Technical Application LED Pendant Light LUZ-PL412-25W-W
Introduction Pendant led light acts as a decorative light in most applications. Elegant design creates soft lighting effect, suspended installation with adjustable mounting height, perfect for hotels, restaurant, coffee shop etc. 4mm, 6mm diameter for wide choice. Up to 8% energy saving compared to standard CFL Long lifetime of 4, hours 12 wide beam angle CCT: 3K 4K 5K 57K No UV/IR light Environment friendly, without Mercury or any other hazardous substances Application notes IP4 for indoor use only Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas It is widely used for various commercial and residential lighting applications, such as office, hotel, restaurant, home lighting etc. Certificates
Product Information Height adjustable Technical Specifications Model Voltage Power Power Factor Lumen (±5%) Beam angle CCT Lifespan CRI Dimmable Dimension LUZ-PL412-25W-W AC1-24V 25W.9 22 12 o 3K 4h 8 No Ø4*12mm LUZ-PL412-25W-W AC1-24V 25W.9 21 12 o 4K 4h 8 No Ø4*12mm LUZ-PL412-25W-W AC1-24V 25W.9 215 12 o 5K 4h 8 No Ø4*12mm LUZ-PL412-25W-W AC1-24V 25W.9 217 12 o 57K 4h 8 No Ø4*12mm LUZ-PL412-25WD-WAC2-24V 25W.9 2 12 o 3K 4h 8 Yes Ø4*12mm LUZ-PL412-25WD-WAC2-24V 25W.9 25 12 o 4K 4h 8 Yes Ø4*12mm LUZ-PL412-25WD-WAC2-24V 25W.9 21 12 o 5K 4h 8 Yes Ø4*12mm LUZ-PL412-25WD-WAC2-24V 25W.9 212 12 o 57K 4h 8 Yes Ø4*12mm Driver data Sheet Fixture Compatibility Rated Wattage Driver data Dim Non-dim Input rated Voltage AC23V AC1-24V Frequency 5Hz 5/6Hz Input Voltage AC2-24V AC85-265V Efficiency 85% 86% Total load Wattage 25W±5% 25W±5% Power Factor.9.9 Rated input current.12a.28a Full load output Voltage DC35-4V DC35-4V Rated output current 58mA 58mA Output current range 58mA±5% 58mA±5% Tolerance ±5% ±5% Current output tolerance ±5% ±5% Dimming range 8%-1% Dimmer Triac dimmers Short circuit protection PASS PASS Over voltage protection PASS PASS Over temperature protection PASS PASS Withstand voltage AC15V AC15V Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 25W Ⅰ IP4-2 o C~45 o C ~9% -2 o C~65 o C
Spectral Distribution 3K 4K.8.7.6 Max=6595 [1.=2] 4.17SDCM F3K.8 Max=7572 [1.=2].7.6 3.86SDCM F4K.5.4.3 x=.472 y=.4228.5.4.3 x=.4472 y=.417.2.2.1.1.. 38 5 6 7 8 38 5 6 7 8 5K 57K.8.7.6 Max=8572 [1.=2] 3.9SDCM F5K.8 Max=7373 [1.=2].7.6 3.6SDCM F57K.5.4.3 x=.3866 y=.3848.5.4.3 x=.3523 y=.3684.2.2.1.1.. 38 5 6 7 8 38 5 6 7 8 Photometric Diagram 3K 4K -12-9 -/+18 11 12 9 MH=1m C/18 C9/27 Flux out: 168 lm 3.281ft 14.55, 48.94fc 1m 156.7, 526.8lx 6.562ft 3.638, 14fc 2m 39.16, 131.7lx 9.69ft 295.34cm 19.38ft 59.68cm -12-9 -/+18 11 12 9 MH=1m C/18 C9/27 Flux out: 18 lm 3.281ft 13.7, 46.69fc 1m 147.4, 52.6lx 6.562ft 3.424, 11.67fc 2m 36.85, 125.6lx 9.93ft 32.68cm 19.86ft 65.36cm 22 9.843ft 1.617, 5.438fc 3m 17.41, 58.53lx 29.7ft 886.2cm 22 9.843ft 1.522, 5.188fc 3m 16.38, 55.84lx 29.79ft 98.4cm 33 33 44 55-3 3 UNIT: cd AVERAGE BEAM ANGLE(5%): 112.1 DEG.55-25 -2-15 -1-5 5 1 15 2 25 13.12ft.996, 3.59fc 38.76ft 13.12ft.856, 2.918fc 39.72ft 4m 9.791, 32.92lx 1181.36cm 44 4m 9.214, 31.41lx 121.72cm 55 16.4ft.4687, 2.123fc 47.4ft -3 3.55 16.4ft.5478, 1.868fc 49.65ft 5m 5.21, 15.24lx 1455.6cm 5m 6.897, 2.1lx 1519cm -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 113.77deg Diameter UNIT: cd Height Eavg, Emax Angle: 113.9deg Diameter AVERAGE BEAM ANGLE(5%): 115.3 DEG 5K 57K -12-9 -/+18 11 12 9 MH=1m C/18 C9/27 Flux out: 187 lm 3.281ft 15.21, 45.3fc 1m 14, 465.3lx 6.562ft 4.51, 12.61fc 2m 45.12, 185.6lx 9.686ft 298.99cm 19.41ft 595.13cm -12-9 -/+18 11 12 9 MH=1m C/18 C9/27 Flux out: 192 lm 3.281ft 13.42, 44.15fc 1m 14.1, 463.4lx 6.562ft 4.321, 11.3fc 2m 37.33, 12.4lx 9.61ft 296.55cm 19.15ft 59.58cm 22 9.843ft 1.742, 5.632fc 3m 15.32, 57.54lx 29.4ft 89.1cm 22 9.843ft 1.425, 4.988fc 3m 15.63, 51.24lx 28.77ft 876.93cm 33 33 44 55-3 3 UNIT: cd AVERAGE BEAM ANGLE(5%): 115.3 DEG.55-25 -2-15 -1-5 5 1 15 2 25 13.12ft.888, 3.15fc 39.14ft 13.12ft.8344, 3.425fc 38.36ft 4m 9.54, 32.44lx 1193.11cm 44 4m 9.151, 29.33lx 1169.25cm 55 16.4ft.52, 1.754fc 48.54ft -3 3.55 16.4ft.5871, 1.451fc 47.5ft 5m 5.764, 19.21lx 148.3cm 5m 5.758, 19.11lx 153.22cm -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 112.66deg Diameter UNIT: cd Height Eavg, Emax Angle: 117.25deg Diameter AVERAGE BEAM ANGLE(5%): 114.9 DEG
Polar Diagram Comparison -15 O +/-18 O 15 O -12 O 12 O -9 O 9 O 11 22-6 O 33 6 O 44-3 O 55 3 O O AVERAGE BEAM ANGLE (5%): 115.4DEG UNIT: cd C/18, 112.9 deg C3/21, 114.9 deg C6/24, 114.1 deg C9/27, 113.4 deg Driver lifetime & LED lifetime Driver Lifetime LED Lifetime 9 11%.4 Lifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % Luminous Flux 15%.35 1%.3 95%.25 9%.2 85%.15 8% 75% FLUX.1.5 U'V' 7%. 1 2 3 4 5 6 7 8 9 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be 12 C The highest withstand temperature of LED junction temperature is 15 C 8 Temperature ( o C) 7 6 5 4 3 2 1 14:29:22 15:2:16 16:11:16 17:2:16 17:53:16 18:44:16 19:35:16 2:26:16 21:17:16 22:8:16 22:59:16 23:5:16 :41:16 1:32:16 2:23:16 3:14:16 4:5:16 4:56:16 5:47:16 6:38:16 7:29:16 8:2:16 Time The driver lifespan is based on capacitor working temperature. IC Capactior MOS PCB Fitting Voltage transformer Environmental temperature
Installation Wooden ceiling: 1. Unbox panel light and accessory pack. 2. Switch off, fix bracket into ceiling with screw. 4. Fix the wall mount bracket into ceiling by screw. 5. Hang panel to suspending rope and connect the DC connector 3. Insert the hanging wire into wall mount bracket; connect L/N/E to mains supply. 6. Adjust the length of hanging wire to proper height, Restore the power and switch on. Concrete ceiling: 1. Unbox panel light and accessory pack 2. Power off, Punch holes and knock the plastic anchor into ceiling 4. Insert the hanging wire into wall mount bracket; connect L/N/E to mains supply. 5. Fix the wall mount bracket into ceiling by screw. 3. Fix bracket into ceiling with screw. 6. Hang panel to suspending rope and connect the DC connector
7. Adjust the length of hanging wire to proper height, Restore the power and switch on Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 4*21.5*65 3.1 1 4 2'' standard container 4'' standard container CTNS Q'TY(PCS) VOLUME(CBM) 433 1732 28 866 3464 56 LUZON LIGHTING 1945 B STREET SUITE A - SAN DIEGO - CA - 9212 Ph:619 878 273 usa@luzonlighting.com / www.luzonlighting.com