mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity BTU/h 14339 14339 Power supply V-Hz-Ph 230-50-1 230-50-1 Rated power W MULTI SPLIT R410A & VRF SERIES R410A Air flow volume Static pressure Noise level Type of refrigerant m3/h Pa db(a) 1068 1048 1,35 480 (Turbo speed) 1068 1048 1,35 480 (Turbo speed) Body net dimension (WxHxD) mm Panel net dimension (WxHxD) mm 900x290x160 11,5/34 900x290x160 11,5/34 Body net weight Panel net weight Kg Kg 39/52 1/2 39/52 1/2 03
AUTO SELF FUNCTION Automatic functioning in heating or cooling mode Your Climate Your Control Close remote control Air circulation COOLING Best cooling performances in all conditions COSTANT DRY SYSTEM Constant control on humidity conditions Function mode On/off HEAT PUMP Confortable heat Time setting NIGHT TIME PROGRAM (SLEEP) Temperature set during the night Sleep mode LIGHTING DISPLAY You can switch on/off the backlight of the display Open remote control AIR CLEANING Constant air cleaning and dust removal 1 3 2 4 5 6 INFRARED REMOTE CONTROL Remote control ready for use to set all function AUTOMATIC FAN CONTROL MULTI SPEED Fan speed selection Auxiliary Heater Start or stop the electrical auxiliary heater Follow Me Button Adjust the action of indoor unit according to the temp. sensor inside the wire controller Timer Setting ON-OFF/OFF-ON TIMER On/off timer OK Button Confirm Operation Reset Button Reset all settings RESTART Auto-restart off all original settings in the event of a blackout 5 SECTIONS EXCHANGER 5 sections exchanger Mode Button Choose the mode Lock Button Lock or unlock all current settings Economy Button Start or stop economical mode Switch button With or without swing Temp. Button Present temperature ON/OFF Button
MITSUI is worldwide known for the technological innovation of its products and the commitment in researching a better environmental quality. MITSUI is ready to fulfil its most demanding customer s expectations in the air treatment field. AUTO ISO 9001 - CE The ISO 9001 certification represents the new worldwide recognised reference for the quality management of all productive sectors. The CE mark of conformity confirms that our products are in compliance with the actual regulations granting safety to the customer. Certified Quality Ecological refrigerants and reduced consumption in respect of the environment with MITSUI! Silent & Comfort MITSUI air conditioners are extremely silent both in normal and SLEEP function. Thanks to the new twisted torsion fan and the multi-section exchanger you can use your air conditioner also during the night without any noise. Ecological Policy The RoHS directive limits the use of dangerous substances in electrical and electronic appliances. It has been issued by the EU in order to limit the use of lead, mercury, hexavalent cadmium, PBB and PBDE in the products on the market. 03
Quadri DC Inverter dc inverter multi series AUTO DC Inverter Multi Series MODEL DUAL TRIAL QUADRI Capacity Cooling kw 1.8-5.7 1.8-8.4 1.8-11.3 Heating kw 1.9-6.2 1.9-8.8 1.9-11.8 Power Supply V-ph-Hz 220-240, 1, 50 Cooling RLA Ampere 7.9 11.7 11.4 Rated Power kw 1.9 2.7 3.2 Heating RLA Ampere 8.9 13.1 14.2 Rated Power kw 2.1 3.0 3.5 Performance Air flow Volume m3/h 2,400 2,400 3,000 Refrigerant Noise Level db(a) 50 50 51 EER 3.0 3.11 3.53 Energy Class B B A R410A Dimension WxHxD mm 845x695x335 845x695x335 895x860x330 Weight kg 61 68 70 Pipe Diameter Liquid mm Ø6.35 Ø6.35 Ø6.35 Gas mm Ø9.53 Ø9.53 Ø9.53 Max Pipe Length m 20 20 20 Max Difference m 10 10 10 Remarks: Nominal cooling capacity is based on the following conditions : indoor temp 27 CDB, 19 CWB, outdoor temp 35 CDB Nominal heating capacity is based on the following conditions : indoor temp 20 CDB, 7 CDW, outdoor temp 6 CDB 04
Dual DV Inverter Trial DV Inverter DC Inverter Multi Series Combination Table OUTDOOR UNIT INDOOR UNIT COMBINATION INDOOR UNIT CAPACITY (kbtu/h) TOTAL CAPACITY (kbtu/h) A B C D (kbtu/h) Dual Wall Mount 7+7 7 7 14-7/9/12 7+9 7 9 16 Duct 7+12 6.96 11.94 18.9-7/9/12 9+9 9 9 18 Cassette 9+12 8.1 10.8 18.9-7/9/12 12+12 9.45 9.45 18.9 Trial Wall Mount 7+7+7 7 7 7 21-7/9/12 7+7+9 7 7 9 23 Duct 7+7+12 7 7 12 26-7/9/12 7+9+12 6.95 8.94 11.92 27.81 Cassette 7+9+9 7 9 9 25-7/9/12 7+12+12 6.28 10.77 10.77 27.81 9+9+9 9 9 9 27 9+9+12 8.34 8.34 11.12 27.81 Quadri Wall Mount 9+9+18 6.95 6.95 13.91 27.81-7/9/12 9+12+12 7.58 10.11 10.11 27.81 Duct 9+12+18 6.42 8.56 12.84 27.81-7/9/12/18 12+12+12 9.27 9.27 9.27 27.81 Cassette 7+7+7+7 6.95 6.95 6.95 6.95 27.81-7/9/12/18 7+7+7+9 6.95 6.95 6.95 8.34 27.81 7+7+7+12 5.9 5.9 5.9 10.11 27.81 7+7+7+18 4.99 4.99 4.99 12.84 27.81 7+7+9+9 6.08 6.08 7.82 7.82 27.81 7+7+9+12 5.56 5.56 7.15 9.53 27.81 7+7+12+12 5.12 5.12 8.78 8.78 27.81 7+9+9+9 5.73 7.36 7.36 7.36 27.81 7+9+9+12 5.26 6.76 6.76 9.2 27.81 7+9+12+12 4.87 6.26 8.34 8.34 27.81 9+9+9+9 6.95 6.95 6.95 6.95 27.81 9+9+9+12 6.42 6.42 6.42 8.56 27.81 05
mini vrf AUTO The Mini VRF Advantages Available from 2.2kW to 16kW. Only two main refrigirant lines (liquid and gas pipe) required in one syste. In most large residential and light commercial buildings (such as villas and restaurants), more than one indoor unit is required which usually means multiple outdoor units which take up lots of space. With the Mitsui DC Iverter mini system only one outdoor unit is required. Exceptional Flexibility - Various indoor units can be chosen, including four-way cassette, duct, ceiling and floor, wall-mounted and floor-standing. State-of-the-art energy and cost efficiency Can be easily installed anywhere V80W V105W/S V105W V140W/S V140W V160W/S V160W Capacity Cooling kw 1.8-11.3 2-11.5 2-11.4 2-15 2-15 2-15.1 2-15.1 Heating kw 1.9-11.8 2.3-13.4 2.3-13.4 2.3-16 2.3-16 2.3-16.1 2.3-16.1 Power Supply V-ph-Hz 220-240-1-50 380-418-3-50 220-240-1-50 380-418-3-50 220-240-1-50 380-418-3-50 220-240-1-50 Cooling RLA Ampere 11.4 5.56 17.5 7.18 23 7.18 25 Rated Power kw 2.7 3.8 4 4.9 5.3 4.9 5.4 Heating RLA Ampere 13.2 6. 18.5 7.5 23.5 7.5 25 Rated Power kw 3 4.1 4.3 5.1 5.4 5.1 5.7 Performance Air Flow Volume m3/h 3000 5000 5000 6000 6000 6000 6000 Refrigerant Type Noise Level db(a) 51 53 53 54 54 54 54 EER 4.18 3.02 3.11 3.41 3.33 3.28 3.08 COP 3.93 3.26 3.11 3.33 3.40 3.35 3.09 Energy Class A B B A A A B R410a Dimension WxHxD mm 895x860x302 990x960x340 990x960x340 940x1245x340 940x1245x340 940x1245x340 940x1245x340 Weight kg 70 107 107 120 120 122 122 Pipe Diameter Liquid Side mm Ø6.35 Ø9.53 Ø9.53 Ø9.53 Ø9.53 Ø9.53 Ø9.53 Gas Side mm Ø12.7 Ø15.9 Ø15.9 Ø15.9 Ø15.9 Ø15.9 Ø15.9 Max Pipe Length m 50 70 70 70 70 70 70 Max Difference m 20 20 20 20 20 20 20 Remarks: Nominal cooling capacity is based on the following conditions: indoor temp 27 CDB, 19 CWB, outdoor temp 35 CDB Nominal heating capacity is based on the following conditions: indoor temp 20 CDB, 7 CDW, outdoor temp 6 CDB 06
VRF2 DIAGRAM OF BUILDING vrf II AUTO The Ulimate in Flexibility Longer pipe and communication wires: Pipe length: 175m max Height difference of in-door and out-door units: 70m max Communication wire: 1200m max Easier refrigerant charge as system runs in cooling mode by forced cooling button. System is equiped with a Self-Diagnostic function - Detects and indicates mulfunctions caused in major locations to facilitate servicing and maintenance. Neat appearance - Every outdoor module has exactly the same dimensions, so there is consistency even when multiple modules are combined. Auto-Restart function - When the system is shut down by power failure, settings are automatically retained when system restarts. No need to re-program. Precise Room Temperature Control - Electronic Expansion Valves automatically responds to any load change in the indoor unit to control and secure flow rate of refrigerant in operation to assure constant room temperature. This is completely different from the traditional on/off type control system. The Inverter Smart System will maintain room temperature within 0.5 degrees celcius fifference from temperature set. Various Combinations Connectable indoor unit capacity Ratio up to 150% Connectable indoor unit number up to 48 Wide variation of indoor units 11 types - 49 models 07
Latest Energy and Cost Saving Technology DC Inverter scroll type compressor instead of the traditional compressor with parallel connection. During part load mode, the Inverter scroll type compressor runs while during full load mode, both compressors run. During middle frequency range (40-90Hz), the Inverter Compressor runs with higher efficiency, lower noise and vibration. Inverter Compressor has higher EER and faster cooling and heating in operation. Traditional compressor can output 100% capacity in shorter time. Product Exploded View PHOTO OF INSIDE OF UNIT WITH DESCRIPTIONS The DC Inverter System Our Inverter air conditioners offer the highest technology in domestic air conditioning field. These units use a variable rotation compressor whose speed changes according to the space exigencies. Proceed at constant speed but it needs more time to achieve the comfort value The ambient gets cooler too quickly and gets hotter too quickly The room temperature obtained with an Inverter air conditioner keeps constant reducing the thermal cycling; the system is more silent reaching an energy saving of almost 40%. This system is particularly useful to heat in heating pump function during winter when the outdoor temperature is very low. Inverter Functioning When switched on, the Inverter units use the compressor at its maximum power to reach the desired temperature in a very short time. Once reached the wished temperature the Inverter system can keep it in a range of +/- 0,5 C. This tolerance cannot be obtained with an air conditioner without the Inverter technology. Compressor On/off Inverter compressor AC Inverter compressor DC It achieves quickly the comfort value It controls the temperature in more economical manner A pleasant temperature all the time 08
Intelligent Built-in Manager System The Intelligent Manager is an integrated building management system (BMS) that uses our independent, high-speed multi-transmission method. It has a centralised controller function whuch can perform high-speed centralised control of our commercial A/C for buildings. SDV III System has various control solutions: Individual control, group control, network control, etc. One computer can monitor a maximum of 16 central controllers One central controller can monitor a maximum of 64 indoor units One computer can monitor a maximum of 1024 indoor units Max=32 Lonwork Max=64 Built-in manager system Max=16 Max=64 Touch Controller Central Controller Remote Controller MODEL V252W V280W V335W V400W V450W Capacity Cooling kw 25.2 28 33.5 40 45 Heating kw 27 31.5 35 43 47 Power Supply V-ph-Hz 380-3-50 Cooling RLA Ampere 15.4 16.6 18.7 20.8 24.1 Rated Power kw 7.85 8.45 9.97 10.52 12.57 Heating RLA Ampere 13.9 15.3 16.8 18.3 21.5 Rated Power kw 7.04 7.95 9.09 10.10 11.99 Performance Air Flow Volume m3/h 11500 11500 11500 14800 14800 Noise Level db(a) 60 60 60 62 62 EER 3.21 3.32 3.36 3.81 3.58 COP 3.83 3.96 3.85 4.25 3.92 Energy Class A A A A A Refrigerant Type R410A Dimension WxHxD mm 980x1630x800 900x1630x800 980x1630x800 1380x1630x830 1380x1630x830 Weight kg 290 290 290 380 380 Pipe Diameter Liquid Side mm Ø12.7 Ø12.7 Ø12.7 Ø15.9 Ø15.9 Gas Side mm Ø25 Ø25 Ø25 Ø35 Ø35 Max Pipe Length m 175 175 175 175 175 Max Difference m 15 15 15 15 15 Remarks: Nominal cooling capacity is based on the following conditions : indoor temp 27 CDB, 19 CWB, outdoor temp 35 CDB Nominal heating capacity is based on the following conditions : indoor temp 20 CDB, 7 CDW, outdoor temp 6 CDB 09
HORSE POWER (HP) MODEL COMBINATIONS MAX INDOOR UNITS 8 V252W 8 13 10 V280W 10 16 12 V335W 12 16 14 V400W 14 16 16 V450W 16 20 18 V532W 8+10 20 20 V560W 10+10 20 22 V615W 10+12 20 24 V680W 10+14 20 26 V730W 10+16 20 28 V785W 12+16 20 30 V850W 14+16 32 32 V900W 16+16 32 34 V960W 10+10+14 32 36 V1010W 10+10+16 32 38 V1065W 10+12+16 32 40 V1130W 10+14+16 40 42 V1180W 10+16+16 40 44 V1235W 12+16+16 40 46 V1300W 14+16+16 40 48 V1350W 16+16+16 40 50 V1405W 12+12+12+14 50 52 V1455W 12+12+12+16 50 54 V1520W 12+12+14+16 50 56 V1570W 12+12+16+16 50 58 V1630W 10+16+16+16 50 60 V1685W 12+16+16+16 64 62 V1750W 14+16+16+16 64 64 V1800W 16+16+16+16 64 10
indoor units AUTO Ceiling & Floor MODEL D36DL D45DL D56DL D71DL D80DL D90DL D112DL D140DL Capacity Cooling kw 3.6 4.5 5.6 7.1 8 9 11.2 14 Heating kw 4 5 6.3 8 9 10 12.5 16 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 130 140 140 140 155 155 240 240 Performance Air Flow Volume m3/h 650 800 800 800 1400 1400 2000 2000 Noise Level db(a) 40 43 50 50 51 51 51.6 51.6 Refrigerant Type R410A Dimension Body (WxHxD) mm 995x660x199 1285x660x199 1670x680x240 Weight Body kg 29 37 54 Pipe Diameter Liquid Side mm Ø6.35 Ø9.53 Gas Side mm Ø12.7 Ø15.9 Water Drain mm ODØ25 11
Four-way Cassette - Compact MODEL D28Q4 D36Q4 D45Q4 Capacity Cooling kw 2.8 3.6 4.5 Heating kw 3.2 4 5 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 65 65 75 Performance Air Flow Volume m3/h 860 Noise Level db(a) 37 Refrigerant Type R410A Dimension Body (WxHxD) mm 580x254x580 580x254x580 580x254x580 Panel (WxHxD) mm 650x30x650 650x30x650 650x30x650 Weight Body kg 22 24 24 Panel Kg 3 3 3 Pipe Diameter Liquid Side mm Ø6.35 Gas Side mm Ø12.7 Water Drain mm ODØ25 Four-way Cassette MODEL D56Q4 D71QD D80Q4 D90Q4 D112Q4 Capacity Cooling kw 5.6 7.1 8 9 11.2 Heating kw 6.3 8 9 10 12.5 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 100 100 100 130 145 Performance Air Flow Volume m3/h 1000 1200 1200 1320 1860 Noise Level db(a) 38 42 42 44 44 Refrigerant Type R410A Dimension Body (WxHxD) mm 955x260x955 955x260x955 955x325x955 955x325x955 955x325x955 Panel (WxHxD) mm 1030x145x1030 1030x145x1030 1030x145x1030 1030x145x1030 1030x145x1030 Weight Body kg 25 25 25 34 34 Panel Kg 6 6 6 6 6 Pipe Diameter Liquid Side mm Ø9.53 Gas Side mm Ø15.9 Water Drain mm ODØ32 12
Low Static Pressure Duct MODEL D22T2 D28T2 D36T2 Capacity Cooling kw 2.2 2.8 3.6 Heating kw 2.6 3.2 4 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 50 50 50 Performance Air Flow Volume m3/h 580 Noise Level db(a) 34 Static Pressure Pa 10 Refrigerant Type R410A Dimension Body (WxHxD) mm 955x210x385 955x210x385 955x210x385 Weight Body kg 15 15 15 Pipe Diameter Liquid Side mm Ø6.35 Gas Side mm Ø12.7 Water Drain mm ODØ25 Duct MODEL D45T2 D56T2 D71T2 D80T2 D90T2 D112T2 D140T2 Capacity Cooling kw 4.5 5.6 7.1 8 9 11.2 14 Heating kw 5 6.3 8 9 10 12.5 16 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 150 150 160 160 220 220 220 Performance Air Flow Volume m3/h 1160 1460 2400 Noise Level db(a) 38 42 44 Static Pressure Pa 40 70 Refrigerant Type R410A Dimension Body (WxHxD) mm 1000x298x800 1350x298x800 Weight Body kg 38 38 38 38 48 51 51 Pipe Diameter Liquid Side mm Ø9.53 Gas Side mm Ø15.9 Water Drain mm ODØ32 13
Wall-Mounted MODEL D22G D28D D36G D45G D56G Capacity Cooling kw 2.2 2.8 3.6 4.5 5.6 Heating kw 2.5 3.2 4 5 6.3 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 50 50 50 60 60 Performance Air Flow Volume m3/h 580 1150 Noise Level db(a) 36 39 Refrigerant Type R410A Dimension Body (WxHxD) mm 790x265x195 920x292x225 Weight Body kg 11 15 Pipe Diameter Liquid Side mm Ø6.35 Gas Side mm Ø12.7 Water Drain mm ODØ15 Wall-Mounted - EXV Integrated MODEL D22G/Y D28D/Y D36G/Y D45G/Y D56G/Y Capacity Cooling kw 2.2 2.8 3.6 4.5 5.6 Heating kw 2.5 3.2 4 5 6.3 Power Supply V,Hz,ph 220-240,50,1 Rated Power W 19 22 28 34 40 Performance Air Flow Volume m3/h 380 450 580 720 800 Noise Level db(a) 39 39 40 41 41 Refrigerant Type R410A Dimension Body (WxHxD) mm 915x289x216 1080x315x216 Weight Body kg 12 14 Pipe Diameter Liquid Side mm Ø6.35 Gas Side mm Ø12.7 Water Drain mm ODØ15 14
Please read the Installation Manual carefully before installing the unit, and read the Operating Manual before using. Specifications are subject to change without notice for further improvement. Due to printing considerations, the actual colours may vary slightly from those shown. 15
Your MITSUI Agent AUTO