K*, R* Ventilation grilles

Similar documents
Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Air distribution for clean rooms. Clever and flexible.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

Ceiling diffusers. Type DLQL

Compact. Efficient. TROX.

Ceiling swirl diffusers

Ceiling swirl diffusers

Dual certification! Air handling units for potentially explosive atmospheres

Fire dampers. For diverse applications

Decentralised ventilation

Decentralised Ventilation Systems

Filter Technology from A to Z. Filter units and filter elements from TROX

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

Compact. Efficient. TROX.

Decentralised ventilation units

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Chilled Ceiling Elements

Units for suspended ceilings

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Units for suspended cei lings

TEVHR. Heat Recovery Ventilator

Decentralised ventilation units

Units for suspended ceilings Type DID632

Problems Air and Water Distribution Systems

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

GB/en. Operating manual. Air handling unit. X-CUBE compact. Read the instructions prior to performing any task!

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Heat your whole home in just 10 minutes!

FRESHVENT. Select a product. Home/Freshvent

AIR HANDLING UNITS MANDÍK

Axial fans The right fan for every house

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

Danvent DV 190 and 240

photo by PFC Price Fan Column

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

The innovative air handling unit. By TROX.

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

COOLflow 4E PRODUCT RANGE

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

Caice Attenuator Selector - Specifier Edition

ECOVENT: IT S MORE THAN A VENT. It s a climate control mastermind

Application and Installation Guide (excluding Solar Air Collectors)

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE

Caution: The fans must not be used in bath or shower enclosures.

RHC & RHCE gas fired heating coils

GOLD RX, GOLD RX 12 GOLD RX,

Description of the air handling unit

Description of the air handling unit

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

COMMERCIAL LINE DUPLEX ROTO

Decentralised ventilation unit

Decentralised ventilation unit

Systemair product news - Fans NEWS

Viega innovations A pledge for the future: Connected in quality.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator School

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

FlowGrid for Axial and Centrifugal Fans

V3 Intelligent Damper Control and Monitoring System

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

PRESENTATION SUMMARY

Innovative solutions for air and climate technology. Air handling Climate ceilings Air distribution technology Fire safety products Chilled beams

Fresh air for offices. Innovative room air strategies create ideal working conditions

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

Active Chilled Beams

FIRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW. Fire Rated Products

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

ACCUBLOC high performance Heat Recovery

Installation and Maintenance

Quick set-up guide. [Simple plug and play system]

SECTION AIR OUTLETS AND INLETS

FlowGrid air-inlet grille for axial and centrifugal fans. Less noise more quality of life.

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Integrated Solution PARTNERS

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

DAIKIN Air Handling Unit Modular

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

EKK Anlagentechnik. Plastics and Environmental Technology. Update 01/2018. certified acc. to ISO 9001 ISO 14001

CONDOR. Supply air ceiling QUICK FACTS

CONTENTS. MANDÍK, a. s. Company Headquarters. SAFAN Press Brakes TRUMPF TC 5000 Die-Cutting Presses Powder Paint Shop

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Transcription:

Homepage > Products > Air Diffusers > Air grilles > K*, R* Ventilation grilles K*, R* Ventilation grilles ATTACHMENTS FOR TYPE TRS-K AND TYPE TRS-R VENTILATION GRILLES, MADE OF SHEET STEEL, FOR VOLUME FLOW RATE BALANCING Attachments with manually adjustable blades Volume flow rate balancing Hit and miss damper with airflow straighteners Skimming hit and miss damper with airflow straighteners

APPLICATION Application Attachments for ventilation grilles offer additional functions For volume flow rate balancing Damper units simplify the volume flow rate balancing required for commissioning, for supply air and extract air Ventilation grille need not be removed for adjustment DESCRIPTION Variants S: Hit and miss damper 5: Slanting special hit and miss damper Maintenance Maintenance-free as construction and materials are not subject to wear Inspection and cleaning to VDI 6022 TECHNICAL INFORMATION Function

FUNCTION Schematic illustration of -S 1 Hit and miss damper, blade for flow adjustment 2 Airflow straightener Attachments -AS, -S Variants, Dimensions and weight VARIANTS Any attachments are to be defined with the order code of the ventilation grille. -*S Application For volume flow rate balancing Damper units simplify the volume flow rate balancing required for commissioning, preferably for extract air Ventilation grille need not be removed for adjustment Parts and characteristics Hit and miss damper elements with airflow straighteners

Can be adjusted and set with screws -*5 Application For volume flow rate balancing Slanting hit and miss damper that ensures a uniform airflow through the grille face Damper units simplify the volume flow rate balancing required for commissioning, preferably for extract air Ventilation grille need not be removed for adjustment Parts and characteristics Hit and miss damper elements with airflow straighteners Can be adjusted and set with screws Attachments for ventilation grilles of Types TRS-K, TRS-R Type of ventilation grille Type of ventilation grille Attachment -*S -*5 Hit and miss damper Special hit and miss damper Installation into rectangular ducts TRS-K Installation into circular ducts TRS-R S

5 DIMENSIONS AND WEIGHT The weight table shows the available nominal sizes -*S

T T1 T2 Product type mm mm mm TRS-K 42 7 63 -*S Product type TRS-R Nominal height T T2 mm mm mm HN 75 42 70 125 42 74 TRS-R 225 42 86 -*5 Product type TRS-K L T1 T2 mm 225 7 87 325 7 99 TRS-K 425 7 112 525 7 124 TRS-K 625 7 136 825 7 160 TRS-K 1025 7 185 1225 7 210 -*5

Product type Product type L L H [mm] 75 125 225 T2 mm TRS-R 225 95 99 325 107 111 123 TRS-R 425 119 123 136 525 131 135 147 TRS-R 625 143 147 159 825 162 171 183 TRS-R 1025 191 195 207 1225 215 211 231 -S L Nominal length H Nominal height Attachments -AS, -S

-5 L Nominal length H Nominal height Commissioning COMMISSIONING Volume flow rate balancing When several ventilation grilles are installed on the same duct, it may be necessary to balance the volume flow rates. AG: Damper unit with opposed action blades, adjustable, secured with a locking screw AS: Damper unit with hit and miss damper, adjustable, secured with a locking screw Air pattern Adjustable blades: Set the air control blades individually or together and depending on the local conditions D, DG: Air control blades, fitted at 90 to the front blades, can be adapted to the local conditions Volume flow rate balancing -S Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2017-11-27 TROX GmbH

Homepage > Products > Air Diffusers > Air grilles > K*, R* Ventilation grilles Attachments -AS, -KS, -RS and Type ASW Volume flow rate balancing -5 Attachments -5 Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2017-11-27 TROX GmbH

Homepage > Products > Air Diffusers > Air grilles > K*, R* Ventilation grilles TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2017-11-27 TROX GmbH