MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

Similar documents
Model 76 Dehumidifier Control Installation Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 1750A/ 1770A Dehumidifier Installation Instructions

Safety and Installation Instructions Model 1700

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Installation, Safety & Maintenance Manual Model 1750A/1770A

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

Model 1820 Dehumidifier

Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)

Installation and Operation Manual

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Model 1870F Dehumidifier Installation and Operating Manual

DEALER PARTS LIST DEHUMIDIFIERS. Model 1830/1850/1850F/1850W 17A 17B 17C

Model 1850F Dehumidifier Installation and Operating Manual

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

Safety & Installation Instructions

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Model 8120 and 8126 Safety & Installation Instructions

INSTALLER S & OWNER S MANUAL

Safety & Installation Instructions

Safety & Installation Instructions

Safety & Installation Instructions

INSTALLER S & OWNER S MANUAL

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Dehumidifiers. Product Guide. Smaller. Quieter. Smarter.

INSTALLER S & OWNER S MANUAL

Safety & Installation Instructions

Desiccant Dehumidifier

Fresh Air Ventilation

Safety & Installation Instructions

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

INSTALLER S & OWNER S MANUAL

Humidifiers Dealer Parts List Model 400/400M Humidifiers

DEHUMIDIFIERS /2015 OWNER S MANUAL FOR HEALTHY CLIMATE DEHUMIDIFIER CONTROL MODEL Y6456

Humidifiers Dealer Parts List

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Safety & Installation Instructions

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Model 75 Dehumidifier Control Owner s Manual

Installation Instructions

Safety, Installation, and Operation Manual

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

Model 65 Humidifier Control Owner s Manual

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

INSTALLER S & OWNER S MANUAL

S1-CVD090T01 / S1-CVD135T01 Central Ventilating Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model 1730A Compact Dehumidifier Installation Instructions

Fresh Air Solutions Whole-Home Ventilation

Safety & Installation Instructions

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

INSTALLER S & OWNER S MANUAL

Installation, Operation and Maintenance Instructions

CommStat 4 Controller

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

HVAC for Raters & Inspectors

Ultra-Aire 150H Whole House Ventilating Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

AirCycler g2-k Installation & User s Guide

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

Quest Dry Quest Dry 105, 155, and 205

All Product Specifications

All Product Specifications

Daikin ENVi Thermostat installation overview

HEAT HEAT HEAT COOL COOL

HEX390 Heat Exchanger

INSTALLATION INSTRUCTIONS

DXM2 Digital Heat Pump Controller

HEAT COOL. Meets Commercial California Title 24

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

SAFETY AND INSTALLATION MANUAL MODEL 8100

LZP-2 ZONE CONTROL PANEL

Digital Precise Air Control - DPAC

EL-TSTAT-8820 Safety & Installation Instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Siemens Thermostats. RDY2000BN Thermostat

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

Steam Humidification Light Commercial Applications. Better technology means better business.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

OWNER S MANUAL Venstar Inc. 08/07

INSTALLATION, OPERATION & QUICK START GUIDE

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

CONTENTS. Installation Guide. VT7200 Series

Installation & Operation Instructions

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Instruction Guide: Thermostat Operation

Automatic Digital Humidifier Control

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Transcription:

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE Application Primary Zone to Dehumidify Secondary Zone to Dehumidify Control Type Application Sheet No. Single Zone Whole House or Basement N/A Internal 1 External 2 Remote Control (Single Zone) Crawlspace, Sealed Attic, Storage, Basement N/A Remote - Model 76 in the living space 3 Two Zone Whole house Basement Internal 4 External in Primary 5 Two Zone Basement Whole house Internal 4 External in Primary 5 Using the Ventilation Feature 6 The Application Quick Start Guide is to be used as a reference only. Installation is to be performed by qualified heating and air conditioning professionals in accordance with the Installation Manual provided with the dehumidifier.

Application Sheet 1 Single Zone Using Internal Control Parts Needed (additional parts may be required): Model 1830/1850/1870 Thermostat wire Duct fittings & hardware Grilles (if required) Drain Pan and Float Switch (if required) Main Return to Main Return - Recommended Main Return to Main Supply Figure 3 Wiring (shown without disable with AC feature being used) Dedicated Return to Main Supply or Return Figure 1 Dehumidifier Ducted to HVAC System The dehumidifier will automatically sample the air by turning on its blower (and the HVAC blower if this option has been wired see Figure 3), and measuring the relative humidity (RH) once every hour. Sampling will also occur when the RH setting is lowered using the UP or DOWN buttons on the control. During sampling, if the RH of the air is above the setting the dehumidifier, the compressor will turn on. The compressor, dehumidifier blower and HVAC system blower (if on) turns off when the RH of the air is 3% RH below the setting. Figure 2 Dehumidifier Ducted Directly

Application Sheet 2 Single Zone Using External Control Parts Needed (additional parts may be required): Model 1830/1850/1870 Thermostat wire Duct fittings & hardware Model 76, Model 8620 Grilles (if required) or Model 8910 control Drain Pan and Float Switch (if required) Main Return to Main Return - Recommended Main Return to Main Supply Figure 3 Wiring (shown without disable with AC feature being used) Dedicated Return to Main Supply or Return Figure 1 Dehumidifier Ducted to HVAC System Figure 2 Dehumidifier Ducted Directly External Control The external control (i.e. Aprilaire Model 76 Dehumidifier Control, Model 8620 Thermostat or Model 8910 Home Comfort Control) must have a normally open (NO all Aprilaire controls are normally open type) or normally closed (NC) dry contact output, and must be installed in the space that is going to be dehumidified. Select the type of control using the NO/NC dip switch on the dehumidifier control. When the external control calls for dehumidification, the dehumidifier blower the HVAC blower (if this option has been wired see Figure 3) turn on, then three seconds later the compressor turns on. All will turn off when the external control stops calling for dehumidification.

Application Sheet 3 Remote Control Using Model 76 Control Parts Needed (additional parts may be required): Model 1830/1850/1870 Model 76 Dehumidifier Control Thermostat wire Duct fittings & hardware Grilles (if required) Drain pan and float switch (if required) MODEL 76 REMOTE CONTROL FLOAT DH DH SWITCH NC NO A B C/- R/+ DH DH Figure 1 Dehumidifier Ducted Directly Set Up the Dehumidifier for Remote Control After wiring the Model 76 to the dehumidifier as shown, use the power switch located on the outlet panel of the dehumidifier to power up the dehumidifier. The dehumidifier control should display OFF. HVAC EQUIP Gh Rf Cf Gs W Y Figure 2 Wiring the Control DEHUMIDIFIER CONTROL BOARD 1. Enter the Installer Set-Up menu by pressing and holding the Mode button on the dehumidifier control for 3 seconds; REMOTE DISABLED will appear on the display. 2. Press the Up or Down button to select REMOTE ENABLED. 3. Press the Mode button again to complete set up ( DONE will appear on the display). The Model 76 Dehumidifier Control can be installed in any convenient location within the living space while the dehumidifier is installed in the space that is going to be dehumidified such as a crawl space, attic or basement. The relative humidity (RH) displayed on the Model 76 is the RH in the space where the dehumidifier is located the dehumidifier communicates this to the Model 76. Changes to the dew point setting (1 less dry, 7 more dry) are made at the Model 76 and communicated to the dehumidifier. The dehumidifier can be turned on and off using the ON/OFF buttons of the Model 76. Once every hour the dehumidifier will turn on its blower and sample the air in the zone to be dehumidified (sampling will also occur whenever the dew point setting is raised). If the dew point of the air is higher than the setting on the control, the dehumidifier compressor will turn on. When the dew point of the air is below the setting on the Model 76 Control, the dehumidifier will turn off. When the Model 76 Control is wired to the dehumidifier in this application and after completing the set up (see Set Up the Dehumidifier for Remote Control above), REMOTE will appear on the display of the dehumidifier control.

Application Sheet 4 Two Zone using Internal Control Parts Needed (additional parts may be required): Model 1830/1850/1870 Thermostat wire Duct fittings & hardware Drain pan and float switch (if required) Grilles 4522 Damper Kit (includes: 2 8 dia N.O. dampers, 2 8 dia N.C. dampers and one 40VA, 24VAC plug-in transformer) OPEN TO/FROM PRIMARY ZONE TO BE DEHUMIDIFIED TO/FROM SECONDARY ZONE TO BE DEHUMIDIFIED OPEN Figure 1 Duct/Damper Layout with Whole House as Primary Zone OPEN TO/FROM SECONDARY ZONE TO BE DEHUMIDIFIED TO/FROM PRIMARY ZONE TO BE DEHUMIDIFIED OPEN Figure 2 Duct/Damper Layout with Basement as Primary Zone N.C. S N.O. S R C G W Y THERMOSTAT EXISTING WIRE NEW WIRE R C G W Y HVAC EQUIPMENT FLOAT DH DH SWITCH 20 VA (MIN.) TRANSFORMER HVAC EQUIP Gh Rf Cf Gs W Y Figure 3 Wiring 120 VAC 24 VAC DEHUMIDIFIER CONTROL BOARD NC NO Adjust the relative humidity (RH) setting on the dehumidifier control; this will be the setting for both the Primary and Secondary Zone. Once an hour, the dehumidifier will sample the air in the Primary Zone. If there is no need for dehumidification in the Primary Zone the dehumidifier will then sample the air in the Secondary Zone. When sampling in the Primary Zone the dehumidifier will energize the dampers and then turn on its blower (and the HVAC System blower if wired as shown in Figure 3), to measure the RH of the air. If the RH of the air is above the setting, the compressor will turn on. If the Primary Zone does not need dehumidification, the dampers are de-energized and the HVAC System Blower (if on) is turned off while the dehumidifier blower continues to run to sample the air in the Secondary Zone. If the RH of the air in the Secondary Zone is above the setting, the compressor will turn on. Set Up the Dehumidifier for Zoning 1. With OFF showing on the control, press the Mode button for 3 seconds to enter the Installer Set Up menu 2. Press the Mode button until ZONE DISABLED appears. 3. Press the Up or Down button to change to ZONE ENABLED. 4. Press the Mode button repeatedly until DONE shows on the display.

Application Sheet 5 Two Zone with External Control in Primary Zone Parts Needed (additional parts may be required): Model 1830/1850/1870 Model 76, Model 8620 or Model 8910 control Thermostat wire Duct fittings & hardware Drain pan and float switch (if required) Grilles 4522 Damper Kit (includes: 2 8 dia N.O. dampers, 2 8 dia N.C. dampers and one 40VA, 24VAC plug-in transformer) OPEN TO/FROM PRIMARY ZONE TO BE DEHUMIDIFIED TO/FROM SECONDARY ZONE TO BE DEHUMIDIFIED OPEN Figure 1 Duct/Damper Layout with Whole House as Primary Zone OPEN TO/FROM SECONDARY ZONE TO BE DEHUMIDIFIED TO/FROM PRIMARY ZONE TO BE DEHUMIDIFIED OPEN Figure 2 Duct/Damper Layout with Basement as Primary Zone Figure 3 Wiring REMOTE + - A B ODT SENSOR S VENT DEH The external control (i.e. Model 76 Control or Model 8910 Home Comfort Control) provides on-demand control of the dehumidifier for the Primary Zone. When the Primary Zone calls for dehumidification, the dehumidifier energizes the dampers, and turns on its blower and compressor. The dehumidifier will also turn on the HVAC System Blower if wired as shown in Figure 3). The Primary Zone demand will override an existing Secondary Zone demand. The Secondary Zone is controlled by the relative humidity (RH) setting at the dehumidifier control. Once an hour, or immediately after dehumidifying the primary zone, the dehumidifier will sample the air in the Secondary Zone. When sampling, the dampers are not energized while the dehumidifier blower runs and the RH is measured If the RH is above the setting on the control, the compressor will turn on and the Secondary Zone will be dehumidified. Set Up the Dehumidifier for Zoning and External Control 1. Press the Mode button for 3 seconds to enter the Installer Set Up menu 2. Press the Mode button until ZONE DISABLED appears. 3. Press the Up or Down button to change to ZONE ENABLED. 4. Press the Mode button again to show EXTERNAL DISABLED 5. Press the Up or Down button to change to EXTERNAL ENABLED 6. Press the Mode button repeatedly until DONE shows on the display.

Application Sheet 6 Using the Ventilation Feature of the Dehumidifier Parts needed for ventilation: Model 6506 damper Model 8052 Outdoor Temperature Sensor (optional) Model 4010 10VA Transformer 6 Insulated Duct, fittings and hardware Intake Hood Thermostat wire Figure 1 Ventilation Duct Location Figure 2 Ventilation Wiring Install a ventilation duct with a normally closed Model 6506 damper to the return duct of the HVAC system (see Figure 1) and wire the dehumidifier to the HVAC system as shown in Figure 2. The outdoor temperature (ODT) sensor is used to limit ventilation if the outdoor temperature gets too hot or too cold (see Set Up the Dehumidifier for Ventilation below), if temperature limits are not needed, the ODT sensor does not have to be installed. Follow the set up instructions below and set the number of minutes per hour that ventilation will be needed (refer to the Installation Manual for details on determining how much ventilation is needed). Whenever the heating or cooling turns on, or when the dehumidifier turns on, the dehumidifier will open the damper and bring in fresh outdoor air. If the equipment doesn t run for the set number of minutes, the dehumidifier will turn on HVAC fan at the end of the hour to ensure ventilation needs are met. Set Up the Dehumidifier for Ventilation 1. With OFF showing on the control, press the Mode button for 3 seconds to enter the Installer Set Up menu 2. Press the Mode button until VENT DISABLED appears. 3. Press the Up or Down button to change to VENT ENABLED. 4. Press the Mode button and VENT TIMED will be displayed. Press the Up or Down button to toggle between: TIMED: no temperature limits AUTO B: Ventilation not allowed if ODT > 100 F or ODT < 0 F; allowed only when heating if 0 F < ODT < 20. AUTO C: Ventilation not allowed if ODT > 100 F or ODT < 0 F AUTO D: Ventilation not allowed if ODT > 90 F; allowed only when heating if 0 F < ODT < 40 F 5. Press the Mode button, the use the Up and Down buttons to set the Vent Time (minutes/hour). 6. Press Mode repeatedly until DONE appears on the display. Using the Dehumidifier to Pre-Condition the Ventilation Air Figure 3 Dehumidify Ventilation Air ODT SENSOR MODEL 6506 The dehumidifier can be used to remove moisture from the ventilation air before it is delivered to the home. Install the ventilation duct to the dehumidifier inlet duct as shown in Figure 3. The control on the dehumidifier must be used for the Primary Zone (i.e. an external control cannot be used) in this installation. If the RH of the incoming air is above the setting on the control the air will be dehumidified.

P.O. Box 1467 Madison, WI 53701-1467 Phone: 800/334-6011 Fax: 608/257-4357 www.aprilairepartners.com 10010431 Printed in U.S.A B2206146A 2013 Aprilaire A division of Research Products Corp.