1. Package content. User Manual v1.3

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

EWR2 WIRELESS SIGNAL REPEATER

EWF1 EWF1CO WIRELESS SMOKE DETECTOR WIRELESS SMOKE & CO DETECTOR

EP364 USER MANUAL ALARM AND MANAGEMENT SYSTEM

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

COMMUNICATOR ET08 / ET081

EWF1 WIRELESS SMOKE DETECTOR

User s Information Guide R2A

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

PITBULL ALARM. GSM Alarm System

External Wireless Sounder

Watchguard WGAP864 User Manual

Contents. Glossary

Independent Zone Control (I.Z.C.)

1126 Series Ceiling Mount PIR Motion Detector

System. For a better understanding of this product, please read this user manual thoroughly before using it.

External Wireless Sounder

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Condominium Security Management System

IDS816 User Manual H Issued January 2009

Installation and Operation Guide EXTERNAL SIREN

Wireless Keypad GKP-S8M

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

GSM RFID VOICE Alarm System

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

MOBILE CALL GSM Alarm System User s Manual

GSM ALARM AND MANAGEMENT SYSTEM ESIM264 COMPLIES WITH EN GRADE 2, CLASS II REQUIREMENTS

JA-63 Profi User manual

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

3 User s settings. 3.3 Internal clock setting

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

CHEAT SHEET: SPECTRA V2.1

Solution Ultima 862 Operators Manual ISSUE 1.10

USER MANUAL Mobeye ThermoGuard CM2200

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Version 1.03 January-2002 USER S MANUAL

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Quick Reference Guide

X64 Wireless Training

Installation Manual Premier 412/816/832. Issue 10

Smart Home Outdoor Siren

QUICK USER GUIDE. Alarm Control Panel

Ion Gateway Cellular Gateway and Wireless Sensors

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

System Introduction. 1.1 Specifications

Intelligent Wireless GSM Alarm System

All-In-One Wireless Security System V1.0. Model #: MG-6060

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Door/Window Sensor. Set-Up Guide

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Wireless Keypads LKP(E)S8M Series

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

PERMACONN PM1030 Includes DI300. Installation Manual

EVO192 v3.0 Fire and Burglary What s New

ALSET-2000 WIRELESS SECURITY SYSTEM

INSTALLATION GUIDE XTLN-WIFI PANEL

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Training Manual Multi-Language with Wireless

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

TABLE OF CONTENTS TABLE OF CONTENTS 1

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

My Visonic SMS App User Guide

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Tomorrow s technology for today s security needs.

GLOBAL. InstallatIon & operation manual

PROGRAMMING PROCEDURES (Table 3)

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

ET083 2G/3G COMMUNICATOR

Alarm System SECURE AS 302

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Wireless External Alarm

ET082 GSM/GPRS COMMUNICATOR

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

Advisor Advanced User Guide

XTLC PANEL INSTALLATION GUIDE

Training Manual with Bi-directional Wireless

System Introduction. 1.1 Specifications S E C T I O N 1

Solution Ultima Series Operators Manual ISSUE 1.00

HILLS Series LED Code Pad User Manual

Paradox Integration Module Settings Guide

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

1125 PIR Motion Detector

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

READY TO ARM 1st Floor 2nd Floor

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

Transcription:

EKB3W WIRELESS LED KEYPAD

User manual v1.6 Compatible with: ESIM364 all versions. EPIR v05.06.02 and up + EWT2 v16.17 and up. EPIR2 all versions. EPIR3 all versions. Main features: Alarm system arming and disarming. Arming and disarming in Stay mode. System parameter configuration. PGM output control. Visual indication by LED indicators. Audio indication by built-in buzzer. Keypad partition switch. EKB3W is a wireless LED keypad intended to use with ELDES alarm systems. The system configuration by EKB3W keypad is performed by activating the Configuration Mode and entering the required parameters and values. It is possible to connect up to 4 EKB3W devices to ELDES alarm system at a time. The maximum wireless connection range is 150m (492.13ft) (in open areas). NOTE: For complete information on device operation with ELDES alarm system, please refer to ELDES alarm system installation manual located at www.eldes.lt/download 1. CONTENT OF PACK Item Quantity 1. EKB3W... 1 2. User manual... 1 3. 5,6kΩ resistor... 1 4. Screws... 4 5. 1,5V Alkaline AAA type batteries... 3 2. TECHNICAL SPECIFICATIONS 2.1 Electrical and Mechanical Characteristics Battery type... 1,5V Alkaline AAA type LR03 (IEC) / 24A (ANSI/NEDA) Number of batteries... 3 Battery operation time... ~12 months* Wireless band... ISM868/ISM915 Range of operating temperatures... -30...+55 C (-22... +131 F) Humidity... 0-90% RH @ 0... +40 C (0-90% RH @ +32... +104 F) (non-condensing) Dimensions... 140x100x18mm (5.51x3.94x0.71in) Wireless communication range... Up to 30m (98.43ft) in premises; up to 150m (492.13ft) in open areas Compatible with alarm systems... ELDES Wireless * This operating time may vary in difference conditions. 2.2 LED Functionality ARMED READY SYSTEM BYPS Steady ON - alarm system is armed / exit delay in progress; flashing - Configuration mode activated Steady ON - system is ready no violated zones and tampers Steady ON - system faults; flashing - violated high-numbered zones Steady ON - zone bypass mode 1-12 Steady ON - violated zone / flashing - violated tamper (only for EPIR/EPIR2/EPIR3) 2 EN USER MANUAL EKB3W V1.6

2.3 Keys Functionality [BYPS] [CODE] Zone bypass mode System fault list / violated high-numbered zone indication / violated tamper indication (only for ESIM364) / violated highnumbered tamper indication (only for EPIR/EPIR2/EPIR3) [*] 1st character for Configuration mode activation/deactivation command (for ESIM364 up to v02.06.20; EPIR all versions; EPIR2 up to v1.01.08) / clear typed in characters / keypad partition switch (if enabled; only for ESIM364 up to v02.06.20) [#] Confirm (enter) command [0]... [9] Command typing [1]... [2] Keypad partition switch (for ESIM364 v02.07.00 and up) [STAY] [INST] Manual system arming in Stay mode 1st character for Configuration mode activation/deactivation command (for EPIR2 v1.01.11 and up; EPIR3 all versions; ESIM364 v02.07.00 and up) 2.4 Main Unit & Connector Functionality 1 FRONT SIDE Up to hardware version EKB3W-20 2 ARMED READY SYSTEM 1 2 A B BYPS 7 8 1 2 3 4 5 6 STAY BYPS + BATTERY - - BATTERY + EKB3W-20 3 4 5 6 9 10 11 12 7 8 9 * 0 # INST CODE TAMPER + BATTERY - 5,6 kohm Z1 TAMPER Tamper switch + / - Battery slots Common terminal Hardware version EKB3W-21 and up BATTERY + - EKB3W-21 Z1 Security zone terminal BATTERY + - BATTERY + - TAMPER 5,6 kohm Z1 USER MANUAL EKB3W V1.6 EN 3

3. INSTALLATION NOTE: Before installing the wireless device, we highly recommend to refer to RADIO SYSTEM INSTALLATION AND SIGNAL PENETRA- TION manual located at www.eldes.lt/download 1. Detach the keypad holder from EKB3W front side. 3 2. Connect a sensor and the resistor across Z1 and terminals in accordance with zone connection Type 1 or Type 2. 4 Z1 EKB3W 5,6 kω Normally open contact with 5,6KΩ end-ofline resistor. NO Magnet Type 1 Example of magnetic door contact wiring 5 Z1 EKB3W 5,6 kω Normally closed contact with 5,6KΩ end-ofline resistor NC Magnet Type 2 Example of magnetic door contact wiring 3. Mount the keypad holder on the wall using the screws. 6 4 EN USER MANUAL EKB3W V1.6

4. Remove the plastic tab inserted between one of the battery terminals and battery slot contacts. 7 5. Insert the keypad into the holder. 8 CLICK 6. Pair the device with the alarm system using ELDES Configuration Tool software. Open Wireless Device Management section and enter a 8-digit wireless device ID located on the EKB3W enclosure and press Add button. The device can also be paired by sending a corresponding command via SMS message. For more details, please, refer to the software s HELP section and ELDES alarm system installation manual. 9 7. Upon the successful pairing process, the message indicated next to EKB3W device icon will turn to CONNECTED. If the attempt to pair is unsuccessful, try to move EKB3W closer to the ELDES alarm system and pair anew. 8. EKB3W keypad is ready for use. ATTENTION: Before fixing the keypad into the holder, please make sure that the tamper is properly pressed (see fig. #2). NOTE: By default, the keypad zone and tamper is enabled, therefore a resistor supplied with the EKB3W keypad must be connected to the keypad zone terminal and the tamper switch must be properly pressed in when inserting the keypad into the holder. By disabling the keypad zone, the keypad tamper will disable as well (see ELDES alarm system installation/user manual to find out how to disable zones and tampers. NOTE: If you are unable to pair the wireless device, please restore the parameters of the wireless device to default and try again (see chapter 6. RESTORING DEFAULT PARAMETERS). USER MANUAL EKB3W V1.6 EN 5

4. EKB3W ZONE AND TAMPER Upon successful EKB3W device pairing process,the system adds 1 wireless Instant-type zone intended for wired detection device connection, such as magnetic door contact. In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper viola tion on EKB3W: By tamper switch. EKB3W comes equipped with a built-in tamper switch intended for enclosure supervision: The tamper switch is located on the back of the PCB supervising the back side of the enclosure in case the device is illegally detached. Once the enclosure of EKB3W is tampered, the tamper switch will become triggered. This action will be followed by alarm, resulting in sending an SMS text message and/or phone call to the user. The SMS text message contains the violated tamper name. By wireless connection loss. The wireless connection loss between EKB3W and ELDES alarm system leads to alarm. The system identifies this event as a tamper violation and sends an alarm by SMS text message and phone call to the listed user phone number, by default. The SMS text message contains the wireless device model, wireless ID code and tamper name. The user will also be notified by SMS text message as soon as the wireless signal is restored. ATTENTION: The tamper will not operate if the wireless zone is disabled. 5. BATTERY REPLACEMENT 1. Open EKB3W enclosure. 2. Remove all 3 old batteries from the battery slots. 3. Position the 3 new 1,5V alkaline AAA type batteries according to the appropriate battery slot positive/negative terminals indicated on the PCB (printed-circuit-board) of EKB3W. 4. Insert the batteries into the battery slots. 5. Batteries replaced. See chapter 3. INSTALLATION for more details. ATTENTION: Only 1,5V Alkaline AAA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old batteries with the new ones. ATTENTION: At least 1 battery must be removed if the device is not in use. ATTENTION: In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, disassemble, heat or incinerate old batteries. NOTE: The system sends an SMS text message to the listed user phone number as soon as the battery level runs below 5%. NOTE: The battery status can be monitored in real -time using ELDES Configuration Tool software. 6. RESTORING DEFAULT PARAMETERS 1. Remove one battery from EKB3W. 2. Press and hold the [*] key. 3. Insert the battery back to EKB3W. 4. Hold the [*] key until LED READY starts flashing. 5. Wait until LED READY turns off and LED ARMED starts flashing. 6. Release the [*] key. 7. Parameters reset to default. 6 EN USER MANUAL EKB3W V1.6

7. ADDITIONAL INFORMATION Limited Liability The buyer must agree that the system will reduce the risk of fire, theft, burglary or other dangers but does not guarantee against such events. ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system. ELDES UAB liability according to local laws does not exceed value of the purchased system. ELDES UAB is not affiliated with any of the Internet providers therefore is not responsible for the quality of Internet service. Manufacturer Warranty This device carries a 24-month warranty by the manufacturer ELDES UAB. Warranty period starts from the day the system has been purchased by the end user. The warranty is valid only if the system has been used as intended, following all guidelines listed in the manual and within specified operating conditions. Receipt must be kept as a proof of purchase date. The warranty is voided if the system has been exposed to mechanical impact, chemicals, high humidity, fluids, corrosive and hazardous environment or other force majeure factors. Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: DO NOT use the system where it can be interfere with other devices and cause any potential danger. DO NOT use the system with medical devices. DO NOT use the system in hazardous environment. DO NOT expose the system to high humidity, chemical environment or mechanical impacts. DO NOT attempt to personally repair the system. The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that the product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environment, the product must be disposed on in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in your area. Copyright ELDES UAB, 2015. All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB. ELDES UAB reserves the right to update or modify this document and/or related products without a warning. Hereby, ELDES UAB declares that this wireless LED keypad EKB3W is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt USER MANUAL EKB3W V1.6 EN 7

Made in Lithuania. www.eldes.lt