Commercial Thermostat

Similar documents
Commercial Thermostat Submittal Data

ATC32U01 igate Communicating, Programmable Thermostat

ATC32U03 igate Communicating, Programmable Thermostat

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Installer : Save these instructions for future use!

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

ACCESSORIES UNIT AND LOOP ACCESSORIES

Safety & Installation Instructions

TP-S-855i MENU AUTO HEAT. Installation Tips. Installation Manual. Installation Tips. Installation Tips. Hardwire - 24 VAC Common Wire

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

ACCESSORIES UNIT AND LOOP ACCESSORIES

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Integration Note OVERVIEW AND SUPPORTED FEATURES. Minimum Core Module Version: g! Document Revision Date: 2/14/2013

Safety & Installation Instructions

User s Manual

MAXIMUM UNIT AMPS MINIMUM WIRE SIZE

Instruction Guide: Thermostat Operation

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Installer : Save these instructions for future use!

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TP-S-855C. Installation Tips. Installation Manual. Installation Tips. Installation Tips

HEAT HEAT HEAT COOL COOL

HydroZone Installation Manual

Installation and Operating Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

ATC32U02 igate Communicating, Programmable Thermostat

T855S 5:23. Installation Manual. Installation Tips. Installation Tips. Installation Tips

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

Auxiliary Electric Heater Interface kit ASKHTR

Safety & Installation Instructions

Installation and Setup Guide

EWT-955WH. Wireless Type Selection. Installation Manual. Installation Tips. Installation Tips

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Installer : Save these instructions for future use!

ATC32U01 igate Communicating, Programmable Thermostat

DAY/TIME Button: Selects hour, minute and day setting.

Safety & Installation Instructions

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

ATC32U01A Communicating, Programmable Thermostat

Installer Guide. WARNING Important Safety Information. 1 Specifications

TP-Z-955W VIVE Comfort 1111 S. Glenstone Ave., Suite Springfield, MO 65804

EL-TSTAT-8820 Safety & Installation Instructions

Safety & Installation Instructions

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

iworx Air Side Application Wiring Guide

Safety & Installation Instructions

DAY/TIME Button: Selects hour, minute and day setting.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

ACDU02 Communicating Service Tool

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

Universal Programmable Wireless Thermostat Kit. See Wireless Setup Guide for Wireless Setup Instructions Read all instructions before proceeding

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

INSTALLATION & USER MANUAL

Owner s Manual. Part Number 33CSCPACHP-01

Installation Instructions

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

7-Day. Digital Thermostat. residential. & 2-cool

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

asy Single Day up to 2-heat & 2-cool Stat

TEC210x-2 Series Networked Thermostats

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

INSTALLATION AND OPERATING INSTRUCTIONS

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

Commercial Touchscreen Thermostat

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

Tranquility Digital Quick Start Guide

Installer Guide. WARNING Important Safety Information. 1 Specifications

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

Tranquility Digital Quick Start Guide

Siemens Thermostats. RDY2000BN Thermostat

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS200.

TH8320U and TH8321U Touch Screen Programmable Thermostats

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Smart Si Thermostat. Installation Manual

Thermostats Zoning Systems

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Homeowner s Guide / 1

ATC32U01 Basic Operation Guide

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Thermostats. Thermostats

CONTENTS. Installation Guide. VT7200 Series

Installation, Start-Up, and Operating Instructions

Transcription:

ommercial Thermostat Submittal Data *204* 204 ev.: November 18, 2016 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.

Table of ontents T-Stat Series ATA11U01 3 ATA11U03 4 ATA22U01 5 AT32U02 6 ATP21W02 8 ATP32U03 9 ATP32U04 11 AST008 13 11B0100N28 Wire Harness (6 Pigtail) 14 evision History 15 Document page number is shown next to part number (e.g. 204-3 = page 3). Since not all pages are typically used in limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-2

ATA11U01 Auto hange ver 3.30 in [83.8mm] : Turns continuous fan FF or N 4.55 in [115.6mm] Fault ight Temperature increase Temperature decrease ne Heat / ne ool Auto / Manual hangeover Non-Programmable Features (cont.): Extended fan operation feature can be used to operate fan for 90 seconds after turns off. Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. Mounting: 0.8 in Depth (20.3mm) 1.587in (40.3mm) Mode: Selects system mode - FF, HEAT,, or AUT 2.375in (60.3mm) Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. 2.625in (66.7mm) 3.275in (83.2mm) The ATA11U01 electronic thermostat provides singlestage, non-programmable temperature control for 24V water-source heat pump systems. Heat-ff-ool-Auto System selections. -n-auto selections. F or temperature display. onfigurable automatic or manual changeover operation. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. utput atings: Maximum current for each output is 1 Amp. Wiring: ATA11U01 Thermostat ompressor eversing Valve 24Vac ommon Fault ED ATA11U01 Thermostat ompressor eversing Valve 24Vac ommon Fault ED Heat Pump XM Heat Pump DXM / DXM2 /W2 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-3

4.12 in [105 mm] Back Plate: 2.88 in [73 mm].50 in [13 mm] The ATA11U03 electronic thermostat provides single-stage, 2 fan speed selections, non-programmable temperature control for 24 Vac water-source heat pump systems. 5.12 in [130 mm] Mode: Selects system mode - FF, HEAT,, or AUT 1.12 in Depth (28 mm) 4.40 in [118 mm] Heat-ff-ool-Auto System selections. ow or High selections. -n-auto selections. F or temperature display. Backlight user select. ATA11U03 Auto hange ver with Speed Switch 3.25 in [83 mm] Mounting Holes Temperature increase / decrease : Selects continuous fan FF or N and High Speed or ow Speed 3.56 in [90 mm] ne Heat / ne ool Auto / Manual hangeover Non-Programmable Features (cont.): Installer setup options allow for customized applications, including dead band adjustment, temperature display offset, manual heat-cool only, keypad lockout, sensing on board or remote, maximum cycles per hour, fan speeds (2 or 1), setting minimum cooling temperature, and setting maximum heating temperature. Zero temperature droop performance. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Backplate wiring for easy installation. Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). The default setpoint for heating is 68 F [20 ] and for cooling is 78 F [25.5 ]. Press the or keys to change the setting. To change between heat, cool, and auto settings, press the mode key until the desired setting appears. utput atings: Maximum current for each output is 1 Amp, 3 Amp total. Wiring: THEMSTAT ATA11U03 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-4 c h W 2 S2 S1 NTE 1 NTE 2 HEAT PUMP XM/DXM/DXM2 W W1 H (DXM N) or 1. For units using only 1 speed (see unit wire diagram.) Must add jumper on thermostat between and 2, or configure thermostat for 1 speed ( only). 2. For optional remote sensor, configure thermostat remote sensing, use ASW06 (wall sensor) or 17B0008N05 (duct sensor).

3.30 in [83.8mm] Mounting: : turns continuous fan FF or N 0.8 in Depth [20.3mm] 4.55 in [115.6mm] Fault ight Temperature increase / decrease Mode: Selects system mode - FF, HEAT,, EMHEAT, or AUT ATA22U01 Auto hange ver Two Heat / Two ool Manual / Auto hangeover Non-Programmable Features (cont.): Extended fan operation feature can be used to operate fan for 90 seconds after turns off. Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. Automatic fan staging (when used with DXM board and direct drive motor). Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. The ATA22U01 electronic thermostat provides two-stage, non-programmable temperature control for 24V watersource heat pump systems. Heat-ff-ool-Em Heat-Auto System selections. -n-auto selections. F or temperature display. onfigurable automatic or manual changeover operation. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. utput atings: Maximum current for each output is 1 Amp. Wiring: ATA22U01 Thermostat ompressor Heating Stage 2 eversing Valve 24Vac ommon Fault ED ATA22U01 Thermostat ompressor ompressor Stage 2 or Heating Stage 2 eversing Valve 24Vac ommon Fault ED /W Note 2 Heat Pump XM Heat Pump DXM/DXM2 W1 /W2 Note 2: onnect "W/" thermostat output to "" on the DXM if thermostat "" option is configured as " - n" and the desired operation is for 2 stages of compressor with no electric heat. onnect "W/" thermostat output to "W1" on the DXM if thermostat "" option is configured as " - f f" and the desired operation is for 1 stage of compressor with electric heat for Heating Stage 2. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-5

AT32U02 ommunicating 4.25 [108mm] Back Plate: 1.50" [38mm] - - - - UP 1.25 Depth [32mm] 3.12" [80mm] 3.25" [83mm] 6.25 [159mm] 0.62" [16mm] 3.00" [76mm] 2.12" [54mm] A+ B- ND D ND The AT32U02 iate ommunicating Programmable Thermostat provides 3 stages heating, 2 stages of cooling, programmable temperature/humidity control of 24V watersource heat pump equipment with DXM2 will communicate with heat pump to maximize comfort and reduce energy doing so. With DXM2 can set EM motor FM from minimum to maximum by 25 FMs; can view 6 unit sensors - Entering water, eaving water, Supply Air, Discharge line, entering and leaving TXV temperatures; check inputs and see dip switch configurations. Dehumidification output is designed to work with Whole House Dehumidification Modulating eheat option or with EM fan motor dehumidification mode Integrated control of both temperature and relative humidity ommunicating, Three Heat / Two ool, Auto / Manual hangeover Programmable (7 Day) - With Humidity ontrol Features (cont.): Integrated control eliminates separate thermostat and dehumidistat/humidistat Thermostat can be programmed to use humidification output to control a humidifier Digital Night Setback mode initiated by an external signal Four periods per day ºF or º temperature display 12 or 24 hour clock Individual heat and cool setpoints Zero temperature droop performance Automatic (program mode) or manual (HD) operation 7-day programming. onvenient overrides allow temporary setpoint changes Setpoints are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly arge backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with five navigation buttons (UP/DWN/EFT/IHT/SEET) for ease of use Fault indication with red backlight display onfigurable service interval messages and servicing contractor contact information Keypad lockout Simple four wire connection Back-plate wiring connections for easy installation Exclusive service screens that display conditions when fault occurred, last 5 faults, and list of possible causes ompatible with optional AST008 sensor for use as remote and/or outdoor sensor, or for indoor wall mounted sensor use ASW06. Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Setpoint range: 55ºF to 95ºF [12º to 35º], +/- 2ºF [1º] Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). Dehumidification setpoint range: 15% to 95% H Humidification setpoint range: 10% to 45% H limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-6

AT32U02 ommunicating Wiring: AT32U Thermostat Heat Pump DXM2 24 Vac ommon ommon + ommon - 24 Vac Hot A+ B- ND A+ B- 24V P4 Digital Night Setback Wiring: DXM / DXM2 ontrol See equipment wiring diagram for more details ptional Wiring for ASW06 AT ND D ND ND TEMP SW ED ASW06 (Indoor Wall Sensor) ptional Wiring for AST008 ATP (ocate utdoor) (ocate ND Indoor) D AST008 AST008 ND Note: AST or ASW can be mounted up to 200 feet from thermostat - use minimum two-conductor 22AW thermostat wire. Follow all NE and local electrical codes. utdoor sensor cannot be used if thermostat is configured for digital night setback. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-7

ATP21W02 Programmable 2H 1 3.81 in [97 mm] : sets fan to continuous N or AUT 5.14 in [130.5 mm] Temperature increase / decrease Two Heat / ne ool Manual hangeover Programmable Zero temperature droop performance. Manual changeover. onvenient overrides allow temporary setpoint changes. Setpoints are permanently held in memory (if batteries are used). oom temperature offset adjustment. Back section has wiring connections for easy installation. Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz Mounting: 1.25 in Depth [32mm] Programming Keys Mode: Selects system mode - FF, HEAT,, EMHEAT Temperature Settings: Setpoint range: 50ºF to 90ºF [10º to 32º] Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). Press the or keys to change the temperature setting. The MDE, PAM and HD keys allow changes to the program and schedule. utput atings: Maximum current for each output is 1 Amp..54 [13.5 mm] DISPA 1.25 [32 mm] 4.06 [103 mm].28 [7 mm] 1.62 [41 mm] WIE HE 1.18 [30 mm].75 [19 mm] 1.96 [50 mm] 3.81 [97 mm] Wiring: ATP21W02 Thermostat ompressor E eversing Valve /B 24Vac ommon Heat Pump XM/DXM DXM2 W THEMSTAT DIMENSINS (VE EMVED) 5.14 [130.5 mm] A DIMS ±.125 [3 mm] Wall Plate: 6.50 [165 mm] The ATP21W02 Thermostat provides 2 stages heating, 1 stage cooling, and programmable temperature control of 24V water-source heat pump equipment. Programming schedule includes one schedule for the five week days, one schedule for the two weekend days and four periods per day (5/2/4). 5-day/2-day programming. Four periods per day. ºF or º temperature display. Individual heat and cool setpoints. Features (cont.): 2.18 [55 mm] WA PATE ATWPF61 3.28 [83 mm] 2.25 [57 mm] 4.50 [114 mm] Note: rder Wall Plate ATWPF61 to mount thermostat to standard 2 x 4 electrical box (Includes metal plate for vertical box) limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-8

ATP32U03 Programmable 3H 2 4.25 [108mm] Mounting: UP 1.25 Depth [32mm] 3.12" [80mm] 6.25 [159mm] Three Heat / Two ool Manual / Auto hangeover Programmable (7 Day) onvenient overrides allow temporary setpoint changes. Features (cont.): Setpoints are permanently held in memory (no batteries used) and retained during power outages. oom temperature offset adjustment. Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly. arge backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds. Menu-driven programming with five navigation buttons (UP/DWN/EFT/IHT/SEET) for ease of use. Fault indication with red backlight display. onfigurable service interval messages and servicing contractor contact information. Keypad lockout. Back-plate wiring connections for easy installation. Exclusive fault identification (When used with XM, DXM or DXM2) displays fault from board (e.g. condensate overflow) and suggests possible causes. ompatible with optional AST008 sensor for use as remote and/or outdoor sensor, for indoor wall-mounted remote sensor use ASW06. Automatic fan staging (when used with DXM/DXM2 board and direct drive motor). 1.50" [38mm] 3.25" [83mm] 3.00" [76mm] 2.12" [54mm] Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz. The ATP32U03 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature control of 24V water-source heat pump equipment. 0.62" [16mm] 7-day programming. Four periods per day. ºF or º temperature display 12 or 24 hour clock. Individual heat and cool setpoints. Zero temperature droop performance. Automatic (program mode) or manual (HD) operation. Digital Night Setback mode initiated by an external signal (when using a DXM/DXM2 controller). perating onditions: 32ºF to 104ºF [0º to 40º]. 10% to 95% non-condensing. Temperature Settings: Setpoint range: 55ºF to 95ºF [12º to 35º], +/- 2ºF [1º]. Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). utput atings: Maximum current for each output is 1.0 Amp (2.0 max. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-9

ATP32U03 Programmable 3H 2 Single Stage Units onnection to XM ontrol ATP32U03 Thermostat ompressor eversing Valve 24Vac ommon Fault ED XM onnection to DXM/DXM2 ontrol ATP32U03 Thermostat DXM/DXM2 ompressor Note 1 eversing Valve 24Vac ommon Fault ED Single stage unit with PS or belt drive fan motor Note 1: may be used for High Speed fan for units with direct drive motor ptional Wiring for ASW06 ATP ND D ND ND TEMP SW ED ASW06 (Indoor Wall Sensor) ptional Wiring for AST008 ATP (ocate ND Indoor) D AST008 ND /W2 (ocate utdoor) AST008 Note: AST or ASW can be mounted up to 200 feet from thermostat - use minimum two-conductor 22AW thermostat wire. Follow all NE and local electrical codes. utdoor sensor cannot be used if thermostat is configured for digital night setback. Three Heat / Two ool Manual / Auto hangeover Programmable (7 Day) Units With EM Board (TT and T) onnection to EM ontrol ATP32U03 Thermostat ompressor ompressor Stage 2 eversing Valve 24Vac ommon Fault ED Units with XM or DXM board and EM fan motor Two Stage Units onnection to XM ontrol Board #1 ATP32U03 Thermostat XM ompressor ompressor Stage 2 eversing Valve 24Vac ommon Fault ED Two compressor unit with XM boards onnection to DXM/DXM2 ontrol Board #1 ATP32U03 Thermostat DXM/DXM2 ompressor ompressor Stage 2 eversing Valve 24Vac ommon Fault ED Two compressor unit with DXM boards Digital Night Setback Wiring: EM Board #2 XM Board #2 DXM/DXM2 /W2 /W M 1 M 1 S S DXM / DXM2 ontrol See equipment wiring diagrams for more details. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-10

ATP32U04 Programmable 3H 2 with Humidity 6.25 [159mm] Three Heat / Two ool, Auto / Manual hangeover Programmable (7 Day) - With Humidity ontrol Features (cont.): 4.25 [108mm] Mounting: 1.50" [38mm] 1.25 Depth [32mm] UP 3.12" [80mm] 3.25" [83mm] 0.62" [16mm] 3.00" [76mm] 2.12" [54mm] Four periods per day ºF or º temperature display 12 or 24 hour clock Individual heat and cool setpoints Zero temperature droop performance Automatic (program mode) or manual (HD) operation 7-day programming. onvenient overrides allow temporary setpoint changes Setpoints are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly arge backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with five navigation buttons (UP/DWN/EFT/IHT/SEET) for ease of use Fault indication with red backlight display onfigurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identification (When used with XM, DXM, or DXM2) displays fault from board (e.g. condensate overflow) and suggests possible causes ompatible with optional AST008 sensor for use as remote and/or outdoor sensor, or for indoor wall mounted sensor use ASW06. The ATP32U04 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature/ humidity control of 24V water-source heat pump equipment. Dehumidification output is designed to work with Whole House Dehumidification Modulating eheat option or with EM fan motor dehumidification mode Integrated control of both temperature and relative humidity Integrated control eliminates separate thermostat and dehumidistat/humidistat Thermostat can be programmed to use humidification output to control a humidifier Digital Night Setback mode initiated by an external signal (when using a DXM/DXM2 controller). Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Setpoint range: 55ºF to 95ºF [12º to 35º], +/- 2ºF [1º] Note: User must maintain thermostat setting within proper unit operating temperature range (See specific unit(s) IM for details). Dehumidification setpoint range: 15% to 95% H Humidification setpoint range: 10% to 45% H utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-11

ATP32U04 Programmable 3H 2 Humidity Wiring: Units with limadry eheat ATP32U04 Thermostat ompressor Dehumidification eversing Valve 24Vac ommon Fault ED Electric Heat DH W1 Single stage unit with limadry Modulating eheat ption and PS fan DXM/DXM2 H /W2 W onnection to DXM/DXM2 ontrol ATP32U04 Thermostat DXM/DXM2 ompressor ompressor Stage 2 Dehumidification DH H eversing Valve /W2 24Vac ommon Fault ED Electric Heat W1 W Two-stage unit with limadry Modulating eheat ption and DXM/DXM2 board Digital Night Setback Wiring: Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) With Humidity ontrol Units with EM Board (TT and T) onnection to EM ontrol ATP32U04 Thermostat ompressor ompressor Stage 2 Dehumidification eversing Valve 24Vac ommon Fault ED Electric Heat DH W1 Units with XM or DXM board and EM fan motor, utilizing EM dehumidification mode (w/o limadry option) Notes: 1) EM dehumidification mode slows down fan speed in the cooling mode when dehumidification output from thermostat is active. Normal heating and cooling fan speeds are not affected. 2) EM board DIP switch SW9 must be in dehumid. mode. ptional Wiring for ASW06 ATP ND D ND ND TEMP SW ED ASW06 (Indoor Wall Sensor) EM DH W DXM / DXM2 ontrol ptional Wiring for AST008 ATP (ocate ND Indoor) D AST008 ND (ocate utdoor) AST008 See equipment wiring diagram for more details Note: AST or ASW can be mounted up to 200 feet from thermostat - use minimum two-conductor 22AW thermostat wire. Follow all NE and local electrical codes. utdoor sensor cannot be used if thermostat is configured for digital night setback. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-12

AST008 Sensor emote/utdoor Temperature Sensor The AST008 sensor is a thermistor, used as an accessory for thermostat models ATP32U03 and ATP32U04. This sensor provides outdoor air temperature information for the control system, as well as an indication of outdoor temperature on the display screen. The AST008 sensor can also be used as a remote indoor sensor. Two sensors may be used--one for remote indoor temperature sensing, and one for outdoor temperature sensing. When the sensor is used as a remote indoor temperature sensor, the internal sensor of the thermostat becomes inactive. (No thermostat reconfiguration required). Two-wire connection to thermostat, extendable with two-conductor 22 AW thermostat wire up to 200 feet. Mounting clip included Wiring: ATP32U0_ Thermostat Terminal Block ND D AST008 ND Position Sensor Indoor (i.e. in return air duct) Position Sensor utdoor AST008 Designed for indoor or outdoor installation. May be used as indoor remote temperature sensor or as outdoor temperature sensor. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-13

11B0100N28 Wire Harness (6 Pigtail) Wire harness can be connected to any thermostat for quick connection to heat pump units with whip. Pigtail Whip HEAT PUMP Thermostat Quick onnect Molexes (9 Pin) IB W or 2 Molex - Wire End position 9 is open Thermostat (Not all wires required for all thermostats - ap unused wires) Pigtail Note: Thermostats can be ordered with Pigtail factory attached A9155801 - ATA11U01 A9155802 - ATA11U03 A9155804 - ATA22U01 A9155805 - ATA32U03 A9155806 - ATA32U02 A9155809 - ATP21W02 (attach to wall) A9155810 - ATP21W02 (attach to 2x4 horizontal box) A9155811 - ATP21W02 with plastic back plate (attach to 2x4 horizontal or vertical box) Whips can be ordered as special, consult factory. 15, 25, 35 or 45 feet length 8 conductor 18A 2 thermostat cable with or without BX sheathing. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-14

evision History Date: Item: Action: 11/15/16 Document Design Update Updated 04/22/15 Text Edit - All Pages; 11B0200N28 Updated & Added 12/03/14 ATP21W02; Misc Text - All Pages Added 03/26/14 AT32U02 Added 12/11/13 ATA11U01 Updated 02/28/13 AST008 Updated 02/25/13 ATA11U03 Added 11/26/12 ATA1104 and AST009 emoved 02/16/12 ATA1106 emoved 01/26/12 ATP32, ATP21, AST008, AST009 Updated 04/26/11 ATP32U03 & ATP32U04 Featuresp Updated 01/03/11 Format - All Pages Updated 09/01/10 ATP32U03 & ATP32U04 Temperature Settings Updated 06/11/10 Format - All Pages Updated 07/06/09 AT1N01 emoved 05/21/09 ATM1104 emoved 05/11/09 ATP32U04 Information and Pictorials Added to Page 12 05/11/09 AT1101, ATT1101 Page emoved 05/11/09 ATP31U02 hanged to ATP31U04 05/11/09 ATP31U01 hanged to ATP31U03 10/31/08 ATM1104 Added 09/16/08 ATP32U2 Updated Wiring ontrols 07/31/08 AT1101, ATT1101 Information Added 07/23/08 ATA1103, ATA1104 Note 3 Added 05/01/08 AT1 Updated Verbage and hanged Pictures 10/18/07 ATP32U01 Added 2 DXM wiring diagram 10/18/07 ATP21U01 emoved Auto mode notation 10/18/07 ATM1111 Added model 03/31/06 AST008 Added AST008 outdoor/remote sensor 02/23/06 First Published limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. 204-15