Fire Impacts in Metro Railway Tunnel: A Mathematical Approach

Similar documents
How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

EVACUATION MODELLING IN ROAD TUNNEL FIRES

How design fires can be used in fire hazard analysis

CFD Analysis of Fire Characteristics on Subway Junction Station

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

Simulation study of evacuation in high-rise buildings

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

THE COMPARISON OF THE RESULTS OF A FULL SCALE EVACUATION TEST TO THE CALCULATION METHOD OF HUNGARIAN REGULATIONS AND TO THE PATHFINDER SOFTWARE

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Hot Issues in Fire Engineering July 2014

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

Fire evacuation drill

Evacuation Hazards in Crowded Subway Stations

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

The Study of Evacuation Times from the Multiplex Theatres

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

Road tunnel safety rules in Italy: the tunnel country

Simulation of Full-scale Smoke Control in Atrium

A Study on the People Evacuation Safety for the. Underground MRT Station

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

4.13 Security and System Safety

Sprinklers Modeling for Tunnel Road Fire Fighting

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Tunnel Fire Dynamics and Evacuation Simulations

Underground fires in metro systems failures, accidents and terrorism

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

Statue of Liberty: A Risk Analysis

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Hot Issues in Fire Engineering 12 March 2013

EVACUATION MODELING DEPENDENCE ON INPUT PARAMETERS

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

Fire Risk Assessment and Computer Simulation of Fire Scenario in Underground Mines

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX. on the European Rail Traffic Management System European deployment plan

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Considerations in the Design of Smoke Management Systems for Atriums

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Upward Evacuation Experiment for Estimating Evacuation Speed in Water Disaster

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

Fire Hazard Analysis of Technical Area 53 Building 1

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

FORMULATION OF FIRE SAFETY REQUIREMENTS FOR NEW RAILWAY INFRASTRUCTURES

Effects of Smoke on Evacuation Martin Lopušniak 1, a

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

Case Study 1 Underground Car Park

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

Directional Sounders Isaac Papier VP Industry Relations Honeywell Life Safety

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Fire and Smoke Management in a Uni-Directional Road Tunnel for a Congested Traffic Condition

Case Study of Underground Car Park. Team Japan

Emergency Evacuation Plan South Patterson Building (SPB)

Construction Innovation Center Building 186

EMERGENCY EVACUATION How prepared are you?

DUNCAN STUDENT CENTER. Emergency Action Plan

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

A case study for integrated modelling of personnel evacuation with pool fire simulation to increase safety in design for offshore oil and gas projects

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

Fire Scenario Influence of Material of Boundary Condition on Results

Tunnelling and Underground Space Technology

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

INVESTIGATING BENEFITS EVACUATION AND EMERGENCY LIGHTING SYSTEMS IN TUNNELS BY USING INTELLIGENT. David Zamora, MariMils, Finland VP Marketing & Sales

The Singapore Fire safety Engineering Guidelines (SFEG)

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

12F052 ADVANCED FLORIDA (MULTIPLE OCCUPANCY BUILDINGS)

This document is a preview generated by EVS

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

EMERGENCY EVACUATION Can your staff evacuate your occupants safely?

Case Study 2 Production and Storage. SFPE Polish Chapter Wojciech Węgrzyński, Grzegorz Krajewski Building Research Institute (ITB)

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Impact of quick incident detection on safety in terms of ventilation response

Emergency Action Plan Leading the Fight

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

A DESCRIPTION OF THE PROBABILISTIC AND DETERMINISTIC MODELLING USED IN FIRECAM

Culminating Project. Fire Protection and Life Safety Engineering Analysis. Cal Poly. Center for Science and Mathematics. Fire Protection Engineering

Compression of Fins pipe and simple Heat pipe Using CFD

Evaluation of a Support System for Large Area Tourist Evacuation Guidance: Kyoto Simulation Results

Dynamic Evacuation Guidance Considering Occupant Distribution

Recent BRANZFIRE enhancements and validation

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

Transcription:

The International Journal of Engineering and Science (IJES) Volume 6 Issue 8 Pages PP 39-51 2017 ISSN (e): 2319 1813 ISSN (p): 2319 1805 Fire Impacts in Metro Railway Tunnel: A Mathematical Approach Anastasios Kallianiotis 1 *, Konstantinos Sakkas 2, Dimitrios Kaliampakos 3 1 Mining Engineer, Ph.D., School of Mining & Metallurgical Engineering, National Technical University of Athens, Greece, kallianiotis@metal.ntua.gr 2 Mining Engineer, Ph.D., School of Mining & Metallurgical Engineering, National Technical University of Athens, Greece, sakkas@metal.ntua.gr 3 Professor, School of Mining & Metallurgical Engineering, NTUA, Iroon Polytechniou 9 Zografou 15780 Athens, Greece, E-mail: dkal@central.ntua.gr --------------------------------------------------------ABSTRACT----------------------------------------------------------- The growing need for more complicated underground urban systems has resulted to the development of evacuation procedures improvement. In addition, beside the fact that structures with massive public traffic such as mall or metro systems, have improved safety systems and plans, emergencies still occurs. The special and alternative circumstances and conditions, which characterize the underground spaces in contrast to surface constructions, as well as the severity of the consequences if an accident occurs, stimulated the research for prevention and forecast of the consequences.one major event that may affect human health and structure stability is fire. Byproducts of fire influence the evacuation by affecting vital occupants points such as visibility and physical strain. The total time from fire ignition to the time that an area reach untenable conditions, in which people become unable to recue themselves, is crucial in order to evaluate structure safety or re-plan the evacuation routes and safety degree. The paper analysesthe effect of a fire in a typical railway Metro tunnel by using Fire Dynamic Simulation (FDS) and computer evacuation models. This is achieved by using pre-defined fire scenarios and measure three important parameters that affect evacuation occupants: CO density, Temperature and Visibility. Keywords: railway evacuation, metrotunnel evacuation, tunnel fire simulation, exit routes, evacuation simulation ------------------------------------------------------------------------------------------------------------------------------------- Date of Submission: 25-07-2017 Date of Publication: 10-08-2017 ---------------------------------------------------------------------------------------------------------------------------- --------- I. INTRODUCTION Over the last decade, tunnel construction activities (road and railway) in Europe were accelerated, as a general need to facilitate the transportation of people and goods between large areas of the continental Europe and preserve the quality of the environment - inside and outside the cities. Although accident rates in road and rail tunnels are low and fires are not especially common in tunnels, the consequences in a tunnel can be far more severe than similar fires in conventional structures. Large tunnel fires have shown the devastating effects of smoke and heat on people escaping from tunnels. Additionally, the fires caused severe damage to the tunnel structure and financial losses due to interrupted operation. As a consequence, the required fire safety measures for tunnel infrastructures have become more stringent in recent years(ita COSUF, 2014). Even though the construction works are evolving, it is only in the recent years that fire safety of such infrastructure has gained attention. Therefore, and owing to the recent fire incidents, safety guidelines for road tunnels have reached high level of detail and exhibit substantial degree of international harmonization, which led to the EC directive 54/2004 which seeks to ensure that all tunnels longer than 500 meters, whether in operation, under construction or at the design stage and forming part of the trans-european road network, comply with the new harmonized safety requirements. In contrast, safety requirements for rail tunnels and underground systems are limited to more basic and less uniform requirements. The standards for smoke control in metro systems, for example, might vary even within a country from project to project. * Corresponding author (e-mail: kallianiotis@metal.ntua.gr) DOI: 10.9790/1813-0608015263 www.theijes.com Page 52

National regulations (e.g. NFPA130 from USA or SIA 197/1 according to German standards) provide at times quite specific minimum requirements, e.g. with respect to the maximum allowable distance between emergency exits and to the minimum width of escape paths while the EU regulation 1303/2014 lacks of guidelines for the implementation. Therefore, a successful evacuation process is critical to reach this objective. Currently, evacuation calculations are becoming a part of fire safety science performed either by hand calculations or by modeling and simulation (Kuligowski, Peacock, & Hoskins, A Review of Building Evacuation Models, 2nd edition, 2010). As more and more people are affected by the impact of emergencies and disasters across the globe, it is imperative that response and recovery agencies, organizations and individuals focus on preparedness for a wide range of situations (Australia Emergency Management, 2005). Although a safety plan incorporates actions focusing on prevention, the establishment of procedures to govern and coordinate the available measures for the safe exit of the users in the case of an emergency is also a key element of the process. Thus, a reliable plan for the escape and evacuation of the users should be available and tested in order to identify problems and optimize the whole process. Orderly and complete evacuation of all occupants and visitors requires the careful provision for exit routes and accounting for all individuals after the evacuation (Gustin, 2007). Figure 1. Railway risk scenarios (EU Commision, 2007) Evacuation calculations have become a part of performance-based analyses to assess the level of life safety provided in buildings (Nelson H. E., 2003), by also taking into account the Required Safe Egress Time/Available Safe Egress Time (RSET/ASET) concepts. In some cases, engineers are using backof-theenvelope (hand) calculations thatusually follow the instructions and assumptions given by the codes to calculate mass flow evacuation.to achieve a more realistic evacuation calculation, and save time, engineers have been looking to computer models to assess a building s life safety (Kuligowski & Peacock, 2005).Evacuation modelling is a virtual representation of reality that relies on the theory and the data collected. This technique is used to simulate the course of the events that may occur during emergency scenarios (Ronchi, 2012). This paper presents the impact of 4 fire scenarios in a typical railway tunnel evacuation passengers, regarding three parameters in major consideration: CO density, Temperature and Visibility. II. TUNNEL EVACUATION A disorganized evacuation can result in confusion, injury, and property damage. Therefore, when developing an emergency action plan it is important to determine the following(occupational Safety and Health Administration, How to Plan for Workplace Emergencies and Evacuations, 2001): Conditions under which an evacuation would be necessary. A clear chain of command to control the evacuation process and designation of evacuation wardens to assist the evacuation and to account for personnel. Designation of what, if any, employees will continue or shut down critical operations during an evacuation DOI: 10.9790/1813-0608015263 www.theijes.com Page 53

Specific evacuation procedures, including routes and exits, posted and easily accessible to all employees, as well procedures to assist the evacuation for people with disabilities A system for accounting for personnel following the evacuation. One major issue that should be designed and maintained appropriately, is the exit routes (Figure2). An exit route is a continuous and unobstructed way of exit travel from any point in a building or structure to a public way and consists of three separate and distinct parts: the way of exit access (portion of an exit route that leads to an exit), the exit (portion of an exit route that is generally separated from other areas to provide a protected way of travel to the exit discharge), and the way of exit discharge (part of the exit route that leads directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside.). Figure2. Exit route paths drawn on a floor plan (Occupational Safety and Health Administration, Fact Sheet- Emergency Exti Routes, 2003) To ensure the compliance with above requirements, organizations such as the National Fire Protection Association NFPA(National Fire Protection Association, Life Safety Code - NFPA 101, 2015), the European Guidelines CFPA(Confederation of Fire Protection Association Europe, 2009), the Building Code of Australia BCA(Australian Building Codes, 2004), have defined some minimum requirements and standards that concern the limitation of certain parameters, as the following: exit route (path) width travel distance exit route capacity exits' door relative location occupants load evacuation time The above parameters' limitations aim to achieve the best conditions during evacuation procedure and to minimize damage (human and property) as well. Of course some adjustments are to be made with respect to the type of the facility and the number/type of the occupants in it. In order to calculate evacuation time, both evacuation models and hand calculations, consider human speed. There have been observations and experiments (Nelson & Mowrer, 2002) in order to create an equation to calculate human speed. From these observations, it is derived that human evacuation speed is always related to population density. There are some main characteristics in underground spaces (as well as subway rails) that make the evacuation procedure more complex and dangerous for passengers. DOI: 10.9790/1813-0608015263 www.theijes.com Page 54

Table 1 Characteristics of underground spaces in contrast to surface buildings Underground spaces Upward travelling in stairwells Smoke moves to escape routes Faster temperature increase for the same fuel Passengers have little sense of orientation Passengers tend to leave the entrance - exit they entered Slower evacuation start Passengers fatigue due to upward movement on ramps and stairs Surface buildings Downward travelling in stairwells Smoke moves to the closest opening: window, etc. Slower temperature increase Easier orientation and (possibly) natural lighting Occupants tend to follow signs and markings Lesser evacuation delay Lesser occupants fatigue III. EVACUATION TIME 1.1 Required and available safe egress time In general, life safety from emergency is achieved if the required safe egress time (RSET) is shorter than the available safe egress time (ASET), where the ASET is defined as the time when fire-induced conditions within an occupied space or building become untenable (Nelson & Mowrer, 2002). Untenable conditions when an occupant inside or entering an enclosure is expected to be unable to save themselves (is effectively incapacitated) due to the effects of smoke, heat or toxic gases (Confederation of Fire Protection Association Europe, 2009). The Required safe egress time (RSET) can be subdivided into a number of discrete time intervals, the sum of which constitute the total RSET: RSET = t d + t a + t o + t i + t e Equation 1 where, t d is the time from fire ignition to detection, t a the time from detection to notification of occupants of an emergency, t o the time from notification until occupants decide to take action, t i the time from decision to take action until evacuation commences and t e the time from the start of evacuation until it is completed. NFPA 130 adopts a restriction that sets as sufficient egress capacity for the platform occupant load to evacuate the station platform in 4 minutes or less (NFPA 130, 2014). In addition, the station shall be designed to permit evacuation from the most remote point on the platform to a point of safety in 6 minutes or less (NFPA 130, 2014). Moreover, the worst-case scenario and the considerations of evacuation of Taipei MRT system, require that the occupants on the platform have to evacuate the place within 6 minutes. If the station is a multi-floor construction, in 6 minutes egress time, should be added 2 minutes per added floor (Chien et al., 2004). These time criteria are known as the ASET which means the time available for the occupants to leave platform and station before they become overwhelmed by the effects of the fire and smoke. In this code there is no reference about the railway tunnel evacuation time. The determination of ASET is a complex procedure that need to take account many parameters. IV. RAILWAY TUNNEL FIRE SIMULATION One of the most severe emergency situations that can be materialized in an underground environment is a fire event. This can impose serious heat loads, but more importantly it can generate smoke quantities which can impede the users ability to self-rescue or threaten their lives(salmensaari, 2010).During the past years underground metro has experienced some severe threats as the one in Brussels or St. Petersburg. Unfortunately, the death toll was heavy but hopefully, the smoke volume was minimal which allowed for the passengers to reach for the nearest exit, as the train stopped inside the tunnel. This paper represents the effects of a fire in a railway tunnel as regard 3 parameters: Temperature, CO density and Smoke visibility. The simulations take place in a typical Metro tunnel and the fire assumed to start close to station. More specified, the following assumptions have been taken into account: Distance between exits are 250m One exit is the entrance to the station and the other an ascending staircase Fire take place in the middle point of the exits DOI: 10.9790/1813-0608015263 www.theijes.com Page 55

Fire scenarios are based on Guide to Road Tunnel Safety Documentation, Booklet 4 of Centre d Etudes des Tunnels. The simulated fires Heat Release Rate are 5, 10, 20, and 50MW There is no ventilation in the tunnel (pressure difference from exits openings - are zero) The simulations achieved by using FDS and Pyrosim software packages Simulations run for 600 seconds (10 minutes) All four fire scenarios, assumed to ignite 1m 2 fuel area and reach the highest heat release rate (HRR) in 180sec and keep it for at least 1000sec. Figure 3 show the fire spread regarding to time for a 5MW fire in a railway tunnel as shown in smoke view, a support results visualization of FDS software. Figure 3 Smoke spread visualization regarding time (A-20, B-100, C-200, D-300 ) for 5MW fire In order to account the temperature, CO density and visibility around the fire, plenty of device sensors are placed all over the space to measure the corresponding parameter.figure 4 and Figure 5 shows in graph mode, the temperature increment regarding to time for different distance from fire origin. In these figures, are presented the lowest (5MW) and the highest (50MW) fire intensity respectively. In addition, in these graphs the high changes of temperature in very short time are derived from fire flashovers and computational error, so in short distance line of fire origin (5m) are removed from axes. DOI: 10.9790/1813-0608015263 www.theijes.com Page 56

0.0 13.3 26.5 39.7 52.9 66.1 79.3 92.4 105.7 118.9 132.0 145.2 158.5 171.6 184.8 198.0 211.2 224.4 237.6 250.8 264.1 277.2 290.4 303.6 316.8 330.0 343.2 356.4 369.6 382.8 396.0 409.2 422.4 435.6 448.8 462.0 475.2 488.4 501.6 Temperature (C) 1 27 53 79 105 131 157 183 209 235 261 287 313 339 365 391 417 443 469 495 521 547 573 599 625 651 677 703 729 755 781 807 833 859 885 911 937 963 989 Temperature (C) Fire Impacts in Metro Railway Tunnel: A Mathematical Approach Temperature spread of 5MW fire with regard to time - per distance 60 55 50 45 40 35 30 25 20 Time (sec) 400 350 300 250 200 150 100 50 0 Temp +05 Temp +10 Temp +20 Temp +30 Temp +40 Temp +50 Temp +60 Temp +70 Temp +80 Temp +90 Temp +100 Temp +110 Temp +120 Figure 4 Temperature spread for 5MW fire Temperature spread of 50MW fire with regard to time - per distance Time (sec) Temp +05 Temp +10 Temp +20 Temp +30 Temp +40 Temp +50 Temp +60 Temp +70 Temp +80 Temp +90 Temp +100 Temp +110 Temp +120 Figure 5 Temperature spread for 50MW fire Therefore, by using excel trendline option, an optimal function for these graphs is: f(t) = aln(t) + b Equation 2 DOI: 10.9790/1813-0608015263 www.theijes.com Page 57

Values Fire Impacts in Metro Railway Tunnel: A Mathematical Approach Where t is the time in seconds and a, b constant numbers that depend on fire intensity and distance. In Figure 6 and Table 2 the values of a and b constant numbers in reference to distance for 5MW fire are presented. The r- square number is a measure of the goodness of fit of the trendline to the data (a value of 1 is a perfect fit). InFigure 6a and b curves and trendlines for 5MW fire are presented the trendlines for a and b constant number with regard to distance for 5MW fire. Therefore, a function with two variables that gives the temperature for given time and distance is the follow (5MW fire): 5MW fire, Temperature: f(t, d) = (0.04 d + 8.34) ln(t) (0.33 d + 5.62) Equation 3 Changes of constant numbers with regard to distance 20.00 10.00 y = 0.036x + 8.3378 0.00 0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0-10.00-20.00-30.00-40.00 y = -0.3326x - 5.6165-50.00 Distance (m) a - constant b - constant Linear (a - constant) Linear (b - constant) Figure 6a and b curves and trendlines for 5MW fire (temperature function) Table 2 Constant values for different isocurves of distance for 5MW fire Distance a b r - square 5,0 9,55-14,89 0,72 10,0 7,72-4,62 0,82 20,0 6,95 1,02 0,60 30,0 8,71-10,53 0,68 40,0 9,79-19,01 0,81 50,0 10,17-22,26 0,84 60,0 11,10-28,54 0,86 70,0 12,27-36,23 0,90 80,0 13,33-43,67 0,94 90,0 13,50-46,19 0,95 100,0 12,57-42,45 0,95 110,0 12,02-40,55 0,89 120,0 8,95-26,19 0,82 Using the same methodology follows the below functions of each fire intensity: 10MW fire, Temperature: f(t, d) = (0.06 d + 17.25) ln(t) (0.59 d + 31.87) Equation 4 20MW fire, Temperature: f(t, d) = (0.02 d + 35.16) ln(t) (0.56 d + 92.08) Equation 5 50MW fire, Temperature: f(t, d) = (0.06 d + 64.68) ln(t) (0.98 d + 212.58) Equation 6 Similarly, are defined the mathematical functions that connects distance and time to CO density (counted in ppm). Figure 7 shows the changes to CO density (in ppm) with regard to time, for different distances from fire origin (are presented only 4 distance curves to avoid graph confusion). As well as temperature case, the relation of CO density and time may mathematically appear as f(t) = aln t+b Equation 2. In addition, Figure 8 DOI: 10.9790/1813-0608015263 www.theijes.com Page 58

Values CO ppm Fire Impacts in Metro Railway Tunnel: A Mathematical Approach presents the a and b constant number changes (and their trendlines) with regard to distance for 20MW fire. Finally, Figure 9visualizes the spread of CO density for 50, 150, 300 and 500 sec after 50MW fire ignition. 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 CO density spread of 20MW fire with regard to time - per distance Time (sec) Temp +05 Temp +10 Temp +50 Temp +120 Figure 7 CO density spread for 20MW fire Changes of constant numbers with regard to distance 1000.00 500.00 0.00-500.00-1000.00-1500.00-2000.00-2500.00 Figure 8 a and b curves and trendlines for 20MW fire (CO density function) y = 2.1046x + 189.24 R² = 0.9022 0 20 40 60 80 100 120 Distance (m) a b Linear (a) Linear (b) y = -12.759x - 662.3 R² = 0.9352 DOI: 10.9790/1813-0608015263 www.theijes.com Page 59

Figure 9 CO spread visualization regarding time (A-50, B-150, C-300, D-500 ) for 20MW fire Therefore, the approximate functions for CO density spread are the follows: 5MW fire, CO density: g(t, d) = (0.61 d + 43) ln(t) (3.83 d + 147) Equation 7 10MW fire, CO density: g(t, d) = (1.27 d + 91) ln(t) (7.48 d + 307) Equation 8 20MW fire, CO density: g(t, d) = (2.10 d + 189) ln(t) (12.76 d + 662) Equation 9 50MW fire, CO density: g(t, d) = (3.7 d + 517) ln(t) (23.95 d + 1989) Equation 10 Regarding the smoke visibility spread, the facts are quite different since when the smoke reach an area, the visibility drops to 0.5m rapidly (Figure 10).Table 3presents in one hand the moment that smoke reaches the point of interest and on the other hand the moment when visibility drops below 1m. This rapidly drop occurs in average of 110 for 10 MW, 80 for 20MW, 60 for 50MW and 200 for 5MW fires. Obviously, an optimal function for these graphs is: h(t) = a Equation 11 Where t is the time in seconds and a, b constant numbers that depend on fire intensity and distance. More specifically, b represents the time in which the smoke reaches the area of interest. Therefore, by making the graph relation between b and distance an approximate trendline is determined (Figure 11). (t b) DOI: 10.9790/1813-0608015263 www.theijes.com Page 60

Time (sec) Visibility (m) Fire Impacts in Metro Railway Tunnel: A Mathematical Approach Visibility with regard to time for 10MW fire - per distance 30 25 20 15 10 5 0 0.00 100.00 200.00 300.00 400.00 500.00 600.00 Time (sec) Vis +05 Vis +10 Vis +30 Vis+50 Vis +80 Vis +110 Vis +120 Figure 10Visibility with regard to time for 10MW fire Table 3 Smoke affect timings for 10MW fire Distance Time smoke reach point of Time visibility drops below interest (sec) 1m (sec) 5 34 150 10 32 160 30 54 170 50 81 185 80 121 210 110 164 255 120 180 305 Smoke affect timings with regard to distance 350 300 250 200 150 100 50 0 y = 1.1641x + 137.65 R² = 0.917 y = 1.3043x + 19.677 R² = 0.9944 0 20 40 60 80 100 120 Distance (m) Time smoke reach point of interest (sec) Linear (Time smoke reach point of interest (sec)) Time visibility drops below 1m (sec) Linear (Time visibility drops below 1m (sec)) Figure 11 Smoke affect timings with regard to time for 10MW fire DOI: 10.9790/1813-0608015263 www.theijes.com Page 61

Therefore, the approximate functions for visibility are: 5MW fire, CO density: h(t, d) = 10MW fire, CO density: h(t, d) = 20MW fire, CO density: h(t, d) = 50MW fire, CO density: h(t, d) = 30 (t (1.62d+26)) 30 (t (1.30d+20)) 30 (t (1.08d+17)) 30 (t (0.98d+13)) Equation 12 Equation 13 Equation 14 Equation 15 V. CONCLUSIONS The main conclusion from this study is that the fire impacts can be mathematically predicted and determined by making a deterministic analysis in Fire Dynamic Simulation (FDS) software. Since a fire is a rapidly developing chemical procedure, the area close to it may give unpredictable results and obviously may harm instantaneous the occupants that waits or pass through that area. This effect becomes more intensive as the fire HRR increasing. The most rapidly impact spread is the smoke density that affects visibility. Smoke high density (visibility<1m) gives 40 to 70 (depends on fire HRR) to passenger to start moving without being affected and spreads with a speed of 1 to 1.3 m/s. Considering that occupant speed in low crowded area assumed to be 1.2m/s, the need of initiateevacuation is major. Trapped in an over smoked area may drive to disorientation and high evacuation time in an area that heat and toxic gas continue to affect the body. The results of mathematical approach may be used in area like tunnels that consist of a long unobstructed corridor. More geometrically complex structures may affect the spread of fire (and its byproducts) with impact (positive or negative) to human and structure, as well as the existence of ventilation may improve or aggravate the fire affects. Finally, combining the mathematical functions that arises from this paper and human toxic limitation, is a promising methodology to calculate the fractional effective dose on passengers and determine the available safe egress time (ASET). ACKNOWLEDGMENTS The authors would like to thank IKY FELLOWSHIPS OF EXCELLENCE FOR POSTGRADUATE STUDIES IN GREECE SIEMENS PROGRAM for providing scholarship to complete the current research. They would also like to extend a special note of appreciation to Thunderhead Engineering group, for providing educational license to use and work on Pyrosim and Pathfinder platforms and for the excellent and direct cooperation of its members. REFERENCES [1]. Adjiski, V., Mirakovski, D., Despodov, Z., & Mijalkovski, S. (Volume 14, Issue 3). Simulation and optimization of evacuation routes in case of fire in underground mines. Journal of Sustainable Mining, 133-143. [2]. Association, N. F. (2000). NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems. Quincy, Massachusetts: National Fire Protection Association. [3]. Australia Emergency Management. (2005). Australian Emergency Manual Series - Evacuation planning_manual Number 11. Dickson: Commonwealth of Australia. [4]. Australian Building Codes. (2004). Building Code of Australia (Volume one ed.). Canberra: CanPrint Communications Pty Ltd. [5]. Capote, J. A., Alvear, D., Abreu, O., Cuesta, A., & Alonso, V. (2013). A real-time stochastic evacuation model for road tunnels. Safety Science, 52, 73-80. [6]. Casavant, D. A. (2007). Emergency Preparedness for Facilities: A Guide to Safety Planning and Business Continuity. Plymouth: Government Institutes. [7]. Centre d'etudes des Tunnels. (2003, September). Guide to Road Tunnel - Safety Documentation_Booklet 4, Specifi Hazard Investigations. France: Actaes Editions. [8]. CFPA. (2009). Fire safety engineering concerning evacuation from buildings, CFPA -E No 19:2009. Zurich: CFPA-E Guidlines. [9]. Chien et al., S.-W. (2004). A Study on the People Evacuation Safety for the Underground MRT Station. 6th Asia-Oceania Symposium on Fire Science and Technology (pp. 292-304). Daegu, Korea: International Association for Fire Safety Science. [10]. Confederation of Fire Protection Association Europe. (2009). European Guidlines, Fire Safety Engineering concerning Evacuation from Buildings. Zurich, Stockholm: CFPA. [11]. Erkan, İ., & Hastemoglu, H. (2015). Building Evacuate Module for Urban Underground Passages: Subway Station in Turkey. Journal of Transportation Technologies, 1. [12]. EU Commision. (2007, December 20). Concerning the technical specification of interoperability relating to safety in railway tunnels in the trans-european conventional and high-speed rail system. Official Journal of the European Union. [13]. Greek Fire Brigade Headquarters, D. o. (1999). Building Fire Safety Regulations (Decree 71/88), (In Greek). Athens: Fire Brigade Headquarters. [14]. Gustin, J. F. (2007). Disaster & Recovery Planning: A Guide fro Facility Managers, Fourth edition. Lilburn, Georgia: The Fairmont Press, Inc. [15]. ITA COSUF,. (2014). An Engineering Methodology for Performance-Based Fire Safety Design of Underground Rail Systems. [16]. Jong-Hoon Kim, Woon-Hyung Kim, Sam-Kew Roh, Duck-Hee Lee, & Woo-Sung Jung. (2009). Experiments of the subway car egress. DOI: 10.9790/1813-0608015263 www.theijes.com Page 62

[17]. Kallianiotis, A. (2015). Optimization Of Underground Spaces Evacuation Procedures: Evaluation and Optimization Of Exits Position, Ph.D. Thesis. Athens. [18]. Kallianiotis, A., & Kaliampakos, D. (2012). Improving Evacuation Plans in Underground Spaces: The Role of Emergency Exits Location. 13th World Conference of ACUUS: Advances in Underground Space Development (pp. 100-102). Singapore: Research Publishing. [19]. Kallianiotis, A., & Kaliampakos, D. (2014). A Study on Undergound Evacuation Plan Parameters. Seoul. [20]. Kallianiotis, A., & Kaliampakos, D. (2016). Evaluation of Underground Spaces Evacuation Effectiveness. Procedia Engineering, Volume 165, 2016, Pages 564-574. [21]. Kallianiotis, A., & Kaliampakos, D. (n.d.). Optimization of exit location in underground spaces. [22]. Kuligowski, E. D., & Peacock, R. D. (2010). A Review of Building Evacuation Models, 2nd Edition. Washington: National Institute of Standards and Technology Technical Note 1680. [23]. Kuligowski, E. D., Peacock, R. D., & Hoskins, B. L. (2010). A Review of Building Evacuation Models, 2nd edition. National Institute of Standards and Technology, Technical Note 1680. [24]. National Fire Protection Association. (1999). NFPA 520 Standard on Subterranean Spaces. Quincy, Massachusetts: National Fire Protection Association. [25]. National Fire Protection Association. (2013). NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (2014 Edition ed.). Quincy, Massachusetts: National Fire Protection Association. [26]. National Fire Protection Association. (2015). Life Safety Code - NFPA 101. Quincy, Massachusetts: National Fire Protection Association. [27]. Nelson, H. E. (2003). Personal Communication. [28]. Nelson, H. E., & Mowrer, F. W. (2002). Emergency Movement. In Philip J. DiNenno et.al., SFPE Handbook of Fire Protection Engineering (pp. 367-380). Quincy, Massachusetts: National Fire Protection Association. [29]. Occupational Safety and Health Administration. (2001). How to Plan for Workplace Emergencies and Evacuations. OSHA. [30]. Occupational Safety and Health Administration. (2003). Fact Sheet- Emergency Exti Routes. OSHA. [31]. Occupational Safety and Health Administration. (2003). Fact Sheet: Emergency Exti Routes. OSHA. [32]. Occupational Safety and Health Administration. (2011, June 8). Regulations (Standards - 29 CFR). Retrieved January 16, 2013, from Occupational Safety & Health Administration - OSHA: www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=12886 [33]. Papakonstantinou, D., Benardos, A., Kallianiotis, A., & Menegaki, M. (2016). Analysis of the Crowd Evacuation Modeling Approaches for the Case of Urban Underground Spaces. Procedia Engineering, Volume 165, Pages 602-609. [34]. Prawdzik, E., Clifford, P., & Nightingale, S. (2013). Evacuation Assessment In Transport Planning Models. AET 2013. [35]. Proulx, G. (2002). Movement of People: The Evacuation Timing. In P. J. et.al., SFPE Handbook of Fire Protection Engineering (pp. Section 3, 342-366). Quincy, Massachusetts: National Fire Protection Association. [36]. Ronchi, E. (2012). Evacuation Modeling in road Tunnel Fires (Ph.D. thesis). Lund. [37]. Ronchi, E., Colonna, P., Capote, J., Alvear, D., Berloco, N., & Cuesta, A. (2012). The evaluation of different evacuation models for assessing road tunnel safety analysis. Tunnelling and Underground Space Technology, 30, 74-84. [38]. Salmensaari, T. (2010). Safety in Long Subsea Rail Tunnels. Helsinki: Aalto University. [39]. Schachenmayr, M. P. (1998). Application Guidelines for the Egress Element of the Fire Protection Standard for Fixed Guideway Transit Systems - For Use with NFPA 130. New York City: Parsons Brinckerhoff Quade & Douglas, Inc. [40]. Thematic Network FIT,. i. (2006). Fire in Tunnels_General Report. Brussels. [41]. Vigne, G., Herrera, F., Jönsson, J., & O Donnell, D. (2011). The use of advanced evacuation modelling for building design. [42]. W.L.Wang, & JacquelineLo, T. (Volume 71, 2014). A Simulation Study on Passenger Escape in Rail Tunnels. Procedia Engineering, 552-557. [43]. Wang, W., & Lo, T. J. (2014). A Simulation Study on Passenger Escape in Rail Tunnels. Procedia Engineering, 71, 552-557. [44]. Wang, Z., Chen, F., & Li, X. (2012). Comparative Analysis and Pedestrian Simulation Evaluation on Emergency Evacuation Test Methods for Urban Rail Transit Stations. Scientific Journal on Traffic and Transportation Research, 6, 535-542. Anastasios Kallianiotis " Fire Impacts in Metro Railway Tunnel: A Mathematical Approach " The International Journal of Engineering and Science (IJES) 6.8 (2017): 52-63. DOI: 10.9790/1813-0608015263 www.theijes.com Page 63