Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Similar documents
MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

FAN UNIT FH4A Sizes 001 thru 004

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

FCM4X. Product Specifications

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

Installation Instructions

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

FXM4X. Product Specifications FAN COILS FXM4X

FEM4X. Product Specifications FAN COILS /14/15

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Dimensions H x W x D in. (mm)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

WAHL A Product Specifications

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

REM4P, REM4X. Product Specifications

PAJ3. Product Specifications

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Installation Instructions

Installation Instructions

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Installation Instructions

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

PAR5. Product Specifications

Installation Instructions

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Model 655A Sizes

Product Data. HUM Humidifiers

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

HIGH EFFICIENCY AIR HANDLER

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

WJH4 Product Specifications

Table of Contents. Page 2

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Models 566D 569C,576B with 524A 6to30Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

R4H4. Product Specifications

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

R4H4. Product Specifications

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

Product Data MECH. Mechanical Filter Air Cleaner

WPH4 Product Specifications

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Ruud Standard Efficiency Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Rheem High Efficiency Air Handler

Product Data. Fig. 1 - Unit 50EZ -A

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

PHD3. Product Specifications

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Rheem Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Transcription:

Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can deliver high-tech performance, application versatility, easy installation, and high efficiency. The FK4C achieves all this by taking full advantage of its programmable integrated controls and motor (ICM2). This versatile motor is completely static independent, meaning the motor will deliver the selected CFM regardless of the duct system, making it the perfect choice for both high and low static applications. Other features homeowners will appreciate are the FK4C s soft ramp up when the unit is turned on, and its soft ramp down after the thermostat is satisfied. These features increase efficiency and eliminate the annoying sounds associated with sudden changes in airflow. The FK4C also features Carrier s patented Easy Select Board. This board streamlines installation and helps the installer to select the correct airflow. The Easy Select Board combined with the ICM2 truly allows dealers to customize the heating and cooling system to each home. The FK4C is also loaded with the most advanced components, so you know it will perform like a premium fan coil should. Inside you will find grooved copper tubing and lanced sine wave aluminum fins, which contribute to the FK4C s high SEER and HSPF ratings. Carrier technology also incorporates boehmited coils, dedicated refrigerant circuitry, and Copyright 995 Carrier Corporation Form FK4C-PD

state-of-the-art Thermostatic Expansion Valve (TXV) refrigerant metering. All of this is packed in a rugged, prepainted metal cabinet that is lined with super-thick, high-density insulation. Obviously a unit built to last. In addition to superior quality, the FK4C also offers the ultimate in versatility. Compact and designed for upflow, downflow, and horizontal applications, the FK4C fits right where it is needed. It is equipped with sweat connections and has multiple electric entries for fast, simple installations. Carrier also offers the FK4C with factory- or field-installed electric resistance heat kits in sizes 5kw to 30kw. When the ultimate in efficiency, comfort, and durability is needed, the FK4C is the fan coil to use. Features c Programmable ICM2 blower motor c Easy Select Board c Grooved copper tube c Lanced sine wave aluminum fin c Discreet refrigerant circuits c Prepainted galvanized sheet metal cabinet c Cooling control in every unit c Static independent airflow c Logarithmic spiral blower housings for blower efficiency c High impact thermoplastic condensate pans c All units multipoise c Provision made for suspending from roof or ceiling joists c Modular cabinet design on 00 size c Factory-supplied cleanable, permanent framed filter c Easy access filter no tools required c Field-installed heater packages 5 30 kw, fused, circuit breaker, non-fused (0 kw and down) c Low-voltage terminal block c AMP plug connection provided for accessory heater packages c Connections for humidistat/humidifier c Connections for air cleaner relay c Blower on/off-delay time selections c Extra thick -in., R 4.2 high-density insulation c Tested for condensate disposal at conditions much more severe than those required by ARI c Sweat connections c Bi-flow hard shut-off TXV c Multiple electrical entry c Primary and secondary drain connections with brass inserts c Inspection plate on A-coil models c -/2 5 ton application c HUD approved for manufactured housing c Replaceable 5-amp blade-type auto fuse protects against transformer secondary short c 40 va, 20/230-v transformer c All models listed with UL, cul, ARI and RADCO c Independent fan only selections 2

Model number nomenclature F K 4 C N F 002 000 A A A A Fan Coil Variations ICM Motor, High Efficiency Variations Multipoise Series Series Variations Electrical 20/230/ Heating Size (kw) F High Density, -in. Thick Insulation B Both -in. Thick insulation and Modular Size Designation 00 005 002 00 003 AN INDEPENDENT LABORATORY ARY AIR CONDITIONING ARY HEAT PUMP CERTIFICATION LISTING TESTING INSPECTION TESTING FOR PUBLIC SAFETY MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 20 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 3

Dimensions 7 / 7/ DIA K.O. FOR LOW VOLTAGE CONTROL WIRING NOTES:. 2. 3. ALLOW 2.0 FROM FRONT FOR SERVICE. S WITH 20, 24 AND 30 K.W. HEATERS MUST MAINTAIN A MINIMUM OF.0 CLEARANCE FROM DISCHARGE DUCT CLEARANCE TO COMBUSTIBLE MATERIALS. WHEN INSTALLED OVER FINISHED CEILING/LIVING SPACE A FIELD SUPPLIED SECONDARY CONDENSATE PAN MUST BE INSTALLED. 5 / 5/ TOP VIEW 3 / (34.9) 7/, 3 /32 & 2.0 DIA FOR HIGH VOLTAGE POWER WIRING C B DISCONNECT OR CIRCUIT BREAKER LOCATION BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL COIL ACCESS PANEL CONNECTION SIZES SUCTION: 00 & 002-3 /4 I.D. SWEAT 003, 005 & 00 7 / SWEAT LIQUID: 3 / I.D. SWEAT CONDENSATE PAN CONNECTIONS: 3 /4 FPT UPFLOW/DOWNFLOW HORIZ A-COILS: 3 /4 FEMALE PVC GLUE JOINT VIA FITTINGS PROVIDED. 4 / SUCTION LINE CONNECTION LIQUID LINE CONNECTION LIQUID LINE CONNECTION G OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL S ONLY) INLET AIR ALTERNATE 7/ DIA K.O. FOR LOW VOLTAGE CONTROL WIRING 2 / A 0 3 / 22 / 7/ OUTLET AIR ALTERNATE 7/, 3 /32, 2.0 DIA K.O.'S FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE 3/4 NOTE: MODULAR S WILL HAVE A TWO- PIECE CABINET 2 5 / 0 7 / 5 LIQUID LINE CONNECTION FITTING PANEL SUCTION LINE CONNECTION 3 / 2 3 / 0 3 /4 9 /4 /4 / 9 /2 L MAX K FOR MODULAR S 3/4 OPENING F INLET AIR FILTER ACCESS PANEL FRONT VIEW SHOWN WITH A COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ APPLICATIONS SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORIZ LEFT APPLICATIONS ACCESS PANEL CONFIG FOR SLOPE COILS DOWNFLOW OR HORIZ RIGHT APPLICATIONS AND A COILS DOWNFLOW APPLICATIONS /4 20 / OPENING RIGHT SIDE VIEW INLET AIR 2 /2 A9530 A B C D E F G SIZE In. In. In. In. In. In. In. 00 47-5/ 7-5/ 5-3/4 23-3/ 5-3/ 002 42-/ 7-5/ 5-3/4 4-/4-3/ 0-3/4 FK4C 003 53-7/ 2-/ 9-/4 27 9-/2 9-3/ 005 53-7/ 2-/ 9-/4 4-5/ 27 9-/2 9-/2 00 59-3/ 24-/ 22-3/4 7-3/ 32-/ 23 25-/4 4

Dimensions continued PRIMARY DRAIN AIRFLOW 7 / (4 PLACES) (2 PLACES) AIRFLOW 3 H J 2 3 / (2 PLACES) 7 / PRIMARY DRAIN SECONDARY DRAIN / 2 /2 3 / E 3 / / 2 5 / SECONDARY DRAIN 2 3 / (2 PLACES) /2 3 2 5 / 3 / / 2 SECONDARY DRAIN PRIMARY DRAIN (2 PLACES) 7 / (4 PLACES) 5 / / 2 2 5 / H PRIMARY DRAIN /2 SECONDARY DRAIN /2 3 / 7 / 7 / SECONDARY DRAIN (INSTALL SPECIAL DAM FITTING) PRIMARY DRAIN HORIZ LEFT SLOPE COIL APPLICATION: AS SHIPPED HORIZONTAL MOUNT LOCATIONS DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM, HOLES PROVIDED 0.3 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. /2 3 / 5 / D HORIZ LEFT A COIL E 3 / APPLICATION: AS SHIPPED SECONDARY DRAIN PRIMARY DRAIN 2 3 / (2 PLACES) UPFLOW SLOPE COIL AIRFLOW 3 / 4 3 / 4 UPFLOW A COIL 7 / (4 PLACES) (2 PLACES) 3 2 / 4 3 / 4 DOWNFLOW SLOPE COIL AIRFLOW H J 3 / PRIMARY DRAIN SECONDARY DRAIN (2 PLACES) 7 / (4 PLACES) DOWNFLOW A COIL APPLICATION: FIELD CONVERTED 2 3 / (2 PLACES) 5 / APPLICATION: FIELD CONVERTED E HORIZ RIGHT SLOPE COIL SECONDARY DRAIN (INSTALL SPECIAL DAM FITTING) 3 / 5 / / 2 3 / 7 D / HORIZ RIGHT A COIL PRIMARY DRAIN A953 SIZE FK4C COIL CONFIGURATION OPERATING WEIGHT H J K L In. In. In. In. SLOPE A Lb 00 23 23-/2 7 Yes 2 002-7/ -/ Yes 20 003 2-3/ 27-3/ 9 Yes 45 005 27-/4 2-5/ Yes 2 00 32-5/ 32-5/ 34-/ Yes 95 5

Physical data SIZE 00 002 003 005 00* OPERATING WEIGHT (lb) 2 20 45 2 9 REFRIGERANT R-22 Metering Device TXV TXV SIZE 3 Ton 3 Ton 4 Ton 4 Ton 5 Ton COIL Type Slope A Slope A A Rows Fins/In. 3-4 Face Area (sq ft) 2.97 3.4 3.4 5.93 7.42 FAN Air Discharge Upflow, Downflow, Horizontal 55 / 40 55 / 40 730 / 790 795 / 55 25 / 225 CFM (Nominal Clg/Htg) 790 / 0 990 / 00 790 / 0 990 / 00 905 / 975 075 / 5 975 / 050 50 / 250 35 / 430 500 / 30 90 / 300 90 / 300 250 / 355 335 / 440 775 / 950 MOTOR HP (ECM) /2 /2 /2 /2 3/4 FILTER SIZE 2-/2 x -3/ 2-/2 x -3/ 2-/2 x -7/ 2-/2 x -7/ 2-/2 x 23-5/ * Modular Units Fan coil units with TXV must have a start capacitor and relay for single-phase outdoor units with reciprocating compressor. See outdoor unit presale literature.

Performance data FK4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART SIZE 00 002 003 005 00 OUTDOOR CAPACITY Nominal A/C Cooling Single Speed Application A/C Cooling Dehumidity OPERATING MODE COOLING Nominal A/C Cooling Two-Speed Application High Speed Low Speed A/C Cooling Dehumidify Nominal A/C Cooling NOTE: The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. Airflow can be adjusted +5% or 0% by selecting HI or LO respectively for all modes except fan only. Dry coil at 230 volts and with 0 kw heater and filter installed. Airflows shown are at standard air conditions. A/C Cooling Dehumidify FAN ONLY Lo/Med/Hi 0 525 440 440/440/525 024 700 50 440/455/700 030 75 700 440/570/75 03 050 40 00 0 0 545 525/0/050 0 525 440 440/440/525 024 700 50 440/440/700 030 75 700 440/570/75 03 050 40 00 0 0 545 525/0/050 024 700 50 55/55/700 030 75 700 55/570/75 03 050 40 00 0 0 545 525/0/050 042 225 90 0/795/225 030 75 700 530/570/75 03 050 40 00 0 0 545 530/0/050 042 225 90 0/795/225 04 400 20 470 75 90 725 700/90/400 03 050 40 00 0 745 595 540/745/050 042 225 90 0/70/225 04 400 20 470 75 995 795 700/995/400 00 750 400 35 470 240 995 75/240/750 SIZE 00 002 003 005 00 OUTDOOR CAPACITY FK4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART Heat Pump Comfort Single Speed Application Heat Pump Efficiency NOTE: The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. Airflow can be adjusted +5% or 0% by selecting HI or LO respectively. Dry coil at 230 volts and with 0 kw heater and filter installed. Airflows shown are at standard air conditions. OPERATING MODE HEAT PUMP ONLY HEATING Heat Pump Comfort Two-Speed Application High Speed Low Speed Heat Pump Efficiency Heat Pump Comfort Heat Pump Efficiency 0 470 525 024 30 700 030 75 75 03 945 050 990 00 5 0 0 470 525 024 30 700 030 75 75 03 945 050 990 00 5 0 024 30 700 030 75 75 03 945 050 990 00 5 0 042 00 225 030 75 75 03 945 050 990 00 5 0 042 00 225 04 20 400 320 470 20 90 03 945 050 990 00 70 745 042 00 225 04 20 400 325 470 95 995 00 575 750 55 35 20 240 7

Performance data continued AIRFLOW DELIVERY CHART (cfm) ELECTRIC HEATING MODES SIZE 00, 002 003 OUTDOOR ELECTRIC HEATER KW RANGE CAPACITY 0 5 0 0 0 5 0 20 BtuH Lo Nom Hi Lo Nom Hi Lo Nom Hi Lo Nom Hi,000 25 25 25 * * * * * * * * * 24,000 50 725 35 75 75 75 * * * * * * 30,000 5 905 040 75 905 040 975 975 040 00 00 00 3,000 90 05 250 90 05 250 90 05 250 00 00 250 24,000 75 725 35 75 75 75 * * * * * * 30,000 5 905 040 75 905 040 00 00 00 * * * 3,000 90 05 250 90 05 250 00 00 250 225 225 250 42,000 40 270 40 40 270 40 40 270 40 225 270 40 SIZE 005 00 OUTDOOR ELECTRIC HEATER KW RANGE CAPACITY 0 0 0 5 0 20 0 30 BtuH Lo Nom Hi Lo Nom Hi Lo Nom Hi Lo Nom Hi 30,000 975 975 040 00 00 00 * * * * * * 3,000 90 05 250 00 00 250 250 250 250 * * * 42,000 40 270 40 40 270 40 250 270 40 500 500 500 4,000 305 450 5 305 450 5 305 450 5 500 500 5 3,000 00 00 250 350 350 350 * * * * * * 42,000 40 270 40 350 350 40 525 525 525 * * * 4,000 305 450 5 350 450 5 525 525 5 750 750 750 0,000 30 0 205 30 0 205 30 0 205 750 0 205 * Airflow not recommended for heater/system size. NOTE: LO, NOM and HI refer to the AC/HP CFM ADJUST selection. MINIMUM CFM FOR ELECTRIC HEATER APPLICATION SIZE 00, 002 003 005 00 HEAT PUMP SIZE CFM Heater Size KW 5, 9, 0 5, 20 24, 30 Heater Only 25 25 725 75 0 25 024 50 725 75 030 00 75 75 040 03 970 970 970 040 Heater Only 75 700 050 050 024 75 75 050 030 00 75 00 03 975 975 00 225 042 25 25 25 225 Heater Only 75 700 050 050 400 030 00 75 00 03 975 975 00 225 042 25 25 25 225 04 305 305 305 305 400 Heater Only 050 050 050 050 750 03 00 00 350 350 042 25 25 350 350 04 300 300 350 45 750 00 25 25 25 750 750 NOTE: Heater Only Air Conditioner with electric heater application. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per the airflow delivery chart for Electric Heating Modes.

The airflow performance charts for the FK4C fan coil depict nominal airflow delivery for heating and cooling mode operation versus duct system static pressure drop. Cooling mode operation is shown as solid vertical lines for all four system size selections. Heating mode operation for the four system size selections are shown as dashed vertical lines. The dotted curved lines are static pressure drop characteristics for several fixed-duct systems. These lines can be used to predict the system static pressure drop at any airflow given the actual drop at one known point. For example, a duct system is designed for.5 inches water gage (iwg) drop at 200 CFM. The FK4CNF005 operating at nominal cooling airflow would deliver 050 CFM with a duct system drop of. iwg (see point ). The FK4CNF005 operating at nominal heating airflow would deliver 945 CFM at a duct system drop of.09 iwg (see point 2). This example is but one of many possible duct system designs. The FK4CNF005 will deliver the above airflows against much higher static pressures. AIRFLOW PERFORMANCE FKACNF005 NOM. CLG EXTERNAL STATIC PRESSURE (iwg).5 DUCT SYSTEMS NOM. HTG 2 03 945 SCFM 050 200 A9539 9

AIRFLOW PERFORMANCE FK4CNF00 NOMINAL COOLING NOMINAL HEATING 0.9 0. 03 HI COOLING 0.7 EXTERNAL STATIC PRESSURE (iwg) 0. 0.5 0.4 0.3 0.2 0. 0 400-0- --024-- --030-- --03-- 500 00 700 00 900 000 00 200 300 SCFM A95323 0

AIRFLOW PERFORMANCE FK4CNF002 NOMINAL COOLING NOMINAL HEATING 03 HI COOLING 0.9 0. 0.7 EXTERNAL STATIC PRESSURE (iwg) 0. 0.5 0.4 0.3 0.2 0. 0 400-0- -024- --030-- --03-- 500 00 700 00 900 000 00 200 300 SCFM A95324

.4 AIRFLOW PERFORMANCE FK4CNF003 NOMINAL COOLING NOMINAL HEATING.3.2 0.9 0.9 0.9 042 HI COOLING EXTERNAL STATIC PRESSURE (iwg) 0. 0.7 0. 0.5 0.4 0.3 0.2 0. 0 500 --024-- --030-- --03-- --042-- 00 700 00 900 000 00 200 300 400 500 SCFM A95325 2

.4.3 AIRFLOW PERFORMANCE FK4CNF005 NOMINAL COOLING NOMINAL HEATING.2 0.9 0.9 0.9 EXTERNAL STATIC PRESSURE (iwg) 0. 0.7 0. 0.5 04 HI COOLING 0.4 0.3 0.2 0. 0 00 --030-- --03-- --042-- --04-- 700 00 900 000 00 200 300 400 500 00 700 SCFM A9532 3

..7 AIRFLOW PERFORMANCE FK4CNB00 NOMINAL COOLING NOMINAL HEATING..5.4.3.2 00 HI COOLING. EXTERNAL STATIC PRESSURE (iwg).0 0.9 0. 0.7 0. 0.5 0.4 0.3 0.2 0. 0 00 --03-- --042-- --04-- --00-- 900 000 00 200 300 400 500 00 700 00 900 2000 200 SCFM A95327 4

Performance data continued COOLING CAPACITIES (MBtuh) SIZE 00 002 003 005 00 EVAPORATOR AIR Cfm BF See notes on pg.. COIL REFRIGERANT TEMPERATURE ( F) 35 40 45 50 55 Evaporator Air Entering Wet-Bulb Temperature ( F)* 72 7 2 72 7 2 72 7 2 72 7 2 72 7 2 00 43 34 27 3 30 23 33 25 9 2 20 4 22 4 2 0.03 9 20 2 7 9 5 3 4 3 2 00 52 42 34 4 37 2 40 30 22 33 24 7 2 7 4 0.05 24 2 27 22 23 24 9 20 2 7 7 4 5 4 900 5 4 37 50 40 3 44 33 24 3 2 9 2 5 0.0 2 2 30 24 25 27 2 22 23 9 9 5 5 00 4 52 42 57 45 35 49 3 2 4 29 22 32 2 0.07 30 33 35 27 29 3 24 2 27 2 23 22 7 9 300 70 57 4 2 50 39 54 42 3 45 33 25 35 23 20 0.09 32 3 39 29 33 35 2 29 3 23 2 25 9 2 20 500 40 32 2 3 2 22 32 24 27 9 4 2 3 0.04 9 7 4 4 5 2 2 3 0 0 50 50 40 32 45 3 27 39 30 22 33 24 2 7 4 0.07 2 22 23 9 20 2 7 4 5 2 3 4 75 5 49 3 53 42 32 4 35 27 39 2 22 3 20 0.0 24 2 2 22 24 25 9 2 22 7 9 9 5 000 2 5 4 5 45 35 50 3 29 42 30 24 33 22 20 0. 2 2 3 23 2 2 2 23 25 20 2 20 250 7 55 45 49 39 54 42 33 4 34 2 37 25 24 0.3 29 33 3 27 30 33 24 27 30 22 24 2 9 2 24 00 5 4 3 50 40 3 44 34 25 37 27 9 29 9 0.04 27 29 30 24 2 27 2 22 23 9 9 5 000 5 44 4 37 53 40 30 44 3 23 34 22 9 0.05 3 34 3 2 30 32 25 27 2 2 23 23 9 9 200 75 2 50 54 42 59 45 34 49 35 27 3 25 22 0.07 35 3 4 32 34 37 2 3 32 24 2 27 20 22 22 350 0 53 72 5 45 3 4 3 53 3 30 4 27 24 0.0 37 4 44 34 37 40 30 33 35 2 29 30 22 24 24 530 5 70 57 77 2 4 5 39 57 40 32 44 29 2 0.09 39 44 4 3 40 43 32 3 3 2 3 32 24 2 2 750 49 39 55 43 33 4 37 27 4 29 20 33 2 7 0.04 27 27 2 24 25 25 2 22 22 5 5 5 950 74 0 4 7 53 40 59 45 33 50 35 25 39 24 2 0.0 32 34 35 29 30 3 25 2 27 22 23 23 9 50 9 72 57 79 3 4 9 52 3 5 4 3 44 29 25 0.07 37 39 4 33 35 3 29 3 32 25 2 27 20 22 22 500 03 4 92 73 5 4 7 4 39 52 34 3 0.0 43 4 49 3 4 44 34 37 39 29 32 33 25 27 27 700 0 9 7 99 7 0 5 49 72 5 42 5 37 35 0. 45 50 53 4 45 4 3 39 42 3 34 3 27 29 30 050 77 2 50 9 55 43 47 35 52 3 27 4 27 22 0.0 34 3 37 3 32 33 27 2 29 23 25 24 20 20 20 300 00 2 5 90 7 55 79 0 45 47 37 49 32 27 0.02 42 45 47 37 40 42 33 35 37 29 3 32 23 25 24 750 7 9 77 0 4 5 93 7 53 7 5 4 0 40 34 0.04 4 53 57 44 4 52 39 43 4 34 3 39 29 3 3 2050 2 03 3 4 9 7 99 7 59 4 0 50 5 44 39 0.05 52 5 3 4 53 57 43 47 5 37 42 43 33 35 35 2300 32 0 7 9 95 75 05 0 3 3 54 70 47 42 0.0 55 2 50 57 45 5 54 40 45 4 35 39 3 5

* Saturated suction leaving evaporator coil. BF Bypass Factor Sensible Heat Capacity NOTES:. Net capacities shown include a deduction for evaporator fan motor heat. 2. Contact manufacturer for cooling capacities at conditions other than shown in table. 3. Formulas: sensible heat cap. Leaving db = entering db.09 x cfm Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) total capacity (Btuh) h lwb = h ewb 4.5 x cfm where h ewb = enthalpy of air entering coil. 4. Direct interpolation is permissible. Do not extrapolate. 0 F subtract (corr factor x cfm) from SHC. Above 0 F db, add (corr factor x cfm) to SHC. BYPASS FACTOR 0.0 0.20 0.30 SHC Correction Factor ENTERING AIR DRY-BULB TEMPERATURE ( F) 79 7 77 7 75 Under 75 2 3 4 5 Over 5 Correction Factor 0.9 0.7 0.7.9.74.53 2.94 2.2 2.29 3.92 3.49 3.05 Interpolation is permissible. Correction Factor =.09 x ( BF) x (db 0) 4.9 4.3 3.2 Use formula shown below 5. SHC is based on 0 F db temperature of air entering coil. Below Performance data continued ESTIMATED SOUND POWER LEVEL* SIZE 00 002 003 005 00 CONDITIONS OCTAVE BAND CENTER FREQUENCY CFM ESP RPM 3 25 250 500 000 2000 4000 400 0.25 0 57 53 52 4 4 42 00 0.25 750 3 59 55 54 50 4 44 00 0.25 45 4 0 5 55 5 49 45 000 0.25 955 5 57 5 52 50 4 200 0.25 00 2 5 55 55 5 47 400 0.25 20 2 5 55 55 5 47 400 0.25 0 57 53 52 4 4 42 00 0.25 750 3 59 55 54 50 4 44 00 0.25 45 4 0 5 55 5 49 45 000 0.25 955 5 57 5 52 50 4 200 0.25 00 2 5 55 55 5 47 400 0.25 20 2 5 55 55 5 47 400 0.25 555 57 53 52 4 4 42 00 0.25 00 3 59 55 54 50 4 44 00 0.25 0 4 0 5 55 5 49 45 000 0.25 725 5 57 5 52 50 4 200 0.25 00 2 5 57 53 5 47 400 0.25 5 2 5 57 53 5 47 00 0.25 975 7 3 59 5 5 52 4 400 0.25 555 57 53 52 4 4 42 00 0.25 00 3 59 55 54 50 4 44 00 0.25 0 4 0 5 55 5 49 45 000 0.25 725 5 57 5 52 50 4 200 0.25 00 2 5 57 53 5 47 400 0.25 5 2 5 57 53 5 47 00 0.25 975 7 3 59 5 5 52 4 00 0.25 575 3 59 55 54 50 4 44 00 0.25 0 4 0 5 55 5 49 45 000 0.25 55 5 57 5 52 50 4 200 0.25 720 2 5 57 53 5 47 400 0.25 75 2 5 57 53 5 47 00 0.25 0 7 3 59 5 54 52 4 00 0.25 935 4 0 57 57 53 49 2000 0.25 020 4 0 57 57 53 49 250 0.25 090 4 0 57 57 53 49 * Estimated sound power levels have been derived using the method described in the 97 ASHRAE Systems & Applications Handbook, chapter 52, p. 52.7. CFM Cubic Feet Per Minute ESP External Static Pressure RPM Revolutions Per Minute

Performance data continued AIRFLOW PERFORMANCE CORRECTION FACTORS The FK4C airflow performance table was developed using fan coils with 0 kw electric heaters (2 elements) in the units. For fan coils with heaters made up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use table for this correction. STATIC PRESSURE CORRECTION (in. wc) HEATER KW ELEMENTS Sizes 00 005 Size 00 0 0 +.02 +.03 5 +.0 +.02, 0 2 0 0 9, 5 3.02.03 20 4.04.0, 24, 30.0.0 * Inches water column FILTER STATIC PRESSURE DROP (In. wc)* CFM SIZE 400 00 00 000 200 400 00 00 2000 00 0.020 0.044 0.04 0.072 0.00 002 0.020 0.044 0.04 0.072 0.00 003 0.020 0.035 0.05 0.070 0.092 005 0.020 0.035 0.05 0.070 0.092 0.20 00 0.070 0.092 0.20 0.52 0.7 AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY TO WET COIL) CFM SIZE 00 700 00 900 000 00 200 300 400 500 00 00 0.03 0.040 0.05 0.03 0.073 0.0 0.092 002 0.02 0.0 0.022 0.02 0.034 0.040 0.049 003 0.02 0.034 0.042 0.052 0.03 0.075 0.03 0.09 0.09 0.0 005 0.00 0.00 0.00 0.02 0.05 0.07 0.020 0.023 0.027 0.030 NOTE: Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. CFM 00 200 300 400 500 00 700 00 900 2000 200 00 0.03 0.0 0.0 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.04 7

Accessories ITEM ACCESSORY P/N* FAN COIL SIZE USED WITH FK4C- Disconnect Kit KFADK00DSC Cooling controls and heaters through 0 kw Coil Brkt Kit (Downflow Slope) KFADC020SLP 00, 003 Coil Brkd Kit (Downflow A) KFADC030ACL 002, 005, 00 Downflow Base Kit KFACB020CFB 00, 002 Downflow Base Kit KFACB030CFB 003, 005 Downflow Base Kit KFACB040CFB 00 Filter Kit (2 Pack) KFAFK022MED 00, 002 Filter Kit (2 Pack) KFAFK032LRG 003, 005 Filter Kit (2 Pack) KFAFK042XXL 00 Single-Point Wiring Kit KFASP00SPK All Air Cleaner Relay Kit KFAIR020ACR All *Factory authorized and listed, field installed. Accessory Description and Usage. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 units for 3 kw through 0 kw electric resistance heaters and cooling controls. 2. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, and FA4 fan coils are used in downflow applications. 3. Downflow Base Kit This kit is designed to provide a in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, FA4, and FH4 fan coils are used in downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy-gage, high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 fan coils only with 5 kw and 20 kw heaters 5. Air Cleaner Relay The electronic air cleaner relay ensures the FK4C fan coil and electronic air cleaner work as a system. REQUIRED USE: This relay is required whenever an electronic air cleaner is used with an FK4C fan coil.. Fan Coil Filter The kit consists of fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace the filters in FK4, FC4, FB4, and FH4 fan coils. REQUIRED USE: All FA4A units unless a filter grille is used.

Electrical data S WITHOUT ELECTRICAL HEAT SIZE VOLTS-PHASE FLA MIN CKT AMPS Min Wire Size Awg* BRANCH CIRCUIT Max Wire Length (ft) 00 20/230-4.3 5.4 4 5 74 5 002 20/230-4.3 5.4 4 5 74 5 003 20/230-4.3 5.4 4 5 74 5 005 20/230-4.3 5.4 4 5 74 5 00 20/230-..5 4 00 0 5 * Use copper wire only to connect unit. If other than uncoated (nonplated) 75 F ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured way along wire path between unit and service panel for a maximum 2% voltage drop. FLA Full Load Amps 20v 230v Fuse Amps Accessory electric heaters ELECTRIC HEATERS HEATER P/N KW @ 240V VOLTS/PHASE KW/ STAGE INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING CAP. @ 230V KFAEH020N05 5 230/ 5 None** All 5,700 KFAEH030N0 230/ None** All 25,00 KFAEH040N0 0 230/ 0 None** All 3,400 KFAEH20F5 5 230/ 5, 0 Fuses All 47,00 KFAEH00F20 20 230/ 0, 0 Fuses All 2,00 KFAEH250N09 9 230/* 3, None** All 2,300 KFAEH0035 5 230/3 5, 0 None** All 47,00 KFAEH0903 230/3,, None** 003, 005, 00 5,500 KFAEH00F24 24 230/3,, Fuses 005, 00 7,500 KFAEH0F30 30 230/3 0, 0, 0 Fuses 005, 00 94,200 KFAEH30C05 5 230/ 5 Ckt Bkr** All 5,700 KFAEH40C0 230/ Ckt Bkr** All 25,00 KFAEH50C0 0 230/ 0 Ckt Bkr** All 3,400 KFAEH20C5 5 230/ 5, 0 Ckt Bkr** All 47,00 KFAEH70C20 20 230/ 0, 0 Ckt Bkr** All 2,00 KFAEH270S5 5 230/ 5, 0 Fused All 47,00 KFAEH90S20 20 230/ 0, 0 Fused All 2,00 * These heaters field convertable to three phase. These heaters field convertable to single phase. Blower motor heat not included. ** cul approved. ELECTRIC HEATER INTERNAL PROTECTION HEATER KW PHASE FUSES QTY/SIZE CKT BKR QTY/SIZE 5 2/0 2/0 0 2/0 5 2/30, 2/0 4/0 20 4/0 4/0 24 3/ /0 30 3/ /0 9

Electric heater electrical data ELECTRIC HEATER ELECTRICAL DATA ACCESSORY HEATER P/N KFAEH00N03 KFAEH20C03 KFAEH020N05 KFAEH30C05 KFAEH030N0 KFAEH40N0 KFAEH250N09 KFAEH040N0 KFAEH50C0 KFAEH20F5 KFAEH270S5 KFAEH20C5 KFAEH0035 KFAEH0903 KFAEH00F20 KFAEH90S20 KFAEH70C20 KFAEH00F24 KFAEH0F30 kw 240V 20V 3 2.3 3 2.3 5 3. 5 3..0.0 9. 0 7.5 0 7.5 5.3 5.3 5.3 5.3 3.5 20 5.0 20 5.0 20 5.0 24.0 24.0 30 22.5 30 22.5 PHASE 3 3 3 3 3 INTERNAL CIRCUIT PROTECTION CB CB CB CB FUSE FUSE CB FUSE FUSE CB FUSE FUSE FUSE FUSE SINGLE CIRCUIT 0.9/2.0 0.9/2.0./20.0./20.0 2.9/32.0 2.9/32.0./20. 3.2/40.0 3.2/40.0 54.2/59.9 54.2/59.9 3.3/34. 37./4.5 72.3/79.9 72.3/79.9 50./55.4.7/95.9 2./9.2 09.0/ 20.0 HEATER AMPS 20/230V DUAL CIRCUIT L, L2 L3, L4 3.2/40.0 3.2/40.0 3.2/40.0 3.2/40.0 3.2/40.0 3.2/40.0./20.0./20.0./20.0 3.2/40.0 3.2/40.0 3.2/40.0 SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4.2/7.5.2/7.5 2.7/29.0 2.7/29.0 43.0/4.9 43.0/4.9 30.4/32.9 52.2/5.9 52.2/5.9 74.7/. 74.7/. 4.0/50.2 53.9/5. 97.3/0. 97.3/0. 9.5/7.2.0/27.0 9.5/7.2 43.0/57.0 MIN AMPACITY* 20/230V 52.2/5.9 52.2/5.9 52.2/5.9 52.2/5.9 52.2/5.9 52.2/5.9 22.7/25.0 22.7/25.0 22.7/25.0 45.3/50.0 45.3/50.0 45.3/50.0 MIN WIRE SIZE (AWG) 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4 2 2 0 0 / 3/2 3/2 0/00 4 4 4 3 0 0 0 BRANCH CIRCUIT MIN GND WIRE SIZE 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4 2 2 0 0 0 0 0 0 0 0 0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 FUSE/CKT BKR AMPS 20/230V SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4 20 20 25/30 25/30 45/50 45/50 9. 32./3.0 47.9/5.9 0 50/0 94/9 35/35 0/0 0/0 0/90 0/90 50/50 0/0 00/0 00/0 70/0 25/50 90/00 50/75 0/0 0/0 0/0 0/0 0/0 0/0 25/25 25/25 25/25 50/50 50/50 50/50 MAX WIRE LENGTH** FOR 2% VOLTAGE DROP 20/230V (FT) SINGLE DUAL CIRCUIT CIRCUIT L, L2 L3, L4 3/5 3/5 /2 /2 /2 /2 0/ 7/79 7/79 /7 /7 7/2 94/95 4/0 4/0 /7 2/3 20/2 4/45 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 5/5 5/5 5/5 FIELD MULTIPOINT WIRING OF 24- AND 30-KW SINGLE PHASE HEATER PART NO. KW 240V 20V PHASE HEATER AMPS 20/230V MIN AMPACITY 20/230V* MIN WIRE SIZE (AWG) 20/230V MIN GND WIRE SIZE 20/230V FUSE/CKT BKR AMPS 20/230V MAX WIRE LENGTH** FOR 2% VOLTAGE DROP 20/230V (FT) L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L L/L2 L3/L4 L5/L KFAEH00F24 24 2.9/32.0 2.9/32.0 2.9/32.0 43.0/4.9 3./40.0 3./40.0 0 45/50 40/45 40/45 /2 73/73 73/73 KFAEH0F30 30 22.5 3.2/40.0 3.2/40.0 3.2/40.0 52.2/5.9 45./50.0 45./50.0 0 0/0 50/0 50/0 7/79 5/5 5/5 * ** CB Circuit Breaker Includes blower motor amps of largest fan coil is used with heater. CSA fused with single point wiring adapter Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used, consult applicable tables of the National Electronic Code (ANSI/NFPA 70). Length is as measured one way along wire path between unit and service panel for a maximum voltage drop not to exceed 2%. NOTE: The 24- and 30-kw heaters are convertible to -phase, single or multiple supply circuit. The 9-kW heaters are convertable to three phase. Single circuit application of F5 and F20 heaters requires single-point wiring kit accessory. A9532 20

Matched system HEAT PUMP HUMIDIFIER FAN COIL AIR FLOW ELECTRONIC AIR CLEANER A9202 2

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG -00-92-922 [ ] Packaged Service Training [ ] Classroom Service Training A9432 Copyright 995 Carrier Corporation Syracuse, New York 322 9-95 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 Page 22 Catalog No. 92-32FK-4CC Printed in U.S.A. PC 0 Form FK4C-PD Tab 3d 2e Replaces: FK4B-PD