Power X High Power Condensing Wall-Hung Boilers

Similar documents
Power X High Power Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers

MySMART Condensing Wall-Hung Boilers

Exclusive Green E Condensing Wall-Hung Boilers

Mynute Green Condensing Wall-Hung Boilers

Tower Green HE Hybrid

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

International Markets. Product Catalogue. complementary items

1 VICTRIX ZEUS Superior kw I features

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

ENERGY TOP. Condensing boiler solutions

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

SPECIFICATIONS - NIKE

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

CAST IRON ATMOSPHERIC BOILERS

The iqe Boiler Range. Combination and System T Boilers.

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Seradens Super Seradens Super Plus

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

C Tahiti. condensing

MINORCA KC - KR - KRB 24

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

HEAT ONLY & COMBI BOILER

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

Condensing, pre-mixed, wall-hung gas boilers with water tank

ACCUMULATION OF EUROPEAN CLASS

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Ideasandformsinevolution

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Compact HRE Boiler Range. The smart choice for heating and hot water

Floor standing boilers. RMG Mk.II RS Mk.II

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Residential Heating Boilers

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

CITY OPEN - CITY BOX from 25 to 35 kw

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

FORMENTERA KC - KRB - KR

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Our Boiler Family Our Boiler Family

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

Capri B Cast iron combination oil-fired boiler with water tank

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

MAIOR EOLO 4 E. Instantaneous wall-hung boilers, sealed-room with "Aqua Celeris" system MAIOR EOLO 4 E

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

RIELLO 40 GS/M SERIES

Flue gas condensation...

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

WOLF GAS CONDENSING BOILERS COMFORTLINE

Wall hung combination

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Rapid. Suspended Warm Air Heater. Caring for the environment!

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

VERVE I 50. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

D O M E S T I C Solar Thermal

October Solar Thermal

solar storage cylinder

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

4FLOOR-STANDING GAS CONDENSING BOILERS

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Light commercial products. High output boilers Cascade systems

white blue cobalt bordeaux light oak (rovere)

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

Sirius WH. Working towards a cleaner future

Transcription:

Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant

POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power range by Beretta Power X is a high power condensing wall-hung boiler, designed for light commercial applications, like villas and multi-dwelling units. It comes in models that, thanks to a complete range of accessories, can be configurated in different ways, according to your installation and comfort needs: - Power X 0 (only heating model); - Power X R.S.I., 0 DEP R.S.I., 0 R.S.I. (only heating models with built-in -way valve).

TECHNOLOGY AND CONTROL Simple and user-friendly control panel Power X is featured by a simple and user-friendly digital display that provides the end-user immediately with all information about the boiler status. The touch buttons allow to easily select all the functions necessary to the use and setting of the boiler. 2 KEY: Digital display for information about boiler status 2 Digital display for heating/dhw temperature setting ON/OFF and reset selector Touch button for central heating temperature increase Touch button for central heating temperature decrease Summer/winter selector Touch button for DHW temperature increase Touch button for DHW temperature decrease Saving energy, saving money The new energy labelling, that according to the ErP directive was implemented in September 20 for appliances and systems producing heating and domestic hot water, means that all boilers and heating systems are labelled in the same way as white goods, like washing machines and refrigerators. The energy labelling enables the end-users to make realistic comparisons among different products. By choosing high efficiency products, the end-users can lower their energy bills, helping to safeguard the environment. Seasonal space heating energy efficiency Power X R.S.I. A Energy efficiency class Sound power level 2 Rated heat output Note: The values in this label refer to POWER X R.S.I. Specifications for each model are detailed at page 9.

POWER X / High Power Condensing Wall-Hung Boilers TECHNOLOGY AND CONTROL High condensing technology The Power X condensing heat exchanger has a high exchange surface and an excellent corrosion resistance. It is made of a continuous corrugated bi-metallic tube (copper alloy on the water side and stainless steel on the flue side), coiled up inside a cylidric structure in stainless steel. This structure is closed on the upper side by a header in die-cast aluminium and on the lower side by a composite plastic header. The counter flow heat transfer is particularly advantageous as the flue temperature is lowered ( C more than the return water). The total pre-mix burner ensures a constant calibrated gas and air mix under any running conditions, translating into highest efficiency. 2 KEY 9 Fan 2 Gas valve Air inlet Flue outlet Condensate drain Ignition and flame control electrode Flow pipe Burner 9 Heat exchanger 0 Return pipe 0 Heat exchanger made of a coiled corrugated bimetallic pipe. Pre-mix burner: Low NOx Class (Directive EN ) Thermoregulation as standard with outdoor probe as option Gas Directive EEC 90/9 Low voltage Directive EEC 9/ Electromagnetic compatibility Directive EEC /2 Section of bimetallic corrugated pipe

POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers TECHNOLOGY AND ADVANTAGES New bimetallic (stainless steel - copper) condensing heat exchanger Modulation ratio : Condensate collector syphon Low Energy modulating synchronous pump (ErP compliant - EEI 0,20 ), m head, with anti-blockage cycles system Built-in ways valve with anti-blockage cycles system (on the models R.S.I, 0 DEP R.S.I., 0 R.S.I.) Electronic board with self-diagnostic function and frost protection Total pre-mix burner with low emissions: Class (UNI EN ) Possibility to directly connect a DHW tank via the built-in -ways valve (on R.S.I. models) or via an external -ways valve (on 0 model), for the production of DHW Climatic thermoregulation as standard with outdoor probe (as option) Flue gas analysis Built-in 2 lt. expansion vessel (on R.S.I. model) 2 and lt. expansion vessels available as option (for the 0 DEP R.S.I., 0 R.S.I. and 0 models) Management of three circuits: high temperature, low temperature and DHW tank T flue/water return: max C

POWER X / High Power Condensing Wall-Hung Boilers TECHNOLOGY AND EFFICIENCY Low Energy pump and differential pressure switch The Power X boiler range is equipped with the new Low Energy pump, providing a high energy saving and a significant reduction in electrical consumption. Power X also features a differential pressure switch, which detects a minimum value of flow rate and system pressure. Other hydraulic accessories and safety devices are available for Power X range (see the following pages). metres residual head residual head m.w.c. 2 0 0,0 0,2 0, 0, 0,,0,2,,, 2,0 2,2 flow rate m /h BeSMART WiFi compatible Power X is compatible with the BeSMART WiFi (as ON/OFF thermostat), the new solution by Beretta to manage your home heating from wherever you are in the world, via the BeSMART App. From any smartphone or tablet you will be able to programme your comfort in an easy and intuitive way, adapting your heating times to your lifestyle or dayly program. BeSMART WiFi is very easy and quick to install and allows to manage up to heating zones. All main heating program information are displayed on the thermostat or available via App. For further information visit our website berettaboilers.com or besmart-home.com.

TECHNICAL DRAWINGS POWER X R.S.I. POWER X 0 - POWER X 0 R.S.I. - POWER X 0 DEP R.S.I. 2 20 9 2 20 9 2 2 a b 9 0 2 9 0 2 KEY Automatic air vent valve 2 Deaerator Safety thermostat Flow sensor Condensing heat exchanger Differential pressure switch Flue temperature probe Pump 9 Return sensor 0 Safety valve ( bar) Gas valve 2 Hydrometer Built-in diverter valve (*) Syphon condensate drain a 2 lt. built-in primary expansion vessel (only on the R.S.I. model) b 2/ lt. expansion vessel as option (on the 0 DEP R.S.I., 0 R.S.I. and 0 models) Venturi Gas valve Fan 9 Air inlet 20 Flue 2 Ignition and detection electrode Note: (*) Built-in on all R.S.I. models. For Power X 0 the diverter valve is available as option (cod. 2002) to be placed outside the boiler.

TECHNICAL DRAWINGS POWER X 0 / POWER X 0 R.S.I. / POWER X 0 DEP R.S.I. / POWER X R.S.I. 0 20 0 9 Ø 0 R G M SC 2 0 0 0 0 Mb HYDRAULIC CIRCUIT F A KEY T T/F 2 2 R 0a /0b L H T P Mb M 9 G Condensing heat exchanger 2 Modulating pump Fan Automatic air vent valve Differential/minimum pressure switch Flue temperature probe Flow sensor (central heating) Return sensor (central heating) 9 Built-in diverter valve (except for Power X 0) 0a 2 lt. expansion vessel as standard on R.S.I. model 0b and 2 lt. expansion vessels as option for 0, 0 DEP R.S.I. and 0 R.S.I. models Safety valve ( bar) 2 Boiler drain Deaerator Safety thermostat A Air G Gas (M / G) F Flue R Central Heating return* (M G) M Central Heating flow (M G) Mb DHW tank flow (only on R.S.I. models) SC Condensate drain Note: (*) For the R.S.I. versions it is available the connection kit for DHW tank return (code 202).

TECHNICAL DATA FEATURES and MODELS POWER X R.S.I. POWER X 0 DEP R.S.I. POWER X 0 R.S.I POWER X 0 Product order code 2022 2022 20 20 Boiler function heating only with built-in ways valve (*) heating only ENERGY LABELLING SPECIFICATIONS (according to ERP regulation) Seasonal space heating energy efficiency class A A A A Seasonal space heating energy efficiency % 92, 92, 92, 92, Sound power level inside db,2,2,2 SPECIFICATIONS Heat input ref. Hs (HHV) min-max kw, -,0,0 -,,0-0,0,0-0,0 Heat input ref. Hi (NHV) min-max kw,2 -,, -,, -,0, -,0 Useful heat output ref. Hi (NHV) (0-0 C) kw 0,90,,20,20 Useful heat output ref. Hi (NHV) (0-0 C) kw,00,0,0,0 Quantity of condensate (0-0 C) NG l/h,,,, Useful efficiency ref. Hi (NHV) (0-0 C) % 9,00 9,20 9,20 9,20 Useful efficiency ref. Hi (NHV) (0-0 C) % 0, 0,0 0,0 0,0 Useful efficiency at ref. HI (NHV) 0% (0-0 C) % 9,99 9,0 9,0 9,0 Useful efficiency at ref. HI (NHV) 0% (0-0 C) % 09,20 0,0 0,0 0,0 Losses via the chimney with the burner operating (0-0 C)/(0-0 C) %,/0,,/0,9,/0,9,/0,9 Losses via the chimney with the burner off % 0, 0, 0, 0, Losses via the casing with the burner operating % 0,2 0, 0, 0, Flue gas temperature C Return temperature + max C NOx Class CENTRAL HEATING Maximum operating pressure bar Range of boiler water temperature settings (min/max) C 0/0 0/0 0/0 0/0 Hydraulic residual head at 000l/h bar 0, 0, 0, 0, ELECTRICAL SPECIFICATIONS Power supply V/Hz 20/0 20/0 20/0 20/0 Index of protection IP XD XD XD XD Fan power consumption W 0 00 00 Pump power consumption W 0 0 0 0 HYDRAULIC AND GAS CONNECTIONS CH flow Ø Gas inlet Ø / / / / CH return Ø TWIN FLUE PIPES AND AIR INTAKE Ø0 Max length m 2 + 2 2 + 2 2 + 2 2 + 2 Loss due to the insertion of a bend 90 / m / / / / DIMENSIONS AND WEIGHT Boiler dimensions (H x L x P) mm 9 x 0 x 9 x 0 x 9 x 0 x 9 x 0 x Dry weight kg 0 Available gas versions NG/LPG (**) NG/LPG (**) NG/LPG (**) NG/LPG (**) (*) The -ways valve kit allows the DHW production via connection with a DHW tank. (**) LPG version available through LPG transformation kit (supplied as standard) KEY: R heating only model S room-sealed I electronic ignition + ionisation flame control 9

POWER X / High Power Condensing Wall-Hung Boilers ACCESSORIES Accessories and complementary items Power X can be installed in different configurations, according to your installation needs. Beretta offers CODE HYDRAULIC/ELECTRICAL COMPONENTS and SAFETY DEVICES a complete range of accessories, designed to be perfectly combined with Power X range. CODE 209 2 lt expansion vessel kit 20022 Taps for system 2 029 External probe kit 2002 Hydraulic manifold for safety kit 009 Socket probe for DHW tank and for Low Temp. zone 2002 Safety kit (*) 2209 Limit thermostat for low temperature applications 2009 Gas safety cut-off valve 200kW 2002 Hydraulic header separator for single application 2000 2002 -way valve kit for DHW tank for single application 2000 Rear mounting kit for free-standing application 9 202 Connection kit for DHW tank return (for RSI versions) 0 2090 lt expansion vessel kit 2020 Rear spacer frame kit for wall-hung application (in case of concentric flue systems) SUPPORTS FOR INSTALLATION Power X rig (front mounting) 9 0 2 Note: (*) According to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market), the kit is composed by: INAIL type-approved safety thermostat with manual reset [00(0- C)]; INAIL type-approved thermometer (0-20 C); thermometer wellduct; INAIL type-approved safety valve (, bar); INAIL type-approved safety pressure switch with manual reset; INAIL type-approved manometer-holder -ways tap; damper coil; INAIL typeapproved manometer (0- bar); brass fitting connection. 0

ACCESSORIES - FLUES Flue adapters CODE CODE FLUES / AIR INTAKE 2002 Air-intake kit B2 9 200202 Flue adapter kit from Ø0-0 to Ø0/00 20 2002029 Flue adapter kit from Ø0-0 to Ø0/2 9 20 Ø0 twin flue system in plastic (PP) CODE CODE 20022 bend, Ø0 200222 90 bend, Ø0 200229 00 mm extension, Ø0 2002222 000 mm extension, Ø0 200222 2000 mm extension, Ø0 200222 Horizontal terminal extension L=9 mm, Ø0 20022 Air inlet horizontal terminal L=0 mm, Ø0 22099 Spacers for pipe, Ø0 ( pcs.) Ø0/00 concentric flue system in plastic (PP/PPu) CODE CODE 200292 concentric bend, Ø0-00 200220 90 concentric bend, Ø0-00 2002 00 mm concentric extension, Ø0-00 2002 000 mm concentric extension, Ø0-00 20029 2000 mm concentric extension, Ø0-00 200222 Vertical extension, Ø0-00 - external straight pipe Ø2 2002 Horizontal terminal extension, Ø0-00 0029 Spacers for pipe, Ø00 ( pcs.) Ø0/2 concentric flue system in plastic/aluminium (PP/Al) CODE CODE 099 concentric bend, Ø0-2 009 90 concentric bend, Ø0-2 09 90 concentric bend with inspection, Ø0-2 09 00 mm concentric extension, Ø0-2 029 000 mm concentric extension, Ø0-2 09 2000 mm concentric extension, Ø0-2 09 Concentric extension with inspection, Ø0-2 09 Vertical extension, Ø0-2 - external straight pipe Ø2 09 Horizontal extension, Ø0-2 20020 Spacers for pipe, Ø0-2 ( pcs.) Note: Due to exposition to sunlight, the colour of the material (PP) may be altered.

POWER X / High Power Condensing Wall-Hung Boilers DHW TANK Idra BV Idra BV is the ideal DHW tank range to be matched with Power X. It comes in different sizes that can cover all your installation and comfort needs. The two CODE installation schemes in the following page illustrate how Power X can manage a mixed system: High Temperature + Low Temperature and a DHW tank. DIMENSIONS HxØ (mm) CYLINDER CAPACITY (litres) HEAT LOSS (W) ENERGY CLASS A B C D E (mm) (mm) (mm) (mm) (mm) 2009 IDRA BV 200 0x0 20 9 B 0 0 2009 IDRA BV 00 0x0 0 9 B 0 0 9 0 20099 IDRA BV 0 0x C 20 0 0 00 0 200900 IDRA BV 0 90x 9-20 0 0 00 20090 IDRA BV 00 x000, - 2 2 0 200902 IDRA BV 000 2x000 90 2, - 90 2 200 UAC UAC ES ES H RC E RC KEY D US US UAC C EAF EAF (SB) ES RC B A US EAF Ø ACCESSORIES CODE CODE 2 20020 /2 electronic anode kit * 2 09 lt expansion vessel 22 029 Thermostatic mixing valve ¾ 2 009 2 lt expansion vessel 2 200092 Thermostatic mixing valve with ¾ adapter 2 09 lt expansion vessel 2 22 2 Note: (*) For the coupling with the electronic anode kit a reduction to /2 is needed (not included in the kit) 2 2 2 2 DHW outlet Flow DHW recirculation Return DCW inlet

SYSTEM Management of a mixed system: High Temperature + Low Temperature and a DHW tank POWER X 0 2 0 29 2 2 2 2 2 DHW ACS DCW AFS 22 POWER X 0 DEP R.S.I. These schemes have only an indication purpose 2 2 29 9 2 ACS DHW 22 DCW AFS KEY Power X 0 (20) 2 Power X 0 DEP R.S.I. (2022) Hydraulic manifold for safety kit (2002) Safety kit (2002) Gas safety cut-off valve 200kW (2009) Hydraulic header separator (2002) -way valve kit for DHW tank (2002) 9 Connection kit for DHW tank return (202) 0 lt. expansion vessel (optional kit 2090) 2 lt. expansion vessel (optional kit 209) 2 External probe kit (029) Socket probe (009) Air-intake kit B2 (2002) 22 Thermostatic mixing valve (029 or 200092) 2 DHW tank IDRA BV 2 Pump (a) 29 Motorized mixing valve (a) (b) Note: (a) Not available in the Beretta International Product Catalogue; (b) Use a mixing valve with a 2Vac stepper motor and wires, to be connected on the boiler control board to the terminals dedicated to the Low Temp. zone.

WALL-HUNG APPLICATIONS POWER X 0 DEP R.S.I. / POWER X 0 R.S.I. CONFIGURATION FOR CENTRAL HEATING AND DHW TANK 209 2 9 2, 2 22 00 00 22 2 2, BOILERS CODE Q.TY 2 2022 Power X 0 DEP R.S.I. (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 20022 Taps for system 2002 Hydraulic header separator for single applic. CODE Q.TY 9 202 Connection kit for DHW tank return FLUES / AIR INTAKE 2002 Air-intake kit B2 (B) ACCESSORIES FOR DHW TANK (C) - 009 Socket probe for DHW tank (A) The configuration illustrated in this page can be applicated also with POWER X 0 R.S.I. (code 20). Inside the Power X boilers range (except for Power X R.S.I.), it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090), or the optional expansion vessel kit of 2 lt. (code 209). (B) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/2, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 2020 (, mm depth). (C) Inside the R.S.I. models of Power X range, the -way valve for DHW tank management is already built-in (like in this condiguration).

WALL-HUNG APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING ONLY 209 0 22 00 00 2, 2, 9 2 BOILERS CODE Q.TY 20 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 2002 Hydraulic manifold for safety kit (B) 2002 Safety kit (B) CODE Q.TY - 2009 Gas safety cut-off valve 200kW (B) 2002 Hydraulic header separator for single applic. FLUES / AIR INTAKE 2002 Air-intake kit B2 (C) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090) or the optional expansion vessel kit of 2 lt. (code 209). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/2, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 2020 (, mm depth).

WALL-HUNG APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING AND DHW TANK (WITH EXTERNAL -WAYS VALVE) 209 2 2, 0 00 00 22 2 2, BOILERS CODE Q.TY 20 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 2002 Hydraulic manifold for safety kit (B) 2002 Safety kit (B) - 2009 Gas safety cut-off valve 200kW (B) CODE Q.TY 2002 Hydraulic header separator for single applic. FLUES / AIR INTAKE 2002 Air-intake kit B2 (C) ACCESSORIES FOR DHW TANK 2002 -way valve kit for DHW tank - 009 Socket probe for DHW tank (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090) or the optional expansion vessel kit of 2 lt. (code 209). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/2, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 2020 (, mm depth).

FREE-STANDING APPLICATIONS POWER X 0 DEP R.S.I. / POWER X 0 R.S.I. CONFIGURATION FOR CENTRAL HEATING AND DHW TANK 2 209 2 9 9 2, 2,, 00 00 22 2 0 2 CODE Q.TY CODE Q.TY BOILERS 2 2022 Power X 0 DEP R.S.I. (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 20022 Taps for system 2002 Hydraulic header separator for single applic. 9 202 Connection kit for DHW tank return FLUES / AIR INTAKE 2002 Air-intake kit B2 (B) ACCESSORIES FOR DHW TANK (C) - 009 Socket probe for DHW tank SUPPORTS FOR FREE-STANDING APPLICATION 2000 Power X rig 2000 Rear mounting kit for free-standing applic. (D) (A) The configuration illustrated in this page can be applicated also with POWER X 0 R.S.I. (code 20). Inside the Power X boilers range (except for Power X R.S.I.), it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090), or the optional expansion vessel kit of 2 lt. (code 209). (B) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adaptor kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. (C) Inside the R.S.I. models of Power X range, the -ways valve for DHW tank management is already built-in (like in this condiguration). (D) In case you don t need a free-standing application and you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit, code 2000 (ref. ).

FREE-STANDING APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING ONLY 2 209 2, 00 00 22 9 0 9 2, 2 0 2 BOILER CODE Q.TY 20 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 2002 Hydraulic manifold for safety kit (B) 2002 Safety kit (B) - 2009 Gas safety cut-off valve 200kW (B) CODE Q.TY 2002 Hydraulic header separator for single applic. FLUES / AIR INTAKE 2002 Air-intake kit B2 (C) SUPPORTS FOR FREE-STANDING APPLICATION 2000 Power X rig 2000 Rear mounting kit for free-standing applic. (D) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090) or the optional expansion vessel kit of 2 lt. (code 209). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. (D) In case you don t need a free-standing application, but you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit for free-standing installation, code 2000, (ref. ).

FREE-STANDING APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING AND DHW TANK (WITH EXTERNAL -WAY VALVE) 2 209 9 2, 0 2 2, 22 00 00 22 2 0 2 BOILER CODE Q.TY 20 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 2002 Hydraulic manifold for safety kit (B) 2002 Safety kit (B) - 2009 Gas safety cut-off valve 200 kw (B) 2002 Hydraulic header separator for single applic. FLUES / AIR INTAKE CODE Q.TY 2002 Air-intake kit B2 (C) ACCESSORIES FOR DHW TANK 2002 -way valve kit for DHW tank - 009 Socket probe for DHW tank SUPPORTS FOR FREE-STANDING APPLICATION 2000 Power X rig 2000 Rear mounting kit for free-standing applic. (D) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 2090) or the optional expansion vessel kit of 2 lt. (code 209). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 200202) or the concentric flue options Ø0/2 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/2 code 2002029). In both cases, the accessory air-intake kit B2, code 2002, is not necessary. (D) In case you don t need a free-standing application and you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit, code 2000 (ref. ). 9

2_0 ERP EN - 0/ Trading Address: Via Risorgimento, 2/A 2900 LECCO (LC) Italy Tel. +9 0 2 Fax +9 0 22 info@berettaboilers.com www.berettaboilers.com In order to improve its products, Beretta reserves the right to modify the characteristics and information shown in this brochure at any time and without advance warning. This brochure, therefore, cannot be considered as contractually binding on third parties.