PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

Similar documents
PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-107

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 099

PRILOGA K AKREDITACUSKI LISTINI Annex to the accreditation certificate

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-004

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-047

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-032

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Metode preskušanja cementa - 1. del: Določanje trdnosti Methods of testing cement - Part 1: Determination of strength

Glenside Environmental Services Ltd

SEZNAM AKREDITIRANIH METOD V PRESKUSNEM LABORATORIJU IRMA (LP-008) / LIST OF ACCREDITED METHODS IN TESTING LABORATORY IRMA (LP-008)

LME OPREMA I AKREDITIRANE METODE ISPITIVNJA

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Seznam akreditiranih metod. Laboratorij za toplotno zaščito in akustiko

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

INTERNATIONAL STANDARD

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

GUIDELINES FOR DESCRIBING THE ACCREDITATION SCOPES OF TESTING LABORATORIES

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

OBSEG METOD S FLEKSIBILNIM OBSEGOM AKREDITACIJE. Oddelek za kemijske analize živil, vod in drugih vzorcev okolja, Gosposvetska ulica 12, 4000 Kranj

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

gas monitoring system

portable gas analyser

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ACTIVITIES OF THE MEASURING GROUP

This document is a preview generated by EVS

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Complete Gas Analysis

Applied Techno Systems

Technical manual 2G-TA 04 - Gas


Certificate: _01 / 2 February 2015

portable gas analyser

Iesf Report l't March 2010

Rol van ISSeP als sectoraal operator

Chemistry Instrumental Analysis Lecture 29. Chem 4631

PREDICTING GASEOUS AIR CLEANER PERFORMANCE IN THE FIELD

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Laboratorija za ispitivanje građevinskih materijala MMLab d.o.o. Kotor Lasta Grbaljska bb, Kotor

Certificate: _01 / 19 August 2011

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

CERTIFICATE of Product Conformity (QAL1 )

CONFIRMATION of Product Conformity (QAL1)

P R O D U C T D ATA S H E E T

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Monitores Personales. Personal Monitor

PRODUCT CONFORMITY CERTIFICATE

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti.

d. Portable water heaters used exclusively for underwater diving operations.

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Certificate: / 29 April 2014

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Micro III (Models G203, G203S, and G213) Operation Manual

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

_03 / 28 July 2015

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Građevinski laboratorij d.o.o. Borongajska cesta 84, HR Zagreb Laboratorij Sesvete Slatinska 7, HR Sesvete

INTERNATIONAL STANDARD

This document is a preview generated by EVS

GAS DETECTOR ST400EC PART.NO

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Fire fighting Questions

CERTIFICATE of Product Conformity (QAL1 )

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

COMMISSION REGULATION (EU) No /.. of XXX

BULGARIAN ACCREDITATION SERVICES ACCREDITED ACCORDING TO BDS EN/ISO 17020:2005

3M Oldham OLCT 100. Description. Fixed Gas Detector

Monitoring Flammable Vapors and Gases in Industrial Processes

PRODUCT CONFORMITY CERTIFICATE

Review Fire Test Report

ISO INTERNATIONAL STANDARD

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

GAS ANALYSIS / DETECTION Gas Detector

IMO Resolution MSC 61(67): Annex 1: Part 2

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

FACILITY PROFILE ARBEC FOREST PRODUCTS INC. PRODUITS FORESTIERS ARBEC INC. Oriented Strand Board Mill Miramichi, N.B. Prepared by:

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

PROPOSED October 15, 2013

Transcription:

Reg. št. 1 Ref No.: 3151-0156/10-0004 Datum izdaje 1 /ssued on: 29. oktober 2012 Zamenjuje izdajo z dne 1 Rep/aces Annex dated: 18. september 2012 spletni strani SA, www.slo-akreditacija.si Information on current accreditation status is available at the SA website, www.slo-akreditacija.si PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate 1 AKREDITIRANI ORGAN 1 Accredited body RACI d.o.o. Tehnološki park 24, 1000 Ljubljana Merilni laboratorij 2 STANDARD SIST EN ISO/IEC 17025:2005 3 OBSEG AKREDITACIJE 1 Scope of accreditation V okviru te akreditacijske listine Slovenska akreditacija priznava akreditiranemu organu usposobljenost za opravljanje naslednjih dejavnosti: 1 SA hereby acknowledges the accredited body as being competent for performing the fol/owing activities: 3.1 Skrajšan opis obsega akreditacije 1 A short description of the scope Področja preskuša nja glede na vrsto preskušanja 1 Testing fields with reference to the type of test: fizikalno preskušanje 1 physica/ testing vzorčenje 1 sampling kemija 1 chemistry 0 8 05-31 * Izdaja 5 Stran 1 od 7

Datum izdaje 1/ssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Rep/aces Annex dated 18. september 2012 Information on current accreditation status is availab/e at www.slo-akreditacija.si Področja preskušanja glede na vrsto preskušanca 1 Testing fie/ds with reference to the type of test it em: okolje in vzorci iz okolja (viri emisij snovi) 1 environmnet and samp/es from the environmnet (sources of emissions of substances) 0805-31 * Izdaja 5 Stran 2 od 7

Datum izdaje 1/ssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Rep/aces Annex dated 18. september 2012 3.2 Podroben opis obsega akreditacija 1 Detai/ed scope of accreditation 3.2.1 Merilni laboratorij, Tehnološki park 24, Ljubljana Tabela 1 1 Table 1,.. ) Področja preskušanja glede na vrsto preskušanja: fizikalno preskuša nje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (vi~i emisij snovi) 1 Testing fie/ds with reference to the type of test item: environmnet and sam ples from the enironment (sources of emissions of substances) Št. preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Tltle of standard or non- and eventua/ relations to other standards or methods 1. SIST ISO 10396:1996 Emisije nepremičnih virov - Vzorčenje za plini avtomatično določanje plinskih koncentracij Stationary source emissions - Sampling for the automated determination of gas concentrations 2. SIST ISO 10780:1996 Emisije nepremičnih virov - Meritev hitrosti in (5-50) m/s plini volumenskega pretoka plinskih tokov v odvod nikih Stationary source emissions - Measurement of velocity and vo/ume flowrate of gas streams in ducts 3. DP07, 2009 Meritev hitrosti plinskih tokov v odvod nikih s (0,5-60) m/s plini interna metoda krilnim anemometrom ln-house method Measurment of velocity of gas streams in ducts with vane anemometer 4. SIST ISO 12039:2002 Emisije nepremičnih virov- Določevanje CO: (1-50/1000) ~-tili plini ogljikovega monoksida, ogljikovega dioksida in CO: (0,2-10/50) % kisika - Delovne karakteristike in kalibracija COz: (0,2-10/50) % avtomatskih merilnih sistemov Oz: (1-10/1 000) ~-tili Oz: (0,01-1/1 OO) % carbon monoxide, carbon dioxide and oxygen - Performance characteristics and ca/ibration of automated measuring systems 5. SIST EN 15058:2006 Emisije nepremičnih virov- Referenčna metoda CO: (1-50/500) ~-tili plini določevanja ogljikovega monoksida z nedisperzivno infrardečo metodo Stationary source emissions - Reference method for determination of carbon monoxide in emission by means of the non-dispersive infrared method 6. SIST EN 14789:2005 Emisije nepremičnih virov- Določevanje Oz : (0,02-2/100)% plini volumske koncentracije kisika (Oz)- Referenčna metoda- Paramagnetizem; vo/ume concentration of oxygen (02) - Reference method- Paramagnetism 0805-31 * Izdaja 5 Stran 3 od 7

Datum izdaje llssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Replaces Annex dated 18. september 2012 Information on current accreditation status is avai/able at www.slo-akreditacija.si l\ip obsega: fiksni 1 Type of scope: fixed Področja preskušanja glede na vrsto preskušanja: fizikalno preskušanje; vzorčenje; kemija 1 Testing 'fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the type of test item: environmnet and sam ples from the enironment (sources of emissions of substances) Št. preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Tltle of standard or non- and eventual relations to other standards or methods testing (where relevant) 7. SIST ISO 10849:1996 Emisije nepremičnih virov - Ugotavljanje masne NO: (4-200/2000) ~1/1 plini koncentracije dušikovih oksidov- Delovne karakteristike avtomatskih merilnih sistemov the mass concentration of nitrogen oxides- Performance characteristics of automated measuring systems 8. SIST EN 14792:2006 Emisije nepremičnih virov- Določanje masne NOx: (4-200/2000) ~1/1 plini koncentracijse dušikovih oksidov (NOx) - Referenčna metoda: kemiluminiscenca Stacionary source emissions - Determination of the mass concentration of nitrogen oxides - Reference method: chemiluminisscence 9. SIST ISO 7935:1996 Emisije nepremičnih virov- Ugotavljanje masne S02: (2-100/1 000) ~1/1 plini koncentracije žveplovega dioksida - Delovne karakteristike avtomatskih merilnih metod the mass concentration of su/fur dioxide - Performance characteristics of automated measuring methods 10. SIST EN 12619:2000 Emisije nepremičnih virov- Določevanje masne TOG: (0, 1-1/20) mg/m 0 plini koncentracije celotnega organskega ogljika pri gas es nizki koncentaciji odpadnih plinov- Kontinuirana metoda plamenske ionizacijske detekcije the mass concentration of total gaseous organic carbon at low concentrations in flue - Continuous flame ionization detector method 11. SIST EN 13526:2002 Emisije nepremičnih virov - Določevanje masne TOG: plini koncentracije celotnega organskega ogljika v (0,5-20/500)mg/m 3 odpadnih plinih pri uporabi topil - Kontinuirna metoda plamenske ionizacijske detekcije the mass concentration of total gaseous organic carbon in flue from so/vent using processes - Continuous flame ionisation detector method 12. DP02, 2009 Meritev koncentracije plinov- kontinuirno CH 4: (0,4-20/100) % plini interna metoda Measurement of gas concentrations - in-house method continuous (na osnovi SIST ISO 12039: Emisije nepremičnih virov - Določevanje ogljikovega monoksida, ogljikovega dioksida in kisika- Delovne karakteristike in kalibracija avtomatskih merilnih sistemov based on S/ST /SO 12039 carbon monoxide, carbon dioxide and oxygen - Performance characteristics and calibration of automated measuring systems) 0805-31 * Izdaja 5 Stran 4 od 7

Datum izdaje 1 lssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Replaces Annex dated 18. september 2012 Področja preskušanja glede na vrsto preskuša nja: fizikalno preskušanje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the tvpe of test item: environmnet and sam ples from the enironment (sources of emissions of substances) Št. preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Tltle of standard or non- and eventual relations to other standards or methods 13. DP06, 2009 Meritev perifernih parametrov T: (243-873) K plini interna metoda Measurement of peripheral parameters (-3o - 600) c in-house method p: (800-1200) hpa 14. SIST EN 14790:2005 Emisije nepremičn i h virov - Določevanje vodne vlaga: plini pare v odvodnikih (29-250) g/m 3 the water vapour in ducts 15. DP09, 2009 Določevanje prostorninskih deležev plinov v CH 4: (0,5-1 OO) % plini interna metoda deponijskem plinu in bioplinu C02: (0,5-1 OO) % in-house method Determination of vo/ume fractions of in 0 2: (1,O- 25) % landfi/1 gas and biogas (na osnovi SIST ISO 12039: Emisije nepremičnih virov - Določevanje ogljikovega monoksida, ogljikovega dioksida in kisika- Delovne karakteristike in kalibracija avtomatskih merilnih sistemov ln Environment agency: Performance Standards for Portable Systems for Emission Monitoring based on S/ST ISO 12039: carbon monoxide, carbon dioxide and oxygen - Performance characteristics and calibration of automated measuring systems and Environment agency: Performance Standards for Portable Systems for Emission Monitoring) H2S: (4-200) J.tlll H2: (20-1 000) ~dli 16. S IST EN 1911 :2011 Emisije neprem i čnih virov - Določevanje masne HCI: (0,2-100) mg/mo plini razen točk 6 in 8.2.3 koncentracije plinastih kloridov, izraženih kot except points 6 and 8.2.3 HCI- Standardna referenčna metoda; mass concentration of gaseous chlorides expressed as HCI- Standard reference method; 17. ISO 15713:2006 Stationary source emissions - Sampling and HF: (0,02-35) mg/mj plini razen točk 5.3, 5.4, 8 determination of gaseous fluoride conte nt; except points 5.3, 5.4, 8 18. VDI 3496, Blat! 1 (1982) Messen gasformiger Emissionen- Bestimmung NH3: plini razen točk 4.2, 5 der durch Absorption in Schwefelsaure (0,01-5000) mg/m 3 except points 4.2, 5 erfassbaren basischen Stickstoffverbindungen; 19. S IST EN 14791:2005 Emisije nepremičnih virov - Določevanje masne S02: (0,2-4400) mg/m" plini razen točk 5.5, 5.6, 8, 9, 10.2.3 koncentracije žveplovega dioksida - Referen č na H2S04: except points 5. 5, 5. 6, 8, 9, metoda; Stationary source emissions- (0,3-6800) mg/m 3 10.2.3 Determination of mass concentration of su/ph ur dioxide - Reference method; 0805-31 * Izdaja 5 Stran 5 od 7

Datum izdaje 1 lssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Replaces Annex dated 18. september 2012 - Področja preskušanja glede na vrsto preskušanja: fizikalno preskušanje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physica/ testing; sampling; chemistry Področja preskuša nja glede na vrsto preskušanca: okolj~ in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the tvpe of test item: environmnet and sam ples from the enironment (sources of emissions of substances) Št. preskusne metode in morebitne navezava na.druge standarde ali metode No. Reference to standard or non- Tftfe of standard or non- and eventual relations to other standards or metliods ' Uncertafnty of the result of 20. SIST EN 14385:2004 Emisije nepremičnih virov- Določevanje celotne kovine v 1Jg/m 0 : plini razen točk 5.1.3, 5.2.3, 5.2.9, emisije As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI in talij (TI) : 0,1-1000 5.2.10, 5.2.12, 5.2.13, 5.2.14, v arzen (As): 0,1-1000 8.7, 8.8, 9.2.2, kobalt (Co): 0,1-1000 except points 5.1.3, 5.2.3, 5.2.9, the total emission of the As, Cd, Cr, Co, Cu, Mn, krom (Cr): 0,1-1000 5.2.1 O, 5.2.12, 5.2.13, 5.2.14, Ni, Pb, Sb, TI and V baker (Cu): 0,1-2000 8.7, 8.8, 9.2.2, mangan (Mn): O, 1-1000 nikelj (Ni): 0,1-1000 svinec (Pb): 0,1-1000 antimon (Sb): 0,1-2000 vanadij (V): 0,1-1000 selen (Se): 0,1-1000 kositer (Sn): O, 1-1000 cink (Zn): 0,2-10000 21. SIST EN 13649:2002 Emisije nepremičnih virov- Določevanje masne plini razen točk 4.3, 4.4, 4.5, 5.2, 5.3, koncentracije posameznih organskih spojin - 7 Metoda z aktivnim ogljem in desorpcije s except points 4.3, 4.3, 4.5, 5.2, topi lom; 5.3, 7 the mass concentration of individual gaseous organic compounds - Activated carbon and solvent desorption method 22. VDI 3862, Blati 2 (2000) Messen gasfl:irmiger Emissionen - Messen alifatski in aromatski plini razen točk 5.2, 6 aliphatischer und aromatischer Aldehyde und aldehidi in ketoni: except points 5.2, 6 Ketone nach dem DNPH-Verfahren - formaldehid: Gaswaschflaschen-Methode; (2-1 OO) mg/m 3 Gaseous emission measurement - Measurement of aliphatic and aromatic aldeydes and ke tone s by DNPH method - lmpinger method 0805-31 * Izdaja 5 Stran 6 od 7

LP-0? 6 Datum izdaje llssued on 29. oktober 2012 Zamenjuje izdajo z dne 1 Replaces Annex da ted 18. september 2012 Tabela 2 1 Table 2 Mesto izvajanja: v laboratoriju in na terenu 1 Site: in the laboratory and fieldwork Področja preskušanja glede na vrsto preskušanja: fizikalno preskuša nje; vzorčenje 1 Testing fields with reference to the type of test: physical testing; sampling Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the type of test item: environment and sam IJ/es from the environment (sources of emissions of substances) št. preskusne metode in morebitne navezava na druge standarde ali metode No. Reference to standard or non- Tltle of. standard or non- and eventual relations to other standards or methods 23. SIST EN 13284-1:2002 Emisije nepremičnih virov- Določevanje (0, 1-1000) mg/m, plini majhnih masnih koncentracij prahu- 1. del: ga se s Ročna gravimetrijska metoda; in! and low range mass concentration of dust- Part 1: Manual gravimetric method SIST ISO 9096:2003 Emisije nepremičnih virov- Ročno določanje masne koncentracije trdnih delcev; Stationary source emissions - Manual determination of mass concentration of particulate matter 24. VOl 2066, Blat! 10 (2004) Messung der Emissionen von PM1o und PM2.s PM1o: (1-20) mg/m~ plini an GefUhrten Quellen nach dem PM2.s: (1-20) mg/m 3 lmpaktionsverfahren 25. DP10, 2009 izračun masnih pretokov in emitiranih količin plini interna metoda snovi, izmerjenih z metodami pod točkami 2-12, in-house method 14-23 Opombe 1 Notes: V vseh točkah podrobnega obsega akreditacije, pri katerih v rubriki "Območje preskuša nja; preskušanja" ni navedenih podatkov, veljajo določila posameznih standardov oziroma nestandardnih preskusnih metod, ki se na to nanašajo. ln all columns of the scope of accreditation where the cel/s under "Range of measurement, testing; Uncertainty of the result of testing" are empty, the provisions of the re/evant standards or non-s should apply. V točkah podrobnega obsega akreditacije, pri katerih v rubriki "Oznaka standarda" ni navedena letnica izdaje standarda, se sklic nanaša na zadnjo (veljavno) izdajo standarda, kar jamči interni sistem sledenja in prilagajanja laboratorija spremembam. ln those columns of the scope of accreditation where the cel/s under "Reference" do not specify the year of issue of the standard, the /atest (va/id) standard should apply. This is assured by interna/laboratory system of follow~up and adaptation to changes. V točkah podrobnega obsega akreditacije, pri katerih sta v rubriki "Oznaka standarda" navedeni dve ali več oznak standardov, se sklic v celoti nanaša na identične standarde. ln those columns of the scope of accreditation where the cel/s under "Reference" specify two or more codes of standards, the complete citation to identical standards should apply. 0805-3 1 * Izdaja 5 Stran 7 od 7