Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Similar documents
CORE Protection Fire System Specification

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

CHAPTER 5: EXHAUST SYSTEMS

Kitchen Fire Suppression Systems Post-Event Analysis

NFPA 96, 2017 REVIEW SUMMARY

COMMERCIAL KITCHEN FIRE SAFETY

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

SECTION COMMERCIAL-KITCHEN HOODS

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

REQUIREMENTS FOR HOOD PLANS

2015 ICC Commercial Cooking Systems

Dear Concessionaire,

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

Kitchen Ventilation Hood Permit Application

IMC Significant Changes Summary Tier I

2012 ICC Commercial Kitchen Hoods

Osceola County Department of Fire Rescue and Emergency Medical Services

Types of Detection. Fusible Link Detection - Most Common

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

Ships and marine technology Fireextinguishing. of galley cooking equipment

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

XRRS Specification Fire Ready Hood

To expedite the plan review and inspection processes, please refer to the information below.

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

JADE RANGE LOG BROILER MODELS: JLB SERIES

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

R-102 RESTAURANT FIRE SUPPRESSION SYSTEM

MSYS 4490 AC Systems

Winnipeg Fire Department Fire Prevention Branch

Checklist For Building Inspection & Fire Safety

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Notable Changes in the Mechanical Codes

Owner s Guide Installation & Operation

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Installation. Professional Built-in Hoods

Comparative Matrix A Comparison of the NFPA 96 and ICC Standards and Codes with regard to Commercial Kitchen Systems

Use, Care, and Installation Guide

FIRE DEPARTMENT PERMIT GUIDELINES

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Chapter One Commercial Kitchen Fires

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

Variable Ventilation for the Kitchen:

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Low Wall Back Shelf Exhaust Canopy

DO NOT REMOVE THE MONITORS FOR SERVICE! COVER THEM WITH PLASTIC AND TAKE A PICTURE OF THE MONITORS COVERED.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

KITCHEN A104 CAFETERIA A103 RECEIVING WALK-IN FREEZER WALK-IN COOLER ENTRY EXIT EXIT COOKING PREP ENTRY WAREWASHING DRY STORAGE TRAY RETURN

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Mobile Vendors Bulletin

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

New Construction Fire Inspection Process

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNDER CABINET RANGE HOOD

Business License Pre-inspection Checklist

SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:

THE IDEAL SOLUTION FOR KITCHENS

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

FOOD PREPARATION WITHIN EXHIBITS

Ecolibrium. Kit and a bit UTS triumphs at the AIRAH Awards. ANNUAL AIRAH AWARDS THE OFFICIAL JOURNAL OF AIRAH FEBRUARY 2016 VOLUME 15.

Imperial Cal Products, Inc.

Sheetz Inc. Fire Protection Service Guidelines

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Installation Instructions Remote Blowers

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

2012 International Mechanical Code Significant Changes. About the Significant Changes

Ventless Operation Supplement GBF-D-VH

Integrated Ventilation System

Jacqueline Wilmot Fire Protection Engineer NFPA. Road Map for Mobile Food Truck Regulation

2012 INTERNATIONAL FUEL GAS CODE VENTS

Note: The event coordinator is responsible for compliance of all regulations.

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation

System Test Report CLEAN AGENT

Integrated Hood Liner

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

user manual Model #: BLZ-HOOD

Revolving Oven Gas Wood Model 140

Transcription:

FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed by the Fishers Fire Department. If NO, obtain plans and reschedule acceptance test. The installer has certified that the system has been installed in accordance with the approved plans and the manufacturer s listed installation and maintenance manual. The owner has been provided with a copy of the manufacturers listed installation and maintenance manual or listed owner s manual. HOOD INSTALLATION NO A Type I hood is installed in accordance with manufacturer s installation instructions. All seams, joints and penetrations of the hood enclosure that directs and captures grease-laden vapors and exhaust gases have a liquid tight continuous external weld or are sealed by labeled devices. Insulation materials other than electrical insulation has a flame spread rating of twenty-five (25) or less. The inside edge of the a canopy hood overhangs or extends a horizontal distance of not less than six (6) inches beyond the edge of the cooking surface on all exposed sides. Hood has a vertical distance between the lip of the canopy hood and the cooking surface does not exceed four (4) feet. n-canopy hoods shall be located a maximum of three (3) feet above the cooking surface with an overhang of three (3) inches on exposed ends. The front of the hood is set back a maximum of twelve (12) inches from the cooking surface. Filters are of a baffle-type. Mesh filters are not permitted. Filters are tight fitting and firmly held in place and installed at an angle not less than 45 degrees. Make-up air is provided at a rate to prevent negative pressure in the commercial cooking areas The exhaust duct is free of wiring or wiring systems. FFD-INSP-06-16 1

Hoods and ducts shall have a clearance of at least 18 inches from combustible materials, 3 inches to limited combustible materials, and 0 inches to noncombustible material. If these distances cannot be met then one of the exceptions in the Indiana Mechanical Code shall be met. FIRE SUPPRESSION SYSTEM System Manufacturer: System Model: TYPE OF SYSTEM: Wet Chemical Dry Chemical Wet Chemical w/ Water Spray Carbon Dioxide AMOUNT OF AGENT: LBS./GAL Number of Agent Containers Date Agent Mfg. PIPING: All penetrations in the ductwork are sealed by a liquid-tight continuous external weld or a labeled device. NOZZLES: Total Number of zzles Duct Plenum Surface Discharge nozzles are labeled for the purpose and are provided with caps to prevent entrance of grease vapors into piping. DETECTION DEVICES: Fusible links are positioned above each piece of equipment or groups of equipment protected by a single nozzle. Number of 360 degree links: Number of 500 degree links: EQUIPMENT INSTALLATION A Class K wet chemical fire extinguisher is provided no more than thirty (30)feet from the cooking area. Movable cooking equipment is provided with a means to ensure that it is correctly positioned in relation to the appliance discharge nozzle during cooking operations. List the equipment protected by the kitchen fire suppression system: Deep Fryers Grills Range Top (no. of burners) Char-broilers Upright Broiler Other: FFD-INSP-06-16 2

(draft equipment layout below) EXPELLANT: Carbon Dioxide Cartridge - wt. Pressurized Cylinder - PSI Nitrogen Cartridge - PSI Other - SHUTDOWN DEVICES System is equipped with an electrical shutdown device. Shunt Trip Breaker Contactor System is equipped with a fuel shutdown device. Mechanical Gas Valve Size Electric Gas Valve Size MANUAL RELEASE: Manual activation device is accessible and located not more than five (5) feet above the floor. Manual activation does not require a force of more than 40 lb or a movement of more than 14 inches to secure operation. Remote pulls are identified as to the hazard they protect. HYDROSTATIC TEST: Date of current hydrostatic test ACCEPTANCE TESTING FFD-INSP-06-16 3

Manual pull successfully activated system. Air pressure not less than twenty (20) PSI was used to test the pipe continuity. Test link was used to simulate mechanical system activation via detection device. Did all shutdown devices work during acceptance tests. The exhaust fan continued to run when the system was tripped. Make-up air shut down once fire suppression system activated. N/A The building is equipped with a fire alarm system. The extinguishing system activates the fire alarm system when operated. If, the alarm receipt location was notified before the system was tested. Name of the person at alarm receipt location: Was the alarm activation satisfactory. Smoke test confirms good air balance between the exhaust and supply airflow. System passed acceptance tests. System was left in service and fully operational. Remarks: Fishers FD Representative Date Fire Suppression System Installer Date FFD-INSP-06-16 4

Fire Department Dry/Wet Chemical &Powder System Installer Certification Building Permit #: Date: Business Name: Address: Owner/Occupant System Installer System Supplier Contact: Telephone #: Approved plans on site? Certification of System Installation: Complete this section after system is installed but prior to conducting operational acceptance tests. This system installation was inspected by (person) on and was found to comply with the installation requirements of: Please check: NFPA 17 17A 96 Indiana Fire Code, Indiana Building Code, Indiana Mechanical Code Manufacturer s Instruction/Specifications (provide) Other (specify & provide) Print Name: Signed: Organization: Date: Certification of System Operation: All operations features and functions of this system were tested by (person) on and found to be operating properly in accordance with the requirements of: Please check: NFPA 17 17A 96 Indiana Fire Code, Indiana Building Code, Indiana Mechanical Code FFD-INSP-06-16 5

Job Specs Manufacturer s Instructions (provide) Other (specify & provide) Print Name: Signed: Organization: Date: FFD-INSP-06-16 6