VALVE In domestic applications i.e. house, bungalow, apartment, flat etc, a single check valve should be fitted. All other applications require a double check valve. D. DRINKING WATER FACILITY The unit produces drinking water, so unlike a salt based softener, no dedicated tap is required. E. MATERIAL CHECK LIST The unit includes an installation kit as relevant to the model ordered. 3

F. WATER PRESSURE TEST It is IMPORTANT that a pressure check is carried out. Low and high pressure can result in either damage to, or failure of the unit. If daytime static water pressure* exceeds 3.5 bar (50psi) a 5 bar pressure limiter should be fitted. *50psi daytime pressure can reach nearly 100psi at night! Minimum dynamic pressure must exceed 1.5 bar. If in any doubt please call us on 01986 784 759 G. INSTALL BYPASS VALVES & NON-RETURN VALVE Form an installation as per Fig 1 Below. Scaleout water to service Checklist Water pressure 1.5 5 bar (20 70psi) Access for maintenance Bypass Valve (shut) Outlet Valve (open) Non-Return Valve Supply to outside tap Inlet Valve (open) Pressure Limiting Valve (if required) FIG 1 STOP TAP ON INCOMING MAIN H. INLET & OUTLET CONNECTIONS See Fig 1 Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe. Ensure nipples (when used) have been tightened to seal. 4

Connect the inlet hose from the INLET valve/male iron adapter on the pipe work to the INLET of the Scaleout - see directional arrow on top of unit. Connect the outlet hose from the OUTLET valve/male iron adaptor on the pipe work to the OUTLET of the Post Filter. PLEASE NOTE The unit is supplied with nipple connections for both inlet and outlets on the connection head. Insert 1" fibre washers into the heads up against the shoulder at the end of the female thread. Insert nipples up against fibre washers and tighten against shoulder to seal. I. TEST INSTALLATION FOR LEAKS Close Inlet and Outlet valves to the unit and open Bypass valve. Open mains stopcock and flush the new pipe work for a minimum of 5 minutes. This can be done using any mains water tap inside the property i.e. utility room, kitchen cold tap or wash hand basin in a bathroom. Close Bypass valve, then open Inlet and Outlet valves slowly. Allow water to run slowly until all air is purged from the unit, then close tap. Allow unit to rest for 15 minutes before future use. Check for leaks. GOING ON HOLIDAY? Fig 2 shows the valves in the Service position (Bypass is closed and Inlet & Outlet are open). We highly recommend you bypass your unit when going away on holiday. Simply turn Inlet, Outlet and Bypass valves ¼ turn to put valves into Bypass positions. Upon your return, move valves back to the Service position (as Fig 2 right). Bypass Valve (shut) to service Outlet Valve (open) MAINTENANCE a. Change resin every 3 years or before if water quality decreases. b. Change post filter every 12 months or before if water quality decreases. Post Filter models SXP15 & SXP22: SXPF5 SXP28 & SXPLC: SXPF10 Non-Return Valve Supply to outside tap Inlet Valve (open) Pressure Limiting Valve (if required) STOP TAP ON INCOMING MAIN 5 FIG 2

Installation Conditions Effective February 2013 The Monarch Scaleout is fully covered by a retrospective 3 year parts and 12 months labour guarantee for installation within the hard water regions of mainland England as detailed on Monarchs National Service Coverage Area, from date of original purchase. Installations outside this area are automatically covered by a 3 year parts only exchange warranty. Definition and example of Retrospective: If the resin fails at 30 months, then new resin will be replaced under the 3 year guarantee but charged at 30/36ths of the replacement resin cost, plus delivery, plus VAT. PLEASE NOTE This guarantee has the following conditions, and is not covered by the following. 1. Damage caused by high water pressure, we strongly recommend a 5 bar water pressure limiting valve on the inlet to your water supply, where daytime water pressure exceeds a static pressure of 3.5 bar (50psi). 2. This Scaleout is suitable for a mains water supply only. 3. Damage caused by a dirty mains water supply. The installation of a Monarch Debris Filter - cost 99.60 inc VAT & postage - on the supply to your unit cancels this clause. The majority of debris in water is caused by local authority work on the water main. If notified in advance, by your local water authority, please put your unit onto bypass, see Fig 5. For Bypass: Close both Inlet & Outlet valves, and open Bypass valve. For Normal Service: Open both Inlet & Outlet valves, and close the Bypass valve. 4. Call outs due to incorrect installation. If you have any queries when installing your Scaleout, please call us on 01986 784759. 5. The use of any other hoses than those provided. Under no circumstances use washing machine hoses. 6. The effect of aggressive water, the degradation and/or blinding of resin and/or chlorine attack on resin. 7. Under no circumstances plumb in the unit in solid copper. 8. The installation kit is only covered by the OEM twelve-month parts exchange warranty only. 9. Compensation as a result of cancelled appointments, damage caused by, or incorrect installation of the unit. In the unlikely event of a fault, put the unit onto Bypass, see 3 above ref For Bypass until an engineer calls. THE ABOVE DOES NOT AFFECT YOUR STATUTORY RIGHTS Incoming Water Conditions Min Max Operating pressure 1.5 5 bar Temperature 3 35ºC ph 6.5 8.5 Max Iron content Max Manganese content Max Copper content Oil & Phosphates H2S 0.3 mg/l 0/05 mg/l 0.3 mg/l Free Free 6 IMPORTANT The XP unit must not be installed where ambient temperature can exceed 35ºC or where there is a possibility of HOT WATER transfer back through the system into the unit. CAUTION should be exercised where there is a possibility of secondary water expansion from the heating boiler back through the system into the unit. In such circumstances, you are advised to fit a single check valve between the unit and the boiler.

Monarch National Service Coverage Areas - Effective February 2012. The below Postcodes (see map below) are automatically covered by a 3 year parts and 12 month labour warranty. B BA BH BN BS CB CM CO CT CV DT GU GL HP IP LE LONDON inset LU LN ME MK NG NN NR OX PE PO RG RH SG SL SN SO SP SS TN IMPORTANT Scaleouts sold outside the above Postcodes are to be covered strictly by a parts only exchange warranty. All parts sent back to Monarch are at the expense of the sending parties. All repaired or replaced items will be returned to the sender on a no charge basis whilst covered by the parts exchange guarantee. Once the parts exchange guarantee has expired, Monarch reserves the right to make a charge for any postage/delivery, labour and parts charges that is deemed necessary. Monarch will endeavour to keep these charges at the lowest cost whenever possible. 7

SCALEOUT INSTALLATION RECORD Original Installation Date 1st Resin Change Date 2nd Resin Change Date 3rd Resin Change Date 4th Resin Change Date POST FILTER INSTALLATION RECORD Original Installation Date 1st Cartridge Change Date 2nd Cartridge Change Date 3rd Cartridge Change Date 4th Cartridge Change Date 5th Cartridge Change Date 6th Cartridge Change Date 7th Cartridge Change Date 8th Cartridge Change Date 9th Cartridge Change Date 10th Cartridge Change Date 11th Cartridge Change Date 12th Cartridge Change Date 13th Cartridge Change Date 14th Cartridge Change Date 15th Cartridge Change Date 8