Chattanooga Home Inspector LLC

Similar documents
Home Inspection Standards of Practice

Troy's Home Inspection Services LLC

Inspector Gadget Homes

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Axiom Property Inspections

Inside Out Home Inspections

Extra Mile Inspection, Inc.

Watson Home Inspection Services, LLC.

MAISON INSPECTIONS

Hearth and Homes Inspections, llc

OBSIDIAN HOME INSPECTION (208)

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Excellent Home Inspection Services, LLC

Canadian Property Inspections

Bayshore House Inspections LLC

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

Space Coast Home Inspections LLC

Jeff Brown Inspections

FAIRA TRANSPARENCY REPORTS. November 21, 2016

CHARLESTON ROOTS MANAGEMENT

RW West Consultants. Property Inspection Report

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Cascade Inspection Services, LLC

I. STRUCTURAL SYSTEMS

All In One Home Inspections

MHI Services Inc. Property Inspection Report

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

INSPECTPROS, INC

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Tennessee Valley Property Inspections

Inspection Report 123 My Street Midland, GA

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS. November 21, 2016

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

Priority Home & Commercial Inspections

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

This Report Was Prepared For: Property Address Inspected:

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

SPS Home Inspections, LLC

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

Inspection Report. Darol Tucker. Property Address: 19 Ohio Dr. Little Egg Harbor NJ JLC Home Inspections, llc

Home Inspection Report

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

Inspection Report. Mr. John Sample. Property Address: 123 Pine Street Vancouver BC V3M6C5. Exterior Front of Home. Fairbairn Inspection Services

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

DIAMOND WILLOW HOME SERVICES

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

Patriot Home Inspections

Coast Home Inspection

CMHC HOME MAINTENANCE CHECKLIST

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

Inspection Report. Jane Doe. Property Address: 123 Anywhere Montgomery AL Central Alabama Property Inspections

Home Inspection Report

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

Steve Ramsey Home Inspections

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS st Ave, #605, Seattle, WA June 2 nd, 2017

Final Phase Inspection

The Ultimate Home Inspection Checklist

FAIRA TRANSPARENCY REPORTS. July 6, 2016

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

The Ultimate Home Maintenance Schedule

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

Home Inspection Report

McKinney Inspection Company

fieldwork report contains the Functional

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Transcription:

Cover Page Chattanooga Home Inspector LLC Property Inspection Report 37377 Inspection prepared for: Happy Home Buyer & Sally Sales-a-lot Date of Inspection: 1/1/2015 Time: 2:00 PM Weather: 74 degrees and sunny. Inspector: Malcolm Godwin License # 1222 Chattanooga, TN Phone: 423-284-1510 Email: Malcolm@ChattanoogaHomeInspector.com ChattanoogaHomeInspector.com

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Interior Areas Page 4 Item: C Electrical Outlet near front door is labeled GFCI protected and is not. This outlet is not required to GFCI protected. Recommend removing sticker. Page 5 Item: F Stairs & Handrail Landing going downstairs missing handrail. Consider adding handrail. Exterior Areas Page 30 Item: A Doors Basement door has slight rot around bottom of door. Recommend replacing rotten area. Page 31 Item: B Siding Condition Dryer vent broken. Recommend replacing dryer vent. Page 1 of 36

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific non-code, noncosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. This home inspection will be in accordance with the Standards of Practice promulgated by the commissioner of the state of TN and standards of practice by the International Association of Certified Home Inspectors. The state of TN does not allow home inspectors to address environmental hazards, including: Lead-based paint; Radon; Asbestos; Cockroaches; Rodents; Pesticides; Treated lumber; Fungus; Mercury; Carbon monoxide; other similar environmental hazards: or subterranean systems or system components including: Sewage disposal; Water supply; or Fuel storage or delivery. Inspection Details A Home Inspection is a non-invasive visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to the inspection process. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection and not the prediction of future conditions. A home inspection will not reveal every concern that exists or ever could exist, but only those material defects observed on the day of the inspection. A material defect is a condition with a residential real property or any portion of it that would have a significant adverse impact on the value of the real property or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect. An Inspection report shall describe and identify in written format the inspected systems, structures, and components of the dwelling and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals, but this is not required. A. Attendance B. Home Type C. Occupancy In Attendance: Client present at end of inspection. Home Type: Single Family Home. Attached Garage. Occupancy: Occupied - Furnished. Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual Page 2 of 36

inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. Doors, Windows &Interior The inspector shall inspect: a representative number of doors and windows by opening and closing them; floors, walls and ceilings; stairs, steps, landings, stairways and ramps; railings, guards and handrails; and garage vehicle doors and the operation of garage vehicle door openers, using normal operating controls. Inspector shall describe: a garage vehicle door as manually-operated or installed with a garage door opener. Inspector shall report as in need of correction: improper spacing between intermediate balusters, spindles and rails for steps, stairways, guards and railings; photo-electric safety sensors that did not operate properly; and any window that was obviously fogged or displayed other evidence of broken seals. The inspector is not required to: inspect paint, wallpaper, window treatments or finish treatments, inspect floor coverings or carpeting, inspect central vacuum systems, inspect for safety glazing, inspect security systems or components, evaluate the fastening of islands, countertops, cabinets, sink tops or fixtures, move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the concealed floor structure, move suspended-ceiling tiles, inspect or move any household appliances, inspect or operate equipment housed in the garage, except as otherwise noted, verify or certify the proper operation of any pressure-activated auto-reverse or related safety feature of a garage door, operate or evaluate any security bar release and opening mechanisms, whether interior or exterior, including their compliance with local, state or federal standards, operate any system, appliance or component that requires the use of special keys, codes, combinations or devices, operate or evaluate self-cleaning oven cycles, tilt guards/latches, or signal lights, inspect microwave ovens or test leakage from microwave ovens, operate or examine any sauna, steam-generating equipment, kiln, toaster, ice maker, coffee maker, can opener, bread warmer, blender, instant hot-water dispenser, or other small, ancillary appliances or devices, inspect elevators, inspect remote controls, inspect appliances, inspect items not permanently installed, discover firewall compromises, inspect pools, spas or fountains, determine the adequacy of whirlpool or spa jets, water force, or bubble effects, determine the structural integrity or leakage of pools or spas A. Door Bell Operated normally when tested. B. Ceiling Fans Operated normally when tested, at time of inspection. C. Electrical A representative number of electrical outlets were tested and wiring appears to be correct. Two amber lights on tester indicate correct wiring. Outlet near front door is labeled GFCI protected and is not. This outlet is not required to GFCI protected. Recommend removing sticker. Page 3 of 36

D. Window Condition Page 4 of 36

E. Smoke Detectors F. Stairs & Handrail Operated when tested. Landing going downstairs missing handrail. Consider adding handrail. Bedroom 1 The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. A. Locations Locations: Master bedroom. Page 5 of 36

B. Cover Photo C. Ceiling Fans Operated normally when tested at time of inspection. D. Electrical A representative number of electrical outlets were tested and wiring appears to be correct Two amber lights on tester indicate correct wiring. Page 6 of 36

E. Window Condition A. Locations B. Cover Photo Locations: West bedroom. Bedroom #2 Page 7 of 36

C. Ceiling Fans Operated normally when tested at time of inspection. D. Electrical A representative number of electrical outlets were tested and wiring appears to be correct Two amber lights on tester indicate correct wiring. Page 8 of 36

E. Window Condition A. Locations B. Cover Photo Locations: North bedroom. Bedroom #3 Page 9 of 36

C. Ceiling Fans Operated normally when tested at time of inspection. D. Electrical A representative number of electrical outlets were tested and wiring appears to be correct Two amber lights on tester indicate correct wiring. Page 10 of 36

E. Window Condition Bathroom #1 Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. A. Locations Locations: Master Bathroom. B. Exhaust Fan The bath fan was operated and no issues were found. Page 11 of 36

C. Showers Shower faucet tested, appeared to flow and drain correctly. D. Toilets Operated when tested. No deficiencies noted. E. Sinks Sink operated, tested for flow, drainage, and leaks. Everything appears to function properly. Page 12 of 36

F. Bath Tubs Whirlpool tub observed. Tub was filled to a level above the water jets and operated to check intake and jets. Tub appeared to operate correctly. Access panel is located outside and is nailed shut, therefore motor, electrical, and plumbing lines were not inspected. If a more detailed report is desired, the client is advised to consult a licensed plumber for a complete review. Page 13 of 36

G. GFCI GFCI outlets were tested and appear operational. Page 14 of 36

A. Locations B. Exhaust Fan C. Showers Bathroom #2 Locations: Guest bathroom. The bath fan was operated and no issues were found. Shower faucet tested, appeared to flow and drain correctly. D. Toilets Operated when tested. No deficiencies noted. Page 15 of 36

E. Sinks Sink operated, tested for flow, drainage, and leaks. Everything appears to function properly. F. GFCI GFCI outlets were tested and appear operational. Page 16 of 36

Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. A. Dishwasher Dishwasher was turned on and ran through short cycle, appeared to operate correctly at time of inspection, yet not tested for cleanliness. B. Sinks Sink operated, tested for flow, drainage, and leaks. Everything appears to function properly. Page 17 of 36

C. Garbage Disposal D. Microwave Operated - appeared functional at time of inspection. Microwave was turned on and appeared to operate correctly, yet temperature difference was unable to be measured. E. Cook top condition Electric cook top noted. All heating elements operated when tested. Page 18 of 36

F. Oven & Range Oven: Electric radiant heating coils. G. GFCI GFCI in place and operational. Page 19 of 36

H. Condition Refrigerator was on and appeared in working condition at time of inspection. Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. Heating The inspector shall inspect: the heating system, using normal operating controls. The inspector shall describe: the location of the thermostat for the heating system; the energy source; and the heating method. The inspector shall report as in need of correction: any heating system that did not operate; and if the heating system was deemed inaccessible. The inspector is not required to: inspect or evaluate the interior of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh-air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems, or solar heating systems, inspect fuel tanks or underground or concealed fuel supply systems, determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system, light or ignite pilot flames, activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment, override electronic thermostats, evaluate fuel quality, verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.cooling The inspector shall inspect: the cooling system using normal operating controls. The inspector shall describe: the location of the thermostat for the cooling system; and the cooling method. The inspector shall report as in need of correction: any cooling system that did not operate; and if the Page 20 of 36

cooling system was deemed inaccessible. The inspector is not required to: determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system, inspect portable window units, through-wall units, or electronic air filters, operate equipment or systems if the exterior temperature is below 65 Fahrenheit, or when other circumstances are not conducive to safe operation or may damage the equipment, inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks, examine electrical current, coolant fluids or gases, or coolant leakage. A. Heater Condition Materials: The furnace is located in the garage. Materials: Electric forced hot air. The home has a split system. Heat pump noted. B. AC Compress Condition Compressor Type: Electric Location: The compressor is located on the exterior grounds. C. Air Supply AC temperature that was taken at the return register was measured at 68 degrees. The average temperature taken at various supply vents was measured at 44 degrees. This change in temperature indicates AC system is working efficiently at the time of inspection. Heat temperature that was taken at the return register was measured at 71 degrees. The average temperature taken at various supply vents was measured at 128 degrees. This change in temperature indicates heating system is working efficiently at the time of inspection. Page 21 of 36

D. Thermostats Thermostat located above return register in hallway. Water Heater Plumbing The inspector shall inspect: the main water supply shut-off valve; the main fuel supply shut-off valve; the water heating equipment, including the energy source, venting connections, temperature/pressure-relief (TPR) valves, Watts 210 valves, and seismic bracing; interior water supply, including all fixtures and faucets, by running the water; all toilets for proper operation by flushing; all sinks, tubs and showers for functional drainage; the drain, waste and vent system; and drainage sump pumps with accessible floats. The inspector shall describe: whether the water supply is public or private based upon observed evidence; the location of the main water supply shut-off valve; the location of the main fuel supply shut-off valve; the location of any observed fuel-storage system; and the capacity of the water heating equipment, if labeled. The inspector shall report as in need of correction: deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; deficiencies in the installation of hot and cold water faucets; mechanical drain stops that were missing or did not operate if installed in sinks, lavatories and tubs; and toilets that were damaged, had loose connections to the floor, were leaking, or had tank components that did not operate. The inspector is not required to: light or ignite pilot flames, measure the capacity, temperature, age, life expectancy or adequacy of the water heater, inspect the interior of flues or chimneys, combustion air systems, water softener or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems, or fire sprinkler systems, determine the exact flow rate, volume, pressure, temperature or adequacy of the water supply, determine the water quality, potability or reliability of the water supply or source, open sealed plumbing access panels, inspect clothes washing machines or their connections, operate any valve, test shower pans, tub and shower surrounds or enclosures for leakage or functional overflow protection, evaluate the compliance with conservation, energy or building standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping, determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices, determine whether there are sufficient cleanouts for effective cleaning of drains, evaluate fuel storage tanks or supply systems, inspect wastewater treatment systems, inspect water treatment systems or water filters, inspect water storage tanks, pressure pumps, or bladder tanks, evaluate wait-time to obtain hot water at fixtures, or perform testing of any kind to water heater elements, evaluate or determine the adequacy of combustion air, test, operate, open or close: safety controls, manual stop valves, temperature/pressure-relief valves, control valves, or check valves, examine ancillary or auxiliary systems or components, such as, but not limited to, those related to solar water heating and hot water circulation, determine the existence or condition of polybutylene plumbing. Page 22 of 36

A. Water Heater Condition Heater Type: Electric Location: The heater is located in the basement. B. TPRV There is no TPR valve present on this water heater. This is a serious safety concern and needs to be corrected at once. We recommend contacting a licensed plumber to install a proper valve. C. Number Of Gallons 50 gallons A. Floor Condition Garage Materials: Bare concrete floors noted. Page 23 of 36

B. GFCI GFCI in place and operational. C. Garage Door Condition Materials: One 16' double car steel door noted. Page 24 of 36

D. Garage Opener Status Chain drive opener noted. E. Garage Door's Reverse Status Eye beam system present and operating. Electrical Electrical The inspector shall inspect: the service drop; the overhead service conductors and attachment point; the service head, gooseneck and drip loops; the service mast, service conduit and raceway; the electric meter and base; service-entrance conductors; the main service disconnect; panelboards and over-current protection devices (circuit breakers and fuses); service grounding and bonding; a representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where possible; all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using a GFCI tester, where possible; and smoke and carbon-monoxide detectors. The inspector shall describe: the main service disconnect's amperage rating, if labeled; and the type of wiring observed. The inspector shall report as in need of correction: deficiencies in the integrity of the service-entrance conductors insulation, drip loop, and vertical clearances from grade and roofs; any unused circuit-breaker panel opening that was not filled; the presence of solid conductor aluminum branch-circuit wiring, if readily visible; any tested receptacle in which power was not present, polarity was incorrect, the cover was not in place, the GFCI devices were not properly installed or did not operate properly, evidence of arcing or excessive heat, and where the receptacle was not grounded or was not secured to the wall; and the absence of smoke detectors. The inspector is not required to: insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or electrical fixtures, operate electrical systems that are shut down, remove panelboard cabinet covers or dead fronts, operate or re-set over-current protection devices or overload devices, operate smoke or carbon-monoxide detectors, measure or determine the amperage or voltage of the main service equipment, if not visibly labeled, inspect the fire and alarm system or components, inspect the ancillary wiring or remote-control devices, activate any electrical systems or branch circuits that are not energized, inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any time-controlled devices, verify the service ground, inspect private or emergency electrical supply sources, including, but not limited to: generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility, inspect spark or lightning arrestors, inspect or test de-icing equipment, conduct voltage-drop calculations, determine the accuracy of labeling, inspect exterior lighting. A. Electrical Panel Location: Panel box located in garage. Page 25 of 36

B. Main Amp Breaker Service disconnect breaker located outside near meter. 200 amp C. Cable Feeds There is an underground service lateral noted. Aluminum service wires, and copper branch wires noted. Page 26 of 36

Roof Roof The inspector shall inspect from ground level or the eaves: the roof-covering materials; the gutters; the downspouts; the vents, flashing, skylights, chimney, and other roof penetrations; and the general structure of the roof from the readily accessible panels, doors or stairs. The inspector shall describe: the type of roof-covering materials. The inspector shall report as in need of correction: observed indications of active roof leaks. The inspector is not required to: walk on any roof surface, predict the service life expectancy, inspect underground downspout diverter drainage pipes, remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces, move insulation, inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments, walk on any roof areas that appear, in the opinion of the inspector, to be unsafe, walk on any roof areas if it might, in the opinion of the inspector, cause damage, perform a water test, warrant or certify the roof, confirm proper fastening or installation of any roof-covering material. A. Roof Condition Materials: Inspected from ladder at eaves. Materials: Asphalt shingles noted. Page 27 of 36

B. Gutter No major system safety or function concerns noted at time of inspection. Page 28 of 36

Attic Attic, Insulation &Ventilation. The inspector shall inspect: insulation in unfinished spaces, including attics, crawlspaces and foundation areas; ventilation of unfinished spaces, including attics, crawlspaces and foundation areas; and mechanical exhaust systems in the kitchen, bathrooms and laundry area. The inspector shall describe: the type of insulation observed; and the approximate average depth of insulation observed at the unfinished attic floor area or roof structure. The inspector shall report as in need of correction: the general absence of insulation or ventilation in unfinished spaces. The inspector is not required to:vcenter the attic or any unfinished spaces that are not readily accessible, or where entry could cause damage or, in the inspector's opinion, pose a safety hazard, move, touch or disturb insulation, move, touch or disturb vapor retarders, break or otherwise damage the surface finish or weather seal on or around access panels or covers, identify the composition or R-value of insulation material, activate thermostatically operated fans, determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring, determine the adequacy of ventilation. A. Access Pull Down Ladder located in hallway and laundry room. Inspected from attic opening. Page 29 of 36

B. Ventilation Under eave soffit inlet vents noted. Ridge exhaust venting noted. Gable louver vents noted. C. Insulation Condition Materials: Blown in fiberglass insulation noted. Depth: Average approximate depth of insulation is 13 inches. A. Doors Exterior Areas Basement door has slight rot around bottom of door. Recommend replacing rotten area. Page 30 of 36

B. Siding Condition Materials: Vinyl siding noted. Brick veneer noted. Dryer vent broken. Recommend replacing dryer vent. A. Flooring Foundation Basement foundation noted. Concrete block foundation noted. Page 31 of 36

Grounds A. Driveway and Walkway Condition Materials: Concrete driveway noted. B. Grading C. GFCI No major system safety or function concerns noted at time of inspection. GFCI detected and tested, proper covers were also in place for outdoor outlet use. Page 32 of 36

D. Plumbing Materials: Aquapex piping noted. Public water supply meter located at end of driveway near street. Septic system not visible, not inspected. Page 33 of 36

E. Exterior Faucet Condition Location: Front of structure. South side of house. F. Patio and Porch Deck Page 34 of 36

G. Stairs & Handrail Appeared functional at time of inspection. Basement/Crawlspace Basement, Foundation, Crawlspace &Structure. The inspector shall inspect: the foundation; the basement; the crawlspace; and structural components. The inspector shall describe: the type of foundation; and the location of the access to the under-floor space. The inspector shall report as in need of correction: observed indications of wood in contact with or near soil; observed indications of active water penetration; observed indications of possible foundation movement, such as sheetrock cracks, brick cracks, out-of-square door frames, and unlevel floors; and any observed cutting, notching and boring of framing members that may, in the inspector's opinion, present a structural or safety concern. The inspector is not required to: enter any crawlspace that is not readily accessible or where entry could cause damage or pose a hazard to the inspector, move stored items or debris, operate sump pumps with inaccessible floats, identify the size, spacing, span or location or determine the adequacy of foundation bolting, bracing, joists, joist spans or support systems, provide any engineering or architectural service, report on the adequacy of any structural system or component. A. Floor Page 35 of 36

Chattanooga Home Inspector LLC 123 Home Inspection Way., Chattanooga, TN B. Insulation No insulation found for flooring. Page 36 of 36