Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Similar documents
LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

Grüv Flare Regressed. Recessed Linear LED

Recessed LED Wall/Slot SAE 202

Max 4 Flush Lens RECESSED

Grüv Flare Regressed. Recessed Linear LED

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

RECESSED Spec Guide. up to 111 lm/w performance

RECESSED T-Bar & Drywall

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

RECESSED - WITH StepLens OPTION

Etch 2' x 2' Recessed LED

LUX PENDANT DIRECT/INDIRECT

SURFACE Spec Guide. up to 105 lm/w performance

Claude Indirect Wall WALL

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

M60 LED Recessed Wet Location

3.75 Gyro Shift Multiples Single Head

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Dimensions (111mm) (111mm) 3 (76mm)

Truss Surface SURFACE

BAS SFP22 Edge-lit LED Panel

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

FULL BLEED APPLICATION SHOT RENDERING

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Performance Chart Electrical Data

Evoke 2.9" HP. 2.9" Square Downlight

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Fino. Asymmetric Wall Mount Indirect LED

FPLHB - Fidelux Premier Linear Highbay

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Lumination LED Luminaires

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Hornet HP. Round Glass Downlight

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Luminaire Type: Catalog Number: Slot Trim (SLT) MYO Configurable 1, 2 & 3-Head Recessed Multiple Series

Evoke Square Downlight

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Evoke Square Downlight

Linea 1.5. Linear Direct Wall Wash LED

IHOL-6DR / IRD600 6 Gravity LED Downlight

Lumination LED Luminaires

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

Performance Chart Electrical Data

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

M100 LED Direct/Indirect

Essenza. Square Downlights

IHOL-4DR / IRD400 4 Gravity LED Downlight

Performance Chart Electrical Data

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

PROJECT DATE FLANGE FINISH

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

LHBXD LED Linear High Bay

Hornet HP. Semi-Recessed 4-Light Square Multiple

Essenza. Round Downlights

M100 My White LED Direct Tunable White

Catalog Number. Notes

Performance Chart Electrical Data

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Vaya Linear LP, White & Mono

Classix 6" 6" Round Lens Wall Wash

Evoke Round Downlight

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Murro HP. 3.5" Round Surface Canopy Wall Wash

Project Name. Date. Cat. Number. Type

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

l i g h t A B S O R B H

lumenalpha downlight Specification Sheet

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

RLN Recessed LED luminaire

Highbay Linear LED Series Flat Profile Design

TROFFER RETROFIT KIT (TRK)

Velato. Recessed Slot Adjustable Multiples

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

led HIGH CEILING 3 OUTPUT LEVELS LL1 - Low Output: 49W LL2 - Medium Output: 69W LL3 - High Output: 100W

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

Surface Mount Series Luminaires

DHL-LP-LED Low Profile LED Linear High/Low Bay

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

Catalog Number. Notes

Classix 6" 6" Round Lens Downlight

Hornet HP. Square Glass Downlight

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

LED FLAT PANEL EDGE LIT MLFP SERIES G2

Classix 6" 6" Round Lens Wall Wash

BeveLED Cylinder LBRP6 Surface

Evoke Square Adjustable C3M

Transcription:

Evolution EXWW Project Name Date Type RECESSED LINEAR WALL WASH LUMINAIRE 3-13/16 (96.8mm) 5-1/8 (130.2mm) Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing Highly reflective, die-formed white, painted steel reflector 5-year limited warranty covers LED, driver and fixture UL and cul listed. IC rated Approved for dry/damp location unless otherwise noted Maximum fixture weight is 15lbs (per 4ft fixture) Room-Side Maintenance for LED system Buy American Act compliant

Evolution 3 (72.6mm) 3 Wall Wash Recessed Linear Luminaire Project Name HOUSING pg. 3 CRI, CCT & OUTPUT pg. 4 LENGTH pg. 5 MOUNTING pg. 6 VOLTAGE pg. 7 DRIVER pg. 7 CIRCUITING pg. 8 BATTERY & EMERGENCY pg. 9 FINISH pg. 10 FIXTURE OPTIONS pg. 10 EV3WW Wall Wash EV3WW _27 30 2700K 3000K Example: 827HO is 8 = 80 CRI; 27 = 2700K; HO = High Output Individual Fixture - Continuous Row 2', 3', 4', 5', 6', 7', & 8' in 1' increments G1 G9 1 T-Bar 9/16 T-Bar U 1 Universal 120V _ (120 thru 277V) OL1 LH1 Osram Dimming Lutron Dimming _ 0-10V, 10% 1 E Single Emergency _ entire fixture 0 _B None # of Bodine 10W W Matte White QS Quick Ship 7/16 (11.1m) CP Chicago Plenum 3-13/16 (96.8m) _35 3500K FL Flanged 2 277V 5-1/8 (130.2mm) 11/16 (17.5m) N Night Light entire fixture _I # of Iota 10W GLR Internal Fast Blow Fuse _40 4000K NF Flangeless Date Type EV3WW- - - - - - - - W - QS CRI, CCT & Output CL Custom Lumens Length Mounting Voltage Driver Circuiting Battery & Emergency Example Part #: EV3WW-827-8-G1-U-OL1-1-0-W-QS CW Custom Watts Finish Fixture Options Details pg. 3 Lumen Outputs, 80 & 90 CRI pg. 4 More Options on pg. 5 Details on pg. 6 Details on pg. 7 Details on pg. 7 Details on pg. 8 More Options on pg. 9 Details on pg. 10 More Options on pg. 10 2 of 11

Evolution EV3WW- - - - - - - - - W QS Housing Extruded aluminum module with micro reflector for perfect wall wash illumination Clear lens and baffle are optional accessories. Specify in the Options section Wiring access available on bottom of housing WW Wall Wash HOUSING Photometrics Wall Wash Test # ITL82933 Catalog # EV3WW-840-4 Lumens 1406 lm Watts 24.1 W Efficacy 58 LPW 1042 782 521 261 Candela Distribution Vert Angle Horizontal Angle Luminance Data (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 0 22.5 45 67.5 90 45 19888 24775 38132 0 566 566 566 566 566 55 17529 20163 38110 5 793 731 567 434 371 65 15088 17640 38063 10 996 891 563 301 230 75 11620 14192 38811 15 1038 999 554 210 140 85 9643 10232 28436 20 903 1016 541 144 88 25 709 926 523 96 69 30 581 765 503 73 57 35 470 611 476 61 48 40 411 509 446 50 39 45 373 408 412 41 29 50 342 351 376 33 11 55 316 310 336 24 4 60 287 275 292 7 3 65 252 243 248 3 1 70 214 208 204 2 1 75 173 167 157 1 0 80 146 124 106 1 0 85 122 96 41 0 0 90 95 70 0 0 0 For all available IES files, please visit our website at pinnacle-ltg.com. Photometry testing in accordance to IESNA-LM-79-08 at an NVLAP accredited testing laboratory. Testing conducted at 25 C ambient conditions. 3 of 11

Evolution EV3WW- - - - - - - - - W QS CRI, CCT & Output 25ºC test environment. Lumen output has a margin of +/- 5%. All luminaire configurations tested in accordance with IES LM-79 Diodes tested in accordance with IES LM-80 Minimum lifetime greater than 60,000 hours Lifetime Projection L70 = 122,900 hours and L90 = 36,600 hours LED binned within MacAdam 3-Step Ellipses Specify either 80 or 90 CRI 80 CRI = R9 19 and 90 CRI = R9 61 Custom Output- Lumens OR Wattage CL _ Specify CRI, CCT and desired lumens (i.e. CL835700) Specify lumens between standard offering listed below. Lumens are specified per color temp CW _ Specify CRI, CCT and desired wattage (i.e. CW9407) Specify watts between standard offering listed below 80 CRI Color Output Watts Shielding WW Wall Wash Lumens LPW 830 3000K Standard 6.0 329 54.6 830HO 3000K High 10.3 511 49.7 835 3500K Standard 6.0 343 56.9 835HO 3500K High 10.3 534 52.0 840 4000K Standard 6.0 352 58.4 840HO 4000K High 10.3 548 53.3 90 CRI 927 2700K Standard 6.0 270 44.8 927HO 2700K High 10.3 420 40.9 930 3000K Standard 6.0 304 50.5 930HO 3000K High 10.3 471 45.8 935 3500K Standard 6.0 309 51.3 935HO 3500K High 10.3 481 46.8 940 4000K Standard 6.0 314 52.1 940HO 4000K High 10.3 489 47.6 CRI, CCT & OUTPUT LED Product Partner See Lighting Facts Spec Sheet for tables Not all products are Lighting Facts listed 4 of 11

Length Evolution EV3WW- - - - - - - - - W QS All individual units cannot be joined, end trims are factory installed and cannot be removed Continuous Rows are made up of even and odd length fixtures; designed to fall on-grid Choose fixture length for Individual or Continuous Row length 2 3 4 5 6 7 8 _ Individual Fixture Individual Fixture Individual Fixture Individual Fixture Individual Fixture Individual Fixture Individual Fixture Continuous Run 23 (584.2mm) Specify nominal overall row length 35 (889mm) to the nearest foot. 47 (1193.8mm) (Example: 16 run is comprised of 59 (1498.6mm) 96 +95 units.) 71 (1803.4mm) 83 (2108.2mm) 95 (2413mm) Specify to the 1 LENGTH Connection Detail Incorporating biscuits and screws not only create a secure joint but also aid in fixture alignment At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid Insert screws through the bracket into the grid to secure Biscuit Screws 5 of 11

Evolution EV3WW- - - - - - - - - W QS Mounting 4 (101.6mm) Grid center to center spacing 5-1/8 (130.2mm) Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall on-grid) Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid) Designed to be mounted facing wall between 12-18 from wall. Optimal performance being at 18 off wall Individual units cannot be joined, end trims are factory installed and cannot be removed Designed to install into acoustical grid and inaccessible ceilings Grid retention brackets integral to housing and require mechanical attachment. Each housing contains 4 grid retention brackets Tie off fixture to structure with retention wires (by others) NF and NFN to be utilized for metal pan or millwork ceiling Approved for dry/damp location unless otherwise noted Maximum fixture weight is 15lbs (per 4 fixture) G1G Individual Unit G9G GSG FLF NFN G1 Continuous Run or Pattern G9 GS FL NF 1" (15/16 ) T-Bar 9/16 T-Bar For tegular tile installations, fixture position will not be flush to the bottom of the tile Bolt Slot & 9/16 T-Bar For 9/16 installations with tegular tile, fixture position will be flush to the bottom of the tile Exposed Standard 1/2 Flange Detail Metal Pan or Millwork MOUNTING Standard Tile Standard Tile Standard Tile 6 of 11

Voltage Evolution EV3WW- - - - - - - - - W QS Some EVL configurations will not accommodate all voltage options; consult with factory U Universal 120 to 277 volt 1 120 volt 2 277 volt Driver Standard Driver Option = OL1 Electronic driver, Power factor is >0.9 with a THD <20%. Driver Lifetime: 50,000 hours at 25 C ambient operating conditions Ambient operating range: -20 F/-30 C to 83 F/28 C OL1 Osram 0-10v, 10% Standard driver option LH1 Lutron Hi-lume EcoSystem, 1% Soft on, Fade-to-Black Lutron-LDE1 VOLTAGE DRIVER 7 of 11

How to specify Circuiting, Battery and Emergency Evolution EV3WW- - - - - - - - - W QS 1 2 3 Circuiting Choose from the circuiting options below. Battery If Required Choose a battery from the options on the next page. Indicate quantity. Emergency If Required Choose emergency from the options on the next page. Indicate quantity. Circuiting 1 Select fixture circuiting from options below Some EV3 configurations will not accommodate all circuiting options; consult with factory 1 Single Circuit E Emergency Circuit only Entire fixture is on Emergency Circuit, includes dimming control N Night Light Circuit only Entire fixture is on Night Light Circuit, includes dimming control CIRCUITING 8 of 11

Battery and/or Emergency 2 + 3 Evolution EV3WW- - - - - - - - - W QS Battery and emergency section options are available in addition to fixture circuit Select battery and emergency section options below; factory shop drawing required Some EVL configurations will not accommodate all circuiting options, consult with factory 0 No battery or specific emergency section required Battery Select battery section type if required, indicate total QTY 90 minute battery runtime; test button is remote to fixture and requires an additional drop No battery option available for 2 lengths Entire fixture housing is on battery for lengths up to 5 Half of fixture is on battery for 6, 7 or 8 housing lengths 0 No battery _B Bodine 10w Integral CEC Listed _I Iota 10w Integral For Approximate Battery Lumen Output Multiply battery wattage X fixture LPW shown on Lumen Table 92.3 (LPW) x 10 (watts) = 923 battery lumen output Emergency Select emergency section type if required, indicate total QTY Combine battery and emergency section ordering codes if both options are selected _E Emergency circuit section Can be combined with circuit option 1 or M only; not required with circuit option E or N _N Night Light circuit section Can be combined with circuit option 1 M only; not required with circuit option E or N BATTERY & EMERGENCY Battery OR Emergency Ordering Examples Single circuit, 10w Integral Battery : 1-1B Emergency only, 10w Integral Battery : E-1B Single circuit, GTD required : 1-1G Combination Section Ordering Examples Single circuit, (1) 10w battery, (1) emergency section : 1-1B1E Multi circuit, (2) 10w battery, (2) emergency sections : M-2B2E Single circuit, (1) night light section : 1-1N 9 of 11

Finish Evolution EV3WW- - - - - - - - - W QS Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish; consult factory for chip of standard paint finishes Selecting a fixture finish other than white may impact lumen output. Consult factory for more information W White Fixture Options Additional options to enhance the fixture and finish of the product QS Quick Ship Must be specified in the part number in order to qualify for Quick Ship. All lengths and continuous rows up to 1,000 ft OR 150 individual fixtures. Consult factory for larger projects. CP Chicago Plenum All hole openings are covered on plenum side GLR Internal Fast Blow Fuse 3A FINISH FIXTURE OPTIONS 10 of 11

Evolution Approvals & Certifications Construction: Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective die-formed white painted steel reflector. Shielding: Diffuse snap-in acrylic lens, removable for maintenance. Mounting: Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid). Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions. LED: 25 C test environment. Lumen output/wattage has a margin of +/- 5%. All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. Minimum lifetime greater than 60,000 hours. Lifetime Projection L70 = 125,600 hours and L90 = 37,400 hours. MacAdam 3-Step Ellipses. Not all products are Lighting Facts listed. For all available IES files, please visit our website at pinnacle-ltg.com. CRI, CCT & Lumen Output: Two lumen packages available. Standard and High (HO). Custom outputs are available. Specify custom lumens or watts between standard offering listed on CRI, CCT & Output page. 80 CRI is available for 3000K, 3500K, and 4000K. 90 CRI is available for 2700K, 3000K, 3500K, and 4000K. 80 CRI = R9 19 and 90 CRI = R9 61. Voltage: Universal (U), 120 volt (1) and 277 volt (2). Some Evolution configurations will not accommodate all voltage options; consult with factory. Driver: Standard Driver Option is Osram 0-10V, 10% = OL1. Electronic driver, Power factor is >0.9 with a THD <20%. Driver Lifetime: 50,000 hours at 25 C ambient operating conditions. Ambient operating range: -20 F/-30 C to 83 F/28 C. Circuiting: Select from single circuit (1), Emergency circuit (E) or Night Light circuit (N). Some Evolution configurations will not accommodate all circuiting options; consult with factory. Battery & Emergency: Select battery or emergency options if required. If battery or emergency option is not required, enter 0. Battery duration is 90 minutes as standard. Test button is integral to fixture. Finish: Standard powder-coat textured white is available on quickship program Labels: UL and cul Listed. Standard and HO lumen packages are IC Rated, approved for dry/damp location unless otherwise noted. Buy American Act Compliant Warranty: Evolution LED offered with a 5-year limited warranty. Covers LED, driver and fixture. 11 of 11