Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Similar documents
Funnel Casing -- ZENON, I M NOT SURE WHAT THIS IS. I CAN DELETE REF- ERENCE TO IT OR PROVIDE SOME DETAIL IF YOU CAN HELP ME UNDER- STAND IT.

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 500

Operating manual. Wood gasification boiler at kw. Orlan STANDARD, SUPER IRL

ISO 9001 TUV CERT CE

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

INSTRUCTION MANUAL & SERVICE MANUAL. ORLAN SUPER kw. Orlan

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

Operation and maintenance manual for the. KSP Spark. series boilers equipped with feeders

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 200

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

PELLET BURNER PV 350

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATION MANUAL

modern heating devices

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

MANUAL. Page 1/44

Electronic Pellet Burner Controller NPBC-V3-1

USERS MANUAL FOR GAS BOILERS

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Technical documentation: S1 S2 S3 S4

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

ecomax 800, model R1 Boiler regulator Dzia Zintegrowanego Systemu Zarz dzania version: ec FOR SOLID FUEL-FIRED BOILERS WITH FEEDING SCREW

Electronic Pellet Burner Controller NPBC-V3M

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Eco Angus Wood Pellet Boilers

USER MANUAL 9kW LILLY PELLET STOVE

MANUAL AND SERVICE MANUAL ORLIGNO 100

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

TECH. Declaration of conformity no 23/2007

it warms us up! PRICE LIST

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Light oil - kerosene burner

Cm Pelet-set - touch TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT

Cm Pelet-set (60-90 kw)

1 VICTRIX ZEUS Superior kw I features

PER-EKO type KSW & KSW PLUS Instruction Manual

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

KOSPEL S.A. UL. OLCHOWA KOSZALIN

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Cooker Hood LA-72-CAN.

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

EN Instruction on mounting and use

Corn Flame Energy Corn Stove Model 3000

OPERATING INSTRUCTIONS with safety features

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Easyfire Standalone biomass pellet boiler

Declaration of Conformity No. 27/2008

Instruction manual for downdraft hood

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Service Manual. Unit: Pellet burner. Type: ROT-POWER. Models: kw, kw

PELMAX HEATING BOILER FOR SOLID FUEL

Technical documentation DTR

Operating instructions

TABLE OF CONTEST. page 1

Aquaflam Wood boiler stoves and fireplace inserts

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Gas heaters and convectors ROBUR

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

1. The structure and its description

Operating instructions

Index I. INSTALLATION DIAGRAM... WIRING DIAGRAMS...

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Instruction Manual JLHDA cm Cooker hood

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Operation and maintenance manual. for the KSM series boilers with feeders

Installation, operation and care. Pellmax UB. Burner not included Replaces:

INSTALLATION AND USER MANUAL

Unit: Pellet burner Type: ROT-POWER

MODERATOR Vento Eko 15,20,25 kw

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

Burner Controller S.Control

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Inverter Swimming Pool Heat Pump

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

ARITERM OY. Arimatic 500. User manual

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

ENTROPIE boiler TT300

Ladan. Wood gasification boiler. Instruction for use, installation and assembly of boiler.

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Transcription:

Operating manual Pellet boiler Orlan Pellet ISO 9001

Contens 1. Boiler s use...................................................................... 3 2. Boiler s way of working........................................................... 3 2.1. Burning up............................................................. 3 2.2. Appropriate operating.................................................. 4 3. Regulator description............................................................. 5 4. Use............................................................................. 5 5. Technical data................................................................... 6 5.1. Boiler sizes............................................................ 6 5.2. Technical data......................................................... 7 5.3. Technical data of regulator.............................................. 7 5.4. Electrical data of gear- motors........................................... 8 5.5. Mechanical data of gear-motors......................................... 8 6. Hydraulic connection of a boile.................................................... 9 6.1. Connection scheme.................................................... 9 6.2. Hydraulic connections description....................................... 9 7. Loading system................................................................. 10 8. Protection against flame getting into the container.................................. 10 8.1. Acceptable fuel temperature excees in the feeder......................... 10 8.2. Fuel loading outage................................................... 10 9. Ventilation in a boiler room....................................................... 10 9.1. Supply ventillation..................................................... 11 9.2. Exhaust ventilation.................................................... 11 10. Connecting boiler to the chimney................................................. 11 11. Utilizing........................................................................ 12

1. Boiler s use Low-temperature pellet boilers produced by Eko-Vimar Orlański company are for water heating in central heating and for combustion of pellet at sizes: diameter- 6 up to 8 mm; length 10 up to 50 mm. Pellet s container allows for long lasting burning process with no extra loading necessity. Pellet boiler is to be installed in open pressure vessel system assuring boiler s working in nominal working pressure. The boiler is equipped with a controller enabling boiler s working at right temperature s range and it secures the boiler against its overheating thanks to burner s exhaust fan switching on. 2. Procedure rule of pellet boiler 2.1. Burning up STOP OPERATING PUMP FEEDER MIXER START Regulator before turning on 1. Fill In the container with pellet and close the cover tight 2. Connect the plug with a connector at 230V/50Hz, then connect the controller with a network switch NOTICE! Connection socket should be secured with the 4A fuse and anti-shock switch (max power 20 ma ). NOTICE! It is forbidden to connect other appliances to the system!!! 3. Turn on with START button(5). Turning on with START cause also demister and feeder s turning on. When temperature reaches the needed one- demister and feeder turn off automatically.

When the regulator starts working, there is a display as below: Current time Time zone 12:23 Strefa:4 Temp:25.6 Nast:52 water s temperature in the boiler Temperature setted 2.2. Appropriate operating When all of the points above are accomplished, the controller ensures: 1. Keeping permanent temperature of the boiler - set by the user temperature of the boiler by automatic connecting of blow and feeder. 2. Self- turning off of the demister right after fuel ending. 3. Continuous boiler s temperature, time and eventually time zone checking. At the front panel there are control lights (2) telling about the controller s operating: I. STOP - signals the controller s working ending it s on automatically in case of fuel shortage II. FAN - signals about the blower s turning on III. HEATER - electric heater turning on IV. FEEDER 1 - signals about the fedder 2, V. FEEDER 2 - signals about the fedder 1 connecting 2 VI. START - signals about boiler s burning up mode turning on. It turns off automatically right after reaching by boiler the temperature previously set 12:23 Temp: 25.6 Zone:4 Setting: 50 REGULATOR WORK DISPLAY Fire maintaining 3 min. 10 sek. Set the clock 14:50.43 Set the date 2004-01-20 Time zone 1 10:45 Temp.: 45 C Time zones ON Time zone 6 16:30 Temp.: 50 C Time zones setting Setting OUT Setting OUT Segmental scheme of regulator s menu.

3. Regulator description. 3 Fuse 3.15 A 1. Regulator ON switch, 2. Signalization indicator, 3. Screne, 2 1 4 5 6 4,5,6. Keypad buttons for the appliances operation: 4,6 - change of the parameter chosen value (cursor highlighted ) ex: temperature setting. The buttons are for moving among the parameters in the MENU. 5 - in normal working mode START / STOP button. Long holding ( about 2 sec) gives an access to the MENU. When MENU programming it s possible to confirm the previous setting choice with the buttons 4,6. 4. Use The appliance s main use is automatic controlling of boiler s operation. By controlling we mean water s warmth controlling. Algorithm of working enables for time intervals defining (called as Time intervals ), where the boiler should keep water s temperature set by the user. Such function gives an opportunity of more effective temperature s regulation (ex. cooler at night and warmer during the day) and as it follows - it decrease the fuel s taking.

5. Technical data of the boiler. 5.1. Boiler s sizes

5.2. Technical data No. Description Unit Value 1. Boiler s power kw 30 2. Power range kw od 8 do 30 3. Power consumption W 250 4. Max water temp. C 90 5. Fumes temp. C 150 6. Water capacity dm 3 60 7. Weight kg 300 8. Container s capacity dm 3 135 9. Chimney flue diameter mm 160 10. Max pressure MPa 0,2 11. Chimney thrust needed Pa od 10 do 20 12. Boler s efficiency % 92 13. Heated space m 2 do 300 One loading working time 14. 8 kw burner s working h 90 15. 15 kw burner s working h 55 16. 30 kw burner s working h 30 5.3. Technical data of a regulator No. Description Unit Value 1. Temperature regulation range C 35-90 2. Water s measurement range C 0-95 3. Fumes measurement range C 0-600 4. User communication Alfa-numeric LCD screne 6. Burning maintaining regulation min. 9. Flow blow s regulation 10. Boiler working programming 11. Fumes temperature control 12. Operating in surroundings temperature C 0-50 1-5 stopover 1-60 Panning (possibility of service mode turning off) Max 6 time zones established by the user in 24 hour time Fumes control enabling for more economic and safer boiler s using 13. Second grade of thermal safety standy thermostat (STB - 95 C) 14. When power shortage Automatic setting keeping when power shortage

5.4. Electrical data of gear- motors No. Description Value 1. Type commutator motor with a gear 2. Voltage AC 230 V 50 Hz 3. Fields quantity 2 P 4. 5. No charge engine characteristics Loading characteristic - 1 min after the engine s starting working 6. Max power 1,2 A MAX. 7. Dialectic stamina 4.1. Current 0,65 A ± 15% 4.2. Initial power 72 W ± 15% 4.3. Rotation power 5,4 rot/min ± 10% 4.4. Voltage 161 V MAX 5.1. Limit load 33 Nm MIN. 5.2. Acceptable load 25 Nm MlN. 5.3. Start loading 20 Nm MIN. An engine takes 1500V RMS voltagew in 1 minute time (1800V RMS by 1 sec) measured between engine s coil and its core (trial current 3 ma). 8. Insulation constant 100 MΩ min at 500V constant equivalent measured between a coil and casing 9. Thermal protection Thermal secured engine (up to 120 C) 10. Insulation category category E 5.5. Mechanical data of gear-motors No. Description Value 1. Lubrication mineral oil & grease 2. Volume 25 db MAX (no charges) 3. Weight 2,2 kg 4. Driveshaft s placement horizontal 5. Ratio 1 : 532 6. Bearings ball bearings

6. Hydraulic connection of the boiler 6.1. Connection scheme 1. Boiler with pellet feeder 2. Pump 3. Feeding distributor 4. Three- way mixing valve 5. Circulating pump 6. Differential valve 7. Returning distributor 8. Radiator 9. Tap water circulating pump 10. Tap water container 11. Tap water outlet 12. Cold water inlet 6.2. Description of hydraulic element connecting Installation s power - DN 50 Cooling coil terminal - 2 DN 20 Return from installation - DN 50 Ferrule - DN 15

7. Loading system 8. Protection against the flame getting into the container 8.1. Acceptable fuel temperature excees in the feeder Controller is equipped with safety thermostat which turns the boiler off when it excees the fuel s acceptable temperature. It measures the feeder s pipe. The controller alarms and in the same time turns off the boiler when the temperature excees 95 C. NOTICE!!! Standby resetting is manual by pressing the button at safety thermostat. Before standby resetting it s necessary to find the overheating reason and to get rid of it. 8.2. Fuel loading outage Scheme of pellet s loading and its burning Pellet feeding system is constructed in the way as to let the flames to get into container. Two feeders joined with a chute pipe ensure safe pellet s feeding. Boiler regulator ensures right operating of the both feeders. The feeders co-operate together in the way that the vertical spilling pipe sector is always empty and that assures stopping of pellet s feeding continuity. 9. Ventilation in a boiler room Every boiler room should have a ventilation built-in. Its purpose is to ensure right boiler s working and safety for the users. Lack of ventilation causes boilers faulty working ( smoke, problems with higher temperature achieving).exhaust ventillation s purpose is to remove gas and the used air out of the room. In the boiler room with natural thrust mechanical ventillation cannot be applied. 10

9.1. Supply ventilation 1. Supply ventilation conduit s sizes should be equal 50 % of chimney cross-section, it can t be less than 20x20 cm. The duct should be placed 1m over the floor. 2. In the intake slot or in the conduit there should be an appliance air flow controlling. The appliance however cannot limit the cross - section to more than 1/5 of total space. Ventilation flue should be made of non- flammable material. 9.2. Exhaust ventilationo 1. The conduit s size needed - 25% of the chimney sectional view - should be bricked (min 25% of the chimney s sectional view) however it cannot be smaller than 14 x 14 cm. Any of the appliances cannot block the chimney inlet slot. Exhaust slot should be placed under the ceiling and it should be at least 1,5 m over the roof. 2. Ventilation flue should be made of non - flammable material. Boiler room should be at least 2,2 m high. 10. Connecting boiler to the chimney Chimney conduit should be made in conformity with PN-87/B-02411 and PN-89/B-10425 norms Smoke, combustion and ventillation conduits made of the brick. Requirements and checking on acceptance test and Infrastructure Minister s regulation from the 12.04.2002 (Journal of Laws no. 75). The segment of fuse discharging is called chimney flue. To decrease fumes flow resistance chimney flue should be arranged as straight one and if there is a necessity of its changing the changes should be made softly - as 45 curves. Because of the fumes temperature boilers can be assembled in chimney flue which is made of brick with smoothed interior walls. The chimney flue itself should be build starting with the boiler room s floor because the fuse coming out of the boiler should be able to turn back. About 30 cm above the floor there should be an airtight closure washout hole. To limit fumes flow the chimney s cross - section should be round or similar to the square shape. Min hydraulic diameter of the chimney is 160 mm. Chimney should reach out of the roof. Chimney outlet placement depends on the roof tilt range and its flammability range. Chimneys at up to12% hipped roof end s tilt range should stick 0,6 mm out of the roof ridge. Boilers above 12 angle of depression should stick out of the roof edge: in case of inflammable roof cladding - 0,6 m, in case of non or hard - flammable roof cladding the exhaust can be placed about 0,3 m above the roof edge. Producer prescribes montaging of chimney flue regulator which in case of too large underpressure in the chimney opens and withdraw the air by suction boiler doesn t take it in. 11

11. Utilizing The appliance is approved according to the European Directive 2002/96/EC in the matter of electrical and electronic devices waste(weee). Ensuring right its scrapping you help to protect the environment. The symbol placed either on the device or in the documents enclosed means that the product isn t classified as a household waste. The appliance should be taken to an authorized collection point in the matter of electric and electronic components recycling. Pellet boiler should be scrapped according to local regulations according waste utilization. More informations according utilization, scrapping and recycling you can get in the local city hall, in civic waste utilization company or in the place of he machine buying. e-mail: orlanski@eko-vimar.com.pl www.eko-vimar.com.pl tel.: +48 77/ 400 55 80 81, 400 55 91 fax: +48 77/ 439 05 03, 400 55 96 EKO-VIMAR ORLAŃSKI 48-385 Otmuchów / woj. opolskie POLSKA ul. Nyska 17b IO_PE_E_61113 12