"ER" Series Electric Humidifier

Similar documents
"ESDDR" Series Electric Humidifier

"SXDDR" Series Steam Heat Exchanger Humidifiers

ES Series Electric Humidifier

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

EC Series Wall Unit Humidifier

Installation Instructions. Operation and Maintenance Manual

Installation Instructions. Operation and Maintenance Manual

Steam Humidification Light Commercial Applications. Better technology means better business.

CUFFED FAST-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

INSTY-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

Insty-Pac Steam Humidifiers

READ AND SAVE THESE INSTRUCTIONS XTR. Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

Residential Steam Humidifier

HumidiClean Series HC-4000 Humidifier

Humidifiers Dealer Parts List

Installation Instructions. Operation and Maintenance Manual

CAREL heatersteam Electric Element Steam Humidifiers

SECTION HUMIDITY CONTROL EQUIPMENT

INSTY-PAC INTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

HumidiClean. Series HC- 4100/4145/4300/4500 Humidifiers. Installation, Operation and Maintenance Instructions. Table of Contents.

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Humidifiers Dealer Parts List Model 400/400M Humidifiers

NH Series Electric Steam Humidifiers

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

INSTY-PAC EXTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

Installation and Maintenance

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

DRI-STEEM CRU SERIES ELECTRIC STEAM HUMIDIFIERS

Steam Humidifier Models 1150 and 1160

TYPICAL INSTALLATION Figure A. Condensate Return Line. Humidifier Cabinet. Drain Line

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ULTRA-SAFE Explosion-proof Duct Heaters

LE Series. Electrode Steam Humidifiers

HumidiClean Series HC-6000 Humidifier Revolutionary ionic bed technology that carries a lot of weight

Quick Start Installation Guide

Humidification Systems Product Guide

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

HumidiClean Series HC-6000 Humidifier Revolutionary ionic bed technology that carries a lot of weight

RHP120 RHP300 Steam Boiler Series

Modular Supply Make-Up Air Unit

Guide Specifications for InRow Direct Expansion

INTAC Microprocessor Humidifier Controller

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

MD-170 Installation/Operator's Manual

DRI-STEEM Models and LTS-DI

VAPORSTREAM Models VLC and VLDI

A HEATER KIT With Diesel Engine Connection Fittings

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

ULTRA-SAFE Explosion-proof Duct Heaters

FX5 Series Explosion-Proof Electric Air Heaters

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access Interoperability via Modbus or optional BACnet or LonTalk

READ AND SAVE THESE INSTRUCTIONS XT SERIES. Electrode Steam Humidifiers. Installation, Operation, and Maintenance Manual

CRUV. Electric Humidifier. Installation, Operation, and Maintenance Manual

DRI-STEEM Models LTS and LTS-DI

BASIL 6000 TUNNEL CAGE WASHER

XTR Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

Tubular Industrial Process

Control and power circuit fusing to meet N.E.C.

State of the Art. Exceptional Reliability

READ AND SAVE THESE INSTRUCTIONS XT SERIES. Electrode Steam Humidifiers. Installation, Operation, and Maintenance Manual

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Steam Humidifier. SK300 Series Installation Instructions and User Manual. SK300-ESL docx

Custom Duct Heaters. Special Applications

HumidiClean Series HC- 6100/6300/6500/6700 Humidifiers Installation, Operation and Maintenance Instructions

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

L A signature series TA T N E RE O, A L L A T S IN

GS Series. Gas Steam Humidifiers. Designed for air handling systems and for areas requiring individual humidification control

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

SINGLE DUCT TERMINAL UNITS

Product Data. HUM Humidifiers. FEATURES/BENEFITS (Bypass & Fan Powered Models) FAN POWERED MODELS BYPASS MODELS STEAM MODEL

NH Series. Installation and Operation Manual

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Scotsman Technical Training. CU50 Cube Ice Machine

CF1 ProVector Explosion-Proof Heaters

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

XT Series Electrode Steam Humidifier. Installation, Operation, and Maintenance Manual

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Direct Gas-Fired Make-Up Air

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Tubular Industrial Process

A state-of-the-art humidifier improves indoor air quality, enhances a family's health and comfort while protecting valuable objects in a home!

STEAMPRO. Steam Generator Troubleshooting and Service Guide

MES2. Installation and Operation Manual

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Pressure Steam Humidifiers LS SERIES. humidity.com

CX1 ProVector Explosion-Proof Heaters

ComfortSTEAM TM. Humidification System

Installation and Maintenance

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

Transcription:

ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the humidifier does the rest. These units feature a Tri-Probe sensor made up of three Teflon -coated stainless steel probes. The lower probe prevents the heating elements from energizing when the water level is too low. The middle probe electrically activates the water control valve to fill the reservoir. The top probe shuts off the water control valve when the water level reaches the proper height. A control box constantly monitors the humidifier cycle for efficient operation. High efficiency immersion water heaters heat the water to provide steam. Furthermore, a flusher serves to constantly remove surface water mineral build-up, and doubles as a water overflow safety pipe to the drain. A standard accumulative timed drain cycle performs automatic draining and flushing, thus reducing mineral build-up within the reservoir. When it comes to installation, you have a choice with the Electric Humidifier. The humidifier can be free-standing with a simple (optional) flexible hose connecting the unit to the stainless steel injection tube inserted through the duct wall. For mounting under a duct you simply need hangers and support brackets. They may also be mounted inside the air handling system (local codes may require moisture-proof construction of certain components). The versatility of the Electric Humidifier allows you to design these easy-toclean units into any system simply, efficiently, and reliably. Our results are comforting 5-10

Capacities & Weights Electrical Specifications ER-2 Capacities & Weights Standard Humidifier Reservoir Weight Steam Output Capacity Water Unit Empty Full Model No. lbs/hr kg/hr KW lbs kg lbs kg ER-1 3 1.4 1 42 19 70 31.4 ER-3 9 4.1 3 42 19 70 31.4 ER-5 15 6.8 5 42 19 70 31.4 ER-6 18 8.2 6 42 19 70 31.4 ER-7 21 9.5 7 42 19 70 31.4 The above capacities are based on 100% efficiency. Actual humidifier capacity may vary due to the heat loss from the humidifier reservoir. The ambient air temperature, air velocity, and injection tube system will affect the rate of heat loss from the humidifier reservoir. Single Phase Amperage* Standard Water Unit No. of Control Circuit Heater KW Unit Model No. KW Heaters Voltage 120V 208V 240V 480V 600V ER-1 1 8.3 4.8 4.2 2.1 1.7 1 1.0 24 vac ER-3 3 25.0 14.4 12.5 6.3 5.0 1 3.0 24 vac ER-5 5 24.0 20.8 10.4 8.3 2 2.5 24 vac ER-6 6 28.8 25.0 12.5 10.0 2 3.0 24 vac ER-7 7 14.6 11.7 2 3.5 24 vac * Other voltages available upon request. Please consult factory for specific availability.

Dimensions & Layout ER-3 1 1/2 Ø Steam Outlet Connection 15.375 (39.0) 11.00 (27.9) Top View Electrical Control Box 7.375 (18.7) 1/4 -NPT Water Inlet & Strainer 16.75 (42.5) 9.375 (23.8) 3/4 Copper Sweat Drain Connection Drain Valve 12.375 (31.4) 14.625 (37.1) Front View Right Side View

Humidifier Features ER-4 Controls Cover Optional SCR Control Optional Time Cycle Modulation Control Water Level Control Tri-Probe Sensor Reservoir Cover Immersion Heaters Humidifier Reservoir 1/4 IPS Water Inlet and Strainer Motorized Drain Valve Drain & Overflow Outlet

Specification Sample ER-5 Humidifier 1. The humidifier shall be electrically heated immersion heater type as manufactured by PURE Humidifier Co. of Chaska, Minnesota. 2. The humidifier shall be tested and approved by ETL Testing Laboratories, Inc. 3. The humidifier shall have an evaporating reservoir with a gasket-sealed cover that is capable of operating at pressures of at least 19 (48 cm- W.C.) without steam or water leaks. The reservoir shall be made of type 304 stainless steel with welded joints. 4. A surface water flusher shall be included to drain away a portion of the water upon each refill cycle. This is to allow mineral deposits produced by earlier evaporation cycles to be removed. Flusher shall be designed for minimal water waste and efficient flushing. 5. The immersion heater(s) shall be incoloy-sheathed and designed for 80 watts per square inch. They shall be attached to the reservoir cover and be easily removed for cleaning or inspection. Expansion and contraction of the heater sheath allows mineral build-up to flake off. 6. A brass body, solenoid operated water fill valve shall be factory-mounted on the body of the humidifier reservoir. The fill valve shall be located to allow a minimum water gap of 1-1/2 (3.81 cm). 8. A solid state, plug-in type control module shall be factory-mounted in the controls box and shall electronically control the automatic refilling, low water cut-off, high water cut-off, manual surface water flushing, and safety switch interlock functions. The module shall include automatic drain functions to drain the reservoir. A cumulative timer shall be field adjustable between 10 to 150 hours of operation. When the system is activated the fill valve will be energized to provide a cool-down tempering of the water prior to draining. The control module shall incorporate LED lights to indicate safety switch interruption, power, fill, heat ready, and drain. The control module shall control all water level control functions through a Tri- Probe sensor mounted on the cover of the humidifier reservoir. The Tri-Probe sensor with stainless steel shield shall electrically sense the water level within the reservoir. 9. The electrical control box shall be mounted on the humidifier cover. The control box shall include a magnetic contactor, water level control module, fused control circuit transformer, numbered terminal block, and heater fuse(s). The high voltage wiring shall be shielded to prevent shock hazard. The modulating control voltage shall be field adjustable to match the controlling input signal. 7. The humidifier shall have a manual reset overtemperature switch factory-installed on the humidifier reservoir cover. The temperature switch shall provide humidifier over-temperature protection. Reference the Options page for a description of the options which can be added to the base specification.

Options ER-6 Humidifier Insulation. Unit shall be covered (except top cover) with 3/4 (1.9 cm) thick fiberglass duct insulation. Insulation material shall have aluminum foil facing. Dispersion Methods Injection Tube(s) and Flexible Hose. Each unit shall include one 10-foot (305 cm) section of 1-1/2 (3.8 cm) I.D. flexible hose and a 1-1/2 (3.8 cm) O.D. stainless steel injection tube long enough to extend across the duct. Steam ports shall direct steam upward into the airflow. The reservoir cover shall have a matching connection so the flexible hose can be connected with two stainless steel hose clamps. A two-piece duct plate shall be provided to seal the duct opening. Blower Pack. Unit shall allow for direct space humidification without the use of ductwork. Unit shall be contained within a cabinet that is constructed of 18-gauge steel with a baked enamel paint finish. Unit shall have a two -speed field-adjustable fan. The fan is controlled by a thermostat interlock mounted on the steam distributor, it shall activate the fan before steam is discharged and deactivate the fan after all residual steam has been discharged. The blower shall be designed for remote wall mounting. Modulating Controls (select one) Time Cycle Modulation. A TCM controller shall be factorymounted and wired on the control panel and provide modulating control of the humidifier capacity from 0-100%. The heaters shall be time cycle modulated according to the humidistat demand. A compatible humidistat shall be shipped loose for field installation (±3-4% RH). Controls VAV Control. A dual input, single output auto-selector shall be supplied to provide a single modulating output signal to the humidifier control cabinet (TCM or SCR modulating option must be specified). The auto-selector shall allow the use of a modulating wall mount humidistat and modulating duct high-limit humidistat (optional) to control critical variable air volume (VAV) air handling systems. The system shall automatically determine which of the two modulating signals is dominant and slowly reduces the humidifier output capacity, thus preventing over -saturation of the VAV system. Outdoor Air Temperature Setback. Provides automatic reduction of RH set-point to prevent condensation on windows during extreme cold weather. Air Flow Proving Switch. A diaphragm-operated air flow proving switch with adjustable control range of.05 W.C. to 12.0 W.C. shall be provided for field installation. Switch rating shall be 2.5 amps at 120V. Duct High-Limit. A high-limit humidistat shall be provided for duct installation. The high-limit shall be field-set to prevent over saturation within the supply duct. Drain Tempering Kit. DCT-927 self-actuated drain tempering kit The drain tempering kit is designed to provide drain and condensate water at a temperature of less than 140ºF. Condensate Pump. Used to lift condensate from the unit and dispersion tube. Separate 120V (3.1 amp) services required by others. SCR Modulation. Provides 0-100% power modulation of the heater outputs down to a one-second cycle rate. All heater sets have full SCR control. A compatible humidistat shall be shipped loose for field installation (±1-2% RH). Reference the Specification Sample for the humidifier base specification.