A Glossary of HVAC Terms

Similar documents
QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Managing HVAC in High Performance Buildings

2019 Smart Energy Existing Homes Program Manual

The Benefits of a Complete Heating and Cooling System.

Reviewing HVAC Designs for Compliance with ACCA Manual S

96% WARMTH COMFORT. WELL-BUILT since 1914 SINCE 1914, WE VE BEEN DELIVERING ON OUR PROMISE

Making equipment decisions

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Performance 14 Packaged HYBRID HEAT Dual Fuel System with Puron Refrigerant

EXHIBIT 1. Washington Home Energy Savings

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Air Conditioner with Puron Refrigerant MODEL 126B

Packaged Gas Heat/ Electric Cool Unit

CHAPTER 1 INTRODUCTION

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Heat pump and energy recovery systems

Refrigerant. Heat Pump with Puron MODEL 285B

Become An Empowered ACCA Manual J, S & D Consumer!

The Benefits of a Complete Heating and Cooling System.

Air-Conditioning Buying Guide

Two-Stage Heat Pump with Puron

Infinity 21 Air Conditioner with Puron Refrigerant

HIGH EFFICIENCY WEATHERMAKER 38TPA

HVAC for Raters & Inspectors

Infinity 16 Heat Pump with Puron Refrigerant

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

Air Conditioner with Puron MODEL 186B

Lifestyle Selling = Consumer Choices

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

Energy Management and Controls

2018 Smart Energy Existing Homes Program Manual

Infinity 19 Heat Pump with Puron Refrigerant

HVAC Equipment and Systems

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Two-Stage Air Conditioner with Puron Refrigerant

AND WORRY-FREE PERFORMANCE

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Two-Stage Air Conditioner with Puron Refrigerant MODEL 187B

16.0. High-Efficiency Heat Pump Designed with Your Comfort in Mind. Performance Series Heat Pumps with Puron Refrigerant

Air Conditioner with Puron

Appendix A. Glossary of Common Terms

HVAC Equipments and Systems

Infinity 19 Heat Pump with Puron Refrigerant

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Infinity 15 Packaged Heat Pump System With Puron Refrigerant

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

A HOMEOWNERS HANDBOOK AIR CONDITIONING

Explanation of Cooling and Air Conditioning Terminology for IT Professionals

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Chapter 10. Refrigeration and Heat Pump Systems

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

healthy comfort Indoor Air Quality Solutions

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Lennox MERIT SERIES. Innovative Solutions for a Comfortable Home Environment

1. Dial Down. 10 Energy Saving Tips for the Home

COURSE NUMBER COURSE NAME COURSE DESCRIPTION

High Performance Building Guide 1

Smart Energy Existing Homes Program Manual

The evil that men do lives after them; the good is oft interred with their bones.

Energy Recovery Ventilation

The XP17 provides comfort without comparison.

The XC17 is an efficiency expert.

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

HFCs or the Old Refrigerants - what is the best Choice?

The PureAir system improves air quality throughout your home.

CHAPTER 4. HVAC DELIVERY SYSTEMS

HVAC Fundamentals & Refrigeration Cycle

Things to Consider Before You Buy

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Geothermal Heat Pump Systems

PART 5: HVAC & DHW SYSTEMS

Temperature. In the HVAC area, we talk about two kinds of temperatures.

COMcheck Software Version Mechanical Compliance Certificate

TRANE XLi HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE. Exceptional heating and cooling all year long READ ONLY. TRANE XLi HEAT PUMPS

READ ONLY THE COOL SIDE OF TRANE. TRANE XLi AIR CONDITIONERS. TRANE XLi AIR CONDITIONERS. Exceptional air conditioning for your home

Missouri HERO Program Residential Eligible Product List

healthy comfort Indoor Air Quality Solutions

Air Conditioning and process cooling Energy Components at a Glance

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Overview. Heating and Cooling System Strategy

Residential HVAC System Design

ENERGY STAR v3.0 HVAC Checklists

ENGINEERING. Edition No. 13 October 2002

Fundamentals of Refrigeration p. 25 History and Fundamentals of Refrigeration Module p. 25 Development of Refrigeration p. 25 How a Mechanical

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

Heating Colorado Homes

Come home to perfectly quiet and efficient comfort.

Original Article PERFORMANCE ANALYSIS OF FINNED TUBE AIR COOLED CONDENSING UNIT OF SPLIT AIR CONDITIONER

Appendix 13. Categories of Cooling and Heating systems

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Heating and Cooling IN THIS CHAPTER

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

CAE 331/513 Building Science Fall 2017

Transcription:

A Glossary of HVAC Terms Confused by the many terms and acronyms surrounding your indoor comfort system? Don t be! This handy glossary of terms will tell you what you need to know when discussing your HVAC system with a professional contractor. 13 SEER This is the new minimum efficiency standard (effective January 2006) for an air conditioner or heat pump. All new units must now meet this standard. Previously manufactured equipment may be used, sold, and installed. SEER is defined later. ACCA The Air Conditioning Contractors of America, a national trade association that represents heating, ventilation, air conditioning, and refrigeration contractors. AIR HANDLING UNIT Equipment with a heating element and/or cooling coil and other components in a cabinet or casing. AHRI Air-Conditioning, Heating and Refrigeration Institute, a non-profit, voluntary organization composed of heating, air conditioning and refrigeration manufacturers. AHRI publishes standards for testing and rating heat pumps and air conditioners. BALANCING or AIR BALANCING Adjusting an air conditioning system so that the right amount of air is delivered to the right places in your home in order to achieve the right heating or cooling effect. BTU British Thermal Unit, the measurement of heating and air conditioning capacity. A BTU is the amount of heat that must be added to one pound of water to raise its temperature one degree Fahrenheit. CFC Chlorofluorocarbons, used as a refrigerant in air conditioners and heat pumps, linked to the depletion of the ozone layer. COP Coefficient of performance, an efficiency ratio that compares the amount of heat delivered to the amount of energy used. As with MPG on a car, the higher the score the more energy efficient the equipment is. COIL A heating or cooling element made of pipe or tubing, usually with plates or fins.

COMMISSIONING The final step in installing a heating or air conditioning system. Every component is checked and tested for compliance with codes, ACCA manuals, manufacturer requirements, and occupant needs. After commissioning, the technician will: provide documentation of testing, provide all equipment manuals, and show the homeowner how to operate the system. CONDENSER (HEAT EXCHANGER) The outside unit of a heating or air conditioning system. Here the refrigerant condenses from a gas to a liquid and hot or cold air from the building is released to the outside. DEHUMIDIFIER A device that removes excess moisture from the air. DOE The U.S. Department of Energy, the federal agency that sets industry efficiency standards. DUCT Conduits used to carry air. They can be round or rectangular, sheet metal or fiberglass or vinyl tubes. In air conditioning systems they carry air from the home to the air conditioning system or furnace and back to the home. ERV Energy Recovery Ventilator, a machine that draws fresh air into the home and exhausts stale air from the home. It uses a process to preheat or pre-cool (depending on the season) to reduce energy costs associated with conditioning the air. ENERGY STAR A government supported branding used to identify energy efficient products. The branding was developed by the US Department of Energy and the US Environmental Protection Agency. EPA The U.S. Environmental Protection Agency. FAN COIL See AIR HANDLING UNIT FURNACE A self-contained heating unit that is designed to deliver heated air to a home. GAMA Gas Appliance Manufacturing Association is a national trade association serving the interests of manufacturers of gas, oil, and electric appliances and equipment,

components and related products used in residential, commercial, and industrial applications. HCFC Hydrochlorofluorocarbons, used as a refrigerant in air conditioners and heat pumps. HCFCs were thought to contribute to the depletion of the earth s ozone layer. HEAT EXCHANGER 1. The part of a furnace that transfers heat from burning fuel to the air used to heat your home. Also, from a boiler to water for hydronic heating. 2. A device, such as a condenser or evaporator, in which heat is added or removed in order to heat or cool your home. HEAT PUMP A single refrigeration system designed to provide both heating and cooling. Compare to a furnace and an air conditioner, separate units that only heat or cool. HRV Heat Recovery Venilator, a machine that brings fresh air into a home through a process that preheats the air so it has less impact on your utility bill. HFC Hydroflorocarbon, used as a refrigerant in air conditioners and heat pumps. It has little or no effect on the ozone layer. HSPF Heating Seasonal Performance Factor, an equipment efficiency rating. As with MPG on a car, the higher the rating the more fuel efficient the equipment is. HUMIDIFIER A device that adds moisture to warm air for your home. HVAC Heating, ventilating, and air conditioning HVACR Heating, ventilating, air conditioning, and refrigeration INFILTRATION Air that enters your home through holes, gaps, and cracks, (e.g., plumbing or electrical holes, the heating and air conditioning system, doors, and windows). IAQ Indoor air quality

LATENT HEAT The energy that suspends moisture vapor in the air. LOAD CALCULATION A mathematical determination of how much cooling and heating (BTUs) an HVAC system must deliver for occupant safety and comfort. It is based on a variety of factors: square footage, building orientation, number of occupants, size and placement of rooms, number and size of windows and doors, amount of insulation, number of floors, and climate. MANUAL D An ACCA procedure covering the proper design, installation, maintenance, and repair of ductwork. MANUAL J An ACCA procedure covering the method for calculating heating and cooling requirements (load calculation) for single-family detached homes and mobile homes. MANUAL RS An ACCA publication covering the design, installation, and commissioning of a residential HVAC system. MATCHED SYSTEM An air conditioner or heat pump system composed of equipment that has been certified by ARI to work together to deliver the specified heating and cooling capacity at the stated efficiency rating. MOLD A natural byproduct of the fungi family that thrives when organic substances and water combine under certain circumstances. Mold reproduces via spores that can remain dormant, yet viable, for years. Many molds are beneficial. For example, they are the bleu in bleu cheese, and we use them to make wine, penicillin, and antibiotics. However, some molds can cause health problems. NATE North American Technician Excellence, the nonprofit organization that tests and certifies HVACR technicians. PMA Planned maintenance agreement, which provides regular maintenance of your HVACR system. Most ACCA member contractors offer PMAs, although they may use different names for them, such as Maintenance Inspection Agreement, Planned Service Agreement, Energy Service Plan, etc. R-22 A refrigerant containing chlorine used in air conditioning systems. The EPA has

mandated that R-22 cannot be manufactured after 2010 because it has been linked to the depletion of the ozone layer and global warming. Most commonly referred to by its trademarked name, Freon. R-410A The refrigerant that replaces R-22. It does not contain chlorine and is not hazardous to the environment. REFRIGERANT A fluid that absorbs heat at low temperatures and rejects heat at higher temperatures. REFRIGERANT CHARGE (or, charging the refrigerant ) The procedure an HVACR technician performs to ensure that the system has enough of the right kind refrigerant for peak operating performance. RELATIVE HUMIDITY (RH) The percent of moisture actually in the air compared to the maximum amount of moisture the air can hold at that temperature. RETURN, RETURN AIR, RETURN SIDE The path the air takes to get to an air-handling unit or furnace so it can be cooled or heated. It is the return path. The return side should be balanced with the supply side to ensure proper air flow and comfort. SEER Seasonal Energy Efficiency Ratio, an equipment efficiency rating that measures how much energy it takes to cool the air. As with MPG on a car, the higher the number the more efficient the unit. SENSIBLE HEAT The temperature of the air. This type of heat is measured with a thermometer. SPLIT SYSTEM A two-component heating and cooling (heat pump) or cooling only (air conditioner) system. The condensing unit is installed outside, the air handling unit is installed inside (preferably in conditioned space). Refrigerant lines and wiring connect them together. SUPPLY or SUPPLY SIDE The part of an HVAC system that takes (supplies) the conditioned air from the airhandling unit or furnace to your home. The supply side should be balanced with the return side to ensure proper air flow and comfort. ZONES, ZONED SYSTEM, ZONING A single HVAC system that can meet different heating and cooling needs in different areas (zones). Each zone of a home has its own thermostat with which it can regulate the temperature and humidity in its area. One zoned air conditioner could be set for a

high temperature in one zone and for a lower temperature in the other zone. Zone systems have two or more zones.