TECH. Declaration of conformity no 23/2007

Similar documents
Declaration of Conformity No. 27/2008

Declaration of Conformity no. 56/2012

ST 53.1 User s manual

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3M

SOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS

EUROSTER 11E CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

BW Type Solid Fuel Boilers Installation and Maintenance Instructions

OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

EUROSTER 11W CENTRAL HEATING SYSTEM CONTROLLER

INSTRUCTIONS OF POLLEN DRYER 4 KG

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

EUROSTER 11B UTILITY HOT WATER TANK PUMP CONTROLLER

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

bruli.pl V3.5 Operating manual Kutno Software version:

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

ecomax 800, model R1 Boiler regulator Dzia Zintegrowanego Systemu Zarz dzania version: ec FOR SOLID FUEL-FIRED BOILERS WITH FEEDING SCREW

GA01HC-02. Service manual. Room Panel. Programme version 01a. Operating with GH07EA regulator for controlling electrode boilers

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Product waste disposal - Protection of the environment:

ecoal.pl V3.5 Adaptive controller Operating manual Kutno Software version:

Digital Room Thermostat

Controller PCSol 300 FOR SOLAR COLLECTORS. INSTALLATION AND OPERATION MANUAL 62.X.2 REVISION SOFTWARE

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Digital Electronic Thermostat With RF

The MCD-111 AUTOKLAW Microprocessor Controller Version 1.00 User s Manual

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Dohse Aquaristik GmbH & Co. KG

INSTRUCTION FOR THE USER THC V E OIL BLU

KFP-CF Series Operation Manual

BILL COUNTER (NCOUNTER) OPERATION MANUAL

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Dohse Aquaristik GmbH & Co. KG

Instruction manual. Remote control electric IR HEATER

Digital Electronic Thermostat With RF

User instructions DHP-AT

- Data Brochure Mixing Control 361

WHA 3000P Hot Air Station

Model: RT510RF. Installation Manual

ATM Lighting sp. z o.o

Installer Manual KNX Touchscreen Thermostat

Installation and user manual

O CRC100. Comfort Room Controller (2015/01) en

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

- Data Brochure D 260. Boiler Control /09

MANUAL INTELLIVENT CELSIUS

PHASE DMC USER S MANUAL

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

OPERATION INSTRUCTION

- Data Brochure Steam Control 279

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

User Guide Digital Bill Counter AB4000

Monitoring Software for NPBC-V3M-1 User Manual

Instructions for the fan motor control system, SILVER C

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

HR 601 C A AUS. ENGLISH Instructions for use Page 2

- Data Brochure Mixing Control 360

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

GMM Güntner Motor Management

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

ECL Comfort 110, application 130

APC BC300 Series 40kW 208/450/480V User Guide

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

- Data Brochure Snow Detector & Melting Control 665

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

ECL Comfort 110, application 116

Installation Guide. ECL Comfort 210, application A Table of Contents

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Installation and Operating Manual

REGULATOR TIS TRONIC 496P

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Multi Boiler Guide. Kit #

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

testo 316-EX gas leak detector Instruction manual

Air-Water heat pump Small GT

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

USER MANUAL ACQUAHOME 32 B BLU

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Dryer Controller M720

- Data Brochure Universal Reset Module 422

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

- Data Brochure Universal Reset Module 423

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Transcription:

ST-81 USER'S MANUAL TECH Declaration of conformity no 23/2007 We, company Tech, ul. St. Batorego 14, 34-120 Andrychów declare with full responsibility that ST-81, 230 V, 50 Hz thermo regulator that we manufacture meets the requirements of Ordinance of the Minister of Economy (Dz.U. Nr 155, poz. 108) from 21st August 2007 which implements LVD 2006/95/EC from 16.01.2007 into Polish law. ST-81 controller has passed EMC compatibility test with optimal loads. For assessment of conformity harmonized standards PN-EN 60730-2-9:2006 have been used. Co-owners: Paweł Jura, Janusz Master -2-

TECH CAUTION! ELECTRICAL EQUIPMENT UNDER VOLTAGE! Before starting any actions concerning montage (connection of cables to the pump, installation of the device etc.) it is essential to make sure that the thermo regulator is not powered! All connection works must only be carried out by qualified electricians. Before activating the controller, measure the motor resetting efficiency, check the boiler and inspect wire insulation. -3-

Przycisk PLUS Przycisk MINUS Nadmuch Pompa PompaCO CWU Praca ręczna Przycisk wejścia Przycisk powrotu do podmenu, z menu, zatwierdzania anulowania Wyłącznik ustawień ustawień sieciowy

TECH Button PLUS Button MINUS Entering menu and approving settings Power switch Exit, cancelling settings Blow Manual operation HCW pump CH pump I. Description ST 81 thermo regulator is designed for controlling CH boilers. It is regulating the pump responsible for CH water circulation, HCW pump and the blow (fan). The main advantage of this thermo regulator is the simplicity of its operation. The user is able to change all the parameters by the means of knob of the pulse generator. Another advantage is a large and easily readable graphic display which allows the user to precisely inspect the actual status of the boiler operation. All remarks on the software should be forwarded to the manufacturer of the boiler. Each thermo regulator should be set up in accordance with specific needs, basing on the type of fuel used and the type of the boiler. TECH does not take any responsibility for incorrect set up of the thermo regulator -5-

ST-81 USER'S MANUAL I.a) Basic Terms Fire up The cycle begins when you activate the fire up function in the controller's menu and is active until the central heating boiler temperature reaches 40oC (the default fire-up threshold), on condition that the temperature does not drop below this value for 2 minutes (the default fire-up time). If these conditions are met, the regulator will switch to the operation mode and the manual operation symbol on the housing will be deactivated. If the controller fails to reach parameters required for entering into the operation mode within 30 minutes from activation of the fire-up function, the "Unable to fire up" message will appear on the display. In such a case, the fire-up cycle needs to be restarted Operation The operation cycle is the basic functionality of the regulator, in which the Power of the blow is regulated by the user. If the temperature rises above the set temperature a so called suspension mode will be activated. Suspension mode this mode will be activated automatically if the temperature is equal or higher than the set temperature. In that case, in order to ensure smooth decrease of temperature of circulating water it is necessary to properly set operation times of the fan. Damping if boiler temperature drops by 2oC below the fire-up threshold and fails to rise above this value for 60 minutes (default damping time), the regulator will switch to the damping mode. While in this mode, the fan is deactivated and the display shows "Damping". In case of voltage loss, the regulator ceases to operate. When power is restored, the controller returns to parameters using its built-in memory. -6- operation with previously set

TECH II. Functionality of the regulator This chapter describes the functionality of the thermo regulator, means of changing the settings and moving around in the menu. II.a) Main Page 53 Oc CH 55 Oc * set B During normal operation of the thermo regulator (in only CH mode) the LCD display shows the main page which presents the following information: Boiler temperature (on the left side of the display) Set temperature (on the right side of the boiler) Symbol of non-operating fan (*) Symbol of current operations mode or symbol of an active room regulator. This screen allows for quick change of the set temperature, by the means of PLUS and MINUS buttons. Pressing down OPTIONS moves the user to the 1st level menu, the display then shows the first two rows of the menu. In each menu the user can move up and down by the means of PLUS and MINUS buttons. Pressing down OPTIONS moves the user to the consecutive menu or enables a specific function. EXIT moves the user back to the root menu. II.b) Fire up This function starts up the fan during fire up sequence. In the case that the boiler reaches the temperature higher than 40 degrees but it will not reach the set temperature this button acts as a START/STOP, the display will show Start/Stop fan instead of fire up. If the fan is not operating, a star symbol will appear in the upper right corner of the -7-

ST-81 USER'S MANUAL display. This function allows the user to safely operate the boiler. If the fan is turned on it is forbidden to open the furnace door. This setting allows to temporarily switch off the fan at any time e.g. during feeding fuel. If, during fire up sequence the boiler will not reach 40 degrees (default damping threshold) during 30 minutes the display will present the following alarm: 33 Oc 55 Oc Unable to fire up In this case the user should restart the fire up sequence the thermo regulator will once again start the fire up sequence. II.c) Manual operation In order to increase the Comfort of the user the thermo regulator is fitted with manual operation mode. In this mode each executive element can be switched off and on independently from all the other elements. 53 Oc CH 55 Oc * set B Pressing down OPTIONS starts the fan, which remains turned on until the next pressing of the OPTIONS button. Blow force Blow Pressing down OPTIONS Turns on/ off CH water pump. Blow CH PUMP Naciśnięcie OPCJE załącza / wyłącza pompę C.W.U. (bojlera). CH PUMP HCW pump -8-

TECH Naciśnięcie OPCJE załącza / wyłącza alarm. -9-

ST-81 USER'S MANUAL HCW PUMP alarm II.d) Pumps (CH and HCW) switch on temperature 42 Oc CH 55 Oc * Set D Manual operation Pumps switchon temp 35oc Pumps switchon temp This option is used in order to set the switch on temperature of the CH and HCW pump (it is measured in the boiler). If the temperature increase above the set level the pumps will switch on. The pumps will switch off after the temperature drops below the set temperature (minus 2 degrees of hysteresis), in this case the pump will switch when the temperature in boiler drops below 33 degrees. II.e) Hysteresis of the boiler 62oc CH temp. 72oc set Pump switchon temp. 2oc hysteresis This option can be used to set the hysteresis of the set temperature. It is the difference between the temperature of start of the suspension mode and the temperature of restarting the operation mode (e.g. when value of the set temperature is 60ºC and hysteresis is 2ºC, the start of the suspension mode will take place at 60ºC, whereas the restart of the operation mode will take place at 58ºC. Hysteresis can be set in the range between 2ºC and 6ºC. - 10 -

TECH II.f) HCW hysteresis 62oc CH temp 72oc set Boiler hysteresis HCW hysteresis 5oc hysteresis This option can be used to set the value of the hysteresis of the boiler set temperature. It is the difference between the set temperature (that is the boiler required temperature) and the actual boiler temperature (e.g. if the set temperature has the value of 55ºC, and the hysteresis is 5ºC. After the set temperature (55ºC) is reached the HCW pump will switch off and the CH pump will switch on. The HCW pump will restart if the temperature decreases to 50ºC. II.g) Blow force 62oc 72oc CH temp Set HCW hysteresis Blow force 5 gear Blow force This function allows to choose the operations speed of the fan. Range of regulations is between 1 and 10 (one can assume those are the gears of the fan). The higher the gear the faster the operation of the fan, whereas gear 1 is the minimal speed and gear 10 is the maximal speed. Change of gears is being done by the means of PLUS and MINUS buttons. The fan always starts up with the maximal speed which allows it to start operation even with some amount of dust present in the engine. II.h) Modes of operation This function allows the user to choose one of four different modes of operation. - 11 -

ST-81 USER'S MANUAL 42 Oc CH 55 Oc * Set D HCW pump temp Modes of oper. A proper symbol for each operation mode is shown in the lower, right corner of the display. Depending on the mode of operation a specific letter is displayed: D( ) house heating, B( ) boiler priority, R( ) paralel pumps, L( ) summer mode. II.h.1) House heating House Heating * H.C.W. Priority 42 Oc CH 55 Oc * Set D If you select this option, the regulator will switch to the house heating mode. The central heating pump starts to run above the pump activation temperature (set to 35OC by default). Below this temperature (minus central heating hysteresis of 2OC), the pump is shut off. While in the house heating mode, the letter D is displayed in the bottom right corner of the main screen. II.h.2) HCW priority House Heating H.C.W. Priority * 23Oc 23Oc 50oc * CH HCW Set B Activating the hot consumption water priority will cause the regulator to switch into the water heater priority mode. In this mode, the (hot consumption water) heater pump is activated until the set H.C.W. temperature is reached. Then, the H.C.W. pump is shut off and the C.H. pump is activated. The central heating pump will run until the water heater temperature drops below the set point value (and the - 12 -

TECH H.C.W. hysteresis); then, the C.H. pump is shut off and the H.C.W. pump is activated. In this mode, the fan is operated as long as the temperature is below 62 C to prevent the boiler from overheating. The hot consumption water priority function consists in that the consumption water is heated up before heating up water in radiators. Change button of the set HCW temperature can be done by pressing (holding down for a few seconds). The display will show the HCW temperatures screen for a few moments. Set temperature can changed with buttons. After few seconds the display will return to its previous state. When HCW priority mode is on the main the letter B is show in the lower right corner of the display. ATTENTION: The boiler should have non-return valves mounted on the central heating pump circuit and the hot consumption water pump circuit. A valve mounted on the hot consumption water pump will prevent hot consumption water from being drawn from the water heater. II.h.3) Parallel Pumps H.C.W. Priority Parallel Pumps * 42 Oc CH 55 Oc Set * R In this mode, the pumps start to run in parallel above the pump activation temperature (set by default to 35 OC). The central heating pump runs continuously, while the hot consumption water pump stops after the set point temperature is reached in the boiler; it then restarts when the temperature drops by 2OC. Change button of the set HCW temperature can be done by pressing (holding down for a few seconds). The display will show - 13 -

ST-81 USER'S MANUAL the HCW temperatures screen for a few moments. Set temperature can changed with buttons. After few seconds the display will return to its previous state. ATTENTION: In this mode, a non-return valve should be fitted to maintain different temperatures in the water heater and in the house. After activation of the parallel pumps function, three items appear on the display. Starting from the left, these are: Boiler Temperature (C.H.); Water Heater Temperature (H.C.W.) and Set point Temperature (C.H.). When parallel pumps mode is on the letter R is show in the lower right corner of the display. II.h.4) Summer Mode Parallel Pumps Summer Mode * 45 Oc 43 Oc C.H. H.C.W. 55 Oc * Set L When the function is enabled, only the hot consumption water pump is running in order to heat water in the water heater. The pump is switched on above a predefined activation threshold (see the pump activation temperature function) and will run until the set point temperature has been reached. The pump will start again when the temperature drops below the set hysteresis. In the Summer Mode, only the set point temperature is set on the boiler that heats up water for the water heater (the temperature set for the boiler is also the temperature set for the water heater).while in the Summer Mode, the letter L is displayed in the bottom right corner of the main screen. - 14 -

TECH II.i) Room regulator 62oc CH temp 72oc Set Operation mode Room regulator ON OFF ST-81 thermo regulator allows a room regulator to be connected in the system. In this mode the thermo regulator is being controlled by the room regulator and does not take into account the temperature set on thermo regulator main unit. Blow is operating until the temperature set on the room regulator is reached. However the operation of the boiler is limited by the temperature set on the thermo regulator mounted on the boiler. CONNECTION OF THE ROOM REGULATOR: there is a 2-lead cable coming out of the room regulator which should be connected to the montage slit of the thermo regulator in the position described as room regulator. ATTENTION: no external voltage can be connected to the room regulator II.j) Suspension operation This option allows the user to set the time of operations of the fan (blow) in the suspension mode (above the set temperature). II.k) Suspension pause This option allows the user to set the time of the pause in the fan operation during the suspension in order to prevent the boiler burn out, in case when the temperature will hold over the set point value. ATTENTION: Improper setting of this option may cause a constant rise of the temperature! Suspension pause shouldn t be too short. - 15 -

ST-81 USER'S MANUAL II.l) Language 23Oc 23Oc 50oc CH HCW Set Suspension pause Language choice Polski * English This function allows the user to change the language version of the thermo regulator II.m) Factory settings 23Oc 23Oc 50oc CH HCW set Const. CH pump Factory settings Yes No The thermo regulator is preset for operation. However it is necessary to adjust it to one s specific needs. There is always the possibility of returning it to factory (default) settings. Switching on this function will cause the user to lose all personal device settings which will be replaced by the settings saved by the manufacturer (this does not apply to settings of the service menu). At this point it is possible to re-set personal settings of the controller. III. Safeguards In order to ensure a safe and faultless operation, the regulator has been provided with numerous protections. In the case of an alarm, an acoustic warning is sounded and the display shows a corresponding message. Press OPTIONS to restore the controller to operation. In the case of the C.H. Temperature Too High alarm, wait until the temperature drops below the alarm value. III.a) Thermal protection The boiler is protected with an additional bimetal sensor (located at the boiler temperature sensor) that disables the fan when the temperature exceeds the critical value: 85OC. This is to prevent water from boiling in the system when the boiler has been overheated or the controller is damaged. When the protective function is enabled and the temperature drops to a safe value, the sensor will automatically restart the device and - 16 -

TECH the alarm will be deactivated. If the sensor is damaged or overheated, the fan is disabled. III.b) Automatic sensor check In case when the CH temperature sensor is missing or damaged an alarm is activated, which additional reports the fault on the display e.g.: alarm CH sensor damage The blow is being turned off, whereas CH and HCW pumps are operating independently from the current temperature, each in accordance with its specific settings. In case of CH sensor damage, the alarm will remain active until the sensor is replaced. If the HCW sensor is damaged, the user should press OPTIONS which will turn off the alarm and the thermo regulator will return to one pump operation (house heating). In order for the boiler to operate in all modes the sensor needs to be replaced. III.c) Temperature protection The regulator features an additional protection in case the bimetal sensor is damaged. After the temperature exceeds 85 OC, the alarm is sounded with the display showing the following message: Alarm Temp. Too High The current temperature is read from an electronic sensor and processed by the thermo regulator. When the alarm temperature is exceeded, the fan is shut off and both pumps begin to run in order to distribute hot consumption water throughout the system. III. d) Anti-boil protection This protective function is used only with the water heater priority mode. For example, when the water heater setpoint temperature is 55 OC and the boiler temperature rises to 65 OC (so-called priority temperature), the controller shuts off the fan. If the boiler temperature reaches 80 OC, the C.H. pump will be activated. If the temperature continues to rise, the alarm will be activated at 85OC. Such condition may appear when the water heater or the pump is damaged or when the sensor has been improperly installed. However, if the temperature drops, the controller will activate the fan at 63OC and it will remain in the duty mode maintaining the priority temperature of 65OC. - 17 -

ST-81 USER'S MANUAL 1.III.e) Fuse The regulator has a network protection WT 3.15 A tube fuse. ATTENTION: Higher current ratings may cause damage to the controller. IV. Maintenance Before and during the heating season, the ST-81 controller should be checked for condition of its cables. You should also check if the controller is properly mounted and clean it if dusty or dirty. It is advisable to measure grounding parameters for the motors (central heating pump, hot consumption water pump and fan). Technical Specifications No. Specification Unit 1 Supply voltage V 230V/50Hz +/-10% 2 Power consumption W 5 3 Ambient temperature O 4 C 5 50 Circulation pump outlet load A 0,5 5 Fan outlet load A 0,6 6 Temperature measurement range O C 0 85 7 Measurement accuracy O C 1 8 Temperature adjustment range O C 45 85 9 Sensor thermal resistance O C -25 90 A 3,15 10 Fuse insert V. Assembly ATTENTION: all assembly works must only be carried out by qualified persons. During assembly, the device must be disconnected (make sure the power cord is unplugged)! ATTENTION: improper cable connections may damage the regulator! Installation should be performed according to standard PN-EN303-5. - 18 -

TECH V.a) Cable Connection Diagram for Controller Pay special attention to cable connections during assembly. Especially, the ground wire should be connected properly. We are committed to protecting the environment. Manufacturing electronic devices imposes an obligation of providing for environmentally safe disposal of used electronic components and devices. Hence, we have been entered into a register kept by the Inspection For Environmental Protection. The crossed-out bin symbol on a product means that the product may not be disposed of to household waste containers. Recycling of wastes helps to protect the environment. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled. - 19 -

TECH Contents I. Description...5 II. Functionality of the thermo regulator...7 II.a) Main Page...7 II.b) Fire up sequence...7 II.c) Manual operation...8 II.d) Pumps' switch on temperature (CH and HCW)...9 II.e) Hysteresis of the boiler...9 II.f) HCW hysteresis...10 II.g) Blow force...10 II.h) Modes of operation...11 II.h.1) House heating...11 II.h.2) HCW priority...11 II.h.3) Parallel pumps...12 II.h.4) Summer mode...13 II.i) Room regulator...14 II.j) Suspension operation...14 II.k) Suspension pause...14 II.l) Language...15 II.m) Factory settings...15 III. Safeguards...15 III.a) Thermal protection...15 III.b) Automatic Sensor Check...16 III.c) Temperature protection...16 III. d) Anti-boil protection...16 III.d) Fuse...17 IV. Maintenance...17 V. Assembly...17 V.a) Cable Connection Diagram for Controller...18-21 -

ST-81 USER'S MANUAL - 22 -