Kata products Kata DGM-1500 Turva

Similar documents
RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Nuclear Associates

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Identify the following features and specifications for the ESP1

Dosimeters/Survey meters

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

RAM GENE / RAM GENE-1

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

DMC 2000 Personal Electronic Dosimeter

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

Electronic Personal Dosemeter

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Radioactivity dosimeter RD01. User's Manual

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Radiation Alert Frisker INTERNATIONAL

Using the GammaRAE II Personal Radiation Detector

Contamination Meter Users Manual

Danfoss gas detection units

Setting the new standard for personal radiation detection.

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Ranger EXP RADIATION A L E R T

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

DIGITAL AREA RADIATION MONITOR

Portable Survey Instruments NISP-RP-01

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Area Monitor/Frisker Count Rate Meter Victoreen

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Our Extended Personal Electronic Dosimeter (PED) Family

DMC 3000 Quick User s Guide

Scientific Production Company Doza. Radiation monitoring equipment

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

MODEL 951 RADIATION DETECTOR

stationary dose rate measuring systems

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

Surface Contamination Monitor. Operation Manual

ß-Aerosolmonitor FHT 59 C

PRD Domestic Price List

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

EcotestVIP PERSONAL RADIOACTIVITY DETECTOR. Operating manual ВIСТ РЭ

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

DMC 3000 User s Guide

Recalibrate the way you look at gas detection

Dual-Diode Dosimeter Patient Dose Monitor

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Seismic Countermeasures for Environmental Radiation Monitoring System

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

PURPOSE AND SPECIFICATIONS

AERIAL RADIATION DETECTORS

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

910A DOSIMETER CHARGER, AC-POWERED

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

RIID capability in the palm of your hand

Radiation Monitoring Equipment

LUDLUM MODEL 44-3 LOW ENERGY GAMMA SCINTILLATOR. May 2018 Serial Number PR and Succeeding Serial Numbers

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

X-ray Inspection System Discover What You've Been Missing... DETECTION PERFECTION

LAUNDRY MONITORING SYSTEM Model # LIM-64S

Radiation Monitoring Systems

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Environmental Radiation Monitoring System

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

IRT2 Dual Laser IR Thermometer - User Guide

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

PRELIMIN INTERNATIONAL

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

requirements. Serial: USB or RSXXX Bluetooth GPS/GSM Ethernet Standard or rugged desktop or laptop PC or tablet; Android smartphone or tablet

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Danfoss gas detection units

P U B L I C N O T I C E

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

Radiation Safety for AREAL Phase 1

RAM GAM-1C Gamma Survey Meter TYPE TEST

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

Advanced Radiation Detection Equipment

Danfoss gas detection unit Type GD Heavy Duty

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

Transcription:

Kata DGM-1500 Turva RADIATION DETECTED: Gamma and X-ray MEASUREMENT UNITS: microsv/h (μsv/h) LINEAR RANGE: Dose rate 0.01-100 000 microsv/h Dose 0.001-1000 millisv SENSITIVITY: 150 cpm/microsv/h ACCURACY: ± 5 % of the reading when irradiated by Cs-137 at the calibration point at 20 deg. C. LINEARITY: ± 10 % at 20 C RESPONSE TIMES: Fast measurement mode 2.5 sec. Automatic measurement mode 3 min. at ambient radiation levels, at increased radiation levels (> 100 microsv/h) 5 sec. Accuracy measurement mode, at low level radiation, integration time long to 3 hours as far as, used in gamma radiation measuring of foodstuff, for example. DETECTOR TYPE: Ambient dose equivalent Hp(10) -energy compensated GM-tube, quenching type Neon/Halogen ENERGY DEPENDENCE: ± 30 %, 45 kev - 1.25 Mev PHYSICAL CHARACTERISTICS: Display type 4 -digit LCD-display 44 x 18 mm. Big dose rate showed like this 30E3 (30 000 microsv/h) OPERATING TEMPERATURE RANGE: -30 C to +55 C OVERALL DIMENSIONS: L x W x H1/H2, 14.7cm x 9.1cm x 5.2/3.2cm WEIGHT: 300 g with battery AUDIO SPEAKER: Piezoelectric speaker ALARMS: Adjustable dose rate and dose alarm level BATTERY: (1) 6LR61, 9 V battery, battery life 300 h (background level), low-battery indication CASE: Shock-proof, splash-proof plastic case IP-54 MAIN ADAPTER: 9 VDC reg. / 2.5 W (3,5 mm plug) diode protected against wrong polarity Standard configuration incl. battery, calibration certification and user manual. SPECIAL FEATURES: Cesium-137 measurement of foodstuff Accuracy ± 200 Bq/l Automatic calculation of Radon-Box 10 (R-10) or automatic calculation with foodstuff measurement of Cesium-137(Cs). HAVE TO DEFINE ON REQUEST!

Kata DGM-1500 Turva vaterproof RADIATION DETECTED: Gamma and X-ray MEASUREMENT UNITS: microsv/h (μsv/h) LINEAR RANGE: Dose rate 0.01-100 000 microsv/h Dose 0.001-1000 millisv SENSITIVITY: 150 cpm/microsv/h ACCURACY: ± 5 % of the reading when irradiated by Cs-137 at the calibration point at 20 deg. C. LINEARITY: ± 10 % at 20 C RESPONSE TIMES: Fast measurement mode 2.5 sec. Automatic measurement mode 3 min. at ambient radiation levels, at increased radiation levels (> 100 microsv/h) 5 sec. Accuracy measurement mode, at low level radiation, integration time long to 3 hours as far as, used in gamma radiation measuring of foodstuff, for example. DETECTOR TYPE: Ambient dose equivalent Hp(10) -energy compensated GM-tube, quenching type Neon/Halogen ENERGY DEPENDENCE: ± 30 %, 45 kev - 1.25 Mev PHYSICAL CHARACTERISTICS: Display type 4 -digit LCD-display 44 x 18 mm. Big dose rate showed like this 30E3 (30 000 microsv/h) OPERATING TEMPERATURE RANGE: -30 C to +55 C OVERALL DIMENSIONS: L x W x H1/H2, 14.7cm x 9.1cm x 5.2/3.2cm WEIGHT: 300 g with battery AUDIO SPEAKER: Piezoelectric speaker ALARMS: Adjustable dose rate and dose alarm level BATTERY: (1) 6LR61, 9 V battery, battery life 300 h (background level), low-battery indication MAIN ADAPTER: 9 VDC reg. / 2.5 W (3,5 mm plug) diode protected against wrong polarity CASE: Shock-proof, waterproof plastic case IP-67 Standard configuration incl. battery, calibration certification and user manual. SPECIAL FEATURES: Cesium-137 measurement of foodstuff Accuracy ± 200 Bq/l Automatic calculation of Radon-Box 10 (R-10) or automatic calculation with foodstuff measurement of Cesium-137(Cs). HAVE TO DEFINE ON REQUEST!

Radon-Box 10 Kata products 2013 KATA - MEASUREMENT OF RADON 1 PREPARATIONS BEFORE THE MEASUREMENT PROCESS Prior the beginning of every measurement Radon-Box 10 unit must be cleaned. Purpose of this cleaning process is the disposal of absorbed radon gas and moisture inside the unit. Cleaning is performed by keeping the Radon-Box 10 unit at ~105 C temperature (e.g. in electric oven) for 12 hours. After the heating process and after the unit has cooled down it must be put into airtight plastic bag. By keeping the unit at airtight environment ensures that the unit will not absorb radon gas from air before the actual measurement process. 2 MEASUREMENT PROCESS Remove the Radon-Box 10 unit from the plastic bag and place it to the location from where the radon concentration should be determined. Ambient temperature should be 18 25 C and relative humidity less than 80% through the measurement process. After seven (7) days put the unit into airtight plastic bag and close it carefully. The unit is now ready to be analyzed using the DGM- 1500 Turva survey meter. Analyzing phase should be started within three hours after the Radon-Box 10 unit has been closed inside the plastic bag. 3 DEFINING THE RADON CONCENTRATION 3.1 SELECTING THE PLACE Choose an applicable analyzing place (e.g. desktop) and make sure there are no stone walls near that spot.

3.2 MEASURE THE AMBIENT BACKGROUND RADIATION LEVEL 1) Take the DGM-1500 Turva survey meter and turn it on. 2) Change the measurement mode to accuracy measurement by pressing the zero (0) button until h-letter (lowercase) is shown on the display. After an every hour the letter h on the display of DGM-1500 Turva will change its case to indicate that an hour has elapsed (1 st hour h, 2 nd hour H, 3 rd hour h etc). 3) Place the DGM-1500 Turva survey meter at the place you chose and make sure the Radon-Box 10 unit is not close to DGM-1500 Turva at this time. 4) Wait at least two hours (recommendation is three hours) until the DGM-1500 Turva has accurately measured the ambient background radiation level. 3.3 ANALYZE THE CONTENT OF RADON-BOX 10 1) Take the Radon-Box 10 unit out from the plastic bag and place it to exact location where the background radiation level was measured. 2) Take the DGM-1500 Turva and change the measurement mode to radon measurement by pressing the zero (0) button until the text r-10 is shown on the display. NOTICE! Make sure you don t press the zero (0) button down too long so that the mode goes past the radon measurement mode ( r-10 on display). Otherwise you have to repeat the ambient background radiation level measurement again. 3) While the r-10 reading on the display of DGM-1500 Turva slide it inside the Radon-Box 10 unit from the hole at the right side. 4) After three hours the reading on the display of DGM-1500 Turva will indicate the radon gas level at the air (Bq/m3) from the place where the actual seven day measurement was performed.

Kata DGM-1500 Turva Ethernet RADIATION DETECTED: Gamma and X-ray MEASUREMENT UNITS: microsv/h (μsv/h) LINEAR RANGE: Dose rate 0.01-100 000 microsv/h Dose 0.001-1000 millisv SENSITIVITY: 150 cpm/microsv/h ACCURACY: ± 5 % of the reading when irradiated by Cs-137 at the calibration point at 20 deg. C. LINEARITY: ± 10 % at 20 C RESPONSE TIMES: Fast measurement mode 2.5 sec. Automatic measurement mode 3 min. at ambient radiation levels, at increased radiation levels (> 100 microsv/h) 5 sec. Accuracy measurement mode, at low level radiation, integration time long to 3 hours as far as, used in gamma radiation measuring of foodstuff, for example. DETECTOR TYPE: Ambient dose equivalent Hp(10) -energy compensated GM-tube, quenching type Neon/Halogen ENERGY DEPENDENCE: ± 30 %, 45 kev - 1.25 Mev PHYSICAL CHARACTERISTICS: Display type 4 -digit LCD-display 44 x 18 mm. Big dose rate showed like this 30E3 (30 000 microsv/h) OPERATING TEMPERATURE RANGE: -30 C to +55 C OVERALL DIMENSIONS: L x W x H1/H2, 14.7cm x 9.1cm x 5.2/3.2cm WEIGHT: 300 g with battery AUDIO SPEAKER: Piezoelectric speaker Kata DGM Monitor ALARMS: Adjustable dose rate and dose alarm level BATTERY: (1) 6LR61, 9 V battery, battery life 300 h (background level), low-battery indication MAIN ADAPTER: 9 VDC reg. / 5.0 W (3,5 mm plug) diode protected against wrong polarity ETHERNET: Ethernet functionality only works when the meter is used with mains adapter. This is of higher power consumption. When operated with battery power the meter works as normal handheld meter without the Ethernet functionality Standard configuration incl. battery, main adapter, Ethernet cable, Kata DGM Monitor program, calibration certification and user manual.

Kata DGM-1500 Turva Strontium meter RADIATION DETECTED: Beta and Gamma MEASUREMENT UNITS: microsv/h (μsv/h); Becquerel/litre (Bq/l) for Foodstuff measuring. LINEAR RANGE: Dose rate 0.01-100 000 microsv/h Dose 0.001-1000 millisv ACCURACY: ± 5 % of the reading when irradiation by Cs-137 and Sr-90 at the calibration point at 20 deg. C. (Calibrated 100 % for foodstuff measuring of Sr-90, accuracy ± 200 Bq/l. Response to foodstuff measuring of Cs-137 is very slow.) LINEARITY: ± 10 % at 20 C RESPONSE TIMES: Fast measurement mode 2,5 sec. Automatic measurement mode 3 min. at ambient radiation levels, at increased radiation levels (> 100 microsv/h) 5 sec. Accuracy measurement mode at low level radiation, integration time long to 3 hours as far as, used in Strontium-90 radiation measuring of foodstuff, for example. DETECTOR TYPE: GM-Tube, not energy compensated. ENERGY DEPENDENCE: Dependence of the energy. Not suitable for X-ray measuring. PHYSICAL CHARACTERISTICS: Display type 4 -digit LCD-display 44 x 18 mm. Big dose rate showed like this 30E3 (30 000 microsv/h) OPERATING TEMPERATURE RANGE: -30 C to +55 C OVERALL DIMENSIONS: L x W x H1/H2, 14.7cm x 9.1cm x 5.2/3.2cm WEIGHT: 300 g with battery AUDIO SPEAKER: Piezoelectric speaker ALARMS: Adjustable dose rate and dose alarm level BATTERY COMPLEMENT: (1) 9 V battery, battery life 300 h (background level), low-battery indication MAIN ADAPTER: 9 VDC reg. / 2.5 W (3,5 mm plug) diode protected against wrong polarity Standard configuration incl. battery, calibration certification and user manual. Automatic calculation with Sr-90 measurement of foodstuff (Sr). Strontium-90 measurement of foodstuff Accuracy ± 200 Bq/l