P2000 and Metasys System Integration

Similar documents
P2000 and Metasys System Integration

P2000 Security Management System Express Edition Version 3.14 SP5

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

Ademco Vista Alarm Panel

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Introduction. Introduction

GMS GRAPHICAL MANAGEMENT SYSTEM

System Galaxy Quick Guide

Fire Operator Workstation (Fire OWS) User s Guide

Access CONTROL. MANAGEMENT Software

ARCHITECTURAL AND ENGINEERING SPECIFICATION

OnGuard 7.2 Resolved Issues

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

USD 380 Centralia, Frankfort & Vermillion

Single Story Enclosed Shopping Mall Smoke Control with FSCS Override - Metasys System Extended Architecture

Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance

Metasys Integrator Cleaver-Brooks Application

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

Advisor Advanced Mobile Application User Manual

Access control hardware portfolio

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

OnGuard 7.1 Resolved Issues

Building Integration System. Your platform for customized security and safety management.

Perimeter Product Overview. Effective protection for your business

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Avigilon Control Center 5 System Integration Guide

DVTEL DVR Interface. DigiOp DVR Interface

Section PERIMETER SECURITY SYSTEMS

DATA SHEET ESS-ACS WE INDENTIFY SECURE AND INTEGRATE. IRIZ ID TECHNOLOGIES

Tyco Security Products Acquires Innometriks Deal strengthens TSP s Solutions in the Government Market

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

DX-9100/9120 Weekly Testing of Dedicated Stairwell Pressurization Fans

Gallagher System Integrations

Multistate Alarm. Introduction

Monitoring Operator Guide. Access Control Manager Software Version

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Boztek Solutions` PLAYSTATE

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

OpenDevice Events Guide

DX-9100/9120 Warehouse Smoke Exhaust and Reset Logic for a Rooftop Unit

Simplex Panel Interface Guide

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

Reciprocating Chiller

Complexity made simple

Bosch TCU Integration Module Administrator's Guide

Features and Advantages

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

BOSCH GV4 Alarm Panel

ZIPAMINI. Smart Home Controller. make your home smart. Control your home from anywhere in the world. find out more at

Verasys System Operation Overview Technical Bulletin

AC2000 Security Hub Security and Event Management System

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

York 25-Ton VAV Rooftop Unit

This technical update applies to Pro-Watch Software Release 3.5 and later.

Architectural and Engineering Specification for a Security Management System. StarNet 2

U ser's Guide PC6010

Model Number(s): WiFi Thermostats: 8840, 8830, 8820, 8810 Models Tested: 8820 rev 1.04

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Secure Your Way of Life. Now Compa ble With. Vesta Smart Security Solution ML Series

Metasys Integrator TITUS Application

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Experion LX Direct Station Specification

Scalable Access Control System with Building. Automation. WEBINARIUM 1/2018 RACS 5 System Introduction. Rev A

Using ANM Mobile CHAPTER

Avigilon Control Center System Integration Guide

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Fike Safety y Technology Ltd

ABLOY REMOTE. Intelligent high security with wire-free key control. An ASSA ABLOY Group brand

Pro-Watch Software Suite. Architect and Engineering Specifications. January 9, 2002 Revision 3.4

Avigilon Control Center 5 System Integration Guide

Access Control (card access)

Using the Room View Window

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

UNC100 Integra Manual

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Alarm Monitoring and Management

Cardax System Comparison

Complete Security Solution

Ovation Alarm Management System

Gallagher Perimeter Product Overview

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

A Smart & Integrated Security solution

Technical Publications. FactoryTalk Alarms and Events System Configuration Guide

Integrated Security Solutions

MultiSite Manager. Setup Guide

Lonix Access Control Operation & Maintenance Manual

EC-BOS-602/616 AX Security

Metasys System Extended Architecture Smoke Control System

Transcription:

P2000 and Metasys System Integration Product Bulletin Code No. LIT-12011781 Software Release 3.12 Issued June 20, 2013 Supersedes April 20, 2012 Refer to the QuickLIT Web site for the most up-to-date version of this document. The Johnson Controls P2000 Security Management System supports the integration with the Metasys Building Management System, which uses web-based technology to monitor and supervise facility controls such as HVAC; lighting; and fire control systems. This high-level integration gives Metasys operators the ability to access certain key security management features of the P2000 from the Metasys Web-based user interface. See Figure 4 on page 2. The Metasys operator can use the interface to view P2000 Host and Panel () objects, view alarms and messages, send access control commands, print reports, and create interlock events, which enable the Metasys system to react to an event from the P2000 system. Figure 1: View P2000 Objects from the Metasys Interface Table 1: Features and Benefits (Part 1 of 2) Features Benefits Building Control and Security Management Integration Integrated User Interface Alarm Management Door Control Interlocks Status Monitoring Provides significant savings. Facility costs can be reduced by increasing energy efficiency (for example, presenting a valid badge at an access control entry point triggers lighting and temperature controls in the room). When an area of the building is unoccupied, lights and temperature control can be turned off, saving the company money on electricity costs. Allows a single user to monitor both the HVAC and lighting system and security system, eliminating the need for two separate users at certain non-prime hours. Enables Metasys operators to receive, acknowledge, snooze, and discard alarms for registered P2000 devices. See Figure 11 on page 6. Enables Metasys operators to issue P2000 door commands from the Metasys user interface (see Figure 8 on page 5). The operator can choose to lock or unlock a single door or all doors, as necessary, managing the accessibility through specified access points without having to find and log on to a P2000 workstation. For example, Metasys operators can send a command to lock (override) doors during a security breach or threat. Offer customized event trigger and action sequences (cause and effect) between the Metasys and P2000 systems (see Figure 2 on page 2). Interlocks are events generated on the P2000 resulting in actions on Metasys objects. For example, a motion detection input triggered in the P2000 system can turn on a light controlled by the Metasys system, giving guards the visibility to track a potential intruder. Interlocks can only be configured on the P2000, and are unidirectional from the P2000 to Metasys. Allows Metasys operators to monitor the status of P2000 controllers, doors, input points, and output points using the Metasys Web interface, enabling them to take action (see Figure 10 on page 6). Door status changes can indicate a possible breach, and device status changes can indicate a possible hardware or software issue that may require immediate attention. P2000 and Metasys System Integration Product Bulletin 1

Table 1: Features and Benefits (Part 2 of 2) Features (Continued) Benefits Output Point Control Event Monitoring and Message Forwarding Allows Metasys operators to control P2000 output points using the Metasys Web interface. See Figure 9 on page 6. Provide Metasys operators with forwarded P2000 filtered history transaction (see Figure 3) and alarm events through the Metasys event repository, allowing Metasys operators to view P2000 Real Time messages. For example, operators can track cardholder access through the building using the Metasys interface, as each access grant event message indicates the cardholder, access point, and time when the P2000 system granted access. Figure 3: Filter Messages for Metasys Operators Figure 2: Create P2000/Metasys Interlock Events Metasys Operator MONITOR Metasys System Monitors P2000 Alarms and Events P2000 Access Point Metasys Operator Sends Commands to P2000 System CONTROL Figure 4: P2000 and Metasys System Integration 2 P2000 and Metasys System Integration Product Bulletin

Integration Overview In a Metasys environment, registered devices and objects can be accessed using Metasys Web Services. The P2000 must first be enabled with Web Services to be used by the Metasys system. Once correctly installed, available P2000 functions are visible, and the Metasys operator is able to read or change object attributes, or send commands to the objects. The P2000 folder in the Metasys Site Management Portal contains a subset of P2000 objects. The Panels folder contains configured portals (or readers), inputs, and outputs. See Figure 5. Device P2000 HostEngine Panels Panel #1 Portals Portal #1 Portal #2 Portal #N Inputs Outputs Input #1 Input #n Output #1 Output #N 0 - N 0 - N Inputs Iterm #1 Iterm #2 Iterm #N Input #1 Input #N 0 - N Outputs Panel #2 Figure 5: P2000 Objects Visible in Metasys System P2000 and Metasys System Integration Product Bulletin 3

Systems Integration Architecture Communications between the P2000 and Metasys systems occurs over an IP network. Figure 6 displays a possible integration configuration using Johnson Controls security products, such as the CK721-A and S321-IP controllers. Web Browser Printer Tower IP Network Wide Area Network (CK721-A) (S321-IP) (NAE) (NAE) Reader Module (RDR2SA) Lighting HVAC Readers Readers Figure 6: Possible Integration Configuration (Johnson Controls Security Products) Supported Johnson Controls Security IP s CK721-A network controller S321-IP network controller CK720 network controller CK705 network controller S321-DIN controller (requires Digi One SP serialto-ethernet converter). Note: P2000 serial controllers and associated portals, inputs, and outputs also appear as objects in the Metasys system Web interface. Note: S321-DIN controller requires P2K-P-SER12 P2000 option. Supported Third-Party IP Readers/s The P2000 also supports the monitoring and control via the Metasys system Web interface of controllers, portals, inputs, and outputs associated with the following third-party controllers/readers integrated with the P2000 system (see Figure 7 on page 5): HID Edge Readers PowerNet Readers (powered by ISONAS) Stanley OMNILOCK Wireless Readers ASSA ABLOY SARGENT and Corbin Russwin Wired and Wireless Door Locks Note: For information on specific controller/reader models supported, refer to the Third-Party IP Reader/ Integration Catalog Page (LIT-1900646). Note: The P2000 and Metasys Integration supports limited monitoring and control of ASSA ABLOY locks. See Table 2 on page 5 and Table 3 on page 6 for details. 4 P2000 and Metasys System Integration Product Bulletin

Web Browser (NAE) Tower IP Network Wide Area Network Stanley OMNILOCK Wireless Gateway HID Edge Reader (Wired) ASSA ABLOY Reader (Wired) ASSA ABLOY Reader (Wireless) PowerNet by Isonas Reader (Wired) OMNILOCK Reader (Wireless) Figure 7: Possible Integration Configuration (Integrated Third-Party Security Products) Supported Commands Metasys operators can send P2000 commands from the Metasys Web interface. See Table 2. Table 2: Supported Commands Item Supported Commands Portals (Doors) 1 Unlock All Doors Lock All Doors Unlock selected door for n seconds or minutes according to the door s Access Time setting Unlock selected door for n minutes 2 (not associated with Access Time) Lock selected door until a unlock command is issued Outputs Reset Set 2. Not supported on wired ASSA ABLOY door locks. Figure 8: Send P2000 Door Commands from Metasys Interface 1. The P2000 and Metasys Integration does not support door commands on wireless ASSA ABLOY door locks. P2000 and Metasys System Integration Product Bulletin 5

Figure 10: View Current State of Devices Figure 9: Send P2000 Output Point Commands from Metasys Interface Status Monitoring Metasys operators can monitor the status of various devices. See Table 3. Table 3: Supported Status Values Item Supported Status Values s Normal Trouble Unreliable Offline Portals (Doors) Online Offline Unlocked 1 Locked 1 Disabled Overridden 1,2 Unknown Inputs Set Reset Open Short Secure Suppressed Unknown Outputs Set Reset Fault Alarm Management Metasys operators can use the Metasys system Web interface to manage P2000 alarms and take appropriate action. Supported alarm management features include: Viewing P2000 alarms Acknowledging P2000 alarms Discarding P2000 alarms Viewing a graphic reference associated with a P2000 alarm Figure 11: View P2000 Alarms from Metasys Interface 1. Not supported on wireless ASSA ABLOY door locks. 2. Not supported on wired ASSA ABLOY door locks. Figure 12: Select P2000 Alarms to Discard 6 P2000 and Metasys System Integration Product Bulletin

Viewing P2000 Status Changes with a Metasys Graphic Metasys graphics can provide a visual representation of certain components of a P2000 system and enable Metasys operators to quickly check their status and recognize unusual P2000 system conditions. For example, operators can use a Metasys graphic to quickly view the status of a portal based on the color displayed by a dynamic symbol created in the Metasys system s User Graphics Tool (UGT). IP Network Tower Site Directors Registered in P2000 NAE Tower NAE Wide Area Network Figure 13: Bind Symbols to P2000 Objects Site Director Registration P2000 and Metasys systems integration requires the registration of the P2000 server with a Metasys Site Director. A Metasys Site Director can be one of the following: Application and Data Server (ADS) Extended Application and Data Server (ADX) Network Automation Engine (NAE) Note: We recommend using an ADS or ADX as the Site Director whenever possible. P2000 enables you to create multiple registration definitions, so you can register the P2000 server with multiple Site Directors (see Figure 14). Figure 14: Registering the with Multiple Site Directors In addition, operators may register certain partitions with a particular Site Director, so that only those P2000 objects associated with the selected partitions are visible from the Metasys system (see Figure 15). Partitions enable the P2000 database to be divided into smaller sections, or partitions, that can be individually managed. These partitions define what data is available to an individual user or to a group of users. 1 NAE 1 Metasys Client 2 NAE 2 Partition A Partition B Partition C Figure 15: Using P2000 Partitions with Multiple Site Directors P2000 and Metasys System Integration Product Bulletin 7

In the example in Figure 15 on page 7: The P2000 objects associated with Partition A are only visible from 1 and NAE 1. The P2000 objects associated with Partition B are only visible from 2. The P2000 objects associated with Partition C are only visible from 2 and NAE 2. Supported Metasys Software Versions P2000 Version 3.12 supports the following Metasys system software releases: Version 5.2 Version 5.1 Version 5.0 Version 4.1 P2000 Software Requirements The P2000 and Metasys systems integration requires the following software be installed on the P2000 system: Operating system and database server as required for the P2000 system P2000 Prerequisites Version 3.12 Microsoft Internet Information Services (IIS) as required for the P2000 system P2000 Software Version 3.12 Note: For all P2000 software installation requirements and supported platforms, refer to the P2000 Software Installation Manual (Part No. 24-10685-130). Ordering Information The P2000 and Metasys systems integration cannot be ordered separately. It is included in the following P2000 software package: Table 4: Ordering Information Product Code Description Number P2K-SW-CORE312 Related Documentation Fully expandable base P2000 system that supports 5 concurrent user connections via thin or thick clients. Includes all of the standard P2000 features. In addition, provides support for the following: Metasys Integration, Elevator Control, Cabinet Control, Guard Tour, High Availability, Remote Server Connections, Message Filtering, Serial Panels, Intercom, and P2000 Workstations. Also supports 25,000 cardholders. Table 5: Related Documentation Document Title Document Number P2000 Metasys System Integration Manual Part No. 24-10685-106 P2000 Software User Manual Part No. 24-10685-157 Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2013 Johnson Controls, Inc. 8 P2000 and Metasys System Integration Product Bulletin Published in U.S.A. www.johnsoncontrols.com