ADDENDUM to the August 2012 Urban Design Brief

Similar documents
URBAN DESIGN BRIEF REPORT

Urban Design Brief December 23, 2015 Southside Construction Group Official Plan & Zoning By-Law Amendment

URBAN DESIGN BRIEF NORTHVIEW FUNERAL HOME HIGHBURY AVE N, LONDON, ON

Urban Design Brief 1576 Richmond Street City of London

Urban Design Brief. 583, 585 and 589 OXFORD STREET EAST. Salt Clinic Canada Inc.

Urban Design Brief Fanshawe Park Road. Competition Toyota

URBAN DESIGN BRIEF. April FREEPORT Street TOWNHOUSES. 711 FREEPORT St., LONDON

URBAN DESIGN BRIEF.. on behalf of the owner..sunningdale Commercial Inc.

LIST OF FIGURES APPENDIX. Urban Design Brief: Proposed Townhouse Development, 299 Tartan Drive (City of London ON)

Urban Design Brief. 875 Wellington Road. Proposed One-Storey Fast Food Restaurant and Two-Storey Restaurant. Wellington Harlech Centre Inc.

URBAN DESIGN BRIEF URBAN DESIGN BRIEF 721 FRANKLIN BLVD, CAMBRIDGE August 2018

Urban Design Brief to 1557 Gordon Street & 34 Lowes Road West

Bel-Air Lexus Automobile Service Station

URBAN DESIGN BRIEF 305, 309, & 315 SOUTHDALE ROAD WEST LONDON ONTARIO

URBAN DESIGN BRIEF. 2136&2148 Trafalgar Road. Town of Oakville

Urban Design Brief Woodland Cemetery Funeral Home 493 Springbank Drive

Tel: (705) Fax: (705)

MIDTOWN MIXED-USE VILLAGE. TECHNICAL DATA SHEET COMPONENT C-1 FOR PUBLIC HEARING - PETITION NUMBER Project No RZ1.1. Issued.

URBAN DESIGN BRIEF 181 Burloak Drive, Oakville

Urban Design Manual 2.0 DRIVE-THROUGH FACILITIES. Background. Urban Design Challenges

CHAIR AND MEMBERS PLANNING & ENVIRONMENT COMMITTEE GEORGE KOTSIFAS MANAGING DIRECTOR, DEVELOPMENT & COMPLIANCE SERVICES & CHIEF BUILDING OFFICIAL

393, 395, 397, 399, 401 and 403 Spring Garden Avenue Official Plan and Zoning By-law Amendment Application Preliminary Report

240 and 242 Finch Avenue West Zoning By-law Amendment Application Preliminary Report

Design Guidelines for Residential Subdivisions

URBAN DESIGN BRIEF 1435 Beaverbrook Road On behalf of Wonderland Commercial Centre Inc.

Regency Developments. Urban Design Brief. Holyrood DC2 Rezoning

Request for Decision. Recommendation. Presented: Monday, Jul 07, Report Date Friday, Jun 20, Type: Public Hearings

New-Cast Mixed-use Development Proposal King Street West, Newcastle, Ontario

CITY OF VAUGHAN EXTRACT FROM COUNCIL MEETING MINUTES OF MAY 27, 2014

*** DRAFT 2 FOR PUBLIC REVIEW ***

4. INDUSTRIAL 53 CASTLE ROCK DESIGN

4. DOWNTOWN AND COMMERCIAL LAND USE DESIGNATIONS

4.0 Design Guidelines For The Village Centre. South fields Community Architectural Design Guidelines Town of Caledon

Clairtrell Area Context Plan

1. General Purpose. 3. Uses

DRAFT Northeast Quadrant of Kipling Avenue and Highway 7 DRAFT AUGUST 29, Goals Land Use. The goals of this Plan are to:

lot flankage Y street 16m 6m landscape strip for large site 3m landscape strip for small medium site

(DC1) Direct Development Control Provision DC1 Area 4

Urban Design Brief. Garden Drive Townhouse Development Matas Development Group. Oakville, Ontario

3686 and 3688 St Clair Avene East Zoning Application Final Report

Urban Design Brief. Watson Parkway North & Watson Road North Guelph, Ontario. Prepared by Coletara Development

Commercial Development Proposal Tenth Line Road. Planning Rationale Report. Minto Developments Inc.

BUILDING SCALE AND SETBACKS 5 ELEMENTS:... 5 FAÇADES (COMMERCIAL/RESIDENTIAL) 5

TABLE OF CONTENTS 1.0 INTRODUCTION... 3

MEMORANDUM. This memo deals with proposed amendments to previously issued Development Permit No for Park Royal North.

Wide asphalt driveway abutting school property. garage built with incompatible materials, too close to park. incompatible fencing materials

Harmony Technology Park Third Filing, Second Replat Custom Blending, Project Development Plan/Final Development Plan - FDP #130021

EXHIBIT A. Chapter 2.7 SPECIAL PLANNED DISTRICTS. Article XVIII 15th Street School Master Planned Development

ELMVALE ACRES SHOPPING CENTRE MASTER PLAN

GUIDELINES REPLACEMENT HOUSING GUIDELINES LOCATION INTRODUCTION URBAN DESIGN GUIDELINES

Housing and Coach House Guidelines - Ladner

URBAN DESIGN BRIEF New Street Burlington, ON

Bylaw A Bylaw to amend Bylaw 12800, as amended, The Edmonton Zoning Bylaw Amendment No. 2239

Complete Neighbourhood Guidelines Review Tool

AMENDMENT NO. 42 TO THE OFFICIAL PLAN OF THE TOWN OF GRIMSBY

appendix and street interface guidelines

URBAN DESIGN BRIEF. on behalf of the owner 1331 Hyde Park Road Inc.

Gateway commercial MIXED USE MASTER SITE PLAN. CITILAND AIrDRIE GATEWAY VENTURE INC. airdrie GATEWAY COMMERCE CENTRE. airdrie, ALBERTA FEBRUARY 2012

11.4 Highway 400 North Employment Lands Secondary Plan APPROVED BY THE ONTARIO MUNICIPAL BOARD ON NOVEMBER 21, 2011

From: Director, Community Planning, Scarborough District. Ward 40 Scarborough-Agincourt

URBAN DESIGN BRIEF. Saginaw Subdivision 124 SAGINAW PARKWAY, CAMBRIDGE OCTOBER 2015 OUR FILE 1422A

Sierra Springs Regional Commercial Master Site Plan Airdrie, Alberta Hopewell Development Corporation Project No May 26, 2010

HALF MOON BAY CATHOLIC ELEMENTARY SCHOOL SITE PLAN CONTROL DESIGN BRIEF

Design Brief for Proposed Mixed-Use Medical / Office Building

Urban Design Review Panel Submission. The Ottawa Train Yards - Office Development. 405 Terminal Avenue. 17 April Table of Contents.

5.1 Commercial and Industrial Development. (Effective April 1, 2006)

AIRPORT BUSINESS PARK

BENSON / HUNT TERTIARY PLAN

Multi family Residential Development Permit Area

REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT

Policies and Code Intent Sections Related to Town Center

6.0 Land Use Policies for Rural Settlements. 6.1 Rural Settlement Strategy

10 COPE DRIVE. May 08, 2018 Planning Rationale and Design Brief. Site Plan Control

14 October 10, 2012 Public Hearing APPLICANT: MPB, INC

SDOT DPD. SDOT Director s Rule DPD Director s Rule DCLU DR SED DR of 7 CITY OF SEATTLE

3.13. Development Guidelines

599 Kennedy Road - Official Plan Amendment and Zoning Amendment Application - Preliminary Report

MULTIFAMILY RESIDENTIAL DESIGN PRINCIPLES Site Plan and Design Review Principles Checklist

11.4 Highway 400 North Employment Lands Secondary Plan

MIXED-USE ZONING DISTRICT DESIGN GUIDELINES

Urban Design Brief. 58 Sunningdale Road West City of London. Barvest Realty Inc.

LAND USE ASSESSMENT REPORT (LUAR) PROPOSED AFFORDABLE HOUSING COMPLEX MAIN ROAD PDE FILE NUMBER: REZ

5.1 Site Plan Guidelines

Corridor Transformation Strategy

PLANNING RATIONALE FOR THE PROPOSED RIVERSIDE SOUTH ELEMENTARY SCHOOL 715 BRIAN GOOD AVENUE, OTTAWA, ON

Article 7.05 Manufactured Home Park Districts

KEY MAP DEVELOPMENT PERMIT AREA MAP. Sunnymede North Sub-Area Plan

280 Manse Road - Official Plan Amendment, Zoning Amendment, Draft Plan of Subdivision Applications - Preliminary Report

340, 352 AND 360 RIVER ROAD, CAMBRIDGE, ONTARIO

TRAFALGAR ROAD

Royal Thai Embassy Ottawa. Major Zoning Amendment Proposal for 180 Island Park Drive. Planning Rationale

Table of Contents. Elm Avenue Improvement Plan City of Waco, Texas. Introduction 1. Existing Context 1 Figure 1 2.

CHAPTER 3. Design Standards for Business, Commercial, Industrial, Recreational and Institutional Uses

Chapter PEDESTRIAN COMMERCIAL (PC) ZONING DISTRICT

2.5 Roads. Loading and service areas adjacent to Highway 401 should be screened through architectural walls and/or landscape buffer planting.

New Street Proposed Redevelopment Architecture & Urban Design Brief

From Sarasota County Optional Commercial Redevelopment Regulations. a. Intent.

VILLAGES AT RIVERDALE

FRUITVALE TRANSIT VILLAGE (Phase 2) Residential Project

URBAN DESIGN BRIEF Audi London 481 Wharncliffe Road South, London, Ontario. October, 2013

Transcription:

NIXON MEDICAL CLINIC at 510,518, and 526 Southdale Road East at Nixon Avenue, City of London. APRIL 201 ADDENDUM to the August 2012 Urban Design Brief Prepared by: Endri Poletti. Architect Kirkness Consulting Inc., Urban and Rural Planning

ADDENDUM TABLE OF CONTENTS PART ONE DESIGN PRINCIPLES 1. Subject Lands, 2. Proposal. Design Goals & Objectives PART TWO DESIGN RESPONSE Contemporary design Corner location Building elements and materials Pedestrian access and linkages Vehicular access and parking Adherence to section 11 of the Official Plan Landscape Design Sustainability PART THREE PLANS AND DRAWINGS 1. Site Plan 2. Architectural Elevations. Architectural Perspectives

ADDENDUM Urban Design Brief Part One DESIGN PRINCIPLES Background and Context: This report is an ADDENDUM to the original Urban Design Brief (UDB) of August 12, 2012. The original UDB was reviewed by both the City Planning Staff and the Urban Design review Panel in September of 2012 and comments were provided as part of the rezoning application process. At the City Staff s suggestion, only a small part of Part 1 is included in the addendum, that being Section 1, which is the same as in the original Brief, and section 2, which is the PROPOSAL. The Proposal has changed. This requires to revisions to the Brief. It also requires the revisions to be presented to the Urban Design Review Panel. The proponents have changed as well. Dr. A Mohammed remains the owner of the three subject properties. A partner has been added, who is Peter Grigoris, and who has had business experience in developing and building medical clinics. These two principles are forming a new partnership company which will develop the site into a larger and more viable medical clinic the NIXON MEDICAL CLINIC. 1. Subject Lands, Proposal & Surrounding Land Uses Subject Lands -- The subject lands consist of properties, municipally addressed as 510, 518, and 526 Southdale Road East. The cumulative frontage of the three properties along Southdale Road East is approximately 89.m. Their total area is approximately 56m 2. There is no significant vegetation presently on the subject lands. 510 Southdale contains a converted single detached residential dwelling used for Dr. Mohammed s existing pediatric medical practice, while 518 and 526 Southdale Road East each contain a single detached dwelling still used for residential purposes. The subject lands are located at the intersection of a major arterial (Southdale Road East) and primary collector (Nixon Avenue). Southdale Road East along the subject lands has an average annual daily traffic (AADT) count of 2000 vehicles, and Nixon Avenue has an AADT of 11,000 vehicles per day. These dwellings would be removed to create Dr. Mohammed's and assembled property for a new medical office and ancillary pharmacy. This project would contribute to the land use intensity characteristic of an existing neighbourhood commercial node originating at the intersection of Nixon Ave. and Southdale Road East. Figure 1 shows the location of the subject lands and neighbouring land uses. 1

Figure 1 Location Plan showing the three properties assembled. building about 12 m in height as far away from them as possible notwithstanding that three storeys could remain compatible interfacing low density residential development. Full turning vehicular access would be provided from Nixon Avenue, and a right in- right out access is proposed at the easterly property edge to Southdale Road East. Further details of the architecture and site design of the proposed development are provided in Section Two of this Brief, and the actual concept plans are provided in Section Three. The DESIGN PRINCIPLES derived from the original Brief s analysis and policy review and now updated are as follows: Proposal -- The proposed redevelopment of the subject lands would ultimately create one new building and remove the three existing buildings on the assembled site. The new building would comprise a gross floor area of 2262 m 2 (24,49 ft 2 ), and be three storeys approximately 12 m -- in height. Each floor would be of 754 m2. The proposed new building would be placed at close to the major intersection for two reasons: 1. Respect Urban Design principles and design guidelines, and; 2. Respecting the existing low density residential development north and east of the site, by locating the three storey 1. The Building is be close to the streets intersection; 2. Parking is to be in the rear yard and made as inconspicuous as possible from the public streets and adjacent residential land uses;. The main vehicular access will remain onto Nixon Avenue, and a restricted turns access is proposed onto Southdale Road East; 4. Maintaining privacy for the abutting northerly and easterly residential neighbours is to be provided and this will be achieved through fencing and 2

ornamental landscape treatment around the perimeter of the site. 5. Low rise built form of storeys will be compatible with surrounding built form given appropriate separation distances; 6. The corner location should be celebrated with built form at the corner intersection. Urban Design Brief Part Two DESIGN RESPONSE The description of the new proposal is illustrated in Part Three, and as follows; Site area 56 m2 Building area -ground floor 754 m2 Lot coverage 1.4% Building Height storeys 11.5 m Total building area 2212 m2 Landscape Open Space coverage 27.4 % Parking spaces 105 spaces Vehicular accesses - 2 Section 11.1.1 of the Official Plan outlines the Urban Design Principles for development within the City of London. Many of these principles were implemented in the proposed design to improve the use of the subject lands, compliment the Southdale Road streetscape and enhance the Nixon Avenue gateway. The site design recognizes the importance of the south west corner and has designed a three storey building to be set at the intersection. The overall design of the development is contemporary 21 st century design with: A clean cubical massed building set at the very corner of the intersection; Exterior building materials comprise a mixture of smooth stucco and panel surfaces integrated with brick and rock face stone, providing contrast and variation softening the possible harshness of the contemporary design; The clear anodized window frames with frosted glazing will enhance the contemporary designs and allowing for the privacy of the operation of the medical building; Vertical and horizontal wall panel elements are incorporated to provide interest, uniqueness and idenity; Special lighting would be provided to accent the building architecture and site design at night.

Signage would be integrated into the design of the building -- wall mounted walls wash lighting from within the landscaping. Pedestrian Access to the site would be ample and focused at three locations, being from: a) The intersection of Nixon road and Southdale Road, where a public transit stop is located, b) The east extremity along Southdale Road East, c) The north extremity along Nixon Avenue. Access to the building itself, public sidewalks along both Streets would connect site walkways to the buildings and parking area, as shown on the site plan. Landscape wall features along Southdale Road helps enforce the walkways into the development and to get to public transit along Southdale and Nixon Roads. Vehicular access would be from Nixon Rd and Southdale Road East, connect to a parking area of 105 spaces, including handicapped spaces. The parking area would be well screened with landscaping from adjacent roads. Section 11.1.1 (iv) describes how emphasis will be placed on the promotion of a high standard of design for buildings to be constructed in strategic or prominent locations. The proposed building design comprises a high level of architectural design with distinctive harmonious building elements. The building would enhance the gateway entrance to both the White Oaks Community to the south and the Highland Community to the north. As stated in Section 11.1.1 (xxi) gateways are important elements in the creation of a sense of place and arrival and occupy strategic and prominent locations, and are primarily associated with the major entrances to the city, districts or to neighborhoods. The placement and architecture of buildings themselves can frame or create the gateway or entrance. Section 11.1.1 (v) states, the massing and conceptual design of new development should provide for continuity and harmony in architectural style with adjacent uses. The new building will be recognized as a different, but well-designed attractive building to compliment the residential area to the north and the commercial cluster to the south. The streetscape along both major streets will be improved as per Section 11.1.1 (vii) stating that it supports a coordinated approach to the planning and design of streetscape improvements. As noted previously, the existing homes on the subject properties is in a state of minimal standard. Redevelopment of these lands is supported by Section 11.1.1. (vi) Which encourages the relocation 4

or replacement of incompatible land uses and the redevelopment of derelict properties. In this case, the properties are also underutilized with very large old veteran land act lots that have small older homes.. The site plan shows that the subject properties can accommodate the proposed buildings and parking, while also allowing for required road widening allowances along Southdale and Nixon Roads. The building position has been moved to the front intersection corner of the assembled property and parking has been placed to the rear and side. This arrangement of built form provides streetscape an anchoring of the corner location and some road noise attenuation, for residents along the north side of Southdale road - pursuant to section 11.1.1 (xviii). Parking to the rear and side is based on City design standards, supporting subsection xiii of the Urban Design Guidelines which looks to facilitate maneuverability on site., and to reduce the traffic flow disruption resulting from turning movements to and from the property Landscape design of the site will be both ornamental and functionally screening. The former will be around the building across its front and flankage, as well within a hard surfaced context to facilitate pedestrian movement and access. The latter will be along Southdale to screen parking areas, and especially along the north and east property boundaries with planning and privacy fencing, to achieve aesthetic compatibility with the abutting residential neighbourhood. Sustainability measures will be specifically in the more detailed design of the project. A number of environmental and sustainability measures are being considered for the proposed development. The most feasible measures include: water efficient landscaping; reduce energy requirements through efficient building systems; use high-efficiency glazing; utilize recycled content in building materials (re-claimed brick); use regional materials and services; use rapidly renewable materials; use low V.O.C. emitting materials; utilize natural ventilation; exceed required indoor air quality performance; and incorporate passive design elements to decrease heating and cooling requirements. 5

Urban Design Brief Part Three PLANS AND DRAWINGS The following presents the: 1. Site plan 2. Renderings. Architectural elevations. 6

AREA OF WORK ITEM NO. DATE: (m/d/y) ISSUED FOR: BY: EXTENT OF FENCE PROPERTY LINE N8*21'25"E 8967 EXISTING TREE EXISTING TREE EXISTING TREES EXISTING TREES 1500 R 6000 4 KEY PLAN A101 CODE ANALYSIS ONTARIO BUILDING CODE PART MAJOR OCCUPANCY: GROUP D - MEDICAL OFFICES BUILDING AREA: (m²) EXIST: NEW: 75.88 sq m. GROSS AREA: (m²) EXIST: NEW: 2212.14 sq m. NO. OF STOREYS: BUILDING HEIGHT: NO. OF STREETS: BUILDING CLASSIFICATION: SPRINKLER SYSTEM PROPOSED: STANDPIPE REQ'D: FIRE ALARM REQ'D: WATER SERVICE /SUPPLY ADEQUATE: HIGH BUILDING PERMITTED CONSTRUCTION: ACTUAL CONSTRUCTION: MEZZ. AREA: (m²) OCCUPANT LOAD: SPATIAL SEPARATION Scale: 1 : 2 ABOVE GRADE: BELOW GRADE: 0 11.40 m. 2 GROUP D UP TO STOREYS NOT REQUIRED ENTIRE BUILDING BASEMENT ONLY IN LIEU OF ROOF RATING SPECIFIC LOCATION ONLY - NEW ADDITION ONLY COMBUSTIBLE & NON-COMBUSTIBLE NON-COMBUSTIBLE 0 - NOT APPLICABLE PLUMBING FACILITIES: DESIGN OF BUILDING FIXTURES 1/14M2 FEMALE MALE FIRST FLOOR 54 = 27 / SEX FIRST FLOOR 54 = 27 / SEX SECOND FLOOR 54 = 27 / SEX BARRIER FREE DESIGN: REQUIRED (FRR): FIRE RESISTANCE RATING RATING (FRR): FRR HORIZONTAL ASSEMBLIES LISTED DESIGN NO. FLOORS 0.0 HR ROOF 0.0 HR MEZZANINE 0.0 HR FRR SUPPORTING MEMBERS LISTED DESIGN NO. COLUMNS 0.0 HR ARCHES 0.0 HR LOAD BEARING WALLS 0.0 HR NO NO NO NO (BASED ON 9. M2/PERSON) 75.88/9. = 81 PERSON / FLOOR FLOORS = 24 EXTERIOR WALL CONSTRUCTION TOTAL: 75.88 sq m. TOTAL: 2212.14 sq m. SECTION.1.2.1 1.1..2 1.1..2.2.1.1.2.1.1.2.2.10 &.2.5.5.2.2.5.2.2.5.2.2.2.1.5.2.2.17.2.9.2.4.1(e).2.5.7.2.6.2.2.5.2.2.5.1.17.1.7.4.7.4.7.8.2.2.5.2.2.5.2..1 EXISTING BUS STOP EXISTING TREE R 6000 EX. HP PROPERTY LINE N10*04'50"W 609 EXIST. CITY SIDEWALK 7000 8146 ULTIMATE ROAD WIDENING ALLOWANCE R 000 8252 R 000 2995 7024 6000 X 6000 CST 9214 1976 41 7256 CONC. CURB ASPHALT PARKING AND DRIVEWAY SURFACE 1 CONC. SIDEWALK 1800 FENCE HIGH WOOD BOARD TO CITY STANDARDS 40 (TYP) (TYP) 21 CONC. SIDEWALK 5500 5500 6199 PROPOSED FACILITY STOREY 2212.14 M2 TOTAL GROSS AREA 75.88 M2 PER FLOOR MAIN B.F. ENTRANCE & FIRE MAN ENTRANCE EXIT 1200 POURED CONCRETE CURB C/W PLANTER BED CONC. CURB 195 ASPHALT PARKING AND DRIVEWAY SURFACE 1500 9214 200 2664 2080 2654 9 5500 6706 89 CONC. CURB 8 BICYCLE SPACES R 1500 88 ASPHALT PARKING AND DRIVEWAY SURFACE 2700 105 2700 94 99 ULTIMATE ROAD WIDENING ALLOWANCE 5500 679 5500 5500 7216 5500 5500 6500 5500 47077 7942 MASONRY GARBAGE ENCLOSURE 20 100 80 EXISTING TREE 65 ASPHALT PARKING AND DRIVEWAY SURFACE 66 1800 FENCE HIGH WOOD BOARD TO CITY STANDARDS 7000 CONC. CURB POURED CONCRETE CURB C/W PLANTER BED POURED CONCRETE CURB C/W PLANTER BED 1589 7000 79 5500 EXISTING TREE PROPERTY LINE N9*47'15"W 607 EXTENT OF FENCE IT IS THE RESPONSIBILITY OF THE OWNER, GENERAL AND/OR TENANT CONTRACTOR AND ALL SUB-TRADES TO BE FAMILIAR WITH THE PROJECT AS A WHOLE. ALL DISCREPANCIES AND DIMENSIONAL ERRORS ON THE PLANS AND RELATED DOCUMENTS MUST BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCING ANY WORK DO NOT SCALE DRAWING CONSTRUCTION SET HAVE ORIGINAL CONSULTANTS STAMP AND SIGNATURE THE CONTENTS OF THIS DRAWING REMAIN THE COPYRIGHT PROPERTY OF ENDRI POLETTI ARCHITECT INC. ENDRI POLETTI ARCHITECT INC. 55 OXFORD STREET EAST LONDON, ON, N6A 1V6 [519] - 850-9408 WALLS AREA OF EBF (m²) LD (m) L/H or H/L PERMITTED MAX. % OF OPENINGS PROPOSED % OF OPENINGS NORTH 248.8.6 2.99/1 100% 4.9% EAST SOUTH 159.9 248.8 WEST 159.9 47.0 2.5 17. 1.92/1 2.99/1 100% 100% 57.8% 8.0% 1.92/1 100% 54.70% FRR (HOURS) LISTED DESIGN OR DECRIPTION COMB. CONC. COMB. / NON-COMB. CONC. NON-COMB. CONC. FRS EX. HP 1450 EXIST. CITY SIDEWALK EXISTING BUS STOP OHW FRS PROPERTY LINE N8*19'55"E 8908 048 EX. HP FRS EASEMENT R 8000 OHW R 8000 NIXON MEDICAL O.B.C. MATRIX PART A101 Scale: 1 : 1 REFERENCES: CITY OF LONDON ONTARIO ZONING ORDINANCE EXIST / ZONE REQUIRED PROPOSED N FIRE ROUTE SOUTHDALE ROAD EAST SHEET TITLE: SOUTHDALE ROAD, LONDON ONT. GENERAL ZONING DISTRICT CLASSIFICATION LAND USE LOT AREA LOT DEPTH R-2 / OC5 800 M2 Minimum RO2 56.28 M2 89.60 m. 1 SITE PLAN A007 A101 Scale: 1 : 200 SITE PLAN SITE DEVELOPMENT DATA O.B.C. MATRIX KEY PLAN LOT FRONTAGE 20 m. Minimum 6.09 m. LOT COVERAGE 0% 1.8% LANDSCAPE OPEN SPACE 0% 27.% BUILDING FOOTPRINT 75.88 M2 BUILDING HEIGHT 12.0 m. 11.40 m. FIRST ISSUE DATE: 0/05/1 BUILDING SETBACK NORTH BOUNDARY 4.8 m. 1.95 m. DRAWN BY: JA C:\Users\john\Documents\124-Nixon Medical_Central File_john.rvt FILE PATH: SOUTH BOUNDARY EAST BOUNDARY WEST BOUNDARY PARKING SPACES 2nd & th FLOORS MEDICAL STANDARD : 1/15 m2 (1808 m2) BARRIER-FREE BICYCLE : 7% OF PROVIDED PARKING 9.0 m. 4.8 m. 7.0 m. 1st FLOOR MEDICAL SUPPORT : 1/25 m2 (59.14 m2) 22 10 TOTAL CAR PARKING 12 11 2 SITE DEVELOPMENT DATA A101 Scale: 1 : 1 121 9.0 m. 47.07 m. 7.0 m. 92 8 C:\Users\john\Documents\124-Nixon Medical_Central File_john.rvt FILE PATH: 4/4/201 9:58:09 AM PLOT DATE / TIME: PROJ. MGR/ARCH: CHECKED BY: APROVED FOR CONSTRUCTION DATE: PROJECT NO. SHEET NO. EP EP - 124 A101

Endri Poletti ARCHITECT INC. DATE: DRAWN BY: PROJ. NO: DWG. NO: 55 OXFORD STREET EAST LONDON, ONTARIO N6A 1V6 519-850-9408 endri@poletti-architect.com NIXON MEDICAL D VIEWS SOUTHDALE ROAD, LONDON ONT. EAST VIEW WEST VIEW 04/0/201 EP 124 SK-111 \\SBSMAIN\RedirectedFolders\cassandra\My Documents\124-Nixon Medical_Central File_cassandra.rvt FILE PATH:

D VIEW - EAST VIEW NIXON MEDICAL SOUTHDALE ROAD, LONDON ONT.

ITEM NO. DATE: (m/d/y) ISSUED FOR: BY: 1 2 4 4 2 1 1 201/04/0 SITE PLAN SUBMISSION EP L5-T/O PRPT 11580 L5-T/O PRPT 11580 L4-T/S Roof 10980 L4-T/S Roof 10980 EFIS C/W REVEALS L-rd FLR 720 EFIS C/W REVEALS L-rd FLR 720 L2-2nd FLR 660 STONE VENEER L2-2nd FLR 660 STONE VENEER LIMESTONE BASE LIMESTONE BASE L1-1st FLR 0 L1-1st FLR 0 4 EAST ELEVATION A01 Scale: 1 : 100 1 WEST ELEVATION A01 Scale: 1 : 100 IT IS THE RESPONSIBILITY OF THE OWNER, GENERAL AND/OR TENANT CONTRACTOR AND ALL SUB-TRADES TO BE FAMILIAR WITH THE PROJECT AS A WHOLE. ALL DISCREPANCIES AND DIMENSIONAL ERRORS ON THE PLANS AND RELATED DOCUMENTS MUST BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCING ANY WORK DO NOT SCALE DRAWING E D C B A CONSTRUCTION SET HAVE ORIGINAL CONSULTANTS STAMP AND SIGNATURE L5-T/O PRPT 11580 THE CONTENTS OF THIS DRAWING REMAIN THE COPYRIGHT PROPERTY OF ENDRI POLETTI ARCHITECT INC. EFIS C/W REVEALS L4-T/S Roof 10980 L-rd FLR 720 ENDRI POLETTI ARCHITECT INC. 55 OXFORD STREET EAST LONDON, ON, N6A 1V6 [519] - 850-9408 STONE VENEER L2-2nd FLR 660 LIMESTONE BASE L1-1st FLR 0 5 D View - FRONT ENTRANCE A01 Scale: 2 NORTH ELEVATION A01 Scale: 1 : 100 NIXON MEDICAL A B C D E L5-T/O PRPT 11580 SOUTHDALE ROAD, LONDON ONT. L4-T/S Roof 10980 SHEET TITLE: ELEVATIONS CURTAIN WALL SYSTEM EFIS C/W REVEALS L-rd FLR 720 AUMINUM CANOPY STONE VENEER L2-2nd FLR 660 FIRST ISSUE DATE: DRAWN BY: 02/25/201 CT C:\Users\john\Documents\124-Nixon Medical_Central File_john.rvt FILE PATH: 6 D View - EAST SIDE A01 Scale: SOUTH ELEVATION A01 Scale: 1 : 100 LIMESTONE BASE L1-1st FLR 0 C:\Users\john\Documents\124-Nixon Medical_Central File_john.rvt FILE PATH: 4/4/201 9:58:21 AM PLOT DATE / TIME: PROJ. MGR/ARCH: CHECKED BY: APROVED FOR CONSTRUCTION DATE: PROJECT NO. SHEET NO. EP EP - 124 A01