AirGard. Air Flow Monitors

Similar documents
Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

FUME HOOD MONITOR ALNOR AIRGARD 200

CRITICAL ENVIRONMENT MONITOR ALNOR AIRGARD 350 CEM

Model 405 AIRGARD Fume Hood Monitor

AirGard 385 Fume Hood Monitor

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

ALARM FOR SAFETY CABINETS SPECIFICATIONS

Static Pressure Alarm For Hazardous Location Fume Hoods

FUME HOOD MONITOR ALNOR AIRGARD 335

Model # Airflow Monitor Warranty. Installation, Operation, Maintenance Manual. Analog Airfl ow Monitor Model Number #51403

CHEMICAL FUME HOOD PROGRAM

Installation & Calibration Guide

Fume Hood Operating Display Panel

HVAC Controls Laboratory. Model EVERWATCH Face Velocity Monitor. Operation and Service Manual. P/N , Revision E October 2002

Biological Safety Cabinets or Fume Hoods Which one to use?

RPM1600 Series Room Pressure Monitors

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Carbon Monoxide Transmitter

Oxygen (O2) Single-Point Gas Detection System

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

GLD-30 Gas Leak Detector

MD and Its Impact on Lab Facilities

Ammonia Leak Detector Manual

Fume Hood Safety TYPES OF FUME HOODS

Critical Environments. Model FHC50/FHM10. Fume Hood Controller/Monitor. Operation and Service Manual. P/N , Revision B October 2010

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Appendix A.4.1. Safe Fume Hood User Guide

EVERWATCH FACE VELOCITY MONITOR MODEL 8610

PRESSURA ROOM PRESSURE MONITOR MODELS 8630-SM 8630-PM

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

Controllers. Instruction Manual WARNING

Analog Room Pressure Monitor RPC Series

Instruction Manual WARNING

Contamination Control for Electronic and Semiconductor Applications

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Lab Design shall comply with the UC Lab Safety Design Manual located at: LABORATORY FUME HOODS

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR DEATH.

LABORATORY DESIGN HANDBOOK

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

L a b o r a t o r y E q u i p m e n t C a t a l o g

PolyGard 2-channel Gas Controller MGC-03

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Multi-Gas-Controller MGC2

PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Microbiological Safety Cabinets

Section 1.0: LAB VENTILATION TABLE OF CONTENTS. C. General Ventilation Considerations 3. D. Pressurization 7. E. Supply Air Arrangements 8

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

UC DAVIS Campus Standards & Design Guide DIVISION 11 - EQUIPMENT

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Flopurge TS. Operation Manual

Dependable Solutions for Gas Detection

Innovation in air purification unmatched air quality

LABORATORY EQUIPMENT. A. Section Accessibility for People with Disabilities. B. Section Plumbing Basic Materials and Methods

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Universal Gas Detector

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

UC DAVIS Campus Design Guide DIVISION 11 - EQUIPMENT

Danfoss gas detection units

Dräger PointGard 2100 Detection of toxic gases and vapours

The A-series Eletta Flow Monitor with local indication and analog output

Air Check O 2 Deficiency Monitor 0-25%

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Danfoss gas detection units

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Frequently asked questions: Intelligent Transmitter Series

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

DGC-500 DIGITAL GENSET CONTROLLER

Combustible Gas Detection and Control System

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

PRESSURA ROOM PRESSURE MONITOR MODEL RPM10 AND RPM20

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

LORAIN CSP DC Power System

Oakton TEMP 9500 Advanced Multiparameter Controller

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

TrueAlarm Analog Sensing

ESP TECHNOLOGIES LIMITED

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Transcription:

AirGard Air Flow Monitors

[AirGard Lab Hood Monitors Models 200/405 Model 335 The AirGard Models 200 & 405 are simple, go/no-go lab hood monitors designed to warn users of unsafe conditions. The flush-mount Model 200 has a sleek appearance often preferred on new hoods while the surface-mount Model 405 is easy to install on existing hoods. The AirGard Model 335 lab hood monitor surpasses the protection offered by go/no-go monitors like the Models 200 & 405. It features prominent LEDs to indicate hood status, a digital display of the actual measured face velocity and the ability to warn of unsafe high face velocities, increasing user confidence in lab hoods. AirGard 200 AirGard 405 specifications AirGard 335 AirGard 200/405 AirGard 335 display range n/a 50 250 fpm (0.25 1.27 m/s) alarm range 70 250 fpm (0.35 1.25 m/s) 50 250 fpm (0.25 1.27 m/s) field set-up single low velocity alarm set point 2 point velocity set-up alarm set points low low and high repeatability of ±10% of reading or 10 fpm (0.05 m/s), whichever ±10% of reading or 10 fpm (0.05 m/s), whichever alarm set point is greater is greater alarm delays 10 seconds user configurable through menu relay output 1 2 remote alarm yes yes acknowledge units n/a selectable (English & Metric) display visual jumbo green LED: normal analog bar graph, jumbo LEDs jumbo red LED: alarm red zone: alarm yellow zone: marginal green zone: normal (digital LCD can be enabled) alarm jumbo red LED and audible jumbo red LED and audible indications alarm (85 db @ 4 [10 cm]) alarm (85 db @ 4 [10 cm]) high flow n/a yes alarm disable emergency purge no yes horn silence temporary and permanent temporary and permanent mounting flush (200) or surface (405) flush operating temperature 55 86 F (13 30 C) 55 86 F (13 30 C) storage temperature -40 150 F (-40 65 C) -40 150 F (-40 65 C) power requirement 9V AC 9 30V AC/DC instrument dimensions FRONT FACE PLATE 200: 4.75 x 3.25 x 0.5 in. (12.07 x 8.25 x 1.27 cm) 5.25 x 3.0 x 0.625 in. (13.3 x 7.62 x 1.59 cm) 405: 6.0 x 3.13 x 1.75 in. (15.24 x 7.95 x 4.45 cm) REAR ENCLOSURE 200: 4.5 x 2.5 x 1.38 in. (11.43 x 6.35 x 3.5 cm) 3.0 x 2.0 x 0.5 in. (7.62 x 5.08 x 1.27 cm) agency listings CE CE, UL Specifications are subject to change without notice.

Laboratory chemical hoods are designed to limit exposure to hazardous chemicals during experiments and production by containing and exhausting generated vapors and gases. To do this, hoods exhaust large quantities of laboratory air. Yet, the velocity of air entering the lab hood is only on the order of 1 mph. Industry organizations agree-some method of verifying operation is needed to ensure user safety. Similarly, biological safety cabinets direct air flows to protect the users from whatever agents are held and to protect these agents from contamination. Insufficient airflow can put the safety of workers at risk while tainting experiments. Again, performance must be monitored to maintain protection and to comply with industry standards. But how can you reliably measure these low air velocities? Enter Alnor. The line of AirGard air flow monitors measures parameters of importance, face velocity in fume hoods or downflow/exhaust flow velocity in biological safety cabinets. Should airflows drop to potentially unsafe levels, the AirGard monitors will alert laboratory users so corrective actions can be taken. AirGard 350-CEM AirGard 315-BSC Designed to meet intent of: ANSI Z9.5-2003 3.3.3 Flow-Measuring Device for Laboratory Chemical Hoods All hoods shall be equipped with a flow indicator, flow alarm, or face velocity alarm indicator to alert users to improper exhaust flow. NFPA 45-2000 6.8.7 Measuring Device for Hood Airflow 6.8.7.1 A measuring device for hood airflow shall be provided on each laboratory hood. 6.8.7.2 The measuring device for hood airflow shall be a permanently installed device and shall provide constant indication to the hood user of adequate or inadequate hood airflow. SEFA 1.2-2002 4.1.10 All hoods shall have some type of monitor for indicating face velocity or exhaust flow verification... A ribbon taped to the bottom of the sash is not acceptable. 29 CFR 1910.1450 Appendix A-National Research Council Recommendations Concerning Chemical Hygiene in Laboratories C. The Laboratory Facility 4. Ventilaton (b) Hoods...each hood should have a continuous monitoring device to allow convenient confirmation of adequate hood performance before use. NSF49-2002 5.23 Alarms 5.23.3 Type B exhaust alarm...audible and visual alarms shall be required to indicate a 20% loss of exhaust volume within 30 seconds... AirGard Lab Hood Monitors AirGard Air Flow Monitors Please refer to the actual standards for detailed information and to make the best interpretation of each standard.

[AirGard Air Flow Monitors For Bio-Safety Cabinets and other Critical Environments Models 315-BSC The AirGard Model 315-BSC is a simple, go/no-go monitor for critical airflows including the downflow of a bio-safety cabinet. By warning of poor bio-safety cabinet performance, the 315-BSC can increase staff protection while reducing experiment contamination. AirGard 315-BSC Model 350-CEM The AirGard Model 350-CEM goes a step beyond the Model 315-BSC. Its large LED and digital display of measured velocity give unrivaled information to users, making this monitor a powerful diagnostic tool. specifications AirGard 350-CEM AirGard 350-CEM AirGard 315-BSC bar graph display range 25 2,000 fpm (0.13 10.2 m/s) n/a alarm range 25 2,000 fpm (0.13 10.2 m/s) 25 2,000 fpm (0.13 10.2 m/s) alarm delays user configurable through menu 3 seconds relay output NC, NO NC, NO remote alarm acknowledge yes no units selectable (English & Metric) n/a display visual bar graph, red zone alarm, jumbo green LED for normal yellow zone marginal, jumbo yellow LED for warning green zone normal, jumbo LEDs jumbo red LED for alarm (digital LCD can be enabled) alarm jumbo red LED and audible jumbo red LED and audible indications alarm (85 db @ 4 [10 cm]) alarm (85 db @ 4 [10 cm]) high flow alarm disable yes n/a horn silence temporary and permanent temporary and permanent mounting flush or kit flush or kit cable length 10 ft (3 m) 10 ft (3 m) calibration single point field calibration low alarm set point recommended operating temperature 50 95 F (10 35 C) 50 95 F (10 35 C) storage temperature -40 150 F (-40 65 C) -40 150 F (-40 65 C) power requirement 9 30V AC/DC 9 30V AC/DC instrument dimensions FRONT FACE PLATE 5.25" x 3.0" x 0.625" 5.25" x 3.0" x 0.625" 13.3 cm x 7.62 cm x 1.59 cm 13.3 cm x 7.62 cm x 1.59 cm REAR ENCLOSURE 3.0" x 2.0" x 0.5" 3.0" x 2.0" x 0.5" 7.62 cm x 5.08 cm x 1.27 cm 7.62 cm x 5.08 cm x 1.27 cm accuracy ±5% of reading or 5 fpm, ±5% of set point whichever is greater agency listings CE CE Specifications are subject to change without notice.

[AirGard Air Flow Monitors For Hazardous Environment Lab Hoods Model 410-HE The AirGard Model 410-HE lab hood monitor is designed to alert staff of unsafe conditions. The Model 410-HE is constructed of explosion-proof components, minimizing the odds of an incident. AirGard 410 HE specifications AirGard 410-HE Monitor accuracy based on pressure switch specifications: note: operating range alarm range alarm relay output visual indicators operating range: 0.07 to 0.15 inches water approximate dead band at minimum set point 0.04 in. water approximate dead band at maximum set point 0.06 in. water higher range pressure switch available if needed 0.07 to 0.15 inches water 0.07 to 0.15 inches water nominal switching capacity 1A at 30 VDC, 0.5A at 125 VAC; form C relay green LED = airflow OK red LED = low airflow audible indicator minimum audible rating 88db at 10 feet (3.05 m) horn silence mounting cable length calibration operating temperature power requirement agency listings temporary kit installer buys cables of proper length low alarm set point 55 to 86 F (12.8 to 30 C) 120 VAC (±10%), 60 Hz., 0.25 amp maximum UL Specifications are subject to change without notice.

If You Do This... You need our reliable, affordable, easy-to-use tools. Alnor Products/TSI Incorporated 500 Cardigan Road Shoreview, MN 55126 USA E-mail: customerservice@alnor.com Web: www.alnor.com Alnor Direct Sales Lindberghs Gata 9 195 61 Arlanda Stad Sweden Telephone +46 8-595 132 30 Fax +46 8-595 132 39 June 2003 Printed in U.S.A. Part # 2980238 Copyright 2003 TSI Incorporated [TO PLACE AN ORDER, OR FOR MORE INFORMATION CALL ALNOR TOLL-FREE 1.800.424.7427 OR PHONE 651.490.2811 FAX 651.490.3824]