NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

Similar documents
NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

PMC-M WALL-HUNG GAS CONDENSING BOILERS

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

MPX 24/28 MI Compact MPX 28/33 MI Compact CONDITIONS OF USE HOMOLOGATION. B 23 - C 13x - C 33x - C 53x - C 93x - C 83x* B 23p - B 33 - C 43x

4FLOOR-STANDING GAS CONDENSING BOILERS

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

PRODUCT CATALOGUE

8FUEL OIL CONDENSING BOILERS

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS

ADVANCE EASYLIFE PROJECT

WHE 2.24 / WHE 2.24 FF

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

1 VICTRIX ZEUS Superior kw I features

Ciao Green Condensing Wall-Hung Boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

VICTRIX Superior kw Export VICTRIX Superior kw X Export

SPECIFICATIONS - NIKE

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Exclusive Green E Condensing Wall-Hung Boilers

Range GT GTU C GT 220

Power X High Power Condensing Wall-Hung Boilers

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

Power X High Power Condensing Wall-Hung Boilers

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

Wood-burning boiler CBB. User Guide E

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

Modulens G >> >> >> Condensing in excellence mode

Condensing, pre-mixed, wall-hung gas boilers with water tank

DTG Eco / V130

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

C Tahiti. condensing

ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

INNOVENS MCA ADVANCE WALL-HUNG GAS CONDENSING BOILERS. Conditions of use Boiler Max. operating pressure: 3 bar Max. operating temperature: 90 C WITH

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

white blue cobalt bordeaux light oak (rovere)

ALEZIO EVOLUTION EASYLIFE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Flue gas condensation...

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

INDEPENDENT DOMESTIC CALORIFIERS

ACCUMULATION OF EUROPEAN CLASS

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI

BSC...E - BSP...E - BESC...E

<< >> Condensing technology at the service of oil. Controlling energy to save money

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Remeha. Fuel oil/gas boilers P 420. Installation and Service Manual

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

v SELECTION GUIDELINES

Oil-fired condensing boiler GTU C 330. User Guide B

HT V2 HT Split

Hoval TopGas (12, 16, 22)

Mynute Green Condensing Wall-Hung Boilers

Seradens Super Seradens Super Plus

ENERGY TOP. Condensing boiler solutions

2530C / 3035C / 3540C. Condensing ErP Boilers. Enerwa EnerwaPlus

Sirius FS. Working towards a cleaner future

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

C 330 ECO - C 630 ECO

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

RinNOVA. User manual and installation instructions

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Remeha. Fuel oil/gas boilers P 320. Installation and Service Manual

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

Rinnova Cond X. User manual and installation instructions

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Sirius WH. Working towards a cleaner future

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

WOLF GAS CONDENSING BOILERS COMFORTLINE

Domestic hot water tank SR130. Installation, User and Service Manual

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

BORA BORA. BORA gas: the best suns THE MODELS BORA GAS ALL INNOVATION STRENGTHS

FCX FUEL OIL CONDENSING BOILER RANGE

Transcription:

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or 13 litres EMC-M MI: from 6.1 to 35.7 kw, for heating and instant domestic hot water production with output up to 37.8 kw in DHW mode EMC-M EMC-M MI EMC-M /BS 8 EMC-M /BS 13 EMC-M : for heating only EMC-M MI or EMC-M /BS Heating and domestic hot water by integrated, independent calorifier or micro-accumulated Very compact boiler in an innovative design: 368 x 589 x 36 mm and extremely light. - Boiler fully equipped: delivered with its complete mounting frame; control panel with very easy to use essential functions that can be completed with various options enabling much broader installation parameters such as: modulating room temperature thermostats, service tool. - Equally suited to new installations and the replacement market. - Various air/flue gas connection configurations are possible: we offer solutions for connection by horizontal or vertical forced flue, to a chimney, in twin pipe or to a shared flue system. Condensing All natural gases Propane CE identification No.: 63CM319 Conditions of use Boiler: Max. operating pressure: 3 bar Max. operating temperature: 9 C Safety thermostat: 11 C Power supply: 3 V/5 Hz Protection index: IPXD Domestic hot water: Max. operating pressure: 1 bar Homologation B 3 - B 3P - B 33 - C 13x - C 33x - C 93x - C 53 - C 3x - C 83x Gas category Fitted and preset to operate on natural gases. Adaptable to propane. NOx classification: 5 EASYLIFE

PRESENTATION EMC-M and EMC-M MI boilers are delivered fully assembled and factory tested. They come ready to operate on natural gas H; adaptable to propane thank service tool or modulating room thermostat (option). EMC-M boilers are factory fitted with a heating/dhw reversal valve for connection to an independent hot water calorifier: types of optional DHW calorifiers are available: - 8 litres BMR 8, calorifier to be juxtaposed to the right or the left of the boiler: version EMC-M /BS 8, - 13 litres SR 13 calorifier to be placed on the floor under the boiler: version EMC-M /BS 13. EMC-M MI are mixed boilers and produce large quantities of domestic hot water (HHH classification according to the standard EN 133) thanks to an oversized steel plate exchanger and very reactive electronics. High levels of performance - Efficiency at 3% at 5/3 C up to 19,%. - Performance class HHHH CE. - NOx < 6 mg/kwh. - NOx classification: 5 according to pr EN 83. - Low noise level. Strong points - Wall-hung gas condensing boiler, fully preset. - Boiler of innovative design, very compact: 368 x 589 x 36 mm, extremely light: 5 kg, - Compact exchanger, molded cast alloy aluminium/ silicium high efficiency. - Air/gas module with gas burner, modulating from to 1% for a perfect adaptation of boiler output to actual needs, with non return valve to run with pressurised evacuation system, the central unit, the venturi, the fan with air intake silencer and the gas supply pipe. - Hydraulic module integrating the modulating heating pump with high efficiency index EEI <,3, the heating/dhw reversal valve, stainless steel plate exchanger for instant domestic hot water production by EMC-M MI, the 3 bar heating safety valve, the flow limiter, the flow detector for EMC-M MI - 8 litre expansion vessel integrated in the support frame, - Mounting frame with prefitted water and gas valves, disconnector (outlet and return valves, and disconnector in composite materiel), mechanical manometer, flow collector and connecting pipes kit. - Removable control panel, located under the boiler, can be deported to the wall, connected to the central unit by BUS. Easy to use, it allows a basic setting via buttons heating and DHW temperatures. Other parameters can be set through modulating room thermostats and service tool, see page 6. - Various horizontal or vertical air/flue gas connections (homologation C 13x and C 33x ), twin pipe adapter (homologation C 53 ), or shared flue (homologation C 3x ) are available as options, see page 1. MODELS AVAILABLE Model Boiler Calorifier HR 56 Boiler/ Calorifier connection kit DHW sensor Output (kw) (heating mode) at 5/3 C at 8/6 C Output (kw) (DHW mode) NANEO_Q5 EMC-M For heating only - - - 6.1 -.8 5.5-3. - NANEO_Q3 EMC-M /BS 8 For heating and DWH by 8 litres calorifier to be placed at the right or at left of the boiler HR 56 EE 53 HR 93 AD 6 + + + 6.1 -.8 5.5-3. 5.5 -.6 NANEO_Q33 EMC-M /BS 13 For heating and DWH by 13 litres calorifier to be placed under the boiler HR 56 EE HR 9 AD 6 + + + 6.1 -.8 5.5-3. 5.5 -.5 NANEO_Q5 EMC-M /8 MI EMC-M 3/35 MI EMC-M 3/39 MI For heating and instant domestic hot water production HR 57 HR 58 HR 59 - - - 6.1 -.8 8.5-31. 8.5-35.7 5.5-3. 7.7-9. 7.7-33.8 5.5-7.5 7.7-33.9 7.7-37.8

νεργεια A B C D E F G a e y TECHNICAL SPECIFICATIONS Description EMC-M MI Delivered mounting frame Flue gas evacuation Air vent Ignition and ionisation electrodes Exchanger in cast aluminium/ silicium alloy with complete premixing stainless steel burner, modulating from to 1% output Mounting frame with integrated expansion tank 3 bar heating safety valve Plate exchanger with large exchange surface for the production of micro-storage DHW (EMC-M...MI only) Air/gas module Modulating heating pump with high efficiency index EEI <,3 NANEO_Q8B Heating circulator 1 speed Control panel (see page 6) En e r g i A Thermo-manometer Foldable mounting frame Prefitted water and gas valves including the disconnector NANEO_Q1A View of the underneath of the boiler Air/gas module Safety valve run off Gas burner modulating from to 1% output Air/gas unit Fan Connection points for the «water and gas valve» PCB Condensates evacuation siphon Air intake silencer NANEO_Q7 Expansion tank Support frame NANEO_Q3 Gas safety unit Venturi 3

5 1 C 1 1 3 1 bar ON OFF AU T 3 5 1 C 1 1 1 bar ON OFF AU T 5 1 C 1 1 3 1 bar ON OFF AU T TECHNICAL SPECIFICATIONS Main dimensions (in mm and inches) EMC-M EMC-M MI 18 EMC-M /BS 8 36 3 9 3 9 368 368 3 9 51 75 66 55 6 8 55 6 8 6 6 maxi 176,5 51 75 66 68 88 187 7 6 35 5 1 3 5 7 117 18 51 316 NANEO_F1B 6 35 1 5 18 316 3 5 Ø 6 Ø 7 1 11 187 19 1 11 NANEO_F3D EMC-M /BS 13 NANEO_F3D 368 3 9 1 Départ chauffage Ø 18 int. 55 6 8 51 75 66 3 5 6 Arrivée gaz Ø 18 int. Retour chauffage Ø 18 int Tube d evacuation de la soupape de sécurité Ø 15 mm 9 Evacuation des produits de combustion et conduit d' amenée d' air ø 6/1 mm 1 Sortie eau chaude sanitaire Ø R 3/ 11 Entrée eau froide sanitaire Ø R 3/ 6 35 5 1 3 5 18 316 1 11 6 8 11 153 35 91 59 Ø 57 NANEO_FD Heating flow Ø 18 mm interior EMC-M : primary tank outlet Ø 16 mm interior (if exist) EMC-M MI: DHW outlet Ø 16 mm interior Gas inlet Ø 18 mm interior EMC-M : 1 primary Départ chauffage tank return Ø 18 Ø int. 16 mm interior (if exist) EMC-M MI: domestic cold water inlet Ø 16 mm interior 3 Arrivée gaz Ø 18 int. NANEO_FD Heating return Ø 18 mm interior Safety valve outlet pipe Ø 15 mm Condensates drain Ø 5 mm Evacuation of combustion products and air inlet pipe Ø 6/1 mm EMC-M /BS: DHW outlet R 3/ EMC-M /BS: domestic cold water inlet R 3/ 5 6 9 Retour chauffage Ø 18 int Tube d evacuation de la soupape de sécurité Ø 15 mm Evacuation des produits de combustion et conduit d' amenée d' air ø 6/1 mm

TECHNICAL SPECIFICATIONS Technical specifications Boiler Boiler type: condensing Burner: modulating with complete premixing Boiler specifications Energy used: natural gas or propane Combustion evacuation: chimney or sealed Min. flow temperature: 3 C Model EMC-M /BS 8 /BS 13 /8 MI 3/35 MI 3/39 MI Heating Type generator and DHW Heating Heating and DHW with additional storage of production with only < 1 litres integrated in the secondary circuit separate DHW tank Useful output at 5/3 C Pn (heating mode) kw 6.1-.8 6.1-.8 6.1-.8 8.5-31. 8.5-35.7 Nominal output at 8/6 C (DHW mode) kw - - 7.5 33.9 37.8 Efficiency at % outout and C water temperatur 1% Pn at average temp. 7 C % 97.6 97.6 97.6 97. 96.9 1% Pn at return temp. 3 C % 13.3 13.3 13.3 13.3 1. 3% Pn at return temp. 3 C % 19. 19. 19. 18.8 18.8 Nominal water flow at Pn, t = K m3/h 1.3 1.3 1.3 1.5 1.5 Min. - max. useful output at 8/6 C (heating mode) kw 5.5-3. 5.5-3. 5.5-3. 7.7-9. 7.7-33.8 Manometric height available heating circuit at Pn mbar 1 1 3 67 1 Water content l 1. 1. 1.6 1.7 1.7 Gas flow at Pn (15 C, 113 mbar) - natural gas H/L m 3 /h.5/.95.5/.95.98/3.7 3.68/.8.13/.8 - propane m 3 /h.98.98 1.15 1. 1.6 Flue gas temperature at 8/6 C C 78 78 8 8 86 Min. - max. flue gas mass flowrate kg/h 9.-38.7 9.-38.7 9.-5.5 13.1-56.3 13.1-6.9 Flue gas pressure available Pa 8 8 116 15 1 Stand-by losses at t = 3 K W 35 35 35 5 5 Auxiliary electrical power (ex. heating pump) at Pn W 7 61 Electrical power heating pump (1) W Electrical power in stand by W 3 3 3 3 3 Acoustic power level at nominal output db(a) 7. 7. 7. 7. 9.7 Net weight kg 5 75/95 6 9 9 (1) One speed circulating pump Domestic hot water specifications Model EMC-M /BS 8 /BS 13 /8 MI 3/35 MI 3/39 MI DHW calorifier capacity l 7 1.3 - - - Exchanged power kw.6.5 7.5 33.9 37.8 Flow per hour at t = 35 K l/h 55 (1) 56 (1) - - - Flow over 1 min at t = 3 K l/1 min 16 () 1 () - - - Spec. flow at t = 3 K (compliance with EN 133-1) l/min 16. () () 1 17 19 Cooling constant Wh/h.l.K..1.7 - - - DHW losses through the outer casing at t = 5 K W N.C. 73 - - - Auxiliary electrical power in DHW mode W 117 117 117 15 159 (1) Domestic performance at room temp.: C, cold water temp.: 1 C, primary hot water temp.: 8 C. () Domestic performance at room temp.: C, cold water temp.: 1 C, primary hot water temp.: 85 C, storage temp.: 6 C. 5

CONTROL PANEL NANEO control panel The control panel fitted to NANEO boilers is very easy to use. It is detachable: located under the boiler, it can also be mounted on the wall. As standard, it enables basic settings to be made using the buttons to set the heating and DHW temperatures. Two keys Reset and Chimney Sweep with display LED complete the unit. Other parameters can be set using a service tool (such as the setting of the heating gradient, the maximum boiler temperature, etc. see p. 8) or a modulating room temperature thermostat (options below). A control system option according to the room temperature and/ or the outside temperature is also available: see below. NANEO_Q31 DHW temperature setting button Heating temperature setting button Chimney Sweep key with LED status display Reset key with LED status display NANEO control panel options Programmable room thermostat (wire) - Package AD 137 Programmable room thermostat (wireless) - Package AD Non programmable room thermostat - Package AD 1 The programmable thermostats handle the control a receiver box to be affixed to the wall close to the and weekly programming of the heating by boiler. activating the burner in accordance with the various The non-programmable thermostat is used to operating modes: Automatic according to the regulate the room temperature according to the programme, Permanent at a set temperature or instruction given by activating the burner. Holidays. The wireless versions are delivered with AD 1 AD 881Q3 8666Q1A NANEO_Q3A Non programmable modulating room thermostat «OpenTherm» (wire) Package AD 31 This thermostat handles the regulation of the room temperature adapting the boiler power according to the preset temperature. Handles also the regulation of the DHW temperature. It includes adjustment parameters for the NANEO boilers: read out and setting DHW temperature, max. heating temperature., energy counters (number of startings, number of heating pump, DHW or total operating hours, ), service alerts, etc AD 3 AD 33 isense_q3 isense_q Modulating room thermostat Opentherm (wire) - Package AD 3 Modulating room thermostat Opentherm (wireless) - Package AD 33 These thermostats handle the regulation and programming of the heating and of DHW. They include adjustment parameters for the NANEO boiler: heating curve maxi temperature boiler, fan speed, and an energy metering estimate (number of heating pump, DHW or total operating hours). The regulator adapts the power boiler to the needs. 3 modes of operating are possible: AUTOMATIC: according the weekly programming used: for each programmed period, we can indicate the set temperature. PERMANENT: maintains the set temperature chosen for the day, night or antifreeze. VACATION: intended for absences of long duration. Allows to bring in the dates of beginning and end of the vacation as well as the desired temperature. For operation according to the outside temperature, a outside sensor (package FM 6) can be added. The version «wireless» is delivered with a transmitter-receiver to be fixed to the wall near the boiler. 6

CONTROL PANEL NANEO control panel options (continuation) Outside temperature sensor - Package FM 6 The outside sensor can be used alone or in combination with romm thermostat 8575Q3 MCR_Q18 Domestic hot water sensor - Package AD 6 The domestic hot water sensor is used to apply priority regulation to DHW production by an independent tank. CMIX_Q1 Module to control circuits - Package AD 9 Works only in combination with one or two modulating room thermostat «OpenTherm» (AD 33, AD 3), enables to control and modulate a direct circuit and a circuit with mixing valve or circuits with mixing valve. It is delivered with a flow sensor for each circuit, an outside sensor and a supply cable. The boiler / module connection is made with an «OpenTherm» BUS cable. HYDRAULIC ACCESSORIES Below the list of hydraulic connection accessories to be ordered in the following cases: New installation Standard Nota: - For EMC-M boilers, hydraulic connection accessories: mounting frame with water and gas connection pipes are delivered with the boiler Option: Pipe cover: package HR 7 Provides a neat finish underneath the boiler With rising column Package to order: EMC-M and EMC-M MI: Height adjustment frame: Package HR 79 Hydraulic connection pipe for height adjustment frame: Package HR 8 NANEO_Q1 NANEO_Q17 NANEO_Q Replacing an existing boiler ( onli concerns EMC-M MI) Package to order when replace existing boiler Option: Pipe cover: package HR 73 Hydraulic connection pipe (water and gas) to be screwed: Package HX 17 NANEO_Q1 MS_Q7 7

BOILERS OPTIONS BMR 8 HR 93 SR 13 8666Q3 MCR_Q1 HR 9 NANEO_Q36 NANEO_Q37 Calorifier BMR 8 - Package EE 53 Connection kit BMR 8/EMC-M - Package HR 93 Calorifier SR 13 - Package EE Connection kit SR 13/EMC-M - Package HR 9 BMR 8 and SR 13 domestic hot water tanks are high performance tanks. They are protected by a lining in food quality standard high quartz content vitrified enamel and a magnesium anode. The specifications of these tanks in combination with EMC boilers are given on page 5. The boiler/tank connection kits available include rigid and/or flexible connection pipes between the boiler and the tank. NANEO_Q6A NANEO_Q 898Q3 NANEO_Q11 Service tool - Package HR 83 This tool, at the disposal of the installer, is necessary whenever it comes to setting installation parameters different from the factory settings. It can be used, for example, to modify the settings if the gas type is changed or to modify: - The installation s heating gradient; Solar kit - Package ER 17 Enables connection of a solar DHW tank to an EMC-M MI boiler. When domestic hot water is drawn off, the boiler will provide the additional temperature to satisfy the set point. (See example on page 11) Thermostatic mixing valve - Package EC 6 Used to keep the draw-off temperature in the solar tank constant between 3 and 65 C. Mandatory in solar DHW preparation installations Flue gas temperature sensor kit - Package HR 71 Shuts down the boiler when the flue gas temperature exceeds 11 C. - The maximum boiler temperature; - The fan speed; - etc. It can also be used to help with troubleshooting by displaying an error code. νεργεια a En e r g i e y A B C D E F G A 8531Q68+Picto_ENERGIE_A-A NANEO_Q5 NANEO_Q Compact module for 1 direct circuit and 1 circuit with valve - Package EA 15 This module is fully assembled, insulated, tested and fitted with isolating valves with thermometers, a modulating pump with hight efficiency index EEI <.3 and a motorized 3-way valve (valve Cleaning tool boiler body - Package HR 81 Connects to a classic vacuum cleaner and allows an easy boiler body cleaning. Cleaning tool plate exchanger - Package HR 8 For EMC-M MI only. circuit side). It is connected directly under the boiler to the hydraulic connection kit; if a DHW tank is fitted under the boiler, it can also be relocated to the side. HC 33 HC 3 8531Q7 8531Q8A Condensate neutralisation tank - Package HC 33 Wall bracket for neutralisation tank - Package HC 3 Granule refill for neutralisation tank - Package HC 35 The materials used for the condensates flow pipes must be appropriate; otherwise the condensates must be neutralised. An annual check of the neutralisation system and particularly the effectiveness of the granules by measuring the ph is necessary. If need be, the granules must be replaced. 8

BOILERS OPTIONS Air/flue gas connection to boiler NANEO EMC-M The EMC-M... boilers can be connected to: - a horizontal wall terminal PPS Ø 6/1 mm (package DY 871) - configuration C 13x, - a vertical terminal PPS Ø 8/15 mm, black (package DY 83) or red (DY 8) + adapter (package HR 68) - configuration C 33x, DY 871 DY 8 - it is also possible to connect the boiler to a chimney (configuration B 3p or C 93x ), in twin pipe (configuration C 53 ) or to a shared flue system (configuration C 3x ). All these flue systems must be ordered separately. Horizontal wall terminal PPS Ø 6/1 mm with inspection elbow - Package DY 871 Vertical terminal PPS Ø 8/15 mm - Package DY 8 (red) or DY 83 (black) 8 7 5 MCX_F7B MC35E_F51A L 6 DY 78 ou 817 * L NANEO_Q3A Horizontal wall terminal PPS Ø 6/1 mm without elbow - Package DY 9 5 6 7 8 MCX_F8 NANEO_Q1 Connecting kit for shared flue system - Package DY 91 If connected to a collective duct, the adapter Ø 6/1 mm delivered with the boiler should be removed and replaced by package DY 91 presented opposite, which incorporates the adapter Twin pipe adapter - Package HR 7 For connection with separate air and flue gas pipes (C 53). Ø 8/15 mm as standard. To determine the position of the connection to the shared flue system, see diagram on the next page. NANEO_Q8 NANEO_Q9 Adapter low profile for horizontal forced flue - Package HR 67 Allows a height saving of 66 mm. Flue gas adapter Ø 8/15 mm - Package HR 68 Is fitted instead and in the place of the Ø 6/1 mm fitting delivered mounted on the boiler. 9

INFORMATIONS REQUIRED FOR INSTALLATION Statutory instructions on installation and maintenance The installation and maintenance of the appliance in both be carried out by a qualified professional in compliance with the residential buildings and establishments open to the public must statutory texts of the codes of practice in force. Location NANEO condensing boilers must be installed in premises protected from frost, which can also be ventilate, they must in no event be installed above a heat source or a cooking appliance. The IPXD protection index enables them to be installed in kitchens and bathrooms, excluding protection volumes 1 and, however. The wall to which the boiler is secured must be capable of bearing the weight of the boiler when full of water. In order to ensure adequate accessibility around the boiler, particularly if the boiler is installed in a closed casing we recommend that you respect the minimum dimensions given opposite. Ventilation This must comply with prevailing regulations. min.6 5 1 min. 368 5 min. 5 55 NANEO_F9 min. 5 Connection to a shared flue system with kit DY 91 S 1 + S : - 6 cm (in configuration B 3P ) - 15 cm (in configuration C 13x, C 33x, C 93x, C 53 ) 18 NANEO_F1A In order to avoid damage to boilers, it is necessary to prevent the contamination of combustion air by chloride and/or fluoride compounds, which are particularly corrosive. These compounds are present, for example, in aerosol spray cans, paints, solvents, cleaning products, washing powders/ liquids, detergents, glues, snow clearing salts, etc. It is therefore necessary: - To avoid sucking in air discharged from premises using such products: hairdressers, dry cleaners, industrial premises (solvents), premises containing refrigeration systems (risk of leaking refrigeration fluid), etc. - To avoid the storage of such products close to boilers. Please note that, if the boiler and/or its peripherals become corroded by chloride and/or fluoride compounds, our contractual warranty cannot be invoked. Gas connection Comply with prevailing national or even local instructions and regulations. In all cases, a sectional valve is fitted as close as possible to the boiler. This valve is delivered prefitted to the hydraulic connection plate delivered with NANEO boilers. A gas filter must be fitted to the boiler inlet. Electrical connection This must comply with the prevailing standard. The boiler must be powered by an electrical circuit comprising a omnipole switch with an opening distance > 3 mm. Protect the connection to the mains with a 6 A fuse. Gas supply pressure: - mbar on natural gas H, 5 mbar on natural gas L, - 37 on propane. Notes: - The sensor cables must be separated from the 3 V circuits by at least 1 cm. - In order to protect the pump antifreeze and cleaning functions, we recommend not switching off the boiler at the mains switch. 1

INFORMATIONS REQUIRED FOR INSTALLATION Hydraulic connections Important: The principle of a condensing boiler is to recycle the energy contained in the water vapour in the combustion gases (latent vaporisation heat). Consequently, to achieve an annual operating efficiency in the order of 19%, it is necessary to Connection to the heating circuit NANEO boilers must only be used in closed circuit heating installations. The central heating systems must be cleaned to eliminate the debris (copper, strands, brazing flux) linked to the installation of the system and deposits that can cause malfunctions (noise in the system, chemical reaction between metals). More particularly, if fitting a boiler to an existing installation, it is strongly recommended that you clear sludge out of the system before installing the new boiler. size the heating surfaces in such a way as to obtain low return temperatures, below the dew point (e.g. underfloor heating, low temperature radiators, etc.) during the entire heating period. Furthermore, it is important to protect central heating installations against the risk of corrosion, scaling and microbiological growth by using a corrosion inhibitor adapted to all types of systems (steel, cast iron radiators, heated floor, PER). The water treatment products used must comply with regulations. Manometric height of the heating circulating pump type WILO YONOS PARA RS 15/6 fitted to NANEO boilers EMC-M EMC-M /8 PMC-M MI /8 MI, EMC-M/8 MI Manometric height in mbar 6 5 3 1 1 15 kw kw Manometric height in mbar 7 6 5 kw 3 3 kw 3 1 6 8 1 1 1 16 65 13 Flow rate in l/h 6 8 1 86 13 1 1 16 Flow rate in l/h EMC-M 3/35 MI and 3/39 MI Manometric height in mbar 7 6 5 3 1 39 67 1 6 8 5 kw 3 kw 35 kw 1 1 1 16 11 15 15 Flow rate in l/h Condensates discharge The siphon provided must be connected to the waste water discharge system. The connection must be removable and the flow of condensates visible. The connections and pipes must be in corrosion-resistant material. An optional condensates neutralisation system is available (package HC 33 see page 8). NANEO_F6A 11

1 5 1 C 1 bar 3 1 5 1 C 1 bar 3 1 1 ON OFF AU T ON OFF AU T EXAMPLES OF INSTALLATIONS Examples of installations The examples presented below cannot cover the full range of installation scenarios which may be encountered. Their purpose is to draw the attention to the basic rules to be followed. A certain number of control and safety devices (some of which are already integrated as standard in NANEO boilers) are represented but it is ultimately up to installers, experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it is necessary to abide by the codes of practice and prevailing regulations. EMC-M MI with 1 direct underfloor heating circuit and DHW production, controlled by 1 wireless modulating thermostat Opentherm + outside temperature sensor 1 Thermostat d ambiance modulant sans fil 13.. c FM6 AD 33 65 3V 5Hz 7 8 3 9 9 68 NANEO_F11B NANEO_F11B EMC-M /BS 8 with 1 direct circuit + DHW production circuit, controlled by a programmable room thermostat (wire) AD 137 9 3V 5Hz 33 51 8 3 9 7 External clock 8 3V 5Hz 6 7 8 9 9 3 68 NANEO_F1C Legend: see next page 1

5 1 C 1 1 3 1 bar 5 1 C 1 1 3 1 bar ON OFF AU T ON OFF AU T EXAMPLES OF INSTALLATIONS EMC-M MI with 1 underfloor circuit and 1 direct circuit and DWH production, controlled by modulating thermostat «OpenTherm» + module to control circuits AD9 1 BUS 3V 5Hz AD33 AD33 13.. c 13.. c 51 EA15 3 6 7 7 65 3 8 3 9 9 1 7 11b 68 9 9 9 9 NANEO_F16C EMC-M MI with 1 direct circuit controlled by 1 modulating thermostat «OpenTherm». DWH produced by a solar calorifier with solar kit (package ER 17) 131 11a EMC-M..MI 19 AD3 13.. c 51 3V 5Hz ER17 7 6 3 68 ER UNO BESL NANEO_F3 Legend 1 Heating outlet Heating return 3 Safety valve 3 bar 8 Manual air vent 9 Isolation valve 1 Outside sensor 7 Non-return valve 8 Domestic cold water inlet 9 Pressure reducer 3 Sealed safety device calibrated to 7 bars (mandatory, in compliance with safety directives) 3 (Optional) DHW loop pump 33 DHW temperature sensor 65 C limiter thermostat with manual reset for underfloor heating 51 Thermostat valve NANEO_F3 6 Radiator circuit (gentle heat radiators, for example) 65 Low temperature circuit (underfloor heating, for example) 68 Condensates neutralisation system 11a Collector sensor 19 Duo-Tube 131 Collector field 13

INFORMATIONS REQUIRED FOR INSTALLATION Air/flue gas connection For the use of the air/flue gas connection pipes and the rules on installation, see details of the various configurations in the current product catalogue. 1 Configuration C 13x : Air/flue gas connection by means of concentric pipes to a horizontal terminal (so-called forced flue) Lmax = L1+L L1 Lmax C 13x L L Lmax C 33x Lmax C 3x 1 C 3x C 33x Lmax Lmax Lmax Configuration C 33x : Air/flue gas connection by means of concentric pipes to a vertical terminal (roof outlet) or 3 Configuration C 93x : Air/flue gas connection using concentric pipes in the boiler room and single pipes in the chimney (combustive air with counter current in the chimney) or Air/flue gas connection using concentric pipes in the boiler room and single flex pipes in the chimney (combustive air with counter current in the chimney) L1 Lmax = L1+L 1 C 53 1m max B 3P 5 6 1 3 1 C 3x C 93x 1m max 1m max Lmax C 93x C 33x MCR_F11C 5 Configuration C 53 : Separate air and flue gas connection using a twin pipe adapter and single pipes (combustive air taken from outside) 6 Configuration B 3P : Connection to a chimney (combustive air taken from the boiler room) Configuration C 3X : Connection to a collective shared flue system Table of maximum air/flue gas pipe lengths admissible according to boiler type Type of air/flue gas connection MCR_F11C Lmax of the connecting pipes in m NANEO EMC-M /8 MI 3/35 MI 3/39 MI Concentric pipes connected to a horizontal terminal (PPS) C 13x Ø 6/1 mm 7 7 3 3 Ø 8/15 mm 1.5 5.5 11.5 9.5 Concentric pipes connected to a vertical terminal (PPS) C 33x Ø 8/15 mm 19.5 13.5 11.5 Pipes - concentric in the boiler room, - single in the chimney (combustive air with counter current) (PPS) Pipes - concentric in the boiler room, - flex in the chimney (combustive air with counter current) (PPS) Twin pipe adapter and separate single air/flue gas pipes (combustive air taken from outside) (Alu) C 93x C 93x C 53 Ø 8/15 mm Ø 8 mm Ø 8/15 mm Ø 8 mm Ø 6/1 mm to x 8 mm 18 3 19 17 5 15 13 1.5 18 In the chimney (rigid or flex) (combustive air taken from the premises) (PPS) B 3P Ø 8 mm (flex) 39 (1) (1) 1 18 Ø 8 mm (rigid) 33 9 Shared flue system for sealed boiler C 3x To size such a system, contact the supplier of the shared flue system duct (1) : Max. height in the flue pipe (configuration B 3P ) from the support elbow to the outlet mustn t exceed 5 m for flex PPS. In case of higher lengths, holding collars must be added by slices of 5 or 3 m. 1

DESCRIPTION NANEO EMC-M... Wall-hung gas condensing boiler for connection to a chimney or a forced flue Brand: De Dietrich Classification: HHHH according to the european efficiency directive, NOx classification: 5 Model: - EMC-M for heating only - EMC-M /BS 8 or BS 13 for heating and domestic hot water preparation by associated DHW tank - EMC-M /8-3/35-3/39 MI: for heating and instant domestic hot water production Homologation: B 3 -B 3P -B 33 C 13x -C 33x -C 93x -C 53 -C 3x -C 83x Protection index: IPXD Power supply: 3 V/5 Hz Gas category: all natural gases, propane Useful output in heating mode at 5/3 C: kw Nominal output in DHW mode at 8/6 C: - EMC-M /BS : kw - EMC-M /8 MI: 7.5 kw - EMC-M 3/35 MI: 33.9 kw - EMC-M 3/39 MI: 37.8 kw Specific flow in DHW mode: - EMC-M /8 MI: 1 l/min - EMC-M 3/35 MI: 17 l/min - EMC-M 3/39 MI: 19 l/min - EMC-M/BS : l/min Max. operating temperature: 9 C Max. operating pressure: 3 bar Safety thermostat: 11 C Dimensions: 368 x 589 x 36 mm Weight empty: kg descripton Complies with the requirements of European Directives New compact and ultra-responsive exchanger in cast aluminium/ silicium alloy. Stainless steel gas burner with complete premixing, modulating from to 1% output, fitted with a silencer on the air intake Removable control panel located under the boiler can be deported to the wall. As delivered, it can be used to control and regulate a direct circuit and 1 DHW circuit (sensor optional). Boiler delivered with a mounting frame with prefitted water, gas valves, disconnector, manometer, flow collector, 1 modulating heating pump class A, 3 bar safety valve, 8 litres expansion tank, heating/dhw reversal valve, plate exchanger with large exchange surface for the production of DHW (for EMC-M MI only), automatic air vent. EMC-M/BS: with enamelled 8 litre DHW calorifier placed to the right or to the left of the boiler, or 13 litres DHW calorifier placed under the boiler. Boiler/tank connecting pipes and DHW sensor have to be ordered separately. EMC-M MI: the plate exchanger produces large quantities of instant hot water. Model is equipped with a flow limiter. Air/flue gas connection Ø 6/1 mm with measuring point. Control panel options - Domestic hot water sensor - Programmable room thermostat (wire and wireless) - Modulating room thermostat (wire and wireless) - Outside temperature sensor - Domestic hot water sensor. Boiler options - Height adjustment frame, connecting pipe kit for height adjustment frame - Pipe cover, connection pipe kit for replacing an existing boiler - Solar kit - Flue gas temperature sensor, brush cleaning heat exchanger (only for EMC-M MI) - Service tool - Condensate neutralisation tank - Wall bracket for neutralisation tank - Granule refill for neutralisation tank - Twin pipe adapter x Ø 8 mm, flue gas adapter low profile - Horizontal terminal PPS Ø 6/1 mm - Flue gas adapter Ø 8/15 mm - Vertical flue terminal Ø 8/15 mm (black and red) - Calorifier BMR 8 and SR 13, connection kit boiler/calorifier. 15

DE DIETRICH THERMIQUE Simplified Share Company with registered capital of 87 61 d 57, rue de la Gare - F-6758 MERTZWILLER Tel. +33 ()3 88 8 7 - Fax +33 ()3 88 8 7 99 www.dedietrich-heating.com 5/1 39977B 37.555.559 Strasbourg Companies Register Document not contractually binding - Printed in France - OTT Imprimeurs 6731 Wasselonne - 1853