GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Similar documents
DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ComfortNet -Compatible

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AMVM97 (B) / ACVM97 (B)

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

GKS9 40" 90% Gas Furnaces

Technical Information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

TECHNICAL INFORMATION MANUAL

AVPTC. Air Handlers 1½ to 5 Tons

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

AVPTC Multi-Position, Internal Txv

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

TECHNICAL SPECIFICATIONS

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

TECHNICAL SPECIFICATIONS

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Operator: Save these instructions for future use!

FG7T (C and L Series)

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

AVPTC. Air Handler 1½ to 5 Tons

RG7D 1-Stage Heat Series

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

MBR. Multi-Position. Modular Blower

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

TECHNICAL SPECIFICATIONS

MERIT SERIES Downflow

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL INFORMATION MANUAL

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

50A Integrated Furnace Control

Technical Manual MAY 2008 Edition

40 Residential Gas Furnace Operation

Wt. Lbs Model Number (BTUH) Hz

Operator: Save these instructions for future use!

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

50A Integrated Furnace Control

Operator: Save these instructions for future use!

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Ruud Achiever Plus Series Multi-position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

MULTI POSITION GAS FURNACE

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Rheem Classic Series Multi-position Gas Furnaces

Operator: Save these instructions for future use!

Multi-Position Gas Furnaces

Operator: Save these instructions for future use!

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

TECHNICAL SPECIFICATIONS

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Transcription:

Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams... 6 Accessories... 8 Minimum Filter Sizes... 8 Standard Features Energy-efficient, multi-speed EM blower motor Heavy-duty aluminized steel dualdiameter, tubular heat exchanger Two-stage convertible gas valve automatically adjust to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Self-diagnostic control board with constant memory fault code olor-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Multi-speed blower motor Low continuous fan speed options offer quiet air circulation alifornia Low NOx emissions models available AHRI ertified; ETL Listed abinet Features Multi-position installation: upflow, horizontal left or right with kit abinet air leakage (QLeak) 2% onvenient left or right connection for gas and electrical service Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section * omplete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS- www.goodmanmfg.com 11/15 Supersedes 9/15

Nomenclature G M E 80 040 3 B X A A 1 2 4 5,6 7,8,9 10 11 12 13 14 Brand Minor Revision G - Goodman Brand A - Initial Release B - First Revision onfiguration - Downflow/Horizontal Major Revision D - Dedicated Downflow A - Initial Release M - Upflow/Horizontal B - First Revision Gas Valve NOx E - Multi- Speed EM N - Natural Gas H - onvertible Two- Stage, Single Phase X - Low NOx S - Single Stage, Single Speed abinet Width AFUE A - 14" - 21" 80-80% AFUE B - 17½" D - 24½" MBTU/h Maximum FM 040-40,000 BTU/h 100-100,000 BTU/h 3-1200 FM 060-60,000 BTU/h 120-120,000 BTU/h 4-1600 FM 080-80,000 BTU/h 140-140,000 BTU/h 5-2000 FM 2 www.goodmanmfg.com SS-

Product Specifications 0603B*B 0805*B 0805D*A 1005*B Performance Data Input¹ 60,000 80,000 80,000 100,000 Output¹ 48,000 64,000 64,000 80,000 LP Output¹ 48,000 64,000 64,000 80,000 AFUE² 80 80 80 80 Tons A @ 0.5 ESP 3 5 5 5 Temperature Rise Range ( F) 20-50 35-65 30-60 35-65 irculator Blower Size (D x W) 10 X 8 10 X 10 10 X 10 10 X 10 HP 1/2 1 1 1 Speed 5 5 5 5 Vent Diameter³ 4 4 4 4 No. of Burners 3 4 4 5 Disposable Filter (in²) 290 480 480 480 Electrical Data Min. ircuit Ampacity⁴ 8.2 14.8 14.8 14.8 Max. Overcurrent Protection⁵ 15 15 15 15 Ship Weight (lbs) 98 116 123 120 ¹ Low-fire rate is 75% of high-fire rate. ² DOE AFUE based upon Isolated ombustion System (IS). ³ Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas ode NFPA 54/ANSI Z223.1 (in the USA) and the anada National Standard of anada, AN/SA B149.1 and AN/SA B142.2 (in anada). ⁴ Minimum ircuit Ampacity = (1.25 x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Refers to maximum recommended fuse or circuit breaker size; may use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VA, 60 Hz, single phase electrical supply. Gas Service onnection ½ FPT Important: It is required to size overcurrent protection device and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. SS- www.goodmanmfg.com 3

Dimensions Model A B 0603B** 17½ 16 0805** 21 19½ 0805D** 24½ 23" 1005** 21 19½ Minimum learances to ombustible Materials Sides Rear Front Bottom 1 0 3 6 1 1 = If placed on combustible floor, the floor MUST be wood ONLY. Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate USA and anadian codes: In the USA: the National Fuel Gas ode NFPA 54 / ANSI Z223.1 In anada: the anada National Standard of anada, AN/SA B149.1 and AN/SA B142.2 SW Vent B Top 4 www.goodmanmfg.com SS-

Airflow Data Model 0603B*B 0805*B 0805D*A (Med-Hi) 1005*B ¹ @ 0.5 ESP Motor Speed Tons A¹ (FM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water olumn) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 FM Rise FM Rise FM Rise FM Rise FM Rise FM FM FM T1 - Yellow 1.5 875 ---- 793 ---- 736 ---- 674 ---- 592 ---- 556 509 460 T2 - Red 2.0 1,032 43 965 46 914 49 861 ---- 810 ---- 756 712 659 T3 - Orange 2.5 1,217 37 1,153 39 1,098 40 1,051 42 1,009 44 964 918 877 T4 - Blue 3.0 1,365 33 1,313 34 1,268 35 1,221 36 1,172 38 1,129 1,086 1,054 T5 - Black 3.5 1,549 29 1,505 30 1,460 30 1,420 31 1,378 32 1,350 1,305 1,268 T1 - Yellow 2.5 1,176 50 1,115 53 1,044 57 983 60 929 64 863 810 750 T2 - Red 3.0 1,319 45 1,262 47 1,195 50 1,143 52 1,093 54 1,035 976 912 T3 - Orange 3.5 1,562 38 1,506 39 1,444 41 1,396 42 1,340 44 1,296 1,254 1,197 T4 - Blue 4.0 1,713 35 1,647 36 1,597 37 1,554 38 1,505 39 1,464 1,412 1,368 T5 - Black 5.0 1,919 --- 1,870 --- 1,837 --- 1,783 --- 1,727 --- 1,679 1,642 1,608 T1 - Yellow 3.5 1,524 39 1,479 40 1,439 41 1,388 43 1,343 44 1,281 1,243 1,190 T2 - Red 4.0 1,683 35 1,646 36 1,607 37 1,569 38 1,531 39 1,488 1,441 1,395 T3 - Orange 4.0 1,884 31 1,832 32 1,849 32 1,765 34 1,724 34 1,692 1,661 1,626 T4 - Blue 4.0 1,951 30 1,904 31 1,879 32 1,842 32 1,803 33 1,768 1,734 1,687 T5 - Black 5.0 2,036 29 2,010 29 1,977 30 1,947 30 1,923 31 1,888 1,844 1,816 T1 - Yellow 3.0 1,304 57 1,256 59 1,213 61 1,166 64 1,117 --- 1,042 994 948 T2 - Red 3.5 1,403 53 1,381 54 1,340 55 1,298 57 1,244 60 1,193 1,134 1,084 T3 - Orange 4.0 1,515 49 1,487 50 1,443 51 1,405 53 1,369 54 1,320 1,282 1,223 T4 - Blue 4.0 1,663 45 1,621 46 1,598 46 1,563 47 1,527 49 1,482 1,443 1,396 T5 - Black 5.0 1,795 41 1,749 42 1,728 43 1,694 44 1,669 44 1,632 1,605 1,554 Notes FM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, about 350-400 FM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPEIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular FM, while ESP at the FM will be lower. Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = ooling Temperature rise data is based on second-stage heat. First-stage heat is 75% of rise indicated above. SS- www.goodmanmfg.com 5

Wiring Diagram WARNING:DISONNET POWER BEFORE SERVIING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. XFMR (6) HUMIDIFIER GND INTEGRATED ONTROL MODULE 0 1 2 3 4 5 6 7 8 HOT SURFAE IGNITER GR STEADY ON =NORMAL OPERATION OFF 1FLASH = 10 11 7 8 4 5 1 2 24 VA HUMIDIFIER LINE NEUTRAL =ONTROL FAILURE 4FLASHES =OPEN HIGH LIMIT G R W Y 7FLASHES =LOW FLAME SIGNAL 24V 115V XFMR PRIMARY LIMIT BR ROLLOUT LIMITS (SINGLE ONTROL ON SOME MODELS) RAPID FLASHES =REVERSED 115 VA POLARITY/VERIFY GND FLAME SENSOR SYSTEM LOKOUT (RETRIES/REYLES EXEEDED) 2FLASHES =PRESSURE SWITH STUK LOSED 3FLASHES =PRESSURE SWITH STUK OPEN 12 9 6 3 5FLASHES =FLAME SENSE WITHOUT GAS VALVE 6FLASHES = OPEN ROLLOUT OR OPEN FUSE 2 1 DOOR SWITH SWITH LOATED IN BLOWER OMPARTMENT ON SOME MODELS AUTO 1STG 150 SE XFMR-H LINE-H FUSE SEE NOTE 6 INTEGRATED ONTROL MODULE FS EA-H PM HI 1 3 2 2STAGE GAS VALVE (HONEY WELL) 5MIN 2STG MODE 100SE 8FLASHES =HEK IGNITER OR IMPROPER GROUND BL OR BR 2NDSTGDLY HTOFFDLY BL BL DIAGNOSTI LED HI HEAT-H OOL-H LO HEAT-H PARK OR BL BR (N) IRULATOR BLOWER AUXILIARY LIMITS BR BL (MED HI) OR(MED) (MED LOW) 15PIN PLUG ON SOME MODELS INDUED DRAFT (HI) BLOWER OMPARTMENT BURNER OMPARTMENT NO BLOWER 24VA HUMIDIFIER PRESSURE SWITH (LOW) 24V THERMOSTAT ONNETIONS INTEGRATED ONTROL MODULE G Y W R TO MIRO XFMR (3) XFMR-H FP LINE-H DOOR SWITH IGN IND LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNTION TERMINAL INTERNAL TO INTEGRATED ONTROL GND (8) MV (9) MVH (12) MVL (2) PS(10) PSO (4) HLI (7) HLO (1) RO2 (11) RO1 (5) AUXILIARY LIMIT ONTROLS 2 HI M1 GAS VALVE MANUAL RESET ROLLOUT LIMIT ONTROL(S) (SINGLE ONTROL ON SOME MODELS) 24 VA OOL-H HI HEAT-H WARNING: DISONNET POWER BEFORE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L JUNTION BOX PLUG ONNETION EA-H 115 VA FLAME SENSOR HOT SURFAE IGNITER ID BLWR IRULATOR BLWR JUNTION BOX GND ID BLOWER PRESSURE SWITH NO 40 VA TRANSFORMER IR-N OVERURRENT PROTETION DEVIE LINE-N GND LINE H TO 115 VA/ 1/60HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE LO HEAT-H ELETRONI AIR LEANER N IGN-N IND-N EA-N FIELD SPLIE SWITH (TEMP.) SWITH (PRESS.) XFMR-N LINE-N EQUIPMENT GND FIELD GND AUTO RESET PRIMARY LIMIT ONTROL DISONNET IGNITER OVERURRENT PROT. DEVIE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. OLOR ODES: YELLOW OR ORANGE RPLE GR GREEN BLAK 0140F00658 REV. A PK PINK BR BROWN ITE BL BLUE GY GRAY RED NOTES: 1. SET HEAT ANTIIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BEUSED EN SERVIING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BEREPLAED WITH WIRING MATERIAL HAVING ATEMPERATURE RATING OF AT LEAST 105. USE OPPER ONDUTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BYINSTALLER TO MATH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE ORRET HEATING TEMPERATURE RISE AND THE ORRET OOLING FM. (SEE SPE SHEET FOR AIR FLOW HART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND ONFORM TON.E.. AND LOAL ODES. 6. TO REALL THE LAST 5FAULTS, MOST REENT TOLEAST REENT, DEPRESS SWITH FOR MORE THAN 2SEONDS ILE IN STANDBY(NO THERMOSTAT INTS). 6 www.goodmanmfg.com SS-

Wiring Diagram IRULATOR BLOWER ELETRONI AIR LEANER I NDUER HI HEAT LO HEAT OOL PARK IR NEU EA EA NEU IND K2 K2 K3 K3 K6 K1.0005 3M K4 FATORY JUMPER K5 FATORY JUMPER FP IGN GND MV MLV PS HLO HLI FLAME SENSOR PROBE IGNITOR HI OM PM HIGH LIMIT AUX LIMIT 2-STAGE GAS VALVE PRESSURE SWITH K7 PSO R RO2 RO1 TH XFMR HOT XFMR NEU TR Y G W ROLLOUT SWITH 24 VA OMPRESSOR ONTATOR OIL R Y G W THERMOSTAT Typical Schematic ** Model Furnaces WR 50M56-289 Integrated Ignition ontrol SS- www.goodmanmfg.com 7

Accessories Model Description LPM-06 ¹ HANG20 AFE18-60A LP onversion Kit (Springs & Orifice) High-Altitude Natural Gas Kit (4500+ Ft.) Fossil Fuel Kit ¹ Honeywell or White-Rodgers valves Minimum Filter Sizes Model # 0603B** 0805** 0805D** 1005** Filter Size (in²) (1) 16 x 25 (Side) or (1) 14 x 24 (Bottom) (1) 16 x 25 (Side or Bottom) ¹ (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2-16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2015 Goodman Manufacturing ompany, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-