Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Similar documents
Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Installation manual plugs and connectors QUICK-CONNECT (63 A)

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Operating Instruction

Flameproof Manual Call Points

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

INSTRUCTIONS AND WARRANTY

Instructions For Use ENG. LED Magnifier Lamp

3-way switching valve

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Operating Instructions UniTech Perfect

Explosion Proof Combination Signal db (A) / 5 Joule

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

FSW300 Series Flow Switch

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

STRIP CUT PAPER SHREDDER

Installation and operating instructions. DK energy storage and DK energy buffer

EHA Hoffmann International GmbH

INSTRUCTIONS AND WARRANTY

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

KETTLE WK 6330 ENGLISH

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Operator s manual. Battery charger C 48/ en / 03

INSTRUCTIONS AND WARRANTY

Operating instructions

INSTRUCTIONS AND WARRANTY

ELECTRIC ASH CAN Model: CVACASH500 Part No:

B INSTRUCTIONS FOR USE

INSTRUCTIONS AND WARRANTY

USE AND INSTALLATION HANDBOOK

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

INSTRUCTIONS AND WARRANTY

MANUAL Overflow sensor NVF-104/34-PF

AS 500. Instructions for Use. Version 1.0. December

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS AND WARRANTY

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

RHMP01 MULTI PURPOSE FAN

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Universal Gripper UG 16, UG 18. Operating Instructions

7 Fin Oil Filled Radiator

ELECTRIC STOVE HEATER Models: FS2213B

Contents. AFTER SALES SUPPORT CCW /

HR 601 C A AUS. ENGLISH Instructions for use Page 2

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTRUCTIONS AND WARRANTY

INSTALLATION GUIDE NZ AU C

SASE BULL 240C. Dust Collection System Manual

HAND MIXER HM5040 ENGLISH. Product code

INSTRUCTIONS AND WARRANTY

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

HKF 8180 Operating instructions

VADA - Rain2Main Automatic Rainwater Controller

SHORT WAVE INFRARED PANEL DRYER

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

INSTRUCTIONS AND WARRANTY

STAINLESS STEEL TOASTER

Model: 1100 Float-Controlled Condensate Trap, PN 25

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety.

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL

Operating instructions (translation) Stunning Device for Small Animals

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Operating instructions

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

INSTRUCTIONS AND WARRANTY

Instruction Manual Suppository Penetration Tester. Type PM 30

CORREX MP Anode with external voltage source. Installation & Operation Manual

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

INSTRUCTIONS AND WARRANTY MODEL NO. SFS-107. Salton Foot Spa

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Sandwich Press. Please read the manual fully before using the appliance and keep the manual safe for future reference.

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

Corning LSE 6L Digital Water Bath

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

PERSONAL 1500W CERAMIC HEATER Instruction Manual

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

INSTRUCTIONS AND WARRANTY

Transcription:

EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01

Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended use 5 3 General safety instructions 6 4 Packaging, transport and storage 7 4.1 Packaging 7 4.2 Transport 7 4.3 Storage 7 5 Design 8 6 Assembly and disassembly 9 6.1 Connecting a cable to a 16-A / 32-A surface mounting or panel mounting socket outlet or plug 9 6.2 Disconnecting a cable from a 16-A / 32-A surface mounting or panel mounting socket outlet or plug 12 7 Cleaning and care 14 8 Decommissioning and disposal 15 2 / 16

1 About this manual This manual describes the assembly and disassembly of plugs and sockets with screw connections of Bals Elektrotechnik GmbH & Co. KG is an integral part of the product and must be kept in safe custody during the product service life must be read carefully and understood before use and any work. 1.1 Structure of the warnings The following picture illustrates the structure of a sample warning. 1 Hazard-specific symbol 2 Signal word 3 Type and source of the hazard 4 Possible consequences of failing to comply 5 Procedure for avoiding hazards 3 / 16

1.2 Symbols used General warning of a hazardous area Warning dangerously high voltage Notice 1.3 Signal words used All warnings in this manual are clearly highlighted. The following signal words are used for warnings: DANGER WARNING CAUTION NOTICE Warns of dangers which will lead to serious injuries or to death if the instructions are not followed. Warns of dangers that may lead to serious injuries or to death and/or cause considerable damage to property if the instructions are not followed. Warns of dangers that may lead to reversible injuries and/or considerable damage to property if the instructions are not followed. Warns of dangers that may lead to operational disruptions and/or considerable damage to property. Damage to the environment, too, may occur if the instructions are not followed. 4 / 16

2 Intended use Plugs and sockets with screw connections are built for professional use. The installation and the fixed connection to the mains supply should be carried out only by trained and qualified experts. Any use going beyond the intended use is considered to be improper. The manufacturer is not liable for damages resulting from improper use. Any such risk shall be borne solely by the user. In case of unauthorised modifications or conversions, the CE conformity becomes null and void, and thus, also all claims for warranty. Modifications may lead to risks for life and limb as well as damage to the plugs and sockets or loads connected. Factory-fitted labels and markings on the plugs and sockets should not be removed, modified or blurred. Protect against foreign bodies and impact of weather The plugs and sockets meet either the protection degree IP44, IP54 or IP67 in accordance with DIN EN 60529 (VDE 0470-1), depending on the respective design. Each of these mean: Protection degree IP44: Protected against solid bodies with a diameter beyond 1.0 mm, e.g. a wire Protection against water sprayed from all sides Protection degree IP54: Protected against dust in damaging quantity Complete protection against contact Protection against water sprayed from all sides Protection degree IP67: Dust-proof Complete protection against contact Protection against temporary immersion 5 / 16

Environment The following operating temperatures apply for the safe operation of the product: Standard version Military version -25 C... +40 C -33 C... +49 C 3 General safety instructions Safe use is ensured only if this manual is followed completely. Before installation, commissioning or operation, read this manual thoroughly. The plugs and sockets must be installed, maintained and put into operation properly by qualified experts in accordance with the laws, ordinances and standards. Keep easily combustible and explosive materials away from the plugs and sockets. Handle the cables with care by always pulling at the plug and not the cable when unplugging, by preventing the cable from getting damaged mechanically, by keeping intense heat away. Never use faulty products or products with dirty, scratched or damage contacts. Keep the contacts on the product clean. Avoid tripping hazards. 6 / 16

4 4.1 4.2 4.3 Packaging, transport and storage Packaging Packaging materials are valuable raw materials and can be reused. The packaging materials should therefore be brought to an appropriate recycling facility. If this is not possible, dispose of the packaging materials according to the locally applicable regulations. Transport Check the delivery for completeness and integrity. If you identify transit damage or if the delivery is incomplete, notify your dealer or supplier immediately. Storage The product must be stored in clean condition and protected from dust and humidity. The original packaging is best suited for this purpose. 7 / 16

5 Design Based on an example, the following figure illustrates the main components of a surface mounting / panel mounting socket outlet or a plug with screw connections. 1 Housing 2 Use of plug/socket outlet with screw terminals for all types of copper conductor. 3 Folding cover Conductor cross-sections The following table displays the possible conductor cross-sections that can be connected to the 16-A/32-A variants: Design Possible conductor cross-section 16 A 1.5 mm 2... 4 mm 2 32 A 2.5 mm 2... 10 mm 2 Technical specifications The technical specifications of the surface mounting and panel mounting socket outlets or plugs depend on the design. You will find them in our catalogue or on our website http://www.bals.com. 8 / 16

6 Assembly and disassembly DANGER Danger to life by electrical voltage The supply cable may carry high electrical voltage that is fatal. Pay attention to the five safety rules of electricity: 1. De-energise 2. Secure the supply from being switched on again 3. Ensure the de-energised condition 4. Connect to earth and short circuit 5. Cover or cordon off adjacent live parts 6.1 Connecting a cable to a 16-A / 32-A surface mounting or panel mounting socket outlet or plug Proceed as follows: 1. Make sure that the cable is de-energised. 2. Strip the cable to the required length. 3. Remove the insulation from the individual conductors (16-A designs: 9 mm; 32-A designs: 12 mm). Twist the multi-strand copper conductors slightly by hand for flexible conductors. Conductor end sleeves are not necessary but may be used. ð For surface mounting socket outlets or surface mounting appliance inlets follow the explanation starting from point 4. ð For panel mounting socket outlets or panel mounting appliance inlets, follow the explanation starting from point 7. 4. Loosen the two housing screws in order to open the housing. 9 / 16

5. Fix the bottom part of the housing to the wall with the help of the fixing material suitable for the application. 6. Push the cable through the sealing plugs (4) into the housing. Open the sealing plugs only as far as necessary so that they can still get sealed. Generally, we recommend using a separate cable gland for the cable entry. 10 / 16

7. The terminals are open at the time of delivery. Guide the bare individual conductors into the opening (6) and tighten the screws (5) with a torque of at least 0.8 Nm. Take care to see that only the bare individual conductor (without insulation) is clamped. Pay attention to the marking of the terminals and ensure that the assignment of the individual conductors to the terminals is correct. 8. Check whether the individual conductors are seated tightly by pulling them lightly. If this is not the case, open the terminal and repeat the previous step. 9. For surface mounting socket outlets and plugs: Tighten the cable gland. 10. Fix the housing with the panel mounting appliance (panel mounting variant) or fix the cover with screws to the housing (surface mounting variants). NOTICE! With the panel mounting variants, make sure that you insert the gasket, and with the surface mounting variants, that the insert with the connections is placed correctly into the bottom part of the housing! 11 / 16

6.2 Disconnecting a cable from a 16-A / 32-A surface mounting or panel mounting socket outlet or plug 1. Make sure that the cable is de-energised. 2. For surface mounting socket outlets and plugs: Loosen the two housing screws in order to open the housing. 12 / 16

3. Loosen the screws (5) and pull out the individual conductors from the terminals. 4. Pull out the cable from the housing, and for surface mounting socket outlets and plugs, also out of the cable gland (4). 5. Fix the cover with screws to the housing (surface mounting variants). 13 / 16

7 Cleaning and care It is recommended to clean the device as required. Use a dry cloth to clean the device. Use a wet cloth if the device is very dirty. DANGER Electrical voltage The device contains parts that carry hazardous voltage that may be fatal. 1. Pull out the plugs to the loads before cleaning them. 2. Make sure that the plug covers are closed. 3. Never use steam or water jet cleaners. NOTICE Damage to the plastic parts. Corrosive cleaning agents may attack or destroy the plastic parts. Use only a cloth moistened with water for cleaning. 14 / 16

8 Decommissioning and disposal Send the worn-out product for recycling or for proper disposal. Always make sure to observe and follow the local regulations. The product should not be disposed of in household waste. Environmental damage and risk to personal health are avoided with proper disposal. 15 / 16

Bals Elektrotechnik GmbH & Co. KG Burgweg 22 57399 Kirchhundern GERMANY Tel.: +49 27 23 / 7 71-0 Fax: +49 27 23 / 7 71-1 77 E-mail: info@bals.com Disclosure to third parties only with the consent of Bals Elektrotechnik GmbH & Co. KG. All rights reserved. Only valid at the time of printing. Update when reused.