Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Similar documents
Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

Optical laser distance sensors. Dimensioned drawing

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

PHOTOELECTRIC AMPLIFIER SERIES

5.0. Photoelectric Sensors. Technical Reference. Introduction

Retroreflective sensor with polarization filter

Retroreflective sensor with polarization filter

E3M-V. Mark Sensor. Applications

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Retro-reflective Sensing range: 0mm to 2000mm

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

MSI Safety relays. MSI-T functions

BOS 23K. Photoelectric Sensors BOS 23K

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

CATALOGUE LASER POINTERS

FR Series Photoelectric Sensors

OG-Cube Photoelectric Sensors Optical sensing technology

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

2 General Application Photoelectric Sensors

Class 1 laser beam sensor safe for your eyes

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Class 1 laser beam sensor safe for your eyes

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

Danfoss gas detection units

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Multifunctional Gate Box MGB. More than safety.

Class 1 laser beam sensor safe for your eyes

2 General Application Photoelectric Sensors

English. Series. Installation and Use Manual

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

E3FA PHOTOELECTRIC SENSORS

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Compact Catalog Solar

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

INFRARED MODULATED BARRIERS

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors

Automatic Self-Adjusting General Purpose Sensor

Reflective Optical Beam Smoke Detector User Guide

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

max C 15 minutes other types on request 3 x 0,25 mm2 or plug M8, other types on request

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Laser Collimated Beam Sensor

General Purpose Photoelectric Sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Power Supply Display Module PSDM. Installation and Operation Manual

2 General Application Photoelectric Sensors

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Safety Light Curtains Area Access Control

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

The Affordable, All-Purpose Sensor That's EZ To Use!

Danfoss gas detection units

Laser Distance Sensor Type M Analog-Output

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

Plug-in Base, Long Range Sensor E3B2

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

S15 SERIES. Ceramics. Beverage & Bottling

PolyGard 2-channel Gas Controller MGC-03

E3FA PHOTOELECTRIC SENSORS

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Fire Damper Interface (230V)

Smoke Fire Damper Interface (230V)

Smoke Damper Interface (230V)

Ultrasonic Proximity Sensor

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

General Specifications

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

INSTRUCTION & SERVICE MANUAL

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

OI Series Photoelectric Sensors. Switchpoint with Distance

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Leuze electronic. Mounting systems. for optical electronic sensors

Synchronous Detector

Innovation right to the point. Optical distance detection. Low cost and compact due to PMD technology.

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

COMPACT FLAME CONTROLLER CFC 2000

Fire Damper Interface (24V)

02/11/2015

E3FA PHOTOELECTRIC SENSORS

GENERAL APPLICATION SENSORS NEW! MINI-EYE. General Application Photoelectric Sensors. Small, Rugged and Powerful... yet Low in Price MINI-EYE 2-55

Technical Data. General specifications. Rated operating distance s n 5 mm

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

MINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. General Purpose Photoelectric Sensor

Transcription:

Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via M12 connector or terminal compartment Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures A B C D E F G H I Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment ISO 91 U L US C LISTED Electrical connection Transmitter Receiver We reserve the right to make changes 96_a2e.fm IEC 6947... IEC 6947... Accessories: IP 69K IP 67 Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) M12 connectors (KD ) Ready-made cables (K-D ) Alignment aid ARH 96

Specifications Optical data Infrared light Typ. operating range limit 1) 15m Operating range 2) 12m Light source LED (modulated light) Wavelength 88nm Timing Switching frequency 5Hz Response time 1ms Delay before start-up 2ms Electrical data Operating voltage U B 1 3VDC (incl. residual ripple) Residual ripple 15% of U B Bias current 5mA, 13mA with optional optics heating Switching output PNP transistor Function characteristics light/dark switching Signal voltage high/low (U B -2V)/ 2V (PNP) Output current max. 1mA Sensitivity adjustable Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 38g Connection type terminals, M12 connector Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 3) 1, 2, 3 VDE safety class 4) II, all-insulated Protection class IP 67, IP 69K 5) LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 Options Activation input activ Transmitter active/not active 8V/ 2V ( 2V/ 2V) 6) Activation/disable delay.5ms Input resistance 47KΩ ±1% Warning output autocontrol warn PNP transistor, 1mA, counting principle Optics heating for temperature changes, prevents fogging Low temperature to -35 C Switching delay (slow oper./release) 1s (separately adjustable) 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 25VAC 5) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test 6) Active high Order guide Selection table Equipment Order code M/P-31-2 Part No. 5 25225 (Tr) Part No. 5 34128 (Re) M/P-31-4 Part No. 5 25228 (Tr) Part No. 5 34128 (Re) M/P-312-2 Part No. 5 25223 (Tr) Part No. 5 33328 (Re) M/P-312-4 Part No. 51 329 (Tr) Part No. 51 3291 (Re) Housing metal Light source infrared light (12m) Connection terminals M12 connector Features optics heating/low temp. activation input 6) 6) Tables 12 15 Operating range [m] Typ. operating range limit [m] Diagrams Misalignment y [m] 3,5 2,5 1,5,5 -,5-1,5-2,5-3,5 2 4 6 8 1 12 14 16 x Remarks LS = Pair consisting of LSS = Transmitter LSE = Receiver M/P-31-2 LSS 96M-17-23 LSE 96M/P-31-21 M/P-31-4 LSS 96M-17-43 LSE 96M/P-31-41 M/P-312-2 LSS 96M-19-24 LSE 96M/P-312-21 M/P-312-4 LSS 96M-19-43 LSE 96M/P-312-41

Throughbeam photoelectric sensors Dimensioned drawing 39m 65m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in visible red light or infrared light Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application Complementary outputs for standard applications and a wide range of input and output variants for optimum adaptation to the application Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures A B C D E F G H I K Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Device plug M18x1 Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment ISO 91 U L US C LISTED Electrical connection We reserve the right to make changes 96_a11e.fm IEC 6947... IEC 6947... IP 67 Accessories: Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) M12 connectors (KD ) Ready-made cables (K-D ) Alignment aid ARH 96

Specifications Optical data Infrared light Red light Typ. operating range limit 1) 65m 39m Operating range 2) 5m 3m Light source LED (modulated light) LED (modulated light) Wavelength 88nm 66nm Timing Switching frequency 5Hz Response time 1ms Delay before start-up 2ms Electrical data Operating voltage U B 1 3VDC (incl. residual ripple) Residual ripple 15% of U B Bias current 5mA, 13mA with optional optics heating Switching output NPN or PNP transistor Function characteristics light/dark switching Signal voltage high/low (U B -2V)/ 2V (PNP) Output current max. 1mA Sensitivity adjustable Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Plastic housing Housing polycarbonate Optics cover plastic Weight 15g Connection type terminals or M12 connector Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 3) 1, 2, 3 VDE safety class 4) II, all-insulated Protection class IP 67 LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 Options Activation input activ Transmitter active/not active 2V/ 8V 5) Activation/disable delay.5ms Input resistance 47KΩ ±1% Warning output autocontrol warn PNP transistor, 1mA, counting principle Optics heating for temperature changes, prevents fogging Low temperature to -35 C Switching delay (slow oper./release) 1s (separately adjustable) 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 25VAC 5) Active low Order guide Selection table Equipment Housing Order code K/P-11-4 Part No. 5 25254 (Tr) Part No. 5 25258 (Re) K/P-13-2 Part No. 5 25255 (Tr) Part No. 5 25259 (Re) K/P-13-4 Part No. 5 25254 (Tr) Part No. 5 8483 (Re) K/P-114-2 Part No. 5 8657 (Tr) Part No. 5 31295 (Re) K/P-115-4 Part No. 5 25254 (Tr) Part No. 51 34 (Re) K/P-11.1-4 Part No. 5 25254 (Tr) Part No. 51 3218 (Re) metal plastic Light source red light (3m) infrared light (5m) Connection terminals M12 connector Features switching delay warning output activation input 5) PIN 2 = NC * PIN 4 = dark switching PIN 4 = light/dark reversible Leuze electronic Tables Red light 3 39 Infrared light 5 65 Operating range [m] Typ. operating range limit [m] Diagrams Red light Misalignment y [m] 4 3 2 1-1 -2-3 Infrared light Misalignment y [m] -4 5 1 15 2 25 3 35 4 45 5 1,,8,6,4,2 -,2 -,4 -,6 -,8-1, 1 2 3 4 5 6 7 x Remarks The throughbeam photoelectric sensor is also available with integrated AS-i chip for direct connection to the AS-i system. *For direct connection to AS-i I/O coupling modules (K/P-115-4 and K/P-11.1-4)

Throughbeam photoelectric sensors Dimensioned drawing 39m Throughbeam photoelectric sensors with high performance reserve in red light Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application Receiver with integrated AS-i slave technology Transmitter without integrated AS-i slave technology; receives voltage supply via AS-i line Wide angle version to simplify the alignment A B C D E Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Countersinking for SK nut M5, 4.2 deep ISO 91 U L US C LISTED Electrical connection We reserve the right to make changes 96_a9e.fm IEC 6947... IEC 6947... Accessories: Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) M12 connectors Ready-made cables (K-D ) Alignment aid ARH 96 AS-i Accessories: IP 69K IP 67 Bus terminals AS-i ribbon cable Address programming device Coupling modules, intermediate cables, etc.

Specifications Optical data Typ. operating range limit 1) 39m Operating range 2) 3m Light source LED (modulated light) Wavelength 66nm (red light) Timing Sensor switching frequency 5Hz Sensor response time 1ms Delay before start-up 2ms Electrical data Operating voltage U B 26.5 31.6V (according to AS-i specification) Bias current receiver 35mA Bias current transmitter 15mA Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 38g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 3) 1, 2 VDE safety class 4) II, all-insulated Protection class IP 67, IP 69K 5) LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 AS-i data for receiver I/O code 1 ID code 1 Cycle time acc. to AS-i specification 5ms AS-i standard according to profile S-1.1 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection 4) Rating voltage 25VAC 5) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables 3 39 Operating range [m] Typ. operating range limit [m] Diagrams Misalignment y [mm] 4 3 2 1-1 -2-3 -4 5 1 15 2 25 3 35 4 45 5 x Assignment: data bits Assignment: parameter bits Programming (host level) Programming (host level) D Switching output input NC Ø no reflection System Ø *P 1 reflection 1 D 1 Warning output Ø active System *P Light/dark Ø dark switching autocontrol 1 not active input 1 switching 1 light switching D 2 Ready output Ø sensor not ready System Ø *P input 2 NC 1 sensor ready 1 *D 3 NC Ø Ø *P 3 NC 1 1 * default = 1 Order guide Designation Part No. Transmitter and receiver M/A-182W-4 Transmitter LSS 96 M-18W-44 5 824 Receiver LSE 96 M/A-182W-44 5 8239 System parameter System parameter System parameter System parameter Remarks The transmitter has no integrated AS-i slave technology. The low current consumption of the transmitter enables power supply via AS-i line. Transmitter and receiver behave like a slave in an AS-i branch. Angle at 3m distance: Transmitter: Angle of radiation typ.: 1 Receiver: Receiving angle typ.: 12

Throughbeam photoelectric sensors Dimensioned drawing 39m 2-23 V AC / DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in red light Wide angle version for easy alignment Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application All-mains design 2 23VAC/DC with relay output Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via comfortable terminal compartment up to 1.5mm 2 A B C D E F G H Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment We reserve the right to make changes 96_a6e.fm ISO 91 IEC 6947... IEC 6947... Accessories: U L US C LISTED IP 69K IP 67 Mounting systems (BT 96, BT 96.1, BT 96.4, UMS 96, BT 45.1-96) Spark extinction Alignment aid ARH 96 Electrical connection (example) Transmitter Receiver

Specifications Optical data Typ. operating range limit 1) 39m Operating range 2) 3m Light source LED (modulated light) Wavelength 66nm (red light) Timing Switching frequency 2Hz Response time 25ms Delay before start-up 2ms Electrical data Operating voltage U B 2 23VAC, 5/6Hz 2 23VDC Power consumption 1.5VA Switching output 3) relay, 1 change-over contact Function characteristics break-contact/make-contact Switching voltage, relay 25VAC/DC Switching current, relay 25VAC, 3A/3V, 3A Bias current 75VA, cosϕ=1 Sensitivity adjustable Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 38g Connection type terminals transmitter cable 3x.5mm 2 (oil flex 11), 1.5m receiver cable 3x.5mm 2 (oil flex 11), 1.5m Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 4) 1, 2, 3 VDE safety class 5) II, all-insulated Protection class IP 67, IP 69K 6) LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 25VAC 6) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables 3 39 Operating range [m] Typ. operating range limit [m] Diagrams Misalignment y [mm] 125 1 75 5 25-25 -5-75 -1-125 1 2 3 4 x Order guide Selection table Equipment Order code M/R-176W-2 Part No. 5 324 (Tr) Part No. 5 323 (Re) Housing metal Light source red light (3m) Connection terminals cable tail 1.5m Remarks Angle at a distance of 3m: transmitter: angle of radiation typ. 1 receiver: receiving angle typ. 12 Cable version wire assignment: 1,2 = supply 3,4 = break-contact LS = Pair consisting of LSS = Transmitter LSE = Receiver M/R-176W-2 LSS 96M-175W-26 LSE 96M/R-176W-25

Throughbeam photoelectric sensors Dimensioned drawing en 1-212/8 51289 65m 15m 2-23 V AC / DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application All-mains design 2 23VAC/DC Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via comfortable terminal compartment up to 1.5mm² Version with additional switching delay A B C D E F G H Green indicator diode Yellow indicator diode Optical axis Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment We reserve the right to make changes DS_LS96MKR_en_51289.fm IEC 6947... IEC 6947... Accessories: IP 69K IP 67 Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) Spark extinction Alignment aid ARH 96 Electrical connection (example) Transmitter Receiver

Specifications Optical data 65m 15m Typ. operating range limit 1) 65m 15m Operating range 2) 5m 12m Light source LED (modulated light) Wavelength 88nm (infrared) Timing Switching frequency 2Hz Response time 25ms Delay before start-up 2ms Electrical data Operating voltage U B 2 23VAC, 5/6Hz 2 23VDC Power consumption 1.5VA Switching output 3) relay, 1 change-over contact Function characteristics break-contact/make-contact Switching voltage, relay 25VAC/DC Switching current, relay 25VAC, 3A/3V, 3A Open-circuit current 75VA, cos =1 Sensitivity adjustable Indicators Green LED ready Yellow LED light path free Yellow LED, flashing light path free, no performance reserve Mechanical data Metal housing Plastic housing Housing diecast zinc polycarbonate Optics cover glass plastic Weight 38g 15g Connection type terminals terminals Environmental data Ambient temp. (operation/storage) -3 C +6 C/-4 C +7 C Protective circuit 4) 1, 2, 3 VDE safety class 5) II, all-insulated Protection class IP 67, IP 69K 6) IP 67 Light source exempt group (in acc. with EN 62471) Standards applied IEC 6947-5-2 Options Switching delay (slow oper./release) 1s (separately adjustable) 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 5) Rating voltage 25VAC 6) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Approved purpose: This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. Tables 65m models 5 65 15m models 12 15 Operating range [m] Typ. operating range limit [m] Diagrams 65m models Misalignment y [m] 15m models Misalignment y [m] 1,,8,6,4,2 -,2 -,4 -,6 -,8-1, 1 2 3 4 5 6 7 3,5 2,5 1,5,5 -,5-1,5-2,5-3,5 2 4 6 8 1 12 14 16 x Remarks K/R-131P-2 P = Reduction M16 Order guide Selection table Order code K/R-131-2 Part No. 525253 (Tr) Part No. 525257 (Re) K/R-132-2 Part No. 525253 (Tr) Part No. 525256 (Re) M/R-131-2 Part No. 5881 (Tr) Part No. 588 (Re) M/R-331-2 Part No. 5881 (Tr) Part No. 531651 (Re) K/R-131P-2 Part No. 5345 (Tr) Part No. 5346 (Re) Equipment Housing metal plastic Light source infrared light (5m) infrared light (12m) Connection terminals Features switching delay UL homologation LS = Pair consisting of LSS = Transmitter LSE = Receiver K/R-131-2 LSS 96K-135-26 LSE 96K/R-131-25 K/R-132-2 LSS 96K-135-26 LSE 96K/R-132-25 M/R-131-2 LSS 96M-135-26 LSE 96M/R-131-25 M/R-331-2 LSS 96M-135-26 LSE 96M/R-331-25 K/R-131P-2 LSS 96K-135P-26 LSE 96K/R-131P-25

Throughbeam photoelectric sensors Dimensioned drawing 39m 1-3 V DC A 2 LS Powerful throughbeam photoelectric sensors with performance reserve in visible red light Wide angle version for easy alignment Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via M12 connector or comfortable terminal compartment up to 1.5mm 2 A B C D E F G H I Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment We reserve the right to make changes 96_a3e.fm ISO 91 IEC 6947... IEC 6947... Accessories: U L US C LISTED IP 69K IP 67 Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) M12 connectors (KD ) Ready-made cables (K-D ) Alignment aid ARH 96 Electrical connection Transmitter Receiver

Specifications Optical data Red light Typ. operating range limit 1) 39m Operating range 2) 3m Light source LED (modulated light) Wavelength 66nm Timing Switching frequency 5Hz Response time 1ms Delay before start-up 2ms Electrical data Operating voltage U B 1 3VDC (incl. residual ripple) Residual ripple 15% of U B Bias current 5mA Switching output PNP transistor Function characteristics light/dark switching Signal voltage high/low (U B -2V)/ 2V (PNP) Output current max. 1mA Sensitivity adjustable Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 38g Connection type terminals, M12 connector Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 3) 1, 2, 3 VDE safety class 4) II, all-insulated Protection class IP 67, IP 69K 5) LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 25VAC 5) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables 3 39 Operating range [m] Typ. operating range limit [m] Diagrams Misalignment y [mm] 4 3 2 1-1 -2-3 -4 5 1 15 2 25 3 35 4 45 5 x Remarks Angle at a distance of 3m: transmitter: angle of radiation typ. 1 receiver: receiving angle typ. 12 Order guide Selection table Equipment Order code M/P-181W-4 Part No. 5 31574 (Tr) Part No. 5 31575 (Re) M/P-181W-2 Part No. 5 32835 (Tr) Part No. 5 32741 (Re) M/P-1816-4 Part No. 5 32129 (Tr) Part No. 5 32128 (Re) Housing metal Light source red light (3m) Connection terminals M12 connector Features fixed sensitivity setting optics heating/low temp. LS = Pair consisting of LSS = Transmitter LSE = Receiver M/P-181W-4 LSS 96M-12W-43 LSE 96M/P-181W-41 M/P-181W-2 LSS 96M-12W-23 LSE 96M/P-181W-21 M/P-1816-4 LSS 96M-126-43 LSE 96M/P-1816-41

Specifications and description Leuze electronic Throughbeam photoelectric sensors Dimensioned drawing 39m 65m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in visible red light or infrared light Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via M12 connector or terminal compartment Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures A B C D E F G H I K Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Device plug M18x1 Screwed cable gland M16x1.5 for Ø 5 1mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment We reserve the right to make changes 96_a1e.fm ISO 91 IEC 6947... IEC 6947... Accessories: U L US C LISTED IP 69K IP 67 Mounting systems (BT 96, BT 96.1, UMS 96, BT 45.1-96) M12 connectors (KD ) Ready-made cables (K-D ) Alignment aid ARH 96 Electrical connection

Specifications Optical data Infrared light Red light Typ. operating range limit 1) 65m 39m Operating range 2) 5m 3m Light source LED (modulated light) LED (modulated light) Wavelength 88nm 66nm Timing Switching frequency 5Hz Response time 1ms Delay before start-up 2ms Electrical data Operating voltage U B 1 3VDC (incl. residual ripple) Residual ripple 15% of U B Bias current 5mA, 13mA with optional optics heating Switching output NPN or PNP transistor Function characteristics light/dark switching Signal voltage high/low (U B -2V)/ 2V (PNP) Output current max. 1mA Sensitivity adjustable Indicators LED green ready LED yellow light path free LED yellow flashing light path free, no performance reserve Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 38g Connection type terminals or M12 connector Environmental data Ambient temp. (operation/storage) -2 C +6 C/-4 C +7 C Protective circuit 3) 1, 2, 3 VDE safety class 4) II, all-insulated Protection class IP 67, IP 69K 5) LED class 1 (acc. to EN 6825-1) Standards applied IEC 6947-5-2 Options Activation input activ Transmitter active/not active 8V/ 2V ( 2V/ 2V) 6) Activation/disable delay.5ms Input resistance 47KΩ ±1% Warning output autocontrol warn PNP transistor, 1mA, counting principle Optics heating for temperature changes, prevents fogging Low temperature to -35 C Switching delay (slow oper./release) 1s (separately adjustable) 1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 25VAC 5) IP 69K test acc. to DIN 45 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test 6) Active high Order guide Selection table Equipment Order code M/P-14-4 Part No. 5 25228 (Tr) Part No. 5 2525 (Re) M/P-113-2 Part No. 5 25223 (Tr) Part No. 5 2521 (Re) M/P-117-2 Part No. 5 25217 (Tr) Part No. 5 25195 (Re) M/P-117-4 Part No. 5 25219 (Tr) Part No. 5 25197 (Re) M/N-11-2 Part No. 5 25225 (Tr) Part No. 5 31295 (Re) Housing metal plastic Light source red light (3m) infrared light (5m) Connection terminals M12 connector Features optics heating/low temp. switching delay warning output activation input 6) NPN switching output Tables Red light 3 39 Infrared light 5 65 Operating range [m] Typ. operating range limit [m] Diagrams Red light Misalignment y [mm] 4 3 2 1-1 -2-3 -4 5 1 15 2 25 3 35 4 45 5 Infrared light Misalignment y [m] 1,,8,6,4,2 -,2 -,4 -,6 -,8-1, 1 2 3 4 5 6 7 x Remarks The throughbeam photoelectric sensor is also available with integrated AS-i chip for direct connection to the AS-i system.