SECTION BRICK PAVERS. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Similar documents
Tile Tech Warnings. Paving America one step at a time! MANUFACTURER OF DETECTABLE WARNING PAVERS AND TILES

ARBOR SERIES WOOD WALLCOVERINGS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

BorAL. PAvErS Build something great. commercial pavers BUILD A TRADITION IN YOUR COMMUNITY WITH BORAL PAVERS.

Glen-Gery Paving Brıck

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

WALLCOVERINGS WALLCOVERINGS

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION DOMESTIC WATER HEATERS

Artistic Paver Mfg. Phone: (305) Fax (305)

Ballast Paver Design & Installation Guide

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Artistic Paver Mfg. Phone: (305) Fax (305)

Chapter 19.5 LANDSCAPING REQUIREMENTS

ARCHITECTURAL PAVING STONE PRODUCT CATALOG

SECTION GYPSUM PLASTER

pavers. effortless style Pavers Tasmania

317)

c. Oko-Tex (European environmental health standard)

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

PART 1 GENERAL 1.01 SUMMARY

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

Artistic Paver Mfg. Phone: (305) Fax (305)

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

GREEN COLLECTION E C O - F R I E N D LY P E R M E A B L E P A V E R S T R E M R O N. C O M

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SECTION FIRE-RATED GLASS AND FRAME

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

BuildingProductsCorp.com

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

Winston-Salem State University Campus Master Plan 2016 Update

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SECTION SECURITY TESTING AND COMMISSIONING

Lakeshore Blend. is timeless..

Permeable Paving. Sustainable Control Of Urban Storm Water Pollution. The volume of storm water being diverted to

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SECTION PLANTING SOIL for SOIL CELLS. This specification defines material and performance requirements for soils which are to be used

Installation Manual May 9/14 No revision

PART 1 GENERAL 1.01 SUMMARY

Artistic Paver Mfg.

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Building & Site Design Standards Application

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

PART 1 GENERAL 1.01 SUMMARY

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

Write Walls Dry Erase Specification Data (Section 09720)

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Australian/New Zealand Standard

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

City of New Bedford STAFF REPORT

815 NE 172 nd Avenue Vancouver, WA Installation Manual

security resources international PART I: GENERAL eguardian Series 1.01 SUMMARY 1.02 REFERENCES 1.03 SUBMITTALS 1.04 QUALITY ASSURANCE

SECTION Overhead Coiling Doors

Public Notice. REQUEST FOR QUOTES Town of Woodstock Downtown Parking Lot Improvement Project Landscape Material. June 22, ADDENDUM NO.

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

SECTION ELECTRIC WATER HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

MacroAir AirElite HVLS Fans

DOWNTOWN TRANSCONA URBAN DESIGN GUIDELINES

PART 1 GENERAL 1.01 SUMMARY

... just better. Architecturally... Bold & Beautiful

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

NATURAL GAS PIPING

Permeable Interlocking Pavers

Hardscape Products for Outdoor Living.

ATTACHMENT L. Provision C.3.c.i.(1)(b)(vi) Specification of soils for Biotreatment or Bioretention Facilities

Specification of Soils for Biotreatment or Bioretention Facilities

Highway Oriented Commercial Development Criteria

Product Guide Specification

Technical Bullet Series on Clay Brick Pavers

ATTACHMENT A BIORETENTION SOIL SPECIFICATION

SECTION SOIL PREPARATION

SECTION ROTARY-SCREW WATER CHILLERS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

3.13. Development Guidelines

Paving Systems Using Clay Pavers

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

SECTION 02230BP AGGREGATE BASE

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Hardscape Products for Outdoor Living

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

EXAMPLE SPECIFICATION ONLY

Office Fax Las Vegas Paver Mfg LLC ver 01_30_2019

1.3 REFERENCE STANDARDS

DIVISION 32 EXTERIOR IMPROVEMENTS LANDSCAPING

AS AS Australian Standard. Soils for landscaping and garden use. This is a free 7 page sample. Access the full version online.

National Reach. Local Service.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Transcription:

SECTION 32 14 00 BRICK PAVERS Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2013-2015 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Pedestrian/light vehicular pavers. B. Heavy vehicular pavers. C. Relieved edge pavers. D. Relieved edge and lugged pavers. E. Danish hand mould pavers. F. Paver step treads. G. Permeable pavers. 1.2 RELATED SECTIONS A. Section 32 13 16.23 - Stamped Concrete Paving. B. Section 32 10 00 - Bases, Ballasts, and Paving. C. Section 09 63 40 - Stone Flooring. 1.3 REFERENCES A. ASTM International, Inc. (ASTM): 1. ASTM C 902 - Standard Specification for Pedestrian and Light Traffic Paving Brick. 2. ASTM C 1272 - Standard Specification for Heavy Vehicular Paving Brick. 1.4 SUBMITTALS A. Submit under provisions of Section 01 30 00 - Administrative Requirements. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 32 14 00-1

2. Storage and handling requirements and recommendations. 3. Cleaning methods. C. Verification Samples: For each product and finish specified, two full-size samples representing actual products, colors and textures. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten years experience. B. Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of five years demonstrated experience in installing products of the same type and scope as specified. C. Mock-Up: Provide a completely assembled, typical wall areas installed with related accessories, in composite configurations designed to fulfill the performance criteria, and representative of the design as shown on the Drawings. 1. Locate mock-up in location as directed by the Architect. 2. Do not proceed with remaining work until workmanship is approved by Architect. 3. Mock-up area may become part of finished work. 4. Mock-up area may not become part of finished work. 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards. B. Store materials in manufacturer's original sealed, labeled packaging until ready for installation and in accordance with manufacturer's instructions. Protect from damage. 1.7 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. 1.8 WARRANTY A. Manufacturer's Standard Material Warranty: At project closeout, provide to Owner or Owners Representative an executed copy of the manufacturer's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Endicott Clay Products Co., which is located at: 57120 707th Rd.; Endicott, NE 68350; Tel: 402-729-3315; Fax: 402-729-5804; Email:request info (endicott@endicott.com); Web:www.endicott.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements. 2.2 PEDESTRIAN/LIGHT VEHICULAR PAVERS 32 14 00-2

A. Pedestrian/Light Vehicular Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface 1. Actual Product Size: 4 x 8 x 1-1/4 inches (102 x 203 x 32 mm). 2. Actual Product Size: 4 x 8 x 2-1/4 inches (102 x 203 x 57 mm). 3. Actual Product Size: 3-5/8 x 7-5/8 x 1-1/4 inches (102 x 203 x 32 mm). 4. Actual Product Size: 3-5/8 x 7-5/8 x 2-1/4 inches (102 x 203 x 57 mm). 5. Compliance: ASTM C 902, Class SX, Type 1. 6. Compliance: ASTM C 1272, Type R, application PS. 7. Compliance: ASTM C 1272, Type R, application PX. 8. Compliance: ASTM C 1272, Type F, application PS. 9. Compliance: ASTM C 1272, Type F, application PX. 10. Color: Rose Blend. 11. Color: Red Blend. 12. Color: Burgundy Blend. 13. Color: Bordeaux Blend. 14. Color: Copper Canyon. 15. Color: Coppertone. 16. Color: Medium Ironspot No. 77. 17. Color: Medium Ironspot No. 46. 18. Color: Dark Ironspot. 19. Color: Manganese Ironspot. 20. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf; including perimeter 21. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf; including perimeter 22. Pattern: Running Bond Pattern 10 ' T' spacers/sf; including perimeter 23. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf; including perimeter B. Pedestrian/Light Vehicular Pavers: Nominal 8 inch x 8 inch brick pavers with wirecut surface 1. Actual Product Size: 8 x 8 x 2-1/4 inches (203 x 203 x 57 mm). 2. Actual Product Size: 7-5/8 x 7-5/8 x 2-1/4 inches (194 x 194 x 57 mm). 3. Actual Product Size: 7-5/8 x 7-5/8 x 1-1/4 inches (194 x 194 x 32 mm). a. Surface Texture: Finished on five sides, one 8 x 8 inch face unfinished. 4. Compliance: ASTM C 902, Class SX, Type 1. 5. Compliance: ASTM C 1272, Type R, application PS. 6. Compliance: ASTM C 1272, Type R, application PX. 7. Compliance: ASTM C 1272, Type F, application PS. 8. Compliance: ASTM C 1272, Type F, application PX. 9. Color: Rose Blend. 10. Color: Red Blend. 11. Color: Burgundy Blend. 12. Color: Bordeaux Blend. 13. Color: Copper Canyon. 14. Color: Coppertone. 15. Color: Medium Ironspot No. 77. 16. Color: Medium Ironspot No. 46. 17. Color: Dark Ironspot. 18. Color: Manganese Ironspot. 19. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf; including perimeter 20. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf; including perimeter 21. Pattern: Running Bond Pattern 10 ' T' spacers/sf; including perimeter 22. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf; including 32 14 00-3

perimeter C. Pedestrian/Light Vehicular Pavers: Nominal 4 inch x 12 inch brick pavers with wirecut surface 1. Actual Product Size: 4 x 12 x 2-1/4 inches (102 x 305 x 57 mm). 2. Actual Product Size: 3-5/8 x 11-5/8 x 2-1/4 inches (92 x 295 x 57 mm). 3. Compliance: ASTM C 902, Class SX, Type 1. 4. Compliance: ASTM C 1272, Type R, application PS. 5. Compliance: ASTM C 1272, Type R, application PX. 6. Compliance: ASTM C 1272, Type F, application PS. 7. Compliance: ASTM C 1272, Type F, application PX. 8. Color: Rose Blend. 9. Color: Red Blend. 10. Color: Burgundy Blend. 11. Color: Bordeaux Blend. 12. Color: Copper Canyon. 13. Color: Coppertone. 14. Color: Medium Ironspot No. 77. 15. Color: Medium Ironspot No. 46. 16. Color: Dark Ironspot. 17. Color: Manganese Ironspot. 18. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf; including perimeter 19. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf; including perimeter 20. Pattern: Running Bond Pattern 10 ' T' spacers/sf; including perimeter 21. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf; including perimeter 2.3 HEAVY VEHICULAR PAVERS A. Heavy Vehicular Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface texture as manufactured by Endicott Clay Products Co. 1. Actual Product Size: 4 x 8 x 2-5/8 inches (102 x 203 x 67 mm). 2. Compliance: ASTM C 902, Class SX, Type 1. 3. Compliance: ASTM C 1272, Type R, application PS. 4. Compliance: ASTM C 1272, Type R, application PX. 5. Compliance: ASTM C 1272, Type F, application PS. 6. Compliance: ASTM C 1272, Type F, application PX. 7. Color: Rose Blend. 8. Color: Red Blend. 9. Color: Burgundy Blend. 10. Color: Bordeaux Blend. 11. Color: Copper Canyon. 12. Color: Coppertone. 13. Color: Medium Ironspot No. 77. 14. Color: Medium Ironspot No. 46. 15. Color: Dark Ironspot. 16. Color: Manganese Ironspot. 17. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf. 18. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf. 19. Pattern: Running Bond Pattern 10 ' T' spacers/sf. 20. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf. 2.4 RELIEVED EDGE PAVERS A. Relieved Edge Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface texture as 32 14 00-4

manufactured by Endicott Clay Products Co. 1. Actual Product Size: 4 x 8 x 2-1/4 inches (102 x 203 x 57 mm). 2. Actual Product Size: 4 x 8 x 2-5/8 inches (102 x 203 x 67 mm). 3. Compliance: ASTM C 902, Class SX, Type 1. 4. Compliance: ASTM C 1272, Type R, application PS. 5. Compliance: ASTM C 1272, Type R, application PX. 6. Compliance: ASTM C 1272, Type F, application PS. 7. Compliance: ASTM C 1272, Type F, application PX. 8. Relieved Edges: 1/8 inch x 1/8 inch. 9. Color: Rose Blend. 10. Color: Red Blend. 11. Color: Burgundy Blend. 12. Color: Bordeaux Blend. 13. Color: Copper Canyon. 14. Color: Coppertone. 15. Color: Medium Ironspot No. 77. 16. Color: Medium Ironspot No. 46. 17. Color: Dark Ironspot. 18. Color: Manganese Ironspot. 19. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf; including perimeter 20. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf; including perimeter 21. Pattern: Running Bond Pattern 10 ' T' spacers/sf; including perimeter 22. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf; including perimeter 2.5 RELIEVED EDGE AND LUGGED PAVERS A. Relieved Edge/Lugged Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface 1. Actual Product Size: 4 x 8 x 2-1/4 inches (102 x 203 x 57 mm). a. Lugs: 1/8 inch (3 mm). 2. Actual Product Size: 4 x 8 x 2-1/4 inches (102 x 203 x 57 mm). a. Lugs: 1/4 inch (6 mm). 3. Actual Product Size: 4 x 8 x 2-5/8 inches (102 x 203 x 67 mm). a. Lugs: 1/8 inch (3 mm). 4. Actual Product Size: 4 x 8 x 2-5/8 inches (102 x 203 x 67 mm). a. Lugs: 1/4 inch (6 mm). 5. Compliance: ASTM C 902, Class SX, Type 1. 6. Compliance: ASTM C 1272, Type R, application PS. 7. Compliance: ASTM C 1272, Type R, application PX. 8. Compliance: ASTM C 1272, Type F, application PS. 9. Compliance: ASTM C 1272, Type F, application PX. 10. Color: Rose Blend. 11. Color: Red Blend. 12. Color: Burgundy Blend. 13. Color: Bordeaux Blend. 14. Color: Copper Canyon. 15. Color: Coppertone. 16. Color: Medium Ironspot No. 77. 17. Color: Medium Ironspot No. 46. 18. Color: Dark Ironspot. 19. Color: Manganese Ironspot. 2.6 HANDICAP DETECTABLE WARNING PAVERS 32 14 00-5

A. Handicap Detectable Warning Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface 1. Actual Product Size: 4 x 8 x 1-1/4 inches (102 x 203 x 32 mm). 2. Actual Product Size: 4 x 8 x 2-1/4 inches (102 x 203 x 57 mm). 3. Actual Product Size: 3-5/8 x 7-5/8 x 1-1/4 inches (92 x 194 x 32 mm). 4. Actual Product Size: 3-5/8 x 7-5/8 x 2-1/4 inches (92 x 194 x 57 mm). 5. Surface Protrusions: 8 raised protrusions per paver unit; 0.2 inches (5 mm) in height, tapering from 0.9 inches (23 mm) at the base to 0.75 inches (19 mm). 6. Compliance: ASTM C 902, Class SX, Type 1. 7. Compliance: ASTM C 1272, Type R, application PS. 8. Compliance: ASTM C 1272, Type R, application PX. 9. Compliance: ASTM C 1272, Type F, application PS. 10. Compliance: ASTM C 1272, Type F, application PX. 11. Color: Rose Blend. 12. Color: Red Blend. 13. Color: Burgundy Blend. 14. Color: Bordeaux Blend. 15. Color: Copper Canyon. 16. Color: Coppertone. 17. Color: Medium Ironspot No. 77. 18. Color: Medium Ironspot No. 46. 19. Color: Dark Ironspot. 20. Color: Manganese Ironspot. 21. Pattern: Herringbone 90 degree Pattern 10 ' T' spacers/sf; including perimeter 22. Pattern: Herringbone 45 degree Pattern 10 ' T' spacers/sf; including perimeter 23. Pattern: Running Bond Pattern 10 ' T' spacers/sf; including perimeter 24. Pattern: Basket Weave Pattern 7.5 ' T' spacers/sf and 1.5 ' +' spacers/sf; including perimeter 2.7 DANISH HAND MOULD PAVERS A. Danish Hand Mould Pavers: Nominal 4 inch x 8 inch brick pavers with wirecut surface 1. Actual Product Size: 3-5/8 x 7-5/8 x 2-5/8 inches (92 x 194 x 67 mm). 2. Color: Coppertone. 3. Color: Medium Ironspot No. 77. 4. Color: Medium Ironspot No. 46. 5. Color: Dark Ironspot. 6. Color: Manganese Ironspot. 7. Compliance: ASTM C 902, Class SX, Type 1. 8. Pattern: Herringbone 90 degrees. 9. Pattern: Herringbone 45 degrees. 10. Pattern: Running Bond Pattern. 11. Pattern: Basket Weave Pattern. 2.8 PAVER STEP TREADS A. Paver Step Treads: Brick paver step treads with wirecut surface texture as manufactured by Endicott Clay Products Co. 1. Actual Product Size: 11-5/8 x 3-5/8 x 2-1/4 inches (295 x 92 x 57 mm). 2. Actual Product Size: 7-5/8 x 7-5/8 x 2-1/4 inches (194 x 194 x 57 mm). 3. Radiused Edges: 1/2 inch (12 mm) radius on two adjacent 3-5/8 inch (92 mm) edges. 4. Compliance: ASTM C 902, Class SX, Type 1. 5. Compliance: ASTM C 1272, Type R, application PS. 32 14 00-6

6. Compliance: ASTM C 1272, Type R, application PX. 7. Compliance: ASTM C 1272, Type F, application PS. 8. Compliance: ASTM C 1272, Type F, application PX. 9. Color: Rose Blend. 10. Color: Red Blend. 11. Color: Burgundy Blend. 12. Color: Bordeaux Blend. 13. Color: Copper Canyon. 14. Color: Coppertone. 15. Color: Medium Ironspot No. 77. 16. Color: Medium Ironspot No. 46. 17. Color: Dark Ironspot. 18. Color: Manganese Ironspot. 2.9 PERMEABLE PAVERS A.. 1.. PART 3 EXECUTION 3.1 EXAMINATION AND PREPARATION A. Prepare substrates using the methods recommended by the manufacturer for achieving best result for the substrates under project conditions. B. Do not proceed with installation until substrates have been prepared using the methods recommended by the manufacturer and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions. C. If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions. 3.2 INSTALLATION A. Install pavers accordance with manufacturer's instructions and in proper relationship with adjacent construction. 3.3 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION 32 14 00-7