Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

Similar documents
ESPRIT. 616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL

Light " " = TRBL MODEL 633 KEYPAD TROUBLE DISPLAY. [7] Communicator fail to report. Fire trouble. Tamper or zone wiring fail. Telephone line monitor

SPECTRA 1727 USER S GUIDE

636 and 646 Keypads. User s Manual

642 LCD Keypad. User Manual

LCD and 16-Zone LED Keypads. User s Manual

10-Zone Spectra LED Keypads

Digiplex LED Keypads User s Manual

INSTRUCTION MANUAL PC255O

Digiplex LED Keypads. User s Manual

INSTRUCTION MANUAL PC255O

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Protégé Eclipse LED Keypad User Manual PRT-KLES

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

Always Armed, Never Disarmed User Guide

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

Security System. User Guide for the LED Command Center

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Security System. User s Guide for the Text Command Center

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SECURITY SYSTEM NOTES

TABLE OF CONTENTS TABLE OF CONTENTS 1

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

IDS816 User Manual H Issued January 2009

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

NetworX Series NX-1500E LED Keypad

User s Information Guide R2A

Contents. Glossary

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

NetworX NX-8V2. LED Keypad User Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

NETWORX TM. User manual NX-4

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

L900 series USER MANUAL

MG5000 MG5050 SP65 SP4000 SP5500 SP6000 SP7000. User Guide. Always Armed, Never Disarmed. Downloaded from manuals search engine

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

AXI LED USER MANUAL (REV. 1.0)

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Using Your. Security System With LED Keypad S5030, S5031, S5032

NX-148 LCD CODE PAD TABLE OF CONTENTS

Safewatch Pro 3000 System Manual

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Quick Reference Guide

Tomorrow s technology for today s security needs.

Watchguard WGAP864 User Manual

Table of Contents. Appendix A Special Characters 31

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

INSTALLATION MANUAL PC56O. Version 1.OA

EasyLoader. End User Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

INSTALLATION MANUAL PC15OO

HILLS Series LED Code Pad User Manual

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

D1265. User's Guide. Touchscreen Keypad

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

EVOHD. User Guide. Revision 1.1.

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

U ser's Guide PC6010

Destiny Destiny Owners Manual

Condominium Security Management System


Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

USER MANUAL CEF AP28 CONTROL PANEL

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

Solution Ultima Series Operators Manual ISSUE 1.00

PROGRAMMING PROCEDURES (Table 3)

Wireless Keypads LKP(E)S8M Series

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

LED Keypads D720 Series User s Guide

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

SCORPION Z16040C, Z8040C and Z5120C

HARDWIRED CONTROL PANELS

XRSuper6. User s Guide

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

DESTINY OWNER S MANUAL

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Solution Ultima 862 Operators Manual ISSUE 1.10

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

USER GUIDE HARDWIRED CONTROL PANELS

Wireless Keypad GKP-S8M

NT9005 V ZONE SECURITY SYSTEM

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Transcription:

970213-0001 ESPRIT 727 U LISTED User Manual VERSION 3.3 P R D O X S E C U R I T Y S Y S T E M S Paradox Security System Graphic Dept - PRINTED IN CANADA READY The green LED must be " on", indicating all zones are closed, before the system can be armed. When flashing, it indicates that the exit delay is in progress. ARMED The red LED illuminates when the system is armed. "FAST ARM" key ( regular/ stay mode) Press this key for 2 seconds and the system arms automatically. There's no need to enter an access code. Activates "STAY" arming. If you want to stay on the premises, but still be protected, "stay" (partial system) arming permits movement in pre-selected, unarmed zones. 10 STAY 11 Made a mistake entering info on the keypad? Just press the key - it erases any keypad entries and returns the control panel to its previous status. [CLEAR] CLEAR Activates programmable output #1 (Let your installer deal with it!!!) Programmable "chime" zones. Pressing for 3 sec any of these keys will activate chime zones (intermittent beeps) or de-activate chime zones (continuous beeps). *(SOFTWARE 3.1 AND OVER) 2ND Indicates AC power failure. When "on", this key indicates that if alarms were generated while the system was armed. Pressing on will bring up alarm "events" stored in memory. [MEM] Use this key to store keypad entries in memory. +CODE ENTER Activates manual zone bypassing. You select which zones to leave open when arming the system. "AWAY" auto bypass arming. Need to leave in a hurry? This key automatically bypasses any open zones before arming the system. BYP +CODE Press this key for 3 seconds to enable keypad buzzer total "muting" (intermittent beep) or disable it (continuous beep). TRBL AWAY 1 2 3 4 5 6 9 7 8 10 STAY 11 AWAY 12 9 12 +CODE CLEAR ENTER TRBL MEM BYP 2ND MEM

ESPRIT 727 Welcome to the world of ESPRIT technology. Your ESPRIT security system control panel is the first one of its kind designed with total ease of use and simplicity in mind. We ve harnessed the most advanced technology available to create a sophisticated control panel with powerful features that ANYONE can use, without memorizing complex, confusing codes or taking a course in computer programming!! Not only is ESPRIT easy to operate, with many functions accessible by one touch of the keypad, but it s also functional and stylish. We re sure that you ve already been impressed by its compact design and attractively styled keypads, with their adjustable illumination levels. The protection it provides will also impress you! The dwelling or building that you want to protect can be divided into up to 8 zones, and controlled by up to 5 keypads. All the security operations you need to access will be right at your fingertips. The ESPRIT keypad s comprehensive 8 zone keys, 8 function keys and keypad sounder serve to keep you instantly aware of alarm, system and operational status. Motion detectors, smoke and glass break detectors, as well as vibration/shock and door/window contact sensors will all report to the ESPRIT s two RISC microprocessor brains, and vital security information will be communicated to you on the uncomplicated keypad display. Look Everything you need to know about your security system is clearly and simply displayed on the Esprit keypad. Controlling system operations is a question of following a few straightforward instructions. The keypad diagram contained in this booklet provides you with an excellent introduction to the roles of the keypad function keys. 1

Listen Every time a key is pressed, it illuminates and the keypad beeps (0.5 second tone) to show that the entry has been recognized. When you enter information on the keypad, it will guide you with beep tones that communicate acceptance or rejection of your entries. You should be familiar with these two keypad beep tones: "CONFIRMATION" beep: When an operation (i.e. arming/disarming) is successfully entered on the keypad, or when the system switches to a new status/mode, the sounder produces an intermittent beep tone. "END/REJECTION" beep: When the system reverts to previous status, or when an operation is incorrectly entered on the keypad, the sounder emits a continuous beep tone. Code priority When deciding who should have access to your security system control panel, please keep in mind that each of the Esprit 727 master and user codes has been assigned a code priority. Code priority determines the level of security access each user will have, and which features and functions they can activate. The Master User Code ("priority 2") can arm/disarm the system, activate zone bypassing, and reprogram master and user codes. User Codes 1-3 ("priority 3") can be used to arm/disarm the system, activate "STAY" and "AWAY" arming, and zone bypassing. User Codes 4-6 ("priority 4") can arm/disarm the system and User Code 7 ("priority 5") is an "arm only" access code. more "secure". If, however, ease of recall is your priority, then 4-digit access codes can be programmed instead. Your installer will program the Esprit to accept 4 or 6 digit codes, and can also program the values for these codes. If you wish to create or change the codes yourself, you may do so by following the steps indicated below. The master code must be used to enter programming mode to program user codes. To program the master and all user codes: Press [ENTER] + master code + 1 digit access code number + new 4 or 6 digit code + [ENTER]. Note: If only 2 or 4 digits are entered, digits "00" will be enter automatically in the remaining memory space. Master code: User code 1: User code 2: User code 3: User code 4: [1] (priority 2) Arm, Disarm, Bypass, Away, Stay, reprogram master and user codes [2] (priority 3) Arm, Disarm, Bypass, Away, Stay [3] (priority 3) Arm, Disarm, Bypass, Away, Stay [4] (priority 3) Arm, Disarm, Bypass, Away, Stay [5] (priority 4) Arm, Disarm Master and User Code programming: The Esprit control panel can be programmed to accept up to 7 user codes. Depending on your security requirements, you can choose to use either 4 or 6-digit access codes with your system. 6-digit codes are considered more difficult to "crack" and are therefore viewed as 2 User code 5: User code 6: User code 7: [6] (priority 4) Arm, Disarm [7] (priority 4) Arm, Disarm [8] (priority 5) Arm ONLY 3

"ARM ONLY" CODE: This code can only be used to arm the system. No other system features can be accessed, and the system cannot be disarmed using the "Arm Only" code, unless it is used during the exit delay period. Deleting a user code: Pressing the [2ND] key + [ENTER], while in programming mode at any user code address, will delete that user code. ARMING THE SYSTEM The user-friendly Esprit 727 can be armed in 5 different ways designed to cover a wide variety of security situations. We suggest that you familiarize yourself with all 5 arming procedures so that you can take full advantage of your control panel. (1) REGULAR system arming (used for normal, day-to-day system operation) The keypad s green "READY" light must be "on" in order to arm the system. This light will only illuminate if all protected zones are closed. All doors and windows must be closed, and there can be no movement in areas monitored by motion detectors. Once the "READY" light is on, enter your user code. (The installer will program all user codes and code priorities for you.) If you make a mistake entering your code, the keypad sounders END/REJECTION beep will let you know. Just press [CLEAR] and re-enter the code. When you have correctly entered your user code, the red "ARMED" light will come on, and you will hear the keypad "CONFIRMATION" beep. The "READY" light will flash during the exit delay period. Your installer will program exit delay duration based on the time you require to safely exit the protected area once the system is armed. Important: Please note that when entering user codes, the [10] key represents the digit 0. 4 (2) STAY arming [STAY] + MASTER CODE OR USER CODES 1, 2, 3 (partial system arming) "STAY" arming allows you to remain in the protected area while "partially" arming the system. This means that you can stay in and move around your home or commercial building, while certain designated zones are armed and still receive the protection of your security system. You might choose to have entry/exit points like doors or windows protected, or the basement, or perhaps all the zones on the perimeter of your home or establishment. Based on your instructions, your installer programs the control panel to bypass these zones in "stay arming" mode. These programmed "stay" zones can only be changed during zone definition programming. (Please remember that fire zone 7 and keypad zone 8 cannot be bypassed.) Entering [STAY] + MAS- TER CODE or [STAY] + USER CODE 1 (2 OR 3) on the keypad activates the "stay arming" command. "STAY" arming can also be activated by a key switch - please refer to section on "key switch/push button arming". (3) FAST arming KEY [10] (One touch system arming - no code required) Fast arming (regular mode). When the "READY" light is on, pressing key [10] steadily for 2 seconds will automatically arm the system. No user code is required. This feature can be used to enable specified individuals like service personnel (i.e. cleaners, maintenance) to arm the system when leaving the protected area, without giving them access to any other control panel operations. ("FAST ARMING" must be activated by your installer during "panel option" programming.) Fast arming (stay mode). When activated, no "READY" light is required to arm the system. Pressing key [10] for 2 seconds automatically "STAY" arms the system. (See "STAY" arming features described 5

above.) Also, when system is stay armed, pressing key [10] will activate an exit delay and then return the system to STAY ARM status, eliminating the need to disarm and then STAY ARM the system again. (4) MANUAL BYPASS arming [BYP] + MASTER CODE OR USER CODES 1, 2, 3 (Arms the system while bypassing defective zones and/or zones you wish to leave open) When you bypass a zone, it is no longer protected by the security system. It will not generate an alarm on the control panel. You may not wish to arm the entire system when, for example, workers are renovating your basement, or you require access to a side door, or for any other reason you need to leave a zone open while arming the system. If a component of your security system is damaged, it can also be bypassed until repairs are made. Manual bypass arming instructs the control panel to ignore zones that you designate "open", so that the rest of the system can still be armed. (Based on your instructions, only zones that your installer has programmed "bypassenabled" can be bypassed during manual bypass arming, "away" arming or "stay" arming. Please note that the fire zone can never be bypassed and zone 8 is always bypass-enabled.) Press the bypass [BYP] key, followed by your MASTER CODE or USER CODE 1 (2 OR 3). You are now in "bypass" mode. [BYP] and [ENTER] will be illuminated. Enter the key numbers corresponding to the zones you wish to leave open (1-6, 8). Press twice on a key if you wish to undo a zone selection. If you have entered the correct zone bypass information, press [ENTER]. The [BYP] key light will remain on indicating that zones have been bypassed. If you make an error entering zone numbers, press [CLEAR] and key in zones again. (Pressing [CLEAR] once more will exit the bypass mode, without saving any bypass entries in memory.) 6 To cancel zone bypass entries you have just made, press [BYP] + CODE + [CLEAR] + [ENTER]. Zone bypasses are cancelled every time the panel is disarmed. Using the "bypass recall" feature, you can reinstate the latest zone bypass instructions saved in memory. Press [BYP] while in "manual bypass arming" mode and the previous bypass status will be reestablished. Even if you are in the process of entering new bypass information on the keypad, one touch of the [BYP] key will override this new information and reinstate the last zone bypass instructions you saved. (5) AWAY auto bypass arming [AWAY] + MASTER CODE OR USER CODE 1, 2, 3) (System arming without the need to enter zone bypasses) If you want to arm the system without manually entering zones to be bypassed on the keypad, you can use the "Away" auto-bypass feature. [AWAY] + MASTER CODE or [AWAY] + USER CODE 1 (2 OR 3) should be keyed in. The control panel will automatically bypass any open zones after the exit delay terminates and the system will be armed. The "ready" light does not have to be on, but all open zones must be "bypass-enabled". If any zones have been left open, the [BYP] light will illuminate to indicate that zones have automatically been bypassed. (The fire zone cannot be bypassed.) Please note: This feature is not recommended for regular use because leaving zones open can reduce the efficiency of system protection. Panic Alarms If you need to signal a "panic" situation, pressing keys [1] and [3] simultaneously for 1 second will generate a "panic" alarm. Panic alarms will be recorded in memory but not displayed on the keypad. 7

Key switch/push-button Arming Based on your requirements, your installer can replace any keypads with a key switch or a push button that will immediately arm the system. The panel can also be programmed to activate regular or "stay" arming from the key switch/push-button. This arming method is particularly useful when installed in a master bedroom, making system arming and disarming convenient and accessible. (If you use a push button/key switch to activate "stay" arming, please keep in mind that if an alarm is generated, or a zone is opened after system arming that has not been defined as a "stay" zone, the system must be disarmed from a keypad, using an access code.) DISARMING THE SYSTEM Enter the protected area using the designated entry-exit door. The keypad sounder beeps to remind you to disarm your system. Enter your user code on the keypad before the entry time expires. If you make a mistake while entering this code, press [CLEAR] and re-enter it. The "ARMED" light will go off and the sounder will stop. If a fire or 24 hour zone alarm was generated while the system was armed, entering your user code will silence the siren. However, you should then check the zone and eliminate the cause of the alarm, otherwise the zone will remain open and after 30 seconds, the siren will reactivate. If you are unable to pinpoint the reason for the alarm, call your installer immediately. Alarm Memory [MEM] The memory light [MEM] on your keypad will illuminate if any alarm situations take place while your system is armed. A record of all alarm situations that occur is stored in memory. After disarming the system, pressing once on the [MEM] key brings up the first "alarm event", which is displayed on the keypad. (An "alarm event" consists of zones that generated an alarm or that were open upon alarm.) Up to 15 levels of alarm history can be stored in memory. Each level of 8 memory is retrieved by repeatedly pressing the [MEM] key. If the "END/REJECTION" beep is heard, this indicates that the last recorded level or the maximum level of alarm history has been reached. When the memory is full, the newest event takes the place of the oldest one in memory. After pressing of the [MEM] key, events will be displayed in order from the most recent to the oldest. To review alarm history again, press [MEM] key. Exiting memory mode is achieved by pressing [CLEAR] or [ENTER], which will be followed by the "END/REJ" beep. The [MEM] light also goes out. When you arm the control panel again, system memory will not clear and alarm history is saved. "Energy-Saver" Programming: The ESPRIT 727 can be programmed to reduce energy consumption in the protected area. Just ask your installer about this option, which can automatically lower building temperature and/or turn off lights upon system arming. When the system is disarmed, the panel will return building temperature to its previous level and turn the lights back on. PS1 Bedside remote module Pressing any one of the three keys of this module will arm or disarm the system in "Stay" mode (when partitioning is not activated). Please note that if the system is in entry delay or if an alarm is in progress, for your protection, the panel can only be disarmed from a keypad. Pressing any two PS1 keys simultaneously will generate a panic alarm. Your installer can also adjust the PS1's illumination level and mute the buzzer as required. Keypad night illumination Pressing on the [MEM] key for 2 seconds changes it to the keypad illumination key. Subsequently, pressing on this key alters the illumination level from low, medium, to high, and then "off". Keep pressing on the [MEM] key until you reach the level you require, then press [ENTER] or [CLEAR] to save the setting in system memory. 9

Chime zones Zones 1 to 6, as well as the local keypad zones, can be programmed as chime zones. A chime zone "advises" you when it is opened by creating a rapid intermittent beep tone. To turn on the "chime zone" feature, press on the selected zone key for three seconds until the intermittent chime beep is heard. This means that the chime feature has been activated. If a continuous beep is heard, this means that the chime is "off". (The keypad zone chime is enabled by pressing key [8].) If you have more than one keypad in your system, please "chime" program each keypad separately. Keypad chimes must be reprogrammed if the panel suffers total power loss. CHIME KEYS: Key [1]-[6] Turns chime "ON" or "OFF" in zones numbered 1-6. Key [8] Turns the chime "ON" and "OFF" for the zone connected to this keypad. Each keypad must be programmed independently. PANEL BUZZER MUTE: Key [9] Turns keypad sounder "ON" and "OFF" (intermittent beep means MUTE is activated, and keypad sounder is "OFF". Depress for 2 seconds to disable.) Trouble Display [TRBL] AC power failure will be communicated to you by the illumination of the keypad [TRBL] indicator. If you are unable to find the cause of AC power loss, contact your installer/alarm company immediately. IMPORTANT: Keep this information in a secure location. ZONE DESCRIPTION 24Hr Bypass Enabled Zone 1: l l Zone 2: l l Zone 3: l l Zone 4: l l Zone 5: l l Zone 6: l l 24Hr Fire Zone 7: l l Zone 8: 10 11

ACCESS CODES SPECIAL KEYS AND FUNCTIONS Name Code Arming Priority l 4 digit l 6 digit Reg. Stay Away Byp Master 00 l l l l User 01 l l l l User 02 l l l l User 03 l l l l User 04 l User 05 l User 06 l l Key [10] Regular arming is activated. [1] and [3]* Police or l Enabled l Disabled *Both keys must be depressed at the same time for 2 seconds - Armed LED will flash. The PGM (Programmable Output) function (if applicable), is and is activated by. SYSTEM TIMES Entering and exiting your premises is permitted through doors that you and your installer have determined. You have seconds to EXIT your premises. Your Entry delay is seconds and you may enter through zone #. Your siren, if activated by an alarm, will sound for minutes. User 07 l OTHER INFORMATION This alarm system was installed on: By:. Service is provided by Tel:. Your monitoring station's telephone number is:. Your account number is:. NOTE: FOR SECURITY REASONS WRITE ONLY USER NAMES AND NOT ACTUAL ACCESS CODES! Your alarm transformer location is and is on circuit #. 12 13

WARRANTY Warranty conditions for the Esprit 727 may vary from country to country. Please consult your local dealer for complete warranty information. In all cases, the warranty does not cover malfunctions arising from installer error or failure to follow installation/operation instructions, nor does it apply to damages due to causes beyond the control of Paradox Security Systems, such as lightning, excessive voltage, mechanical shock or water damage. LIABILITY Under no circumstances shall Paradox Security Systems. be held liable for any direct or indirect damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation, operation or failure of this product. WARNING This security system should undergo frequent testing. However, despite regular testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. Look for and marks on products. Only products bearing those marks are UL and ULC listed. Paradox Security Systems - Graphic Dept. - PRINTED IN CANADA