Review of options for cabin dosimetry & operation. Helen Amatiello & Colin Martin Health Physics Service Glasgow

Similar documents
USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

UV measurements for medical applications using SiC photodiodes

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Digital Sensors Erythema Sensor PMA2101

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Test One: The Uncontrolled Compartment Fire

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Understanding total measurement uncertainty in power meters and detectors

Development of a variable output LED-365 irradiance standard

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Dosimetry issues related to the SSRT project at the ESRF

UV LED Measurement Status Update

Radiation Environment on ISS in April 2013 According the Data from Liulin-5 Particle Telescope

Publication American Institute of Physics. Reprinted with permission.

AUBURN UNIVERSITY X-RAY SAFETY STANDARD OPERATING PROCEDURES

Victoreen & 660-8

6 th Pipeline Technology Conference 2011

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

Co-60 irradiator for therapy level calibrations at SSDLs

Development and setting up a calibration facility for UV sensors at high irradiance rates

UVC/T-M-AR stainless steel UV cabinet

SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

. ATP. Ultra-fast and reliable. CONSIS pouch packagers.

Forward-scattered radiation from the compression paddle should be considered when average (or mean) glandular dose is estimated

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

UVC in the Operating Room.

Characterization of dose impact on IMRT and VMAT from couch attenuation for two Varian couches

INTERNATIONAL STANDARD

BiliCare INTENSIVE PHOTOTHERAPY

Operating Manual UV Monitor UVT 18

VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS. C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E.

Methods for Floating Debris Removal Mark Hodder 14 February 2012

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

Temperature characterisation of LPG sensors for monitoring deterioration in reinforced concrete

Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance

AS/NZS IEC :2014

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

INTERNATIONAL STANDARD

PCR UV cabinets DNA/RNA

An FT-NIR Primer. NR800-A-006

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Beam Loss Position Monitoring with Optical Fibres at DELTA

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Quality Assurance of Radiation Protection Monitoring Instruments in India

Inline measuring of UV LED & conventional UV lamps

Griffin 824 Operational Suitability: Evaluation of Clear-Down Time for Mass Spectrometry- Based Trace Detector WHITE PAPER. Philip J. Tackett, Ph.D.

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

UV LED Curing: The Time is Now

PCR UV cabinets DNA/RNA

Optical Measurement Techniques for LED Clusters and LED Safety

OptoYag M. clear vision

Dosimetric verification of intensity modulated radiation therapy

Non Ionizing Radiation Audit checklist

Characterising the smoke produced from modern materials and evaluating smoke detectors

Dual-Diode Dosimeter Patient Dose Monitor

Low Cost Kinematic Couplings 2.75 Fall 2001

UVC/T-AR UVC/T-M-AR UVT-S-AR

North American Technical Services

North Dakota State University Laser Safety

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Recommendation Summary. Table 1: Recommended Energy Conservation Measures. Annual Energy Savings (est.)

Measuring Couch Motion Accuracy with X-ray Beam Fluence

WASTEWATER DISINFECTION

CURE ZONE (#A )

Black Cultural Center Sustainability Audit Report

SiC UV Sensor Probes Catalog

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Radiation Monitoring Systems

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE

César Chávez Cultural Center Sustainability Audit Report

Effect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension in a Standard Flat Bottom Agitated Vessel

CURE ZONE 2 (#A )

IEC/EN standards relating to diagnostic radiology equipment, and testing according to these standards

UVC/T-AR UVC/T-M-AR UVT-S-AR

MD456: Monitoring of abort gap population with diamond particle detectors at the BGI in IP 4

New Standard Requirements and Possibilities using UV-LED lamps for fluorescent Magnetic- Particle- (MPI) and Penetrant Inspection (FPI) in Aerospace

Dickeya solani survey of seed crops in England & Wales 2011

Experimental Investigation of Purification Function of Air Conditioner

Status Report of Active Space Radiation Detector, A-DREAMS-2 at NIRS

The development of a plastic scintillator for radiotherapy dosimetry

FDR D-EVO II G35 FDR D-EVO II G43

Telephone: +44 (0)

Photobiological safety of lamps and lamp systems

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

Temperature dependent Components within the Pyroelectric Detector

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

THERMOFOCUS 0800H5 Professional

Transcription:

Review of options for cabin dosimetry & operation Helen Amatiello & Colin Martin Health Physics Service Glasgow

Review of options for cabin dosimetry & operation Different centres have differing lamp replacement policies More centres using internal detectors to control patient dose for Tl01 phototherapy to account for gradual reduction in tube output with treatment hours Aims of study Aims of study Assess the influence of cold and hot spots on lamp replacement policy Investigate how patient position could affect detector reading and hence patient dose Investigate the contribution of lamp banks to the overall irradiance

Decline in Cabin Output with time 14 Measured irrradiance [mwcm-2] 13 12 11 10 9 8 7 6 5 4 3 2 1 0 cabin 1 cabin 2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 treatment hours [h] 30 40% reduction in cabin irradiance over 200 h Mean lamp lifetime ±1sd = 470 ± 170h

Influence of cold/hot spots Lamps failure produces an area of low irradiance a cold spot Defined as the magnitude of the irradiance in a quadrant where the tube has failed compared to a normal quadrant Similarly for a hot spot Historical data from West of Scotland automated UV dosimetry system 1,2 interrogated for various Tl01 cabin types 1 - Currie GD et al. 2001 An automated dosimetry system for testing whole-body ultraviolet phototherapy cabinets Physics in medicine and biology 46 333-45 2 - Evans AL et al. 2002 Instrument for scanning the angular variation of irradiance in ultraviolet phototherapy cabinets Journal of Medical Engineering & Technology 26(3)126-31

Automated UV Dosimetry System System to take 800 measurements of irradiance around 360 o rotation Radiometer Collimated detector Collimated detector to give indication of output from individual lamps (radiant intensity) Stepper motor in base Controlled by LAPTOP

Automated UV calibration system Dual detector head Rotation achieved using stepper motor controlled by integrated circuits

Influence of cold/hot spots (a) Irradiance Radiant Intensity UV 7001 40 tubes 1 out centre: 10% 2 adjacent: 18% 1 out corner: 7% 2 adjacent: 13% Failure of 1, 2, 3 adjacent lamps Hot spot: 4-5% 1 tube replacement

Influence of cold/hot spots (b) UV 1000 26 lamps Integral 20-25% reduction towards hinges due to cabin geometry 1 tube out centre: 7-10% 1-2 tubes out hinge:30-40% Failure of 3 lamps in one quadrant 3 lamps out: 55%

Influence of cold/hot spots (c) UV 7001k 13 tubes 30% reduction if one tube out 15% increase for replacement tube Also UV 5000 24 tubes 12% reduction if one tube out Failure of 1 lamp and its replacement 6-7% increase for replacement tube

Influence of cold/hot spots % irradiance variation of cold spots ~ double that of hot spots More significant for cabins with fewer lamps & dependent on cabin geometry Modern cabins localised erythema unlikely due to variation in irradiance (order of 10%) Older dual lamp cabins or smaller cabins lamp failures should be dealt with promptly (order of 30%)

Study of Internal detectors Tl01 cabins only 3 different types of cabin Developed a phantom with reflectance approximately the same as skin (Phantom: 5% ± 8%, Skin 4 7%) Allowed cabin warm-up to stabilise output Moved phantom in Anterior Posterior (AP) & Lateral directions, controlled from outside cabin during single run

Cabin Summary Unit N o Tubes Internal Detector Type Waldmann UV 7001 Waldmann UV 5000 Cosmedico GP 42 40 24 Dual UVA/TL01 21 Tl01 lamps Double detector Facing side banks Knee height Single detector Facing Patient right Knee height Double detector Facing 2 banks to Patient Right Above head height

Detector configurations UV 5000/7001 Dual Detector 7001 Single detector 5000 Cosmedico GP42 Dual Detector

Whole lamp banks covered and resulting internal detector reading recorded Bank dependency Relative dependency calculated as a percentage 30% 30% Measured 40% dependency from door bank negligible UV 7001 - Dual Detectors

Bank dependency UV 5000 - Single Detector 14% 12% 14% 56% 32% 20% 14% Cosmedico GP42 - Dual Detector 34%

Variation in irradiance Patient position Vs. relative irradiance (lateral direction)

Results % Dose Discrepancy Centre Offset [cm] UV 7001 Cosmedico GP42 UV 5000 AP LAT AP LAT AP LAT -10-2 -4 <1-3 0 37 10 5-3 <1 4-6 -50 Negative values indicate under-dosing

Results Few % difference between standard & large patients Single detector system outliers ±60% (for ±10-20cm offset) However, UV 5000 cannot be used with internal detector control Newer Waldmann UV 5001 has single internal detector with calibration performed without patient in cabin Results in a 15% patient attenuation coefficient dose discrepancy Cosmedico GP42 outliers ±10-15% for taller patients (for ±10-20cm offset)

Results Two bank dependency for Cosmedico GP42 (56%) If a single tube out on these banks, results in a 9 10 % reduction in detected cabin irradiance, compared to ~ 3% for other banks However, actual reduction in overall cabin irradiance will be ~ 5% 14% 14% 14% 56%

Conclusions Whole batch & single lamp replacement policies are considered equally acceptable provided there is a robust system to identify & replace failed lamps However, batch replacement will also have periods of failed tubes cold spots Waldmann 7001 cabin internal detector readings only varies by ±5% with patient position Waldman 5000 cabin readings varies by 50% with patient position, but not used to control treatment Cosmedico GP42 cabin readings vary by ±5% with patient position, but one lamp failure can change reading by 10%

Acknowledgements Stuart MacCalman & Graeme Phanco Health Physics Service Cameron Hosie Lanarkshire Acute Hospitals NHS Trust