SPHERE-STR LED WLL WSHER SPECIFICTION SHEET LISTED Features UL 153 portable electric luminaire Die-cast aluminum shell / tempered glass IP 65 Indoor/outdoor 150 rotary angle DMX-512 control pplications & Uses Indoor/outdoor social events: parties, weddings Corporate engagements & trade shows Restaurants & dance clubs Gardens & outdoor accents Exterior & architectural lighting Indirect & accent lighting illboards & outdoor signage Item # Color Input Voltage ¹ Kelvin eam ngle Projection Distance Lumens (Max) Power Consumption IP Rating Chips per Unit Max Run EL-P64WSH-15RG RG 100-256VC - 15 65ft. 1931 lm 55W IP 65 36 10 Fixtures EL-P64WSH-15NW White 100-256VC 6000K 15 65ft. 3600 lm 55W IP 65 36 10 Fixtures Finish Color lack Input Voltage ¹ 100-256VC Frequency 50/60Hz Input Connection NEM 5-15 C power plug (56 in. length) Operating Voltage 24VDC Power Consumption 55W (max) 1ea. male/female wet location 3-pin M14 Linkable Connections ² cables (IP67 rated. 18 in. length). M14- to-xlr-3 adapter cables also included. Operating Temp. -4 ~ 104 F (-20 ~ 40 C) Housing / Cooling Die-cast aluminum casing; tempered glass / cooling by free air convection Mounting Removeable tilting surface-mount bracket w/ (3x) 1/2 in. mounting holes Rotary ngle 150 LED Chip Type Edison Chips per unit 36 chips; RG washer - R=12, =12, G=12 eam ngle 15 Kelvin Rated Fixture Lumens (lm) (max) Luminous Efficacy (lm/w) Projection Distance Rated Lamp Life Control Dimmable? ³ Maximum Series Run Height Diameter Weight IP Rating / Location Safety Standards Warranty RG or White (6000K) RG (R=615, G=1038, =278, Total=1931 lm) / White (6000 lm) 12 lm/w - 49 lm/w 65ft. 50,000 hours DMX-512 control, 3 addresses per fixture May be dimmed/controlled using onboard controls or with a compatible DMX-512 controller. 10 fixtures 6.69 in. (9.21 in. with mounting bracket) 7.88 in. (8.35 in. with mounting bracket) 8.82 lbs. IP65 Indoor/Oudoor Resists sprays, suitable for damp locations UL 153 pproved. UL # E336476, CE 2 Years Note ¹ Only UL Listed for connection with a 120VC, 15- or 20-ampere branch circuit. Note ² When installing outdoors or in a damp location, ensure water-resistant end caps are connected to all wet location 3-pin M14 cables. If attaching XLR-3 DMX adapter cables seal all standard XLR-3 connections with 1.25 heat shrink and finish with waterproof tape (not included). Do not use liquid sealants of any kind. Note ³ Not compatible with standard High Voltage C dimming controls. SUMITTL FORM JO / PROJECT NME JO TYPE SPECIFIER NME CONTCT PHONE CONTCT EMIL DTE JO LOCTION CTLOG NUMER OTHER 1 OF 2
SPHERE-STR LED WLL WSHER W 7.88 in. SPECIFICTION SHEET H 9.21 in. (w/ bracket) H 6.69 in. SPHERE-STR RG FIXTURE Luminous Intensity Distribution W 8.35 in. (w/ bracket) Illuminance at Distance -/+180 Flux out:389.8 lm -150 150 3.281ft 1m 1506,2193fc 16211,23604lx 0.5695ft 17.36cm -120 120 6.562ft 2m 376.5,548.2fc 4053,5901lx 1.139ft 34.72cm -90 0 90 5000 9.843ft 3m 167.3,243.7fc 1801,2623lx 1.708ft 52.07cm 10000-60 15000 60 13.12ft 4m 94.13,137.1fc 1013,1475lx 2.278ft 69.43cm 20000-30 25000 30 0 VERGE EM NGLE(50%):10.1 DEG UOM:Candela V 0.0DEG PLN,10.0deg H 0.0DEG PLN,10.3deg 16.4ft 5m 60.24,87.72fc 648.4,944.2lx 2.847ft 86.79cm Height Eavg,Emax ngle:9.92deg Diameter Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. Safety & Warnings Turn power OFF at main breaker before servicing or installing this product. This product is intended to be installed and serviced by a qualified, licensed electrician. Install in accordance with the National Electric Code and local regulations. Install in a well-ventilated, combustion-free environment. Do not disassemble or modify this product. Doing so will void your warranty. This fixture is not compatible with any traditional dimming controls. Wall washers can only be controlled/dimmed with the on-board interface or with an external DMX controller. Please contact customer service for additional information. Ensure all adjusting screws on mounting brackets and fixtures are properly secured prior to permanent installation. When mounting to walls and ceilings, use applicable lag bolts and consider the strength of these surfaces versus the weight of the fixture. It is recommended to power this fixture by a GFCI protected circuit. This fixture is IP65 rated. ttached wet-location 3-pin M14 connections are IP67 rated. When installing outdoors or in a wet location, ensure water-resistant end caps are connected to all exposed wet location 3-pin M14 connections. If attaching XLR-3 adapter cables seal all XLR-3 DMX connections with 1.25 wide heat shrink and finish with waterproof tape (not included). Do not use liquid sealants of any kind. This fixture is only UL Listed for connection with a 120VC, 15- or 20-ampere branch circuit. This fixture is not to be used in or around chlorinated, treated, or salt water due to the corrosive and degrading qualities of chlorine, saline, and other chemicals on the fixture components. Keep at least 16 feet away from pools and spas. This fixture is rated for use in an environment where the ambient operating temperature is -4 ~ 104 F (-20 ~ 40 C). 2 OF 2
WET LOCTION WLL WSHERS INSTLLTION SHEET Safety & Warnings efore you begin, read all warnings and installation instructions thoroughly. Turn power OFF at main breaker before servicing or installing this product. This product is intended to be installed and serviced by a qualified, licensed electrician. Install in accordance with the National Electric Code, and local regulations. Install in a well-ventilated, combustion-free environment. Do not disassemble or modify this product. Doing so will void your warranty. This fixture is not compatible with any traditional dimming controls. Wall washers can only be controlled/dimmed with the on-board interface or with an external DMX controller. Please contact customer service for additional information. Ensure all adjusting screws on mounting brackets and fixtures are properly secured prior to permanent installation. When mounting to walls and ceilings, use applicable lag bolts and consider the strength of these surfaces versus the weight of the fixture. When installing outdoors or in a wet location, ensure water-resistant end caps are connected to all exposed wet location 3-pin M14 connections. If attaching XLR-3 adapter cables seal all XLR-3 DMX connections with 1.25 wide heat shrink and finish with waterproof tape (not included). Do not use liquid sealants of any kind. This fixture is IP65 rated. ttached wet-location 3-pin M14 connections are IP67 rated. It is recommended to power this fixture with a GFCI protected circuit. This fixture is only UL Listed for connection with a 120VC, 15- or 20-ampere branch circuit. This fixture is not to be used in or around chlorinated, treated or salt water due to the corrosive and degrading qualities of chlorine, saline, and other chemicals on the fixture components. Keep at least 16 feet away from pools and spas. This fixture is rated for use in an environment where the ambient operating temperature is -4 ~ 104 F (-20 ~ 40 C). Mounting RODWVE Wall Washer 3/8 mounting holes SPLSHLIGHT Wall Washer 3/8 mounting holes SPHERE-STR Wall Washer 1/2 mounting holes Ensure fixture is properly mounted and all adjusting screws are properly secured prior to permanent installation. ll fixtures must be individually powered by 120VC. Waterproofing XLR-3 Connections When installing outdoors or in a wet location, ensure water-resistant end caps are connected to all wet location 3-pin M14 connections. If attaching XLR-3 DMX adapter cables seal all XLR-3 connections with 1.25 wide heat shrink and finish waterproof tape (not included). Do not use liquid sealants of any kind. Step 1. Step 2. 212º F (100º C) Use a heat gun with a minimum heating temperature of 212 F (100 C) when shrinking tube. Heat the shrink tube evenly Finish with Waterproof Tape Operation Overview Wall Washers can be operated in two ways: 1) Independently (One or more fixtures): Primary fixture operating independently or commanding additional fixtures. 2) With a DMX Controller: One or more wall washers commanded by a DMX controller. 1 OF 3
WET LOCTION WLL WSHERS INSTLLTION SHEET Operation Overview (continued) Each wall washer has its own on-board control pad and 3-digit display, operated by two menu button controls and. utton cycles through the 3-digit display and switches the display from the ddress Menu (Fig. 1a) to the Function (P) Menu (Fig. 1b). Pressing utton continually changes the desired value of each field. t startup, the wall washer will always be set in the ddress Menu. To switch to the Function (P) Menu (Fig. 1b), press utton once and Field 3 will begin to flash. Press utton three times to be directed to the Function (P) Menu. Once in the Function (P) Menu, press utton two times to switch back to the ddress Menu. ddress Menu Fig. 1a Function (P) Menu Fig. 1b Field 1 Field 2 Field 3 Field 1 Field 2 Field 3 P 6 Independent Setup: (Primary fixture operating independently or commanding additional fixtures) 1. Link each wall washer together with the attached male and female 3-pin M14 connetions (maximum run: 10 fixtures). Power up each wall washer by inserting the C cord into a standard 120VC electrical receptacle (Fig. 2a). 2. Once powered, the on-board control pad of each wall washer will automatically set to the ddress Menu. Choose the preferred fixture to operate as the master controller (this can be any fixture in the series) and set the code in the ddress Menu of the master fixture to the default address 001. Do so by setting Fields 1 & 2 to 0 and Field 3 to 1. 3. In the master wall washer Function (P) Menu (Fig. 2a), set the desired command for all master & slave fixtures to perform in Fields 2 & 3. Once selected, wait 10 seconds for the selected field to stop flashing and the selected command will be set 4. To sync the slave washers to the master washer, set the code in the ddress Menu of each slave fixture to any number other than 001 (Fig. 2b). It is recommended to set each slave with an individual code (e.g. 002, 003, 004 etc.). The Function (P) Menu is not required to operate slave wall washers. Master Wall Washer Slave Wall Washer P63 002 0 0 1 Fig. 2a Fig. 2b DMX Controller Setup: (One or more wall washers commanded by a DMX controller) Please note that all DMX control systems operate differently and may require additional technical knowledge of the DMX controller and equipment to operate the wall washers effectively. It is recommended that only experienced technicians install DMX control systems. 1. ttach the included XLR-3 adapter cable between the DMX controller and wall washer 3-pin M14 connection (Fig. 3) (not all DMX controllers have XLR-3 connections). 2. Link each additional wall washer together with the attached male and female mini 3-pin cables (maximum run: 10 fixtures). 3. Power each fixture by inserting the C cord into a standard 120VC electrical receptacle. 4. Once powered, the on-board control pad of each wall washer will automatically set to the ddress Menu. To effectively command the fixtures with the DMX control, match the value of each addressing field with the 3-channel address code commanded from the DMX controller. DMX Controller with 3-pin XLR Plugs Fig. 3 2 OF 3
WET LOCTION WLL WSHERS INSTLLTION SHEET Command Setting Charts RG Wall Washer Command Setting Chart Number Field 1 Number Field 2 Number Field 3 P 1- Static Red 1-9 rightness Control P 2- Static Green 1-9 rightness Control P 3- Static Yellow 1-9 rightness Control P 4- Static lue 1-9 rightness Control P 5- Static Purple 1-9 rightness Control P 6- Static Cyan 1-9 rightness Control P 7- Static White 1-9 rightness Control P 8- ll Color Jump - Warm to Cool 1-9 Speed Control P 9- ll Color Fade - Warm to Cool 1-9 Speed Control P - Random Color Fade 1-9 Speed Control P - Random Color Flashing 1-9 Speed Control P C- Cycle ll Modes 1-9 Speed Control White Wall Washer Command Setting Chart Number Field 1 Number Field 2 Number Field 3 P 1- Sustain Light Option 1 1-9 rightness Control P 2- Sustain Light Option 2 1-9 rightness Control P 3- Sustain Light Option 3 1-9 rightness Control P 4- Sustain Light Option 4 1-9 rightness Control P 5- Sustain Light Option 5 1-9 rightness Control P 6- Sustain Light Option 6 1-9 rightness Control P 7- Sustain Light Option 7 1-9 rightness Control P 8- Random Light Jump 1-9 Speed Control P 9- Pulse Fade 1 1-9 Speed Control P - Pulse Fade 2 1-9 Speed Control P - Random Strobe 1-9 Speed Control P C- Cycle ll Modes 1-9 Speed Control For additional technical information, please refer to the product specification sheet or contact customer service. V 1.2 3 OF 3