PROMATIC WDC Heating controllers Energy under control

Similar documents
Solar controllers Energy under control

Trade Product List 2013 BIOMASS ACCESSORIES

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

TR 0603mc U Solar Controller

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

ECL Comfort V a.c. and 24 V a.c.

RVL481. Heating Controller. including d.h.w. heating

RVP310. Heating Controller. Building Technologies HVAC Products

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

RVL470. Heating Controller. Use. Functions. Series B

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort 110, application 130

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Weather compensated flow temperature control of heating and boiler systems

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

G a

RVL480. Heating Controller

Overview - Danfoss Link and living software versions

INSTRUCTION FOR THE USER THC V E OIL BLU

Corrigo E. Second generation which contains all applications and languages

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

ECL Comfort V a.c. and 24 V a.c.

Heating and D.h.w. Controller RVL482 Basic Documentation

Electronic Pellet Burner Controller NPBC-V3-1

RVL479. Heating Controller. for use with a partner unit

Type summary Albatros 2

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

product overview ProControl

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

GA01HC-02. Service manual. Room Panel. Programme version 01a. Operating with GH07EA regulator for controlling electrode boilers

ECL Comfort 110, application 116

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 300 / V a.c. and 24 V a.c.

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

ST 53.1 User s manual

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Boiler controller Lambdatronic S 3200

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

SR-5/2D Solar-Power-Regulator

Electronic Pellet Burner Controller NPBC-V3M

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

english Steca Solar Thermal hot water from the sun. Solar Thermal

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

Do you want a versatile solution

Overview - Danfoss Link and living software versions

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Boiler controller S-Tronic Plus

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition

120+ Get your job done swiftly Easy selection of your application is the key. applications.

Vokèra OpenTherm 711 without external sensor connected

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Control solutions Biofloor

Operation Manual of Solar controller SR1568 for split solar system

Technical Data Manual

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Installation Guide. ECL Comfort 310, application A Table of Contents

SYX660 Commissioning Guide V Page 1 of 55

Installation Guide. ECL Comfort 210, application A Table of Contents

Heating Controller SDC Remote Heating Controller DHC

Temperature Control Systems

DeltaTherm HC * * Heating controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

Condensing Boiler RS100 Controller Training Program

Heating Controller SDC Remote Heating Controller DHC

OPERATING AND INSTALLATION INSTRUCTIONS

SYX66x Commissioning Guide V Page 1 of 61

Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat.

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 9. Packing list 9

Operating Instructions

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

Quickheat 30 weather compensated boiler control

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Use. Functions. Key function. Other functions

Semi flush-mount room thermostats

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Operating Instructions

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

PRELIMINARY EDITION

C B SOLARTHERMAL. Solar thermal systems

Installation and Operating Manual. Merlin 5064 V3. System Manager

District heating controller

Easy-Stat. Wireless Programmable Room Thermostat Pt No

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

RVL47. Heating Controller. Installations Instructions. Installation

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

Vokèra OpenTherm 711 with external sensor connected

Heating controller with optimisation functions

ELECTRONIC TEMPERATURE CONTROLLER FOR HYDRONIC HEATING SYSTEMS. SmartComfort LK 100 CT LK 110 LK 120 LK 130

Transcription:

www.seltron.eu 205 PROMATIC WDC Heating controllers Energy under control

36 Made for warmth.

PROMATIC WDC Heating controllers 37

PROMATIC WDC Heating controllers HIGHLIGHTS ycontrol of up to 52 different hydraulic schemes. ycontrol up to two heat sources. ycontrol of up to two mixing circuits. ysolar controller for d. h. w. warming. y warming functions. y4 language support. Party, Eco, Holiday and One-time domestic hot water PROMATIC WDC is a modern weather compensated heating controller with one or two mixing heating circuits, for domestic hot water warming with boiler and solar system and up to two heat sources. WDC is designed for demanding installations and allows user to choose among fifty-two pre-set hydraulic schemes. For a quick and easy start, a start-up wizard is installed, that guides user through the controller setting in only three to four steps. The controller can be switched to simulation mode, where you can simulate the temperatures of individual sensors and monitor the controller s response. 38

SIMPLICITY SOLUTION USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode. SELTRONHOME PROMATIC WDC controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen. ECO ECO operation mode ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode. One time domestic hot water warming The function switches on the water heating instantly. SETUP WIZARD The controller leads you in 3- or 4- steps through the first commissioning; all other parameters are pre-set. SYSTEM SIMULATION Holiday operation mode By pressing the HOLIDAY operation mode the heating is set at a specific energy saving temperature until the selected date. Anti-legionella program The controller ensures the medium is bacteriafree by periodically heating water to 60 C. The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation. INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc. HEATING SYSTEM PROTECTION PC INTERFACE The controller ensures periodical start-up of pumps and valves during inactive period as well as protection of the solar panels, and the heater against overheating or freezing. Through dedicated USB inverter the PROMATIC WDC weather compensted controllers can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment. 39

FEATURES WDC0B WDC0 WDC20 Number of mechanical relays 6 6 7 Number of electronic relays 0 Number of temperature sensors 7 7 7 Number of hydraulic schemes 7 7 52 Number of heating circuits - of which mixing circuits - of which direct circuits max max 2 Max. number of room units 2 2 2 Weekly program timer Switching between two boilers x x Room heating with heat pump D. h. w. warming with heat pump D. h. w. warming with solar collectors x BUS conection with other controllers Illuminated LCD display User functions Party, ECO, Holiday and instant d. h. w. warming Boost function for room heating Anti block function for pumps and valves Overheating protection for boiler and storage tank Antilegionella protection Frost protection Function for floor drying Overview of temperatures for current day Overview of temperatures for past week Error and high temperature warning Simulation of system operation Logging of settings changes Free programmable output x x x Control of 2-stage burner x x x Possibility of connection with PC SeltronHome remote control with Smart phone or Tablet max 2 2 40

WDC0B WDC0 WDC20 Solar collectors HEAT SOURCE Solid fuel boiler Boiler with pellet burner Oil boiler Additional electric heating Heat pump Gas boiler Combined boiler for liquid and solid fuel Control of constant stand- or return- pipe temperature REGULATED ELEMENTS 2-phase storage tank loading Heat accumulator Domestic hot water warming Domestic hot water circulation Direct heating circuit Mixing heating circuit Switching between direct heating circuit and domestic hot water Switching between two heat sources Radiators Floor heating 4

TECHNICAL DATA WDC0B WDC0 WDC20 Power supply 230 V ~, 50 Hz Consumption < 4 VA Consumption in standby max. 0,5 W Relay output 4 () A ~, 230 V ~ Triac output () A ~, 230 V ~ Degree of protection IP20 according to EN 60529 Safety class I according to EN 60730- Operation type B acc. to EN 60730- Temperature sensor type Pt000 or KTY0 Mixing valve control 3-point PID Controller housing ASA - thermoplastics Dimensions (w l h) 3 x63 x 48 mm Ambient temperature 0 40 C Storage temperature -20 C... +65 C Weight 42 g 42 g 49 g Package unit 2 pcs 42

SELF DIAGNOSTICS REPORTS In case of exceeding the maximum temperature or activation of protection function, the controller indicates the event with flashing symbol i on the display. If the maximum temperature is no longer exceeded or if the protection function is turned off, an illuminated symbol indicates a recent event. Press Help key to open the notifications log. HEAT CURVE SETTINGS 0 S=2,6 05 S=2,4 00 S=2,2 95 S=2,0 90 85 80 75 70 S=,8 S=,6 S=,4 S=,2 65 60 55 S=,0 S=0,8 50 45 S=0,6 40 S=0,4 35 30 S=0,2 25 20 20 5 20 5 0-5 -0-5 -20 Heating system Setting range floor heating 0,2-0,8 wall heating 0,6 -,0 radiator heating 0,8 -,4 With adjustment of the heat curve steepness, the controller is tuned with the building. For optimal controller operation, the right setting of the heat curve steepness is very important. BUS CONNECTION In the event of sensor failure, pump error or flow sensor error, the controller indicates the failure with flashing symbol! on the display. If the issue is resolved or no longer present, an illuminated symbol indicates a recent notification. Press Help key to open the warnings log. BUS BUS Using the BUS-connection, it is possible to establish a network of WDC controllers. CONNECTION OF ROOM UNITS 2 2 7 GND Up to two room units can be connected to a controller. 43

HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC WDC0B, WDC0, WDC20. 40 40b 40c 40d Oil boiler, mixing circuit, Heat accumulator, mixing circuit, Solid fuel boiler, mixing circuit, System without boiler - mixing circuit, 40e 402 403 BUS R3 R4 System expand - mixing circuit, Oil boiler, direct circuit, Oil boiler, direct circuit, The illustrated hydraulic schemes are supported in the following controllers: PROMATIC WDC0, WDC20. 404 404b 404c 404d Oil boiler, mixing circuit, d. h. w. storage tank, solar collectors. Heat accumulator, mixing circuit, d. h. w. storage tank, solar collectors. Solid fuel boiler, mixing circuit, d. h. w. storage tank, solar collectors. Heat accumulator with built-in storage tank, mixing circuit, solar collectors. 404e 404f 405 406 BUS R3 R4 Heat accumulator with built-in d. h. w. storage tank, mixing circuit, auxiliary heating with electricity, solar collectors. System expand - mixing circuit, d. h. w. storage tank, solar collectors. Oil boiler, direct circuit, d. h. w. storage tank, solar collectors. Oil boiler, direct circuit, d. h. w. storage tank, solar collectors. 407 407b 2 2 * WDC20 * Oil boiler, mixing and direct circuit Oil boiler,direct and mixing circuit, d. h. w. storage tank, solar collectors. 44

HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC WDC20. 408 408b 409 409b Wood boiler, oil boiler, mixing circuit, 40 Wood boiler, gas boiler, mixing circuit, 40b 40c Heat accumulator, gas boiler, mixing circuit, 4 Heat accumulator, oil boiler, mixing circuit, Heat accumulator, oil boiler, mixing circuit, 42 45b - 46b 46c 49 420 R3 Combined (wood/oil) boiler, d. h. w. storage tank, mixing circuit. 42 422b Combined (wood/oil) boiler, mixing circuit, 422 Heat pump, mixing circuit, d. h. w. storage tank, solar collectors. 422c Heat pump, heating support with electricity, direct circuit, d. h. w. storage tank. Heat pump, direct circuit, d. h. w. storage tank. 48 Oil boiler, heat accumulator, mixing circuit, Oil boiler, heat accumulator with builtin d. h. w. storage tank, mixing circuit. 47 R4 46 Wood boiler, oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank. Wood boiler, heat accumulator, mixing circuit, - Wood boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. R4 + Gas boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. + - R4 T8 - Combined (wood/oil), heat accumulator with built-in d. h. w. storage tank, mixing circuit. 45c + 44b + - Heat accumulator, oil bolier, mixing circuit, Combined (wood/oil) boiler, heat accumulator, mixing circuit, R4 + R4 44 Combined (wood/oil) boiler, mixing circuit, 45 Heat accumulator with built-in d. h. w. storage tank, oil boiler, mixing circuit. Pellet boiler, mixing circuit, 43 Heat accumulator, gas boiler, mixing circuit, Oil boiler, heat accumulator, mixing circuit, 422d Heat pump, heating support with electricity, mixing circuit, d. h. w. storage tank. Heat pump, combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. Heat pump, mixing circuit, d. h. w. storage tank. 423 + - 2 Oil boiler, 2x mixing circuit, 45

HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC WDC20. 423b 423c 423d 423e + - 2 + - 2 + - 2 + - 2 Combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. Gas boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. Heat accumulator with built-in d. h. w. storage tank, auxiliary heating with electricity, 2x mixing circuit. Heat accumulator, 2x mixing circuit, 423f 423g 423h BUS 2 2 + - + - + - 2 Wood boiler, 2x mixing circuit, Combined (wood/oil) boiler, 2x mixing circuit, System expand, 2x mixing circuit, 46

ORDERING CODES Controller PROMATIC WDC0B Code: 2WDC0B00000-00 Controller PROMATIC WDC0B incl. 2xTF/Pt, xaf/pt and xvf/pt Code: 2WDC0B200-00 Controller PROMATIC WDC0 Code: 2WDC000000-00 Controller PROMATIC WDC0 incl. 4xTF/Pt, xaf/pt and xvf/pt Code: 2WDC0400-00 Controller PROMATIC WDC20 Code: 2WDC2000000-00 Controller PROMATIC WDC20 incl. 4xTF/Pt, xaf/pt and xvf/pt Code: 2WDC20400-00 Surface sensor VF/Pt Code: VFPT-000 Immersion sensor TF/Pt Code: TFPT-000 Outside sensor AF/Pt Code: AFPT-000 Room unit RCD Code: RCD-040 Room unit RCDP Code: RCDP-040 Room unit RCD2 Code: RCD2-040 Room unit RCD2P Code: RCD2P-040 47