OilSET-1000 (12 VDC)

Similar documents
OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET Installation and Operating Instructions. Level switch for one sensor

AND INSTALLATION MANUAL

SolarSET GSM SolarSET GSM with a Beacon

Operating Instructions

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Labkotec automatic warning devices for separators protecting the environment

Inductive slot sensor

DB5 Intrinsically Safe Sounder Type DB-5

LevelSET S GSM Functionalities Instructions for Commissioning and Use

Snifter ATEX22 VERSION. User Manual. Distributor

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

INTRINSICALLY SAFE S314X AND S315X

Technical Data. Dimensions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

4) Intrinsic Safety Certification

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OPTIBAR P 1010/2010 C Supplementary instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

PEPPERL+FUCHS GmbH

Alarm system For oil-water separator

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

MANUAL Oil Level Sensor

OPTIWAVE X500 Supplementary Instructions

IECEx Certificate of Conformity

Technical Data. General specifications. Rated operating distance s n 5 mm

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

User s Manual YTA610 and YTA710 NEPSI Certification

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Technical Data. Dimensions

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Tank Gauging System Special Safety Instruction

PROTECT SRB 200EXi-1A

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

MANUAL Overflow sensor NVF-104/34-PF

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Intrinsically Safe Solutions

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Labkotec Ice Detector

Operating Manual MS220KA and MSR220KA

Operating Instructions Edition 02/2007

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX)

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Quick Start Manual July pointek CLS100

EUROFLAT SERIES TYPES C... S... M...

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Installationsmanual GWSL1100/2100, GWML3100

VERSAFLOW VORTEX Supplementary instructions

Safety instructions VEGAPULS 64

EU DECLARATION OF CONFORMITY

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

14300 MAINS SEPARATOR ALARM MANUAL

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Snifter. User Manual. Distributor

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

IECEx Certificate of Conformity

SEPARIX. Technical Documentation. SEPARIX-C/-T and SEPARIX-Control CT. Edition: Version: 5 Art. no.:

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Operating Manual MS220DA

OPTIBAR DP 7060 Supplementary Instructions

TX6831 Data Sheet. Features. Benefits

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

USER GUIDE FOR GASSONIC SURVEYOR ULTRASONIC GAS LEAK DETECTOR

U L T R A S O N I C G A S L E A K D E T E C T O R

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Gas cylinder scale Model GCS-1

Intrinsically Safe Flame Detector Installation Guide

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Transcription:

Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009 Labkotec Oy We reserve the right for changes without notice

TABLE OF CONTENTS 1 GENERAL... 3 2 INSTALLTION... 4 2.1 OilSET-1000 (12 VDC) control unit... 4 2.2 SET DM/3 probe... 5 2.3 Cabling... 5 2.4 Cable extension using junction box... 5 3 OPERATION AND SETTINGS... 6 3.1 Operation... 6 3.2 Factory settings... 8 4 TROUBLE-SHOOTING... 9 5 REPAIR AND SERVICE... 10 6 SAFETY INSTRUCTIONS... 10 7 TECHNICAL AND SAFETY DATA... 11 SYMBOLS Warning / Attention Pay special attention to installations at explosive atmospheres Copyright 2009 Labkotec Oy 2/11 We reserve the right for changes without notice

1 GENERAL Labko OilSET-1000 (12 VDC) is a DC-powered alarm device for monitoring the thickness of the oil layer accumulating in an oil separator. Depending on the order, the delivery consists of OilSET- 1000 (12 VDC) control unit, SET DM/3 probe, junction box and installation supplies. Figure 1. OilSET-1000 (12 VDC) Oil separator alarm system SET DM/3 probe is installed into the light liquid storage chamber and gives an alarm when the chamber is filled to a pre-determined degree. The probe is normally immersed in water. The function is based on the measurement of the electrical conductivity of the surrounding liquid water conducts electricity much better than oil. Oil separator is regarded as potentially explosive (Ex) area. SET DM/3 probe can be installed in a zone 0, 1 or 2 potentially explosive area but the control unit must be mounted in a safe area. The LED indicators, push buttons and interfaces of the OilSET-1000 (12 VDC) control unit are described in figure 2. Figure 2. OilSET-1000 (12 VDC) control unit - features Copyright 2009 Labkotec Oy 3/11 We reserve the right for changes without notice

2 INSTALLTION 2.1 OilSET-1000 (12 VDC) control unit OilSET-1000 (12VDC) control unit can be wall-mounted. The mounting holes are located in the base plate of the enclosure, beneath the mounting holes of the front cover. The connectors of the external conductors are isolated by separating plates. The plates must not be removed. The plate covering the connectors must be installed back after executing cable connections. The cover of the enclosure must be tightened so, that the edges touch the base frame. Only then do the push buttons function properly and the enclosure is tight. Before installation, please read the safety instructions in chapter 6! Figure 3. OilSET-1000 (12 VDC) alarm device installation. Copyright 2009 Labkotec Oy 4/11 We reserve the right for changes without notice

2.2 SET DM/3 probe 2.3 Cabling SET DM/3 probe should be installed as described in figure 3. The probe gives an alarm earliest when the upper electrode is in oil and latest when the probe is totally immersed in a non-conductive liquid - in other words, it is totally away from the water. Please check the correct installation depth also from the instructions of the oil separator. When probe cable extension is not necessary, connect the wires and shield as described in figure 3. Resistance of the wire used for equipotential grounding must be less than 1 Ω and cross section at least 4 mm² or 2 x 1.5 mm². 2.4 Cable extension using junction box If the probe cable must be extended, it can be done with the cable junction box. The cabling between the OilSET-1000 (12 VDC) control unit and the junction box should be done with a shielded twisted pair instrument cable. LJB2 junction box enables cable extension in potentially explosive atmospheres. The junction box can be installed inside the separator by mounting it to the separator or with a separate mounting hook. OilSET-1000 (12 VDC) control unit SHD Channel 1 + - 9 10 11 Extension cable To equipotential ground Shields of extension cable JUNCTION BOX LJB2-78-83 3 1 2 To equipotential ground Shield of probe cable All shields and excess wires to be connected to the same point. SET DM/3 PROBE Figure 4. Cabling with a junction box for cable extension. Copyright 2009 Labkotec Oy 5/11 We reserve the right for changes without notice

In the example in figure 4 the shields and excess wires have been connected to the same point in galvanic contact with metallic frame of the junction box. This point can be connected to equipotential ground thru the ground terminal. Other components of the system that need to be grounded can also be connected to the same ground terminal. The wire used for equipotential grounding must be min. 2.5 mm² mechanically protected or, when not protected, the minimum cross section is 4 mm². OilSET-1000 (12 VDC) control unit is connected to equipotential ground thru its own terminal and resistance of the wire must be less than 1 Ω and cross section at least 4 mm² or 2 x 1.5 mm². Please make sure, that the probe and cable between control unit and the probe do not exceed the maximum allowed electrical parameters see chapter 7 Technical data. Detailed cabling instructions can also be found in the document SET DM/3. Junction box of type LJB2 includes light alloy parts. When installing in explosive atmosphere, make sure, that the junction box is located so, that it can not be mechanically damaged or it will not be exposed to external impacts, friction etc. causing ignition of sparks. Make sure, that the junction box is closed properly. 3 OPERATION AND SETTINGS Functionality test 3.1 Operation Normal mode no alarms Oil alarm The OilSET-1000 (12 VDC) alarm device is initialized at the factory. The operation of the alarm device should be checked always after the installation. 1. Immerse the probe into water. The device should be in normal mode. 2. Lift the probe up in air or oil. An Oil alarm should be generated (see chapter 3.1 for more detailed description). 3. Immerse the probe back into water. The alarm should go off after a delay of 5 sec. Clean up the probe if necessary before placing it back into the oil separator. A more detailed description of the operation is provided in chapter 3.1. If the operation is not as described here, check the factory settings (chapter 3.2.) or contact a representative of the manufacturer. The operation of a factory-initialized OilSET-1000 (12 VDC) is described in this chapter. SET DM/3 probe is totally immersed in water. Mains LED indicator is on. Other LED indicators are off. Relays 1 and 2 are energized. SET DM/3 probe is immersed in oil. (The probe gives an alarm earliest when the upper electrode is in oil and latest when the probe is totally immersed in a non-conductive liquid, in other words it is totally away from the water.) Mains LED indicator is on. Oil Alarm LED indicator is on. Buzzer on after 5 sec delay. Relays de-energize after 5 sec delay. (Note. The same alarm takes place when SET DM/3 probe is in the air.) Copyright 2009 Labkotec Oy 6/11 We reserve the right for changes without notice

After removal of an alarm, the Oil Alarm LED indicator and buzzer will be off, and relays will be energized after a fixed delay of 5 sec. Fault alarm Reset of an alarm Probe cable break, short circuit or a broken probe, i.e. too low or too high probe signal current. Mains LED indicator is on. Probe circuit Fault LED indicator is on after 5 sec delay. Buzzer is on after 5 sec delay. The relays de-energize after 5 sec delay. When pressing the Reset push button. Buzzer will go off. Relay 1 energizes. Relay 2 will stay de-energized until the actual alarm or fault is off. TEST FUNCTION Test function provides an artificial alarm, which can be used to test the function of the OilSET-1000 (12 VDC) alarm device and the function of other equipment, which are connected to OilSET-1000 (12 VDC) via its relays. Attention! Before pressing the Test button, make sure that the change of relay status does not cause hazards elsewhere! Normal situation Alarm on Fault alarm on When pressing the Test push button: Oil Alarm and Fault LED indicators are immediately on. Buzzer is immediately on. Relays de-energize after 2 sec of continuous pressing. When the Test push button is released: LED indicators and buzzer go immediately off. Relays energize immediately. When pressing the Test push button: Fault LED indicator is immediately on. Oil Alarm LED indicator remains on. Buzzer remains on. If it has been reset earlier, it will return to be on. If relay 1 was already reset, it will de-energize again after 2 sec. of continuous pressing. Test will not affect relay 2, because it is already in alarm status. When the Test push button is released: The device returns without delay to the preceding status. When pressing the Test push button: The device does not react to the test at all. Copyright 2009 Labkotec Oy 7/11 We reserve the right for changes without notice

3.2 Factory settings If the operation of OilSET-1000 (12 VDC) is not as described in the previous chapter, check that the device settings are as in figure 5. Change the settings according to the following instructions if needed. The following tasks must only be executed by a person with proper education and knowledge of Ex-i devices. We recommend, that when altering the settings the supply voltage is off or the device is initialized before the installation is executed. Figure 5. Factory settings The settings are made with switches (MODE and DELAY) and potentiometer (SENSITIVITY) located in the upper printed circuit board, and the jumper located in the lower board (figure 5). In figure 5, the switches are as set in the factory. Switch S2 is used to set the operational delay of the control unit. When the switch is in low position, relays operate and buzzer is on after 5 seconds after the level has reached the trigger level, and if the level still remains on the same side of the trigger level. When the switch is in high position, the delay is 30 seconds. Delays are operational in both directions (energizing, de-energizing). Alarm LED follows the probe current value and trigger level without delay. Fault alarm takes place after a fixed delay of 5 sec. Copyright 2009 Labkotec Oy 8/11 We reserve the right for changes without notice

4 TROUBLE-SHOOTING Problem: Possible reason: To do: MAINS ON LED indicator is off Supply voltage is too low or the fuse is blown or MAINS ON LED indicator is faulty. 1. Check the fuse. 2. Measure the voltage between poles - and +. It should be 11 17 VDC. Problem: Possible reason: To do: No alarm when probe in oil or air, or the alarm will not go off The SENSITIVITY setting is wrong in the control unit (see figure 6), or probe is dirty. 1. Clean-up the probe and lift it up in the air or immerse it into oil. 2. Turn the SENSITIVITY potentiometer slowly anticlockwise until the probe gives an alarm. 3. Immerse the probe into water and wait until the alarm goes off. If the alarm does not go off, turn the potentiometer slowly clockwise until the alarm goes off. 4. Lift the probe up in the air or oil. The probe should give an alarm again. Problem: Possible reason: To do: FAULT LED indicator is on Current in probe circuit too low (cable break) or too high (cable in short circuit). The probe might also be broken. 1. Make sure, that the probe cable has been connected correctly to the OilSET- 1000 (12 VDC) control unit. See probe specific instructions. 2. Measure the voltage separately between the poles 10 and 11. The voltages should be between 10,3.11,8 V. 3. If the voltage is correct, measure the probe current. Do as follows: 3.1 Disconnect probe s [+] wire from probe connector (pole 10). 3.2 Measure short circuit current between [+] and [-] poles. 3.3 Connect ma-meter as in figure 6. Make a comparison to the values in Table 1. 3.4 Connect the wire back to the connector. If the problem can not be solved with the above instructions, please contact Labkotec Oy s local distributor or Labkotec Oy s service. Attention! If the probe is located in an explosive atmosphere, the multimeter must be Exi-approved! Figure 6. Probe current measurement Shortcircuit Probe in the air Probe in oil (εr. 2) Probe in the water Factory setting for alarm point Table 1. Probe currents SET DM/3, channel 1 Poles 10 [+] ja 11 [-] 20 ma 24 ma 9 10 ma 9 10 ma 2 3 ma approx. 6.5 ma Copyright 2009 Labkotec Oy 9/11 We reserve the right for changes without notice

5 REPAIR AND SERVICE The probe should be cleaned and the operation should also be tested when emptying the oil storage chamber or at least once every six months. The easiest way to check the operation is to lift the probe up in the air and to put it back to the separator. The operation is described in chapter 3. For cleaning, a mild detergent (e.g. washing-up liquid) and a scrubbing brush can be used. The mains fuse (marked 315 mat) can be changed to another glass tube fuse 5 x 20 mm / 315 mat complying EN 60127-2/3. Any other repair and service works on the device may be carried out only by a person who has received training in Ex-i devices and is authorized by the manufacturer. In case of queries, please contact Labkotec Oy s service: labkotec.service@labkotec.fi. 6 SAFETY INSTRUCTIONS OilSET-1000 (12 VDC) control unit must not be installed in potentially explosive atmosphere. Probes connected to it may be installed in zone 0, 1 or 2 potentially explosive atmospheres. In case of installations in explosive atmospheres the national requirements and relevant standards as EN 50039 and/or EN 60079-14 must be taken into account. If electrostatic discharges can cause hazards in the operating environment, the device must be connected into equipotential ground according to requirements with regards to explosive atmospheres. Equipotential grounding is made by connecting all conductive parts into same potential e.g. at the cable junction box. Equipotential ground must be earthed. When executing service, inspection and repair in explosive atmosphere, the rules in standards EN 60079-17 and EN 60079-19 about instructions of Ex-devices must be obeyed. Copyright 2009 Labkotec Oy 10/11 We reserve the right for changes without notice

7 TECHNICAL AND SAFETY DATA OilSET-1000 (12 VDC) control unit Dimensions 175 mm x 125 mm x 75 mm (L x H x D) Enclosure IP 65, material polycarbonate Ambient temperature -25 ºC +50 ºC Supply voltage Power consumption Probes Max. impedance of the current loop between the control unit and a probe Relay outputs EMC Emission Immunity 11 17 VDC Fuse 5 x 20 mm 315 mat (EN 60127-2/3) The device is not equipped with a power switch Max 1,2 VA Typical (no alarms) 0,9 VA One Labkotec SET probe (SET DM/3) 75 Ω. Two potential-free relay outputs 250 V, 5 A, 100 VA Operational delay 5 sec or 30 sec. Relays de-energize at trigger point. Operation mode selectable for increasing or decreasing level. EN 61000-6-3 EN 61000-6-2 SET DM/3 probe Principle of operation Enclosure Measurement of conductivity Ambient temperature -20 ºC +70 ºC Supply voltage IP68, materials: AISI 316 and PVC Approx. 12 VDC from SET control unit Cable Fixed oil resistant PVC cable 3 x 0,5 mm 2, standard length 5 m. EMC Ex-classification Emission Immunity EN 50081-1 EN 50082-1 II 1 G EEx ia IIA T4 VTT 02 ATEX 012X Electrical parameters U i = 16,5 V I i = 80 ma P i = 330 mw C i = 700 pf L i = 10 μh Special conditions concerning Ex-classification (X): - Ambient temperature -20 ºC +70 ºC - Shielded probe cable shall be connected to equipotential ground - If probe cable have to be extended, please use LJB2-78-83 junction box. The junction box shall also be connected to equipotential ground. Ex-classification Special conditions (X) Electrical parameters Characteristic curve of the output voltage is trapezoidal II (1) G [EEx ia] IIC VTT 04 ATEX 031X (Ta = -25 C +50 C) U m = 23 V U o = 14,7 V I o = 55 ma P o = 297 mw R = 404 Ω See table 2. Due to non-linear characteristics of the probe voltage, the interaction of both, capacitance and inductance, must be taken into account. The table below indicates the connecting values in explosion groups IIC and IIB. In explosion group IIA the values of the group IIB can be applied. Max. permissible value Combined Co and Lo Co Lo Co Lo II C 608nF 10 mh 568nF 458 nf 388 nf 328 nf 258 nf 0,15 mh 0,5 mh 1,0 mh 2,0 mh 5,0 mh II B 3,84μF 30 mh 3,5 µf 3,1 µf 2,4 µf 1,9 µf 1,6 µf 0,15 mh 0,5 mh 1,0 mh 2,0 mh 5,0 mh Ø 25 mm 214 mm Figure 7. Dimensional drawing of SET DM/3 probe L o /R o = 116,5 µh/ω (IIC) and 466 µh/ω (IIB) Table 2. OilSET-1000 electrical parameters Copyright 2009 Labkotec Oy 11/11 We reserve the right for changes without notice