Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

Similar documents
MINITOP Refrigerated Self-Service Display underneath

OMNITOP Refrigerated Display with Ventilated Cooling

REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7

Dixell Installing and Operating Instructions release 7.0

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

XWA11V. Walk-In Temp / Door /Alarm / Light Module

dixel Installing and Operating Instructions PRELIMINAY

Commercial Refrigerator Service Manual

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Commercial Freezer Service Manual

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

dixel Installing and Operating Instructions

Top Mount Full Length Swinging Doors

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING

Refrigerated Milk Drawer

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15

Refrigerated air dryers

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display.

Refrigerated Cabinets Square Format

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

XW40K AND T620T - T620 V620 CX620


Electronic Controller For Refrigeration XLR130 XLR170

Read and save these instructions

Inline GN Series Refrigerated Well

UNIVERSAL R V3.0. NEW FEATURES on the V3.0

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line

Open Front Food & Drinks Cabinet AS/NZS

Read and save these instructions

Food & Beverage Cabinet

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4.

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Refrigerated Cabinets

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1

TOQUE BLANCHE GRANDE CARTE

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

Upright Chiller & Freezer Service, Installation and Care Manual

Refrigerated Cabinets Curved Format

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

XB570L XB570L. dixel Operating and Instructions Manual BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION

Refrigerated Cabinets Curved Format

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications

Read and save these instructions

Beverage Air IMPORTANT

Read and save these instructions

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

CIAO series ICE CREAM DISPLAY CABINET. Maintenance And Use Manual

Read and save these instructions

IKEA USA Refrigerated Cabinets

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

INSTALLATION AND OPERATING MANUAL

Read and save these instructions

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Split Wall-Recessed Cooling System Operation Care Installation Manual

Read and save these instructions

CAREL IR33+ CONTROLLER

REF Series Undercounter Refrigerator

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRIMLINE KA6C4NP28L

Solid Door Top Mount Reach-In Freezer

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

INSTALLATION AND OPERATING MANUAL

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

INSTALLATION AND OPERATING MANUAL

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner. GUARDIAN SERIES K3NA4C3DP24L 480 Volt 1-PHASE

INSTALLATION AND OPERATING MANUAL

G1F-23-B-1 G1F-23-W-1

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTREPID SERIES K2A6C30EP56TR-4

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner SLIMKOOL SERIES K_NA4C4SP28L

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Instruction Manual Reach-In Refrigerators & Freezers

Chef Base Refrigerators

JDDT1 - Single Stage Digital Thermostat

Read and save these instructions

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C18DP53L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C26DP60L

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Glass Door Merchandiser Refrigerator and Freezer

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner. HAZARDOUS LOCATION SERIES K_A6C6HL40LV U.S. Pat. No.

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner. DP SERIES KA4C3DP21L with Serial Numbers L18A3965 and above

Side-by-side combined refrigerator-freezer

USER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model

FX BLAST CHILLER ISO ISO 9001

Transcription:

INOUK Upright refrigerated display Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles Hermite Z.I. des Sables BP 59 54110 Dombasle sur Meurthe France tel : (+33) 03 83 45 82 82 - fax : (+33) 03 83 45 82 93 e-mail : commercial.vcs@vauconsant.com export@vauconsant.com

INSTRUCTIONS OF USE AND MAINTENANCE GENERAL POINT Refrigerating components Refrigeration by a ventilated evaporator located in the bottom of the display. deflector Lighting Lighting by fluorescent tube located I n the top of the display. Controls High precision control by thermostat with digital display ( to refer to the note of the thermostat provided hereafter ). Started and stop of the regulation by pressure on the key of the keyboard of the thermostat. Lighting: started and stop of lighting by pressure on the key of the keyboard of the thermostat. Control devices placed on the panel of aeration of the compressor group of the display. Protection By main power fuse holder. INSTALLATION Electric connection Before plugging in the unit, control imperatively the voltage rating : it should be the same voltage as indicated on the unit. The electric power line providing the refrigerated unit with electricity should be protected by a differential circuit breaker located on the main electric distribution panel. To connect the incoming line to the fuse holder located in the electric box. To connect the plug of the self evaporating tray. Compressor connection ( when the compressor group is not supplied with the display). To connect the refrigerating circuit, in accordance with the refrigerating diagram, provided hereafter. Important If the display is positioned against a wall, it is advisable to remove the fenced panel, to assure a sufficient ventilation for the functioning of the refrigerated group. To set up the self evaporating tray The self evaporating tray must be placed under the unit, at the place designed, by means of the clips initially installed. The installation twist of the self evaporating tray must be connected to the plug of the electric box, according the standard of unit, the twist of the self evaporating tray can be situed in the face or in the back of the unit. Astainless steel sheet deflector located in the self evaporating tray, allow to direct the water vapour. The sheet must be located in the middle of the self evaporating tray ( the same distance in each side). The deflector must be located to have the good direction of the inclination, like described in the following diagram. HOW TO USE To put into service Powering up the unit two hours before usage. Press the key of the thermostat When the thermostat is activated, the power unit starts running a minute later (safety timeout) to supply power. The thermostat is adjusted in the factory after testing. When the desired temperature is obtained, the power unit automatically turns off. Press the key of the thermostat to turn off the regulation of the unit. Lighting Press the key lighting. Adjusting the thermostat Refer to the manual for details. of the thermostat to turn on or turn off the Automatic defrosting This function is programmed in the thermostat/ Adjusted in the factory: the defrosting engages every hour throughout one ten maximum minute. To modify the adjustment, refer the manual of the thermostat. Cleaning To be performed when the display is shut down (the unit is turned off). Once a day, wash the top, the refrigerated well and the external sides of the display. Use a sponge moistened with a soapy water or special cleaning products to clean the stainless steel. Rinse off with water. Dry preferably with lint-free cotton cloths. Do not use floor cleaning products or acids, even diluted, chlorinated or scouring products, which may cause corrosion to stainless steel. Do not use any abrasive products (steel wool, etc ). Do not clean the refrigerated unit by spraying with water, using a soap gun, or under high pressure jets. MAINTENANCE The installer should check all the electric connections during the initial start up of the unit (and then once a year). Clean the condenser every six months. Grease the condenser blower shaft once a year. 2

ELECTRIC DIAGRAM REFRIGERATING DIAGRAM CAPTION DIAGRAMS B Ballast Rb Resistance of the self evaporating tray Bl Liquid bottle Sa Atmosphere temperature probe C Compressor Sd Defrost temperature probe Cd Condensor Sf Starter D Relief valve Sn Level water probe of the self evaporating tray Dh Drier T Thermostat E Evaporator Tb Safety thermostat of the self evaporating tray Ev Defrost electro-valve Tf Fluorescent tube Kb Relay of the self evaporating tray V Ventilator of the display chiler Q Fuse holder Vc Ventilator of the condensor 3

MANUAL OF THERMOSTAT XW60L Please read this manual before using 1.AVERTISSEMENT Warning: disconnect all electrical connections before any kind of maintenance. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to with a detailed description of the fault. 2.DESCRIPTION Model XW60L is microprocessor based controllers suitable for applications on medium or low temperature refrigerating units. They are provided with 4 relay outputs to control compressor, defrost, fans for the evaporator and the lights. They are also provided with 2 NTC probe inputs, for temperature control, the second for end defrost temperature control. The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. 3.KEYBOARD To display and modify target set point; in programming mode it selects a parameter or confirm an operation. By holding it pressed for 3s when max or min temperature is displayed it will be erased. To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value. By holding it pressed for 3s the fast freezing cycle is started. To see the min stored temperature; in programming mode it browses the parameter codes or decreases the displayed value. By holding it pressed for 3s the defrost is started. Switch ON and OFF the light of the cold-room. Switch ON and OFF the instrument. KEY COMBINATIONS + To lock and unlock the keyboard. + To enter the programming mode. + To exit the programming mode. 3.1 To lock and unlock the keyboard HOW TO LOCK THE KEYBOARD Keep the and the keys together for more than 3 s. The "POF" message will be displayed and the keyboard is locked. At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light, the auxilary output and the instrument. 4 HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s. The "POn" message will be displayed and the keyboard is unlocked. 3.2 Meaning of the LED Each LED function is described in the following table : LED MODE FONCTION ON The compressor is running Flashing Programmation phase ( flashing with Anti-short cycle delay enabled ) ON The fan is running. Flashing Programmation phase ( flashing with ) ON The defrost is enabled. Flashing Drip time in progress ON The fast freezing cycle is enable Alarm signal ON In Pr2 indicates that the parameter is also present in Pr1 ON The light is on 3.3 How to see the min temperature Press and release the n key. The Lo message will be displayed followed by the minimum temperature recorded. By pressing the n key or waiting for 5s the normal display will be restored. 3.4 How to see the max temperature Press and release the o key. The Hi message will be displayed followed by the maximum temperature recorded. By pressing the o key or waiting for 5s the normal display will be restored. 3.5 How to reset the max and min temperature recorded To reset the stored temperature, when max or min temperature is displayed, press SET key until rst label starts blinking. N.B. : After the installation RESET the temperature stored. 3.6 How to see and modify the set point Push and immediately release the SET key: the display will show the Set point value. The SET LED start blinking. To change the Set value push the or arrows within 10s. To memorise the new set point value push the SET key again or wait 10s. 3.7 To start a manual defrost Push the DEF key for more than 2 seconds and a manual defrost will start. 3.8 To enter in parameters list Pr1 To enter the parameter list Pr1 (user accessible parameters) operate as follows: Enter the Programming mode by pressing the Set and DOWN key for few seconds ( and start blinking). The instrument will show the first parameter present in Pr1.

3.9 To enter in parameters list Pr2 To reach the parameters present in "Pr2" (parameters accessible to the technicians), please contact, which will deliver you the secret code making it possible to reach these parameters. 4. ALARM SIGNALS Message Cause Output "P1" "P2" "HA" "LA" "EE" "da" "EAL" "BAL" "PAL" Thermostat probe failure Evaporator probe failure Maximum temperature alarm Minimum temperature alarm Data or memory failure Door switch alarm External alarm Serious external alarm Pressure switch alarm Alarm output ON; Compressor output according to parameters COn and COF OFF OFF The alarm message is displayed until the alarm condition is recovery. All the alarm messages are showed alternating with the room temperature except for the P1 which is flashing. To reset the EE alarm and restart the normal functioning press any key, the rst message is displayed for about 3s. 4.1 EE alarm The instruments are provided with an internal check for the data integrity. Alarm EE flashes when a failure in the memory data occurs. In such cases the alarm output is enabled. 4.2 Alarm recovery Probe alarms P1 (probe1 faulty), P2 ; they automatically stop 10s after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms HA and LA automatically stop as soon as the thermostat temperature returns to normal values or when the defrost starts. 5. PARAMETERS PROGRAMS IN FACTORY Parameter Name Default value following the length of the display chiler 850 1350 1550 Set Set point 2 2 2 Hy Différential 2 2 2 AC Anti-short cycle delay 1 1 1 res Resolution DE DE DE tdf Defrost type In In In dte Defrost termination temperature 3 3 3 IdF Interval between defrost cycles 2 2 2 MdF (Maximum) length for 1 defrost 10 10 10 ALU MAXIMUM temperature alarm 150 150 150 ALL Minimum temperature alarm -50-50 -50 ot Thermostat probe calibration 6 4 4 P2P Présence sonde évaporateur N N N Adr Address series (unused) 1 1 1 P2r Access parameter list ( read only) 5

Code SPARE PARTS Item description Length of the unit 870 1350 1550 Accessories 02.2362 Shelf support X X X 03.0691 Shelf thickness 10 mm, 795 x 360 X 03.0693 Shelf thickness 10 mm, 1275 x 360 X 03.0695 Shelf thickness 10 mm, 1475 x 360 X 03.0981 Avoid-breath 800 x 175 X 03.0983 Avoid-breath 1280 x 175 X 03.0985 Avoid-breath 1480 x 175 X 03.1663 Lateral glass thermopane 1348 x 780 thickness 14 mm X X X Electric equipment 06.3415 Ventilator evaporator 127 x 127 x 38 standard 5958 X X X 12.0272 Thermostat WING XW60L X X X Refrigerating equipment 12.0204 Relief valve TS 2 FL/BR X X X 12.0206 O2 tub for relief valve X X X 12.0256 Drier DN 83 X X X 12.0300 Electro-valve X X X 12.2470 Evaporator length 620 mm X 12.2472 Evaporator length 1100 mm X 12.2474 Evaporator length 1300 mm X Condensation group 12.2780 Group condensation CAE 9480 ZMHR X 12.2800 Group condensation CAJ 9513 ZMHR X 12.2806 Group condensation CAJ 4517 ZH 517 F X Self evaporating tray 06.0038 Resistance 600 W X X X Lighting 06.4780 Fluorescent tub length 590 mm power 18 W X 06.4784 Fluorescent tub length mm power 36 W X 06.4786 Fluorescent tub length 1200 mm power 36 W X 06.4800 Casing X X X 06.4801 Casing with starter X X X 06.4810 Ballast for fluorescent tub 18 W X 06.4812 Ballast for fluorescent tub 36 W X X 06.4816 Plastic sleeve for fluorescent tube length 590 mm X 06.4817 Plastic sleeve for fluorescent tube length 970 mm X 06.4818 Plastic sleeve for fluorescent tube length 1200 mm X 6