Steam Room Installation Manual U880

Similar documents
Sanitary Ware Expert Your best choice!

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

Install manual. Self-clean system. Steam bathroom MODEL : WS-501

Your best choice! STEAM BATHROOM MODEL : WS-902A WS-902B. No advanced advice will be submit before we change our design and size.

Steam Room Installation Manual L52 Series (L528) All set up dimensions are in Millimeters

Your best choice! STEAM BATHROOM MODEL : WS-701. w w w.eaglebath.c o m. No advanced advice will be submit before we change our design and size.

Massage Bathtub. Instructions of installation and usage. Instructions of Installation and Use TLP-632. Cleaning&Maintenance

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

Aquapeutics STEAM ROOM. Installation Manual WG-U6811. Make the most of your shower;make the best for your home!

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

A31. ALEKO Indoor Sauna. s Manual for 3-Person Sauna

A41. ALEKO Indoor Sauna.

Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Instalation and operation

AM 213 Installation Introduction

INSTALLTION MANUAL FOR M-A6012

Oceanic Sauna Heater Manual

24. Exhaust Fan. 2. ½ NPT Brass nut. 1. Brass Elbow. 4. Speaker. 6. Rain Shower head. 5. White LED Light. 16. Flex Drain Assembly

NEPTUNE Steam Room Installation Instructions

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

Packing list. Packing 1. Packing 2. Packing 3. Spare parts list

Installation Manual for M-G014 & M-G015

E2 Series Installation

Murano Shower Cabin Installation Instruction

User manual Whirlpool

Installation and Operation Manual

INSTALLTION MANUAL FOR M-A011

Europa Shower Cabinet

Avenue (HY) Series Installation & Operation Manual

Complete Shower Room Installation Guide and Operation Manual. Models 8727 / 8728

INSTRUCTION FOR ASSEMBLY

Leave the daily challenges behind you and enjoy the perfect end to a day. Give yourself some me-time in the steam.

INSTRUCTION FOR ASSEMBLY. 200x200 v Traditional sauna cabin

INSTRUCTION SHOWER CABIN ILMA 901

AQUAPEUTICS MONACO INSTALLATION MANUAL

Index I. INSTALLATION DIAGRAM... WIRING DIAGRAMS...

INSTRUCTION FOR ASSEMBLY. 150x200 h Traditional sauna cabin

Instruction Manual. Black Radiant Heater HIL Please read these instructions carefully before using your new heater

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

Table of contents. Installation instructions 3 4. Connecting the electric heater to electrical network 4. Control unit 4. Temperature restrictor 4

Radiant Heater. Instruction Manual QH-200 N13275

INSTALLATION MANUAL FOR MODELS: SOVANNA, BREZZA, TERRACINA, VENADO

FAN COILS wall mounted

ELECTRIC WATER HEATER HT382E55

LEVENS STEAM SHOWER ENCLOSURE

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

MANUAL PX4 ENGLISH. Nimbus Combi NIMC-90N NIMC-105N NIMC-120N Super Nimbus Combi ELECTRIC SAUNA HEATER / STEAM GENERATOR

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Filius Control. Installlation and operating instruction MADE IN GERMANY. print no.: en / 06.15

YS-B501 SPA Deluxe Overall Functional Capsule

900 Quadrant Steam Shower Cabin with 6 Body Jets

USER MANUAL OF KL8300 SYSTEM

ARLEY STEAM SHOWER ENCLOSURE

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

FREWIN STEAM SHOWER ENCLOSURE

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

INSTALLATION AND USER MANUAL

INSTALLATION AND OPERATION MANUAL

Mobile Air Conditioner Instruction Manual Model TC-N9KM

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

CONTROLS INSTRUCTIONS MANUAL ENGLISH

AHPO-6/18 GOLD PROOFER OVEN

INSTRUCTION MANUAL EPH-121 CONTENTS

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

Mercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040

STEAM BATHROOM. No advanced advice will be submit before we change our design and size. The pictures may be alittle different from the real products.

Sauna & Steam BEHIND BENCH HEATER. Assembly and operating manual September 2018 PRODUCT IMAGE

Installation Instruction of AM168 TS-series Control panel

Fire and burn safety at home

Installation Instruction of AM124ETL-L TS-series Control panel

Tris. Ideal Standard 3

ARTICA. 8000Btu. Room Air Conditioners Portable Range

PORTABLE AIR CONDITIONER

Sauna & Steam. STEAM GENERATOR (Domestic & Light Commercial) Assembly and operating manual PRODUCT IMAGE

I. U881 Series Structure...1 II. Security Advice...2 III. Technical Parameter...3 IV. Install U881 Sauna Room V. Electricity Supply And Water

Operation Instructions

GDDEM10 DEHUMIDIFIER

Portable Air Conditioner

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

CEILING FAN OWNER'S MANUAL

Original instructions AR

ULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

CONTROLS INSTRUCTIONS MANUAL ENGLISH

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

Sauna & Steam. SAUNA HEATER with OCSB/LB CONTROLLER Assembly and operating manual PRODUCT IMAGE

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 SMALL HEATERS KW. Installation Instructions & User Manual

How to get the most from your Integrated Tumble Dryer HJA 8800

REFRIGERAT A OR USE DF1-15 F ridge


Bath Planning Worksheet

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

READ AND SAVE THESE INSTRUCTIONS

Transcription:

Steam Room Installation Manual U880

Security Advice U880 Structure 9 7 8 4 6 5 6 0 7 4 3 3 0 9 5 8 7 3 4 5 6 8 9 30 Tray Storage Shelf Acupuncture 3 Jet 4 Thermostatic Switch 9 7 Top shower 5 Glass Door 8 Fixed Glass Hinge 9 Pole 6 7 Sauna Stove 0 Sauna Room 8 Cask And Ladle Seak Seat 9 Bench Fixed Glass 0 Backboard Glass Sliding Glass Door Handle 5 Handle Shower 3 Fixed aluminum The Chief Aluminum 4 Pillar 6 Lifting Pole 7 8 Exhaust Fan Top Cover 5 Drainer 6 Control panel 30 Sandglass Timer Thermometer And 3 Hygrometer 4 Expose Proof Light Top Window Sauna Floor.The installation of electrical products, must be installed by A qualified electrician or the professional person who are Assigned by the dealer..the power supply should match the electric parameter of the product, certified leakage protector and overloading protector are requested. Rated voltage 0V40V/50Hz,rated current >5A,and distance among outlets Ё3mm. The creepage switch of the product is as assistant function, so the electrical system should be connected earth credibly. 3.Cutting any wire on the product is strictly prohibited in the process of handling installation. Cant take apart the computer control box, computer control panel and remote control (Anything in computer control box and control panel canўt be remove by user),or we will not take any responsibility for accidents caused by it. 4.Before using every time, check out whether the switch of power is closed and the hot and cool water faucet open. 5.Check whether the creepage protection of the steam room connection is right. Each time to connect the power, the plug of the creepage switch protection should be checked availably. The method is to press the test button, when the indicator lamp turn off, press the reset button, the indicator lamp turn on. If you press the test button and the indicator lamp is still on, or press the reset button and the indicator lamp is still off, the means the creepage protection don't work or creepage accident occur, in this time, you should ask the technician to repair it. 6.Avoiding Organic liquor like acetone, ammonia, petrol and vitriol chemical that will canker acrylic part and plated parts. Advice:.Pay attention to high temperature and prevent burn when using steam shower..person that drunk, hypertensive, asthmatic, heart disease should be careful when using steam shower. 3.Children should be accompanied with adult when using steam shower. 4.After opening sterilization system, should close the door and nobody stand in, 5.Water in massage bathtub do not up to certain level, cant open the generator, it is not allowed. 6.Dont forget to cut water supply and power supply after using the steam shower each time. 7.Insure using electricity safety, electric system should be connected earth credibly. 8.Cant use the product outside. Warning: User must operate strictly according to safety Notice and requirements to installation and usage, otherwise we will not take any responsibility for accidents caused by wrong operation. All right of modifying, change of craft work and technical parameter that manufacturer in this instruction book reserved. Our company reserve all rights to modifying, change of craft work and technical parameter, without further notice, please forgive.

Technical Parameter.Model,Specification Steam Room Installation Function ModelЈ WG-U880 SizeЈ750X80X00 00 0 00 6A waterproof socket Hot water Cold water 0 U80 U80 U830 U840 U850 U860 U870 U880 000x000x50mm 00x880x50mm 950x950x50mm 00x880x50mm 000x000x50mm 040x000x0mm 060x060x80mm 750x80x0mm 6A waterproof socket 350 400 Drainer 400 500 300 80 00 00 750 550 80 The Information of this table are only reference, the company have the right to amend the technique parameter, specification, model, collocate before any advance inform, the detail please inquiry about the dealer..electrical Parameter Three-dimensional installation diagram Plane diagram Power Power Voltage Frequency Steam Generator Sauna stove Circuit Voltage (U880) 0V 50Hz 3000W 3000W W 3.Water Parameter Work Hydraulic Pressure Current Capacity Diameter of drainer Mpa L/min Cold/hot water Drainer 0.-0.4-6 DN 5 DN 40. Water supply: One piece of galvanized tube shall be provided for hot and cold water respectively 000mm high from the ground and the DN5 shut-off valve shall be mounted on the wall: 0.mPa < pressure < 0.4mPa.. Power supply: Steam Generator :3KW/0V/50Hz,Sauna Stove : 3KW/0V / 50Hz single phase and three wire system, BV=3x4mm copper wire insulation,500mm high from the ground, install 6A waterproof socket, connecting the steam generator power line and sauna stove line, the earth terminal should be availability and connect the yellow and blue power line. 3. Water drainage: the floor drainage hole should be > DN50, as the installation draw position to install, can't dead against the drainer mouth of tray or bathtub. 4. The computer system is provided with telephone or CD function, so can install the port of telephone and CD to be near the power socket. 3 4

.Install the tray open the package, move the tray to the usage position, adjust the foot screw, Using the spirit level to measure, adjust the tray to be at a level. Then tweaking the nut tight, every ground foot must close the ground, can't hang in the air. (As PIC 0) Install U880 Sauna Room Spirit Level.Install the first and second wood board Use the wood board Aim at the corresponding holes, then use the screws to lock it tight. (As PIC 0) (PIC 0) 3.Install the third wood board Use the third wood board Aim at the corresponding holes, then use the screws to lock it tight. (As PIC 03) (PIC 06) 4.Install the top wood board Take the top cover to aim at the three wood boards corresponding holes, then use the screws to lock it tight. Finally install the transom(as PIC 04) (PIC 0) 5.Install the cabin of sauna room 0. Install the wood floor, notice the direction. 0. Take the bench into cabin, the use screws to lock it. 03. Install the sauna stove to the appoint position. Notice the power line position. 04. Put the sandglass timer and thermometer and hygrometer to the appoint position, then install the expose proof light, finally put the cask and ladle on the bench. 05. Install the glass door.(as PIC 05) (PIC 07) (PIC 03) (PIC 08) (PIC 04) (PIC09) (PIC 05) 5 6

Sauna Stove Operation ( U880 Sauna Stove) Installation Install the sauna heater onto the wall with the screw provided in the heater, according to the minimum safety distances and volumes indicated in table and Fig,or on the plate of the heater. --The heater can be installed in the wall recess at the minimum height of 900mm. --Do not cover the wall behind the heater with materials like asbestos or plates etc.,because this sort of covering protection could cause too temperature a risk of burn. --Must use qualified materials for the walls and ceiling. Guard Rails Please follow the minimum distances requirements in fig 6 if guardrails are desired around the heater. Connection of Electricity supply cable Only the qualified electrician may conduct the electricity supply connection of the heater's cables talking into consideration of current, valid electrician safety regulations. The connecting cables of the mains supply to the heater must be of REVE rubber insulated cables or at least an equivalent(see the figs).there are conneetion ports in the junction box in sauna heater to connect the indicating lamps outside sauna.(see connection ports of circuit diagram in Fig 7).The section of the connecting cables is the same as one of the heater.the electricity connection box in sauna room must be of a hermetic, splashing proof type with a 7mm diameter condensation hole. The junction box should not be more than 500mm over the floor. Temperature control The thermostat can control the temperature in an idea condition (Fig3). Sauna heater can reach to a preset temperature in 30 to 60 minutes depending on the size of sauna room. Thermostat of three phases electricity can fulfill the preservation of a good even comfort table temperature in sauna room. Time control The time control switch is the main control switch of sauna heater which should be switched off while leaving sauna. Ventilation Good ventilation is a must for the sauna, and correctly installed ventilation creates agreeable bathing conditions, but yet still save energy.for the ventilation to be successful it is important where the ventilation openings are suited, The fresh air intake should be better situated on the wall near the bottom of the sauna heater. The diameter of air inlet must be at least 6 cm. The exhaust opening should be better situated on the wall opposite to and as far as possible from the air intake. The diameter of the exhaust opening must be twice the size of the air intake. The exhaust opening must be situated under the bottom of the upper benches. FigCC A 05 40 05 Sauna Heater D FigD Min 90 Min0 580 Min90 Sauna Stones Since the sauna stones may be dusty, we recommend that they should be rinsed before being loading into the heater container; the largest ones should be loaded at the bottom. Do not load the stones too tight so that air can easily move between the stones whereby a good even cooling can be got for the eating elements. Reload when stones broken or crumbling so that these stones can be got out of the heater before the heating elements get damaged. The diameter of the stones is usually of 3-8cm. Note: The upper screws must be fastened tight, the minimum distances between screw head and wall must be 3mm Sauna Heater C 50 Uperbench D Lowerbench Screw6*6m 0 FigA FigB ~3 370 B 600 50 3.5mm 40 Screw 640(pcs) Screw 66(pcs) 7 8

Fig Time controller 0-80Min Fig4 Temperature sensor 60min Fig6 354SKSM0A Power KW 3.0 3.6 3 3.6 SEPC6 500W, Heating element 0V~40V SEPC63 800W, Fig3 SEPC64 000W SEPC65 670W SEPC63B 3000W Malfunction And Solution Malfunction No power or leakage protect not work Press the Air button and no massage No Steam No massage or hydraulic is lower Steam box rise water Reason Power wire connecting wrong Leakage switch without power water run into steam generator. Leakage occur on power or circuit The pipe connect to the pump is not tight and have leak air Tight the pipe,change the pipe if leak air Heater bar of steam generator broken Steam generator without water water level detector broken Heating protector broken or temperature detector broken Heating protector without connecting Setting temperature is lower than in cabin Setting time is up Function converted without connecting or blocked Water supply pipe is broken or blocked Net of cold/ hot water intake valve is blocked Water intake valve broken Main box have problem The air button in wrong place Adjust the button. Check and replace the heater bar. Check water intake valve, cold/hot water valve Water supply pipe. Check connected circuit and change it. Check and replace reconnect and replace wire Increase setting temperature Adjust setting Connect it or repair it Check and clean it Clean net and water intake valve Check and replace it. Replace it. Solution Check and connect right then connect power. After water volatilization, then connect power. Test power, circuit, earthing wire to debar Fig5 Min0mm Min50mm Min 50m m ()L ()N N L 0V/30V N L N- Connection ports of live wire Connection ports of neuter wire (3) Connection port of grounding wire OZONE no work Pipe leakage water Light no working No sound from loudspeaker Aluminium door inactive upright Connect is wrong OZONE generator is wrong The main computer box is wrong. The seal is wrong The connection not well The pipe is broken Connection is wrong The light is wrong The translator of voltage is wrong Head of loudspeaker connect wrong Main control box broken Without audio signal Install or adjust wrong Door frame isn't upright Connect the line Replace it Replace the computer box Replace the seal Connect again with Glue Replace it Connect the line again Replace the light Replace it Repair it. Replace it. Check connecting. Adjust door block Adjust the shape of door frame and make it 9 0