Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Similar documents
Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Zareba Unipoint controller

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Life Safety Network. Intelligent solutions for advanced requirements

Operating Instructions

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Searchpoint Optima Plus

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Zareba Metro Gas Detector

System 57. An advanced World of intelligent gas detection system management

Operating Instructions

Zareba Sensepoint Pro

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Sensepoint XCL Fixed Gas Detector

System 57. An advanced world of intelligent gas detection system management

Operating Instructions and Maintenance Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Touchpoint Pro Flexible Gas Control System

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Zareba System Overview

SPM Flex Chemcassette Tape-Based Gas Detector

Touchpoint Plus. A whole new control experience

Gas Detection. Touchpoint Plus. A whole new control experience

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Operating Instructions

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

XNX Universal Transmitter

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

Honeywell Analytics. Order List BW Clip & IntelliDoX

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

MeshGuard and MeshGuard Gamma

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

MeshGuard and MeshGuard Gamma

Touchpoint Plus. A whole new control experience

Searchpoint Optima Plus

Sieger Apex. Flexibility that meets your requirements

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

XNX Universal Transmitter

EC FX NH3. A new and improved approach to ammonia gas detection

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Fixed-Point Industrial Gas Detection

Technical Manual. Zareba Sensepoint Gas Detectors

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Product ProRAE Studio II Version V Operating Systems Windows 7(x86 and x64), Windows 10 Release Date December 2018

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

Fixed-Point Industrial Gas Detection

User Guide. MeshGuard Gamma

Combustible Gas Detection and Control System

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Oxygen (O2) Single-Point Gas Detection System

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Lumidor portable gas detection. Portable protection from hazardous gas

AreaRAE Pro Wireless, transportable area monitor Remote visibility on more threats than ever for an enhanced level of real-time situational

AreaRAE Plus Wireless, transportable area monitor Visibility on more gas threats than ever all in one versatile, easy-to-use device.

All users are recommended to update their existing ProRAE Guardian (PRG) software to v

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Danfoss gas detection unit Type GD Heavy Duty

Neotronics Impact & Impact Pro

GasDetector. Content In This Issue: from the Experts in Gas Detection. Honeywell Analytics Experts in Gas Detection

Two-Channel Gas Controller

Dräger PointGard 2100 Detection of toxic gases and vapours

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Sieger fixed gas detection. Fixed protection from hazardous gas

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Technical Manual. Touchpoint 4 4 Channel Gas Detector Controller

Analog Room Pressure Monitor RPC Series

Danfoss gas detection units

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Neotronics portable gas detection. Portable protection from hazardous gas

Toxic Gas Detection. Model F12. Toxic Gas Detection

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Technical Manual. Sensepoint XCD Gas Detector PRE-LAUNCH

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Operating Instructions

Danfoss gas detection units

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Transcription:

Unipoint ontroller The Unipoint, a simple DIN rail mounted controller

Unipoint DIN ontroller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment rooms Boiler houses HVA systems Analyser houses ar parks rane cabs Laboratories User Friendly Ultra-clear backlit display System status codes Built-in audiovisual alarms Intuitive menu system Simple pushbutton operation Remote accept, reset and inhibit inputs Easy to Install TS35 ( top hat ) DIN rail mounting Removable terminal connectors Easy access to all terminals Additional units clip together omprehensive Operation 3 wire mv bridge, 2 and 3-wire 4-20mA inputs D operation 3 x alarm relays 1 x system fault relay Field inhibit input (ma versions) Flexible Operation Fully user programmable scale, units and calibration Relays configurable as energised,, latching or, alarm relay on/off delay ompatible with a wide range of gas detectors The Unipoint is a simple DIN rail mounted controller offering integrators a flexible and low cost solution to incorporate flammable, toxic or Oxygen gas detection into their control systems. Unipoint can be easily installed into any plastic or metal enclosure for use indoor or outdoors and even in potentially explosive atmospheres. With the addition of one of the Honeywell Analytic s range of flammable, toxic or Oxygen detectors, systems may be configured to monitor gases in a wide range of applications from car parks and boiler houses to analyser shelters or crane cabs in offshore facilities. Two versions of Unipoint are available; one for mv bridge, catalytic bead type, flammable gas detector and the other for any 2 or 3 wire 4-20mA type gas detector. Each Unipoint is easily installed onto the DIN rail via a special socket (provided) that also interconnects power to adjacent units. With removable terminal connectors, individual Unipoint controllers can be easily changed without disturbing other devices. By clipping together multiple Unipoints small to medium sized monitoring solutions can be realised. Each unit includes built-in audiovisual alarms, three programmable alarm relays and a fault relay. Gas concentration and system status is displayed on the backlit LD and each controller is fully user programmable via an intuitive, push button operated menu system. onfiguration menus can be password protected to prevent unauthorised access. In addition remote inputs allow accept, reset and inhibit of alarms without the need to open the enclosure that the Unipoint is mounted in. Unipoint s uncomplicated design makes it ideal for applications where a simple method of integrating gas detectors into a 3rd party control system is required or as part of a small standalone gas detection solution. All Honeywell Analytics gas detectors and third party detectors may be used with Unipoint subject to overall power requirements.

Installation Details Dimensions Terminal Detail Installation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 + S - N R I N N N Detector Fault Reset Inhibit ommon Alarm 1 Alarm 2 Alarm 3 Max number of controllers on one power rail DIN rail Detector type Max number of controllers 3-wire mv 8 2-wire ma 8 3-wire ma 4 1" = 25.4mm wiring of power rail in parallel allows larger systems to be constructed Electrical Type of Detector Output to Detector Recommended Detector 2-wire 4-20mA 3-wire 4-20mA source ontroller Input (18-32VD)-1.5VD*, 30mA (max) Sense resistor 33 Ohms ontroller Input (18-32 VD)-1.5VD*, 0.5A (max) Sense resistor 33 Ohms 3-wire mv bridge 2.4-8.6V, 200mA constant current. Max cable loop resistance 28 Ohms. *The detector supply voltage is 1.5Vdc less than the supply to the controller Signalpoint or Sensepoint Toxic and Oxygen Sensepoint XD Signalpoint or Sensepoint Flammable ontroller Power onsumption Unipoint Version ontroller Status Relays Power Fault Alarm Normal operation, no faults, no alarms. Zero cable resistance Energised De-energised 2.4W 1 mv Normal operation, no faults, no alarms. Max loop cable resistance (28 ohms) Energised De-energised 3.6W 1 All alarms, no faults. Max cable resistance (28 ohms) Energised Energised 4.8W 1 ma Normal operation, no faults, no alarms. Inclusive of 2-wire signal loop current Energised De-energised 1.8W 2 All alarms, no faults. Inclusive of 2-wire signal loop current Energised Energised 3.0W 2 1 2 includes power to detector excludes power to 3 wire ma detector. All controllers with default configuration.

Technical Summary Gas Reading Event ode Power LED Fault/ Inhibit LED Alarm LED ancel Detector Wiring Schematics Gas Label Area Measurement Units Up Enter Down General Specification Use User Interface Operation Backlit Display Other Indication Termination The Unipoint controller provides integrators with a flexible and low cost solution to the many applications requiring flammable, toxic or Oxygen gas detection to be incorporated into their control systems. Unipoint is designed to use industry standard DIN rail allowing it to be easily installed into many different types of plastic or metal, indoor or outdoor, hazardous or non-hazardous area enclosures. It is designed for use with any mv flammable gas detector as well as any 2 or 3 wire 4-20mA gas detector (subject to overall power requirements). Two pushbuttons for normal operation of resetting alarms and initiating self diagnostic test of system. Four buttons for user programmable functions via intuitive menu Units of measure, digital gas reading and event code Ultra-bright steady / flashing LEDs subject to condition; alarm (red), power (green), fault (amber). In-built audible alarm 63db at 0.3 meters Easily accessible plug in screw type terminals. Terminals accept maximum wire diameter 1.5mm 2 (16 AWG) Environmental IP Rating Indoor, IP3x, to BS EN 60529:1992 (controller to be installed in suitable enclosure) Weight 225g (7.94oz) - ontroller only Operating Temp Range -10 to +55 / 14 F to 131 F (Performance approval -10 to +40 / 14 F to 104 F) Operating Humidity Range 10 to 90% RH (non condensing) Operating Pressure Range 90-110kPa Storage -25 to +60 / -13 F to +140 F, 20 to 80% RH (non condensing) Inputs Supply Nominal 24VD (18-32VD). Max power mv = 4.8W (including power to detector), ma= 3.0W (excluding power to 3 wire detector) Detector Type 3 wire mv bridge e.g. Sensepoint or Signalpoint flammable gas detectors 2 wire, 4-20mA, loop powered e.g. Sensepoint or Signalpoint toxic or Oxygen gas detectors 3 wire, 4-20mA, source output e.g. Sensepoint XD flammable, toxic and Oxygen gas detectors 3 wire mv (e.g. Signalpoint and Sensepoint Flammable) 2 wire ma (e.g. Signalpoint and Sensepoint Toxic and Oxygen) 3 wire ma (e.g Sensepoint XD all versions) Detector Supply Outputs Relays Rating Default Setting User onfigurable Options Approvals EM/RFI Electrical Safety Performance Other 2.4-8.6V, 200mA constant current. Maximum loop resistance: 28 Ohms Alarm 1 SPO / 3A, 240VA / 28VD Non-latching Energise on alarm Factory setting 10% FSD Alarm trip point Rising / falling Alarm on / off delay (0 to 900 seconds) EN50270 EN61010, UL61010b ATEX measuring function EN60079-29-1 SIRA10ATEX8243X E, TUV Input (18-32VD)-1.5VD, 30mA max Alarm 2 SPO / 3A, 240VA / 28VD Non-latching Energise on alarm Factory setting 25% FSD Alarm trip point Rising / falling Alarm on / off delay (0 to 900 seconds) Alarm 3 SPO / 3A, 240VA / 28VD Latching Energise on alarm Factory setting 50% FSD Alarm trip point Rising / falling Alarm on / off delay (0 to 900 seconds) Input (18-32VD)-1.5VD, 0.5A max Fault SPO / 3A, 240VA / 28VD Non-latching energised De-energise on fault / power loss

Ordering Information Ordering Information ontrollers Unipoint ontroller (mv input version) Unipoint ontroller (ma input version) 2306B2000 2306B1000 Spares Unipoint Terminal Block Plug (x2) Unipoint DIN rail socket kit Unipoint power connector kit 2306B3010 2306B3020 2306B3030 Required controller type reference: Detector Gas Type No. Wires ontroller Required Signalpoint Flammable 3 mv Toxic 2 ma Sensepoint Flammable 3 mv Toxic 2 ma Sensepoint XD Flammable 3 ma Toxic 3 ma Standard Supply Each Unipoint controller is supplied complete with DIN rail socket, power connector, gas type stickers and instruction manual. Shipping Details Shipping carton dimensions: H197mm (7.8") x W275mm (10.8") x D36mm (1.4") Approximate weight: 420g (14.8oz)

Our Product Range Fixed Gas Monitoring Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: ommercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites.» Detection of flammable, oxygen and toxic gases (including exotics)» Innovative use of 4 core sensing technologies paper tape, electrochemical cell, catalytic bead and infrared» apability to detect down to Parts Per Billion (ppb) or Percent by Volume (%v/v)» ost effective regulatory compliance solutions Portable Gas Monitoring When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include:» Detection of flammable, oxygen and toxic gases» Single gas personal monitors worn by the individual» Multi-gas portable gas monitors used for confined space entry and regulatory compliance» Multi-gas transportable monitors used for temporary protection of area during site construction and maintenance activities Technical Services At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer:» Full technical support» Expert team on hand to answer questions and queries» Fully equipped workshops to ensure quick turnaround on repairs» omprehensive service engineer network» Training on product use and maintenance» Mobile calibration service» ustomised programmes of preventative/corrective maintenance» Extended warranties on products Find out more www.honeywellanalytics.com ontact Honeywell Analytics: Europe, Middle East, Africa, India Life Safety Distribution AG Weiherallee 11a H-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Technical Americas Services EMEAI: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea Tel: +82 (0)2 6909 0300 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Unipoint_DS0344_V4_EMEAI 05/11 2011 Honeywell Analytics 11138