GV Standard X-Vent Operation and Maintenance Manual

Similar documents
Manually hinged ventilation rooflight

WaterSwitch Extended Range. User Guide

Product information Flat glass product ISD for VELUX flat roof windows CFP/CVP Integra

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

The Professional s Choice

Imperial Electric Fires

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Read our technical blog at glazingvision.co.uk/blog. Our rooflights can be found all over the world in over 20 different countries

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

INSTALLATION AND USER INSTRUCTIONS COUNTERTOP AND FREE STANDING FRYERS

ASSEMBLY & OPERATING INSTRUCTIONS

Read our technical blog at glazingvision.co.uk/blog. Our rooflights can be found all over the world in over 20 different countries

Eldon Product Overview

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CERT 7795 Fully certified to AS2658:2008. Part No. COMP825 OWNERS MANUAL

Specifying the Right Rooflight. T: +44 (0) E:

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS

WIRELESS WaterSwitch

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Infra Red Basin Tap IR120CP.1 & IR121CP.1

Hazardous Area Portable Fan Heater The Bulldog

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

Hazardous Area Portable Fan Heater The Bulldog

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

DCS-100. intelligent damper control & monitoring system

LeakSafe. solutions. WaterSwitch2. Installation Instructions

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

FIRERAY 5000 range USER GUIDE

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

USER MANUAL CEF AP28 CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Fire detection and alarm

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

EMERGENCY ASSISTANCE ALARMS

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Service Manual. Model UL Part Number XLF XLF XLF

Installation and user manual for the BiWire / Conventional Repeater Panel

Interface Modules for SENTRI

Hazardous Area Portable Fan Heater The Bulldog

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

GCG-26c. Instruction Manual. G-Series Cooler

USER MANUAL & MAINTENANCE GUIDE OG OO

BATHROOM FURNITURE FITTING GUIDE

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Fill Point, Level Gauges, and Control Range

Fitting and Operating Guide plus Maintenance Test Record

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

HW3 Handwash Installation and Operating Instructions

Copyright September 2018 Future Products Group Limited. All rights reserved.

Ambient Cabinets Curved Format

Drying Cabinet Installation and Operating Manual

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Control Panel User Guide

IDM4 CARAVAN ALARM. Operating instructions

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Installation and Operating Manual Drying Cabinet

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

Monitoring Devices 11/1

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Mira Platinum Wireless Controller

Intelligent Security & Fire Ltd

MODEL NO: MC02 BATCH NO: PR3547

Instructions for the fan motor control system, SILVER C

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Performance Specifications LSF LIFT-SMOKE-FREE

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Popcorn Warmer Cabinet

LeakSafe. solutions. WaterSwitch2. Installation Instructions

5 Sounds and Indications

Operation & Maintenance Manual

Imperial Electric Fires

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

FWC860 Wine Cooler Installation, Use and Maintenance

SILO PROTECTION SYSTEMS

EDD61 & EDD91 Extractors

Smoke Vent Control Panel PCB4 V4 Installation Manual

Installation Manual EF5000 AUS & NZ

Basic Vehicle Fire Protection Manual

OPERATING INSTRUCTIONS: Under Counter

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Transcription:

GV Standard X-Vent Operation and Maintenance Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

GV Standard X-Vent Operation & Maintenance Manual XV-OM v2.1 11.01.17 Page 2 of 10 Contents Section Description Page Contents and introduction 2 Controls and operation 3 Basic X-Vent operation 5 Back up battery 5 Routine testing 6 Cleaning the X-Vent 6 Troubleshooting 7 Standard glass specification and breakage 7 COSHH and safe disposal 8 Certification 9 Warranty information 10 Introduction Thank you for purchasing a Glazing Vision X-Vent (Figure 1). The X Vent is available in standalone Solo and Integrated formats. The X Vent is a safety critical product. It has been designed and tested to BS EN 12101-2:2003. As such it should provide years of trouble free service with minimal maintenance. Figure 1 X-Vent

Page 3 of 10 Controls and Operation Control Switch: The standard operation of the unit is via the supplied wall switch (Figure 2) and can be operated using two different methods as explained below: Status light Figure 2 Wall mounted control switch 1. One touch operation Press and release the control switch once in either the up or down direction; the rooflight will open or close fully. Partially open positions can be achieved by pressing the control switch again during the open or close cycle. 2. Conventional hold operation Press and hold the control switch until the rooflight has reached the desired position, releasing the switch stops the rooflight in that position. Note: the rooflight will stop when it becomes either fully open or closed. Status Light: The status light will illuminate green if the rooflight is functioning normally. If the status light displays another colour please refer to the troubleshooting section. Fire alarm system (Mandatory) The X Vent is supplied with a trailing cable for connection to an external fire alarm system. It is the fire alarm that will trigger the X Vent to open to the Fire Open position (see Basic X-Vent Operation). Remote Control (Optional): The remote control unit (Figure 3) functions in the same way as the control switch but allows you to open and close your rooflight from a short range. The remote control is powered by two AA batteries. To replace the batteries, remove the small hex screws found on the rear of the remote to allow access inside (please note there is a free end wire antenna coiled within the remote). Figure 3 Remote control

Page 4 of 10 Rain Sensor Operation (Optional): The rain sensor (Figure 4) automatically closes the rooflight when it rains. If moisture is detected on the rain sensor when rooflight is opened, a special built in heater activates for 60 seconds to evaporate standing water. If after 60 seconds water is still detected, the rooflight will close. This feature enables the rooflight to differentiate between rain and standing water / morning dew. Figure 4 - Rain sensor Security System Connection (Optional) The X Vent can be supplied with a cable for connection to an external security system as an optional extra. The cable is connected to a micro switch mounted inside the X Vent. The switch closes when the lid is in the closed position. Building Management (Optional): The X-Vent can be connected to building management systems. Please contact Glazing Vision Ltd for further details if required.

Page 5 of 10 Basic X-Vent Operation The X-Vent has three prime positions; closed, vent open and fire open. These correspond to 0º, 45º and 140º lid openings respectively. Under normal operating conditions the X Vent will travel between the vent open and closed positions. It can be stopped in any intermediate position and will respond to the full range of input controls listed above. This means that the X-Vent will not open beyond 45º under the control of the wall mount control switch. The X-Vent is fitted with an ambient air temperature sensor as standard. This sensor serves as a backup to the fire alarm system. If the sensor detects ambient air temperature of 72ºC it will trigger fire behaviour. Fire alarm activation will also trigger fire behaviour. Under fire conditions the X-Vent will immediately respond by travelling to the fire open position. This will happen regardless of the status of any of the other control devices. Whilst the fire conditions are held the X-Vent will remain in the fire open position and will ignore all other input devices. Control will be returned to the wall mounted control switch after a 180 second delay, the temperature sensor is below the trigger point and the fire alarm input is inactive. On resetting the fire alarm, if the temperature sensor is below its trigger point control is returned to the wall mounted control switch. Once the X-Vent has been manually closed beyond the vent open position (i.e. to an angle less than 45 ) control is returned to all system inputs. Hence recovery from fire alarm activation must be by manual operation, and closure can be in stages i.e. the rooflight can be closed in a series of close operations. Back up Battery The X Vent has a back-up battery housed inside its base. Under normal conditions the control board will trickle charge the battery which is isolated from electrical loading. Only when the incoming supply to the control board is lost will the battery will be switched in automatically. When operating under battery all appropriate system inputs will be allowed to close the X Vent. Once closed, or if already closed, the X-Vent will only open under fire behaviour. Whilst running from the battery the X-Vent will emit a periodic audible warning. Battery operation is also indicated by a flashing red LED on the wall mounted control switch. The LED will flash when the switch is pressed in either open or close directions. A continuous red LED indicates that the battery is at low level. See section on troubleshooting.

Page 6 of 10 Routine Testing As the X-Vent is a safety critical product it is anticipated that it will be subject to a regular testing regime. This is the reason why, following fire activation, it has been made necessary to close the X-Vent manually using the wall mounted control switch. In this way it is possible to walk to each X-Vent in the property, confirm that it has opened to the fire open position, and then check that the X-Vent closes with no faults present (i.e. green LED on wall mounted control switch). Cleaning the X-Vent Due to the X-Vent s unique bonding method and the slight pitch built into the kerb, there should be no water ponding on the glass when installed correctly. Any standard glass cleaning product can be used to clean the glass unit. However take care not to use abrasive materials or cleaners as this may affect the unit and its finish. The framework of the unit can be cleaned using warm soapy water with a soft lint free cloth. It is important to avoid getting water into the internal channel of the rooflight framework. Therefore we highly recommend carrying out any cleaning of the rooflight whilst in the closed position.

Page 7 of 10 Troubleshooting The X-Vent control board monitors the operation of the vent. If a fault is detected, the board will disable the vent to prevent possible damage. Fault and standard conditions are indicated by the status light on the control switch (Figure 2). The following table shows the various status light displays and their meanings: Status light shown Continuous Green Intermittent Green Continuous Blue Intermittent Blue Meaning Displayed whilst rooflight is in motion with no faults present. If rooflight is one-touch opened or closed LED will remain lit until motion stops. Flashes whilst rooflight closes due to rain sensor. Flashing will stop when motion stops. Indicates an IO fault, i.e. a mechanism timing fault. LED remains lit and control switch is disabled until control board is reset. Indicates an overcurrent or undercurrent condition. Flashes and control switch is disabled until control board is reset. The batteries supplied with the X Vent are sealed and maintenance free with a design life of 12 years. On the basis that the X Vent operation is restricted to fire behaviour while running under battery the low battery state should not arise often. If the low battery state persists for more than 24 hours please contact Glazing Vision to arrange for replacements to be fitted. Standard Glass Specification and Breakage Instructions Glass Specification The standard glass used within the Skydoor comprises a 6mm HST toughened outer pane, a 20mm warm edge spacer argon filled black silicone sealed cavity and a 4mm HST soft coat Low E toughened inner pane. However various options are available at time of order. If specific data is required for the glazing please contact Glazing Vision for a glass data sheet for the specification installed within your rooflight. Breakage Instructions Should the double glazed unit break for any reason, due to the unique method of bonding the glass unit into the frame, a new lid would need to be supplied. Glass breakage is not covered under the product warranty unless the breakage is a direct result of Glazing Vision Limited or its product failing. In the event of the glass being damaged please contact Glazing Vision for assistance.

Page 8 of 10 COSHH and Safe Disposal There are no hazardous materials used in the construction of the Skydoor. Wherever possible when disposing of the Skydoor recycle as much as possible. Do not burn any plastic materials. The following materials are used throughout the Skydoor: Framework Aluminium extrusion EPDM rubber gaskets Aluminium corner brackets Polyamide thermal break strips Polyester powder coated finish Silicone rubber seal Acrylic adhesive (corner joints) Toughened glass panes Low modulus silicone Aluminium spacer bar Foam tape Mechanisms and control Stainless steel fixings Printed circuit board Aluminium extruded mechanism base plate Rubber sealed deep groove ball bearings Acetal lead screw guide Copper wiring Mild steel linkage arms Electric motor (various) Stainless steel lead screw Limit switches (various) Aluminium oldham coupling Standard insulated spade terminals Ultramid nylon electrical connectors ABS electrical enclosure Bronze lead screw block inserts SPST rocker switch Natural rubber bump stop Acetal slide bracket

Page 9 of 10 Certification Following the certification of the X Vent and in accordance with the requirements of BS EN 12101-2:2003, this label will be affixed to each X Vent supplied by Glazing Vision. Date of Dispatch: Serial Number: 1720 X Vent A Natural Heat and Smoke Exhaust Ventilator Glazing Vision Ltd., Saw Mills Road, Diss, Norfolk IP22 4NX, UK 1720-CPD-0037 EN 12101-2:2003 Aa = max 0.6m²; WL 1500; SL 125; T (-15); Re 50; B300; A1 Temperature of thermal initiation device 72ºC

Page 10 of 10 Product Warranty A warranty document will be provided with the rooflight. If this is misplaced it can be found at www.glazingvision.co.uk/resources/warranties/.