GMH 285 / GMH 285-BNC

Similar documents
Operating Manual Hand-held Measuring Device GMH 3690 GL. for Gaseous Oxygen and Temperature with Alarm Function

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Four-stage controller. Order number

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Visit us at

OILTESTER - Deep-frying Oil Tester. Instruction manual

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Operating Manual UV Monitor UVT 18

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Specifications Minimum Typical Maximum Unit

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

SCHMIDT LED Measured Value Display MD Instructions for Use

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

eed quality electronic design USER s MANUAL

OILTESTER Deep-frying Oil Tester. Instruction manual

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Software Version 2.01 LEVEL MONITOR MODEL 220

R1000 / R1040 / R1080

Visit us at testo 835 Infrared and contact thermometer

Dixell Installing and Operating Instructions release 7.0

THERMAX Efficiency Monitor

Follett Performance Plus

Contamination Meter Users Manual

Digital 7 Square Plate Magnetic Stirrer

testo Leakage detector for gas Instruction manual

EasyTronic III MANUAL SERVICE

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Model: RT310. Installation Manual

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

testo 270 Deep-frying Oil Tester

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Service: to SLK Laboratory Hot Plates glass made of ideas

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

Installation and Operating Manual

testo 550 Digital manifold

Constant climate chambers

Focus 4010\ Focus 4010 HT porcelain firing furnace

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Electronic Temperature Controller 70304,

Portable Gas Detector Instruction Manual

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Model: RT310RF. Installation Manual

ELMTEC. Kattreppeln Königslutter / /

1 4 DIN Dissolved Oxygen Controller

Series Temperature Controller Instruction Sheet

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Constant climate chamber with humidity

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

ZED UV Monitor PRO11DPI-I

Vacuum Controller with Control Unit VC 900

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Constant climate chambers

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

XWA11V. Walk-In Temp / Door /Alarm / Light Module

IMR EX610. Portable Gas Detector. Operation Manual

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

ECL Comfort 110, application 116

Constant climate chamber with ICH-compliant illumination

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

EL-USB-1-LCD Temperature Data Logger with LCD

TDF 15 MICROPROCESSOR-BASED DIGITAL ELECTRONIC THERMOCONTROLLER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

User manual. Humimeter AW3 Meter

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Dry Bath Heating Systems

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Refrigerated air dryers

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Laboratory Refrigerator/Deep Freezer TC 802

HTG79 Operating Instructions

data logger DL200H DL200D DL200L

Transcription:

GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr. DE 93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 2 of 8 Index 1 DESIGNATED USE...2 2 GENERAL NOTE...2 3 SAFETY REQUIREMENTS...3 4 DISPLAY AND CONTROL ELEMENTS...3 4.1 DISPLAY ELEMENTS...3 4.2 CONTROL ELEMENTS...3 4.3 CONNECTIONS...3 4.4 POP-UP CLIP...4 5 START OF OPERATION...4 6 SOME BASICS OF PT 1000 PRECISION TEMPERATURE MEASUREMENT...5 7 CONFIGURATION OF THE DEVICE...6 8 ADJUSTMENT...7 9 ERROR AND SYSTEM MESSAGES...7 10 ACCURACY INSPECTION: ADJUSTMENT /UPDATE SERVICE...7 11 DISPOSAL NOTES...8 12 TECHNICAL DATA...8 1 Designated Use The device is measuring temperature in C or F. A suitable Pt1000 temperature probe has to be connected for operation. The safety requirements (see below) have to be observed. The device must be used only according to its intended purpose and under suitable conditions. Use the device carefully and according to its technical data (do not throw it, strike it, ). 2 General Note Read this document carefully and get used to the operation of the device before you use it. Keep this document within reach for consulting in case of doubt. If the device is stored at temperatures above 50 C the battery has to be removed from the device. NOTE: We recommend taking out battery if device is not used for a longer period of time. Risk of leakage!

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 3 of 8 3 Safety Requirements This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device. 1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under "Specification". If the device is transported from a cold to a warm environment condensation may cause in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up. 2. WARNING: If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if: - there is visible damage to the device - the device is not working as specified - the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance. 3. WARNING: Do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage. 4 Display and Control Elements 4.1 Display elements main display standard arrow up arrow down HLD BAT Display of the current temperature Display of maximum temperature Display of minimum temperature Display of Hold-value BAT-Warning: pls. change battery 4.2 Control elements key 1: key 2: key 3: on/off key, press shortly: reactivate Backlight Mode press shortly: minimum value press again: maximum value press again: return to standard display press for 2 sec.: reset minimum and maximum values Hold: press shortly: The current value is frozen (hold-function), HLD is displayed 4.3 Connections interface: connection for galv. Isolated interface adapter (accessory: GRS 3100, GRS3105 or USB3100) BNC-socket (GMH 285-BNC) or 3.5mm audio socket (GMH 285): Connection for Pt1000 temperature probe

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 4 of 8 4.4 Pop-up clip Handling: Pull at label open in order to swing open the pop-up clip. Pull at label open again to swing open the pop-up clip further. Pop-up clip closed Pop-up clip at position 90 Pop-up clip at position 180 Function: The device with a closed pop-up clip can be plainly laid onto a table or attached to a belt, etc. The device with pop-up clip at position 90 can be set up on a table, etc. The device with pop-up clip at position 180 can be suspended from a screw or the magnetic holder GMH 1300. Device attached to a belt Device set up on a table Device suspended from magnetic holder GMH 1300 5 Start of Operation Switch the device on with the key. After segment test the device displays some information to its configuration:![!f selected display unit (p.r.t. chapter 8) 0FFS if there is a offset adjustment (p.r.t. chapter 8) S[AL if there is a slope adjustment (p.r.t. chapter 8) P. if the automatic-off-function is activated (p.r.t chapter 6) The device starts measurement afterwards.

Fehler [ C] H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 5 of 8 6 Some Basics Of Pt 1000 Precision Temperature Measurement Probe Precision/Device Precision The device is very precise (please refer to technical data). To be able to use this high precision, the connected temperature probe has to be as precise as possible, too. The following precision classes are available as a standard at reasonable prices (Platinum resistor thermometers according to EN60751): Class Error ranges B ± (0,3 + 0,005 Temperature ) A ± (0,15 + 0,002 Temperature ) AA (=1/3 DIN B) ± (0,1 + 0,0017 Temperature ) Fehler Gerät und Temperaturfühler 1,2 B 1 0,8 1/3 B 0,6 0,4 0,2 0-50 -30-10 10 30 50 70 90 110 130 150 Error over range 50...150 C For applications demanding higher precision than given by this classes we suggest to adjust the device to the used probe or to get a calibration certificate for the device combined with the probe. Attention: if an adjusted or calibrated probe is replaced, also the adjustment or calibration certificate has to be renewed to maintain the referring overall precision! Be careful when buying third party temperature probes: Besides the standard EN60751 there are some other obsolete or unusual standards on the market. If such a probe has to be connected, the user sensor curve (have a look to the referring chapter) can be used to adjust the instrument! 2-Wire-Measurement The GMH 285 uses 2 wire measurement, this means, cable and contact resistances may affect measurement precision. For usual cables up to some meters the cable resistance is negligible. Keep contact clean and free from oxidation to avoid contact effects. Allowable temperature Range Of Probes Pt100 Sensors are defined over a wide temperature range. Depending on probe materials and sort of sensor (e.g. hybrid sensors, wire wound resistors...) the allowable temperature ranges have to be considered. Exceeding the ranges at least causes a wrong measurement, it may even damage the probe permanently! Often it also has to be considered, that the temperature range is just valid for the probe tube, (plastic-) handles can t stand the same high temperatures. Therefore the tube length should be selected long enough, that temperature keeps low at the handle. Self Heating The measurement current of the instrument is just 0.3mA. Because of this comparably low current practically now self heating effect has to be considered, even at air with low movement the self heating is <= 0.01 C. Cooling by Evaporation When measuring air temperature the probe has to be dry. Otherwise the cooling due to the evaporation causes too low measurement. Heat loss caused by probe construction: Especially when measuring temperatures which deviate very much from the ambient temperature, measurement errors often occur if the heat loss caused by the probe is not considered. When measuring fluids therefore the probe should be emerged sufficiently deep and be stirred continuously. When measuring gases the probe should also emerge as deep as possible in the gas to be measured (e.g. when measuring in channel/pipes) and the gas should flow around the probe at sufficient flow. Measuring Surface Temperature If temperature of the surface of an object has to be measured, one should pay attention especially when measuring hot (or very cold) surfaces, that the ambient air cools (or heats) the surface. Additionally the object will be cooled (or heated) by the probe or the probe can have a better heat flow to the ambient temperature as to the objects surface. Therefore specially designed surface probes should be used. The measurement precision depends mainly on he construction of the probe and of the physics of the surface itself. If selecting a probe try to choose one with low mass and heat flow from sensor to handle. Thermally conductive paste can increase the precision in some cases. T [ C]

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 6 of 8 7 Configuration of the Device Follow these instructions to configure the functions of the device: Switch device off. Switch the device on and press parameter P. Set parameter with = up or = down. Jump to the next parameter by pressing. Parameter Value Information Keys Key P. UN,T AL AL.LO AL.K, ADR. L,TE AUTO HLD INIT during the segment test, until the display shows the first Auto Power-Off (turn-off delay) factory setting: 20 min. Auto Power-Off (turn-off delay) in minutes. If no key is pressed for the time 1 120 adjusted here, the device is automatically switched off (adjustable 1 120 min) Auto power-off is deactivated (continuous operation) Display unit factory setting: C C Measuring value displayed in Celsius F Measuring value displayed in Fahrenheit Alarm setting factory setting: off ON NO.SO no alarm monitoring alarm monitoring via display, interface and sound (Buzzer) alarm monitoring via display, interface, no sound (Buzzer) Alarm setting: Min factory setting: -5.0 C Min alarm limit, highest possible value: Max Alarm limit -200.0 AL.K, Alarm setting: Max factory setting: -5.0 C Max alarm limit, lowest possible value: Min Alarm limit AL.LO 400.0 Base Address factory setting: 01 Base address for serial interface communication 0 1 9 1 Backlight -auto-off factory setting: 10 sec. No backlight 5 120 ON Backlight turns automatically off after 5 120 s (battery saving) Backlight always on as long as device is switched on Auto Hold-Function factory setting:: off Auto Hold activated: automatic holding of the measured value, as soon as it is ON stabilized. Auto Hold deactivated: Value is frozen on keypress (hold) Restore factory settings Parameters are not changed to factory settings. NO YES ATTENTION: All parameter are changed to factory settings. Press NOTE: again to store changed settings, the device restarts (segment test). If there is no key pressed within the menu mode within 2 minutes, the configuration will be cancelled, the entered settings are lost!

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 7 of 8 8 Adjustment The instrument can be adjusted, assuming that: Reliable references are available, such as icewater regulated precision water baths or similar. : Displayed value C =(measured value C - S) * (1 + slope correction / 100 ) Displayed value F =(measured value F - 32 F - S) * (1 + slope correction / 100 ) Follow these instructions to adjust the device: Switch the device on. Press and together until the first parameter 0FFS is displayed. Set parameter with = up or = down Jump to the next parameter by pressing. Parameter Value Information Keys Key Press NOTE: SET correction factory setting: off = 0.0 C No offset correction -5.0 5.0 C or Value of offset correction -9.0 9.0 F Slope correction factory setting: off= 0% No slope correction -5.00 5.00 Value of slope correction in % again to store changed settings, the device restarts (segment test). If there is no key pressed within the menu mode within 2 minutes, the configuration will be cancelled, the entered settings are lost! 9 Error and System Messages ---- No temperature probe connected ERR. 1 ERR. 2 ERR. 7 Or at GMH 285 BNC: cable/sensor broken Or at GMH 285: cable/sensor shorted Value exceeding measuring range, value too high or cable/sensor broken Value exceeding measuring range, value too low or cable/sensor shorted System error the device has detected a system error (device defective or not within working temperature) The blinking bat display indicates low battery voltage, device will continue to work for a short time. The battery is consumed and has to be changed. Measurements are no longer possible. 10 Accuracy Inspection: Adjustment /Update Service You can send the device to the manufacture or retailer for adjustment and inspection. Moreover the manufacturer can do the latest software update. This ensures that future improvements are provided to owners of older devices in a cost-saving way. You can display the current software version if you do not release the on/off button after you switched the device on, but hold it for more than 5 seconds. (i.e. r. 1.0 )

H69.0.01.6C-02 Operating Manual GMH 285 / GMH 285-BNC page 8 of 8 11 Disposal Notes Dispense exhausted batteries at destined gathering places. This device must not be disposed as residual waste To dispose this device, please send it directly to us (adequately stamped). We will dispose it appropriately and environmentally friendly. 12 Technical Data Measurement Range Resolution Accuracy Frequency Display Hold function Min/Max memory Alarm Adjustment Resistive temperature measuring Pt1000 GMH 285-BNC: BNC socket GMH 285: 3.5mm audio socket -200,0 C to 400,0 C / -200,0 F to 752,0 F 0.1 C / 0.1 F -100.0 200.0 C: +/-0.1 C +/-1 digits else: +/-0,1 % of measured value +/-1 digits 2 measurements per second 4 ½ digits LCD (13 mm) with additional segments Press button to freeze current value. or Auto hold: a stable value will automatically be captured with HLD Highest and lowest values after switching on are memorized Freely configurable min/max alarm via buzzer, display and interface Menue: offset/scale, factory settings are recoverable Working temperature -25 to 50 C Storage temperature -25 to 70 C Power supply 9V battery, type: IEC 6F22 (included in scope of supply), external d.c. connector Power consumption < 0.20 ma (battery life time: more than 1500 hours for alkaline battery) Backlight: <5mA, will be automatically switched of at BAT -warning battery state display bat displayed in main display, if battery used up, warning symbol: BAT for weak battery Auto off-function Device will be automatically switched off if not operated for longer time (adjustable from 1..120 min) Housing impact-resistant ABS plastic housing Protection class Front side IP65 Dimensions without BNC connector 142 x 71 x 26 mm (L x B x H) BNC connector at the devices front end: approx. 13 mm long Weight Approx. 170 g incl. battery EMC The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG), additional error: < 1% FS