- CAC. Commercial Air Conditioning Electrical Consumption Economizer

Similar documents
prestige Control Application Supplement WARNING

Smart ways to save energy IntelliCon INSTALLATION MANUAL

- Data Brochure Steam Control 279

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Medium Mass Boilers. Maxim Power VT

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

OPERATING INSTRUCTIONS

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

DAY/TIME Button: Selects hour, minute and day setting.

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

prestige Control Application Supplement - Type 5 MCBA WARNING

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

prestige Control Application Supplement - TriMax

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Installer Guide. WARNING Important Safety Information. 1 Specifications

Hydronic Mechanical Panels

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Heating system service plans that provide total peace of mind.

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

KE2 EvaporatorEfficiency Theory of Operation

Installer Guide. WARNING Important Safety Information. 1 Specifications

DAY/TIME Button: Selects hour, minute and day setting.

AND WORRY-FREE PERFORMANCE

Reinventing Energy Efficiency

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HIGH EFFICIENCY COMMERCIAL BOILERS

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

HIGH-EFFICIENCY FURNACES

HEATING SOLUTIONS. endless. heating solutions HOME HEATING SOLUTIONS

Comfort Solutions Puron Perfect Heat Perfect Humidity Perfect Heat Perfect Humidity Hybrid Heat Systems Zone Perfect Plus Energy Star

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Comfort Solutions Puron Perfect Heat Perfect Humidity Perfect Heat Perfect Humidity Hybrid Heat Systems Zone Perfect Plus Energy Star

- Data Brochure Universal Reset Module 422

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

Model 60200FR Gas Primary Control Data Sheet

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

Upgrades in Performance and Style

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Operator: Save these instructions for future use!

Sustainable Techniques in Refrigerated Space

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Heating Colorado Homes

Project Name: Location: Engineer: Contractor: I. GENERAL

F-Series Tower Drying

prestige Control Application Supplement - Type 5 MCBA WARNING

THERMOSTATS 100-Series NON-PROGRAMMABLE UHC-TST101GESS UHC-TST102HPMS UHC-TST103UNMS

- Essay Control Functions and Benefits

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

USERS MANUAL FOR GAS BOILERS

WARNING Important Safety Information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

YORK AFFINITY VARIABLE CAPACITY RESIDENTIAL SYSTEMS

Warmth and Comfort. cy and savings.

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Hot Water Makers. Efficiency at its Best

Wired Solutions Wired Heating Control Products

VS Series. Variable Speed Rotary Screw Compressors

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

National Grid s Direct Install Program for Commercial Customers

HEATING SOLUTIONS. endless. heating solutions HOME HEATING SOLUTIONS

Programmable Electronic Thermostat

50A Integrated Furnace Control

Neomitis Boiler Plus Compliant Room Thermostats

Advanced Facility Air-Management Technology

Air to water Heat Pump System

Indirect-Fired Water Heaters. BoilerMate Classic & Champion Series

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

- Data Brochure Universal Reset Module 423

It won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater

High Efficiency Commercial Gas Water Heaters

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification RHC TST 101 GE MS

Smart vs. Proprietary Thermostat Webinar Which is best for your customers? Session #1 5/3/ am CST Session #2 5/11/ pm CST

COLEMAN ECHELON VARIABLE CAPACITY RESIDENTIAL SYSTEMS

Operator: Save these instructions for future use!

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com

Heat Pumps COMFORT NEED IT. When You

SMART THERMOSTATS INCREASE YOUR I.Q.

USER'S INFORMATION MANUAL

Quickheat 30 weather compensated boiler control

The Digital Scroll Dryer

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

PROPANE IS YOUR WHOLE HOME ENERGY UPGRADE RESIDENTIAL APPLIANCE BROCHURE

Intelligent Heating for Your Home

Transcription:

A smart way to save on your commercial air conditioning costs. IntelliCon - CAC Commercial Air Conditioning Electrical Consumption Economizer Intellidyne s IntelliCon -CAC typically reduces Commercial Air Conditioning electric consumption by 10% to 20% or more. The IntelliCon-CAC is a microprocessor-based, UL listed, electronic control that uses intelligent Dynamic Cycle Management (DCM) technology to automatically adjust the compressor cycles to achieve the greatest efficiency and reduced electrical usage, while assuring consistent temperature levels. IntelliCon-CAC is maintenance free, easy to install by a qualified installer, and is guaranteed to save energy. Features Dynamic Cycle Management (DCM) technology reduces air conditioning electric consumption typically 10% to 20% UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control Illuminated LCD display shows run time hours, economizing hours, operating modes and system diagnostics For systems 5 tons or larger Protects compressor against momentary power outages and short cycling Simple installation by a qualified HVAC/R installer No programming or follow-up visits required Maximum year-round efficiency Reduces maintenance and extends compressor life Fail-safe operation Guaranteed to save energy 15-year replacement warranty for breakdowns or defects

IntelliCon - CAC Commercial Air Conditioning Electrical Consumption Economizer Specifications Mounting: In any position via molded-in 1/2 Electrical Fitting Size: 4 H x 4 W x 2 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. Sizing of air conditioning systems is based upon a number of factors. When any of the design considerations are not met, the air conditioning system can become relatively oversized for the cooling load and thus less efficient. Intellidyne s patented process uses Dynamic Cycle Management (DCM) technology to determine the cooling demand and thermal characteristics of the entire air conditioning system by analyzing the compressor s cycle pattern, and dynamically modifies that cycle pattern to provide the required amount of cooling in the most efficient manner. This is accomplished in real-time by delaying the start of the next compressor on cycle by an amount determined by the cooling demand analysis. These new patterns also result in less frequent and more efficient compressor cycles. IntelliCon -CAC electrically augments the existing controls, and will not cause the compressor to run unless the existing thermostat is calling for it to do so. Just as computer control has increased the gas mileage of automobiles, IntelliCon-CAC improves the electrical efficiency of air conditioning systems, by supplementing the antiquated on/off action of the thermostat (even a smart one) with the analysis and control capabilities of a computer. Field-testing has demonstrated that IntelliCon s intelligent modification of compressor cycling with DCM Technology will lead to significant electrical energy savings. IntelliCon s innovative and intelligent algorithms have proven electrical savings; not only on properly sized and operating systems, but also on units that were undersized or those that had not been properly maintained. IntelliCon-CAC works in conjunction with the existing thermostat and will not void the compressor manufacturer s warranty. An additional feature of the IntelliCon-CAC is the accepted industry practice of compressor anti-short-cycling control. Installation by a qualified HVAC/R service technician is recommended. IntelliCon-CAC does not require any programming, adjustments, or maintenance. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200906

A smart way to save on your commercial steam heating costs. IntelliCon - CHS (HP) Commercial Steam Heating System Fuel Economizer IntelliCon -CHS is a microprocessor-based, saving control for commercial steam heating systems. fuel- IntelliCon-CHS reduces: fuel consumption, wear on parts, flue emissions and electrical usage when installed on any new or existing gas or oil burner. IntelliCon-CHS uses intelligent Dynamic Cycle Management (DCM) technology to save energy by adjusting the burner run pattern to match the system s heat load. Features For systems with ratings above 2.5 million BTU CHS for systems with operating pressures > 2 psi and < 30 psi CHS-HP for systems with operating pressures > 30 psi and < 145 psi Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures Dynamic Cycle Management (DCM) technology reduces fuel consumption average savings 14.2% Short payback period less than 18 months UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control Easily installed plug-in sensor(s) (includes 1 required sensor) Simple installation by qualified heating professional Fail-safe operation Easily programed for maximum savings Reduces maintenance and extends boiler life Guaranteed to reduce fuel consumption by 10% 15 year limited warranty against breakdowns or defects

IntelliCon - CHS (HP) Commercial Steam Heating System Fuel Economizer Specifications Mounting: On Vertical Surface via 3-point Mounting System Size: 7 1/2 H x 9 1/2 W x 4 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. Any heating system must be able to provide acceptable comfort at the lowest anticipated outdoor temperature. In the U.S. and abroad, most commercial boilers have a heat capacity between 1.5 to 2 times larger than that needed to maintain the facility s temperature on those extreme days. Due to this over-sizing of the boiler, the burner will cycle on and off continuously to maintain the desired steam pressure. Using our patented Dynamic Cycle Management (DCM) Technology, IntelliCon -CHS increases system efficiency. Thus, the heating system uses less fuel to generate the required amount of heat. This is done by dynamically changing the pressure-controller s effective dead-band based upon the measured heating load. This causes the average steam pressure to be varied (depending upon the measured load), and is accomplished by extending the burner s off-time. Extending the off-time also results in longer, more efficient burn cycles and reduces burner on/off time. Just as computer control has increased the gas mileage of automobiles, IntelliCon-CHS with DCM Technology improves the fuel utilization of heating systems, by supplementing the antiquated on/off control action of the pressure-controller with the analysis and control capabilities of a microprocessor. Facility engineers will appreciate the LCD, which displays useful information relative to the unit s status, steam pressure fuel savings and system runtime, which can be useful for system diagnostics and maintenance. IntelliCon-CHS typically reduces fuel consumption 10% to 20% and decreases burner cycling by 30% or more. Installation is simple for a qualified heating technician. Programming is easily accomplished during installation to maximize the fuel savings of the specific system. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902

A smart way to save on your commercial heating costs. IntelliCon - LCS Light Commercial Steam Heating System Fuel Economizer IntelliCon -LCS is a microprocessor-based, fuel-saving control for light-commercial steam heating systems. IntelliCon-LCS reduces fuel consumption, wear on parts, flue emissions and electrical usage, when installed on any new or existing gas or oil burner. IntelliCon-LCS uses intelligent Dynamic Cycle Management (DCM) Technology to save energy by adjusting the burner run pattern to match the system s heat load. Its action is similar to the industry-accepted method of outdoor-air temperature reset control, but does not require an outdoor-air temperature sensor or the need to profile the building in order to adjust the reset control properly. IntelliCon-LCS determines the heat load by using an easily installed pressure sensor that monitors the boiler s steam-pressure and the rate that this pressure is changing. Features For commercial systems rated up to 2.5 million BTU Dynamic Cycle Management (DCM) Technology reduces fuel consumption typically 10% to 20% Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control Easily installed plug-in sensor(s) (includes 1 required sensor) Simple installation by qualified installer Easily programmed for maximum savings Maximum year-round efficiency Reduces maintenance and extends boiler life Fail-safe operation Guaranteed to save energy 15-year replacement warranty for breakdowns or defects

IntelliCon - LCS Light Commercial Steam Heating System Fuel Economizer Specifications Mounting: In any position via molded-on 1/2 Electrical Fitting Size: 4 H x 4 W x 2 1/2 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. Any heating system must be able to provide acceptable comfort at the lowest anticipated outdoor temperature. In the U.S. and abroad, most light commercial boilers have a heat capacity between 1.5 to 2 times larger than that needed to maintain the facility s temperature on those extreme days. Due to this over-sizing of the boiler, the burner will cycle on and off continuously to maintain the desired steam pressure. Using our intelligent Dynamic Cycle Management (DCM) Technology, IntelliCon -LCS increases system efficiency. Thus, the heating system uses less fuel to generate the required amount of heat. This is done by dynamically changing the pressure-controller s effective dead-band based upon the measured heating load. This causes the average steam pressure to be varied (depending upon the measured load), and is accomplished by extending the burner s off-time. Extending the off-time also results in longer, more efficient burn cycles and reduces burner on/off time. Just as computer control has increased the gas mileage of automobiles, IntelliCon-LCS with DCM Technology improves the fuel utilization of heating systems, by supplementing the antiquated on/off control action of the pressure-controller with the analysis and control capabilities of a computer. Service personnel will appreciate the LCD readout, which displays useful information relative to the unit s status, steam pressure and domestic hot-water temperature (if the optional sensor is installed), which can be useful for system diagnostics and maintenance. IntelliCon-LCS typically reduces fuel consumption 10% to 20% and decreases burner cycling by 30% or more. Initial installation programming is easily done by a qualified service technician by following the on screen directions. After installation, IntelliCon-LCS requires no maintenance. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902

A smart way to save on your commercial hot water heating costs. IntelliCon - CHW Commercial Hot Water Heating System Fuel Economizer IntelliCon -CHW is a microprocessor-based fuel-saving control for commercial hot-water heating systems. IntelliCon-CHW reduces: fuel consumption, wear on parts, flue emissions and electrical usage, when installed on any new or existing gas or oil burner. IntelliCon-CHW uses intelligent Dynamic Cycle Management (DCM) technology to save energy by adjusting the burner run pattern to match the system s heat load. Features For systems with ratings above 2.5 million BTU Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures Dynamic Cycle Management (DCM) technology reduces fuel consumption average savings 15.6% Short payback period less than 18 months UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control Easily installed plug-in sensor(s) (includes 1 required sensor) Simple installation by qualified heating professional Fail-safe operation Easily programed for maximum savings Reduces maintenance and extends boiler life Guaranteed to reduce fuel consumption by 10% 15 year limited warranty against breakdowns or defects

IntelliCon - CHW Commercial Hot Water Heating System Fuel Economizer Specifications Mounting: On Vertical Surface via 3-point Mounting System Size: 7 1/2"H x 9 1/2"W x 4"D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. A heating system must be able to provide acceptable comfort at the lowest anticipated outdoor temperature. In the U.S. and abroad, most commercial boilers have a heating capacity between 1.5 to 2 times larger than that needed to maintain the facility s temperature on those extreme days. Due to this over-sizing of the boiler, the burner will cycle on and off continuously. Even on boilers with proportional controls, once the heating load goes below the burner s low-fire point, the burner will cycle on and off to prevent overheating of the system water. IntelliCon -CHW uses Dynamic Cycle Management (DCM) Technology to save energy by adjusting the burner run pattern to match the system s heat load. This action is similar to the industry-accepted method of outdoor-air temperature reset control, but does not require an outdoor-air temperature sensor or the need to profile the building in order to adjust the reset control properly. IntelliCon-CHW determines the heat load in real time by using an easily installed strap-on temperature sensor that monitors the boiler s out-flow water temperature and the rate this temperature is changing. By using our patented DCM Technology, IntelliCon-CHW increases system efficiency. Thus, the heating system uses less fuel to generate the required amount of heat. This is done by dynamically changing the aquastat s effective dead-band based upon the measured heating load. This causes the average water temperature to vary (depending upon the measured load), and is accomplished by extending the burner s off-time. Extending the off-time also results in longer, more efficient burn cycles and reduces burner on/off time. Just as computer controls have increased the gas mileage of automobiles, IntelliCon-CHW improves the fuel utilization of heating systems, by supplementing the antiquated on/off control action of the aquastat with the analysis and control capabilities of a computer. Facility engineers will appreciate the illuminated LCD readout, displaying the fuel consumption savings and other useful information relative to the unit s status, system temperatures and diagnostics, all of which are useful during routine system maintenance. IntelliCon-CHW typically reduces fuel consumption 10% to 20% and decreases burner cycling by 30% or more. Installation is simple for a qualified heating technician. The IntelliCon-CHW s small 7 1/2 H x 9 1/2 W x 4 D size allows it to be installed almost anywhere. After installation, IntelliCon-CHW does not require any maintenance or seasonal programming. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902

A smart way to save on your commercial hot water heating costs. IntelliCon - LCH Light Commercial Hot Water Heating System Fuel Economizer IntelliCon -LCH is a microprocessor-based, fuel-saving control for light-commercial hot-water (hydronic) heating systems. IntelliCon-LCH reduces fuel consumption, wear on parts, flue emissions and electrical usage, when installed on any new or existing gas or oil burner. IntelliCon-LCH uses intelligent Dynamic Cycle Management (DCM) Technology to save energy by adjusting the burner run pattern to match the system s heat load. Its action is similar to the industry-accepted method of outdoor-air temperature reset control, but does not require an outdoor-air temperature sensor or the need to profile the building in order to adjust the reset control properly. IntelliCon-LCH determines the heat load by using an easily installed strap-on temperature sensor that monitors the boiler s out-flow water temperature and the rate that this temperature is changing. Features For commercial systems rated up to 2.5 million BTU Dynamic Cycle Management (DCM) Technology reduces fuel consumption typically 10% to 20% Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control Easily installed plug-in sensor(s) (includes 1 required sensor) Simple installation by qualified installer Easily programmed for maximum savings Maximum year-round efficiency Reduces maintenance and extends boiler life Fail-safe operation Guaranteed to save energy 15-year replacement warranty for breakdowns or defects

IntelliCon - LCH Light Commercial Hot Water Heating System Fuel Economizer Specifications Mounting: In any position via molded-on 1/2 Electrical Fitting Size: 4 H x 4 W x 2 1/2 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. Any heating system must be able to provide acceptable comfort at the lowest anticipated outdoor temperatures. In the U.S. and abroad, most light commercial boilers have a heat capacity between 1.5 to 2 times larger than that needed to maintain the facility s temperature on those extreme days. Due to this over-sizing of the boiler, the burner will cycle on and off repeatedly to prevent overheating of the system water. Using our intelligent Dynamic Cycle Management (DCM) Technology, IntelliCon -LCH increases system efficiency. Thus, the heating system uses less fuel to generate the required amount of heat. This is done by dynamically changing the aquastat s effective dead-band based upon the measured heating load. This causes the average water temperature to be varied (depending upon the measured load), and is accomplished by extending the burner s off-time. Extending the off-time also results in longer, more efficient burn cycles and reduces burner on/off time. Just as computer control has increased the gas mileage of automobiles, IntelliCon-LCH with DCM Technology improves the fuel utilization of heating systems by supplementing the antiquated on/off control action of the aquastat with the analysis and control capabilities of a computer. Service personnel will appreciate the illuminated LCD readout, which displays the fuel consumption savings and other useful information relative to the unit s status, system temperatures and diagnostics, all of which are useful during routine system maintenance.. IntelliCon-LCH typically reduces fuel consumption 10% to 20% and decreases burner cycling by 30% or more. Initial installation programming is easily done by a qualified service technician by following the on screen directions. After installation, IntelliCon-LCH requires no maintenance. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902

A smart way to save on your forced-air heating costs. IntelliCon - FA Forced-Air Heating System Fuel Economizer IntelliCon -FA is a microprocessor-based, fuel-saving control for forced-air heating systems. IntelliCon-FA, through the use of our intelligent Dynamic Cycle Management (DCM) Technology, reduces: fuel consumption, wear and tear on parts, flue emissions and electrical usage, when installed on any new or existing forced-air furnace. Features Dynamic Cycle Management (DCM) Technology is guaranteed to reduce fuel consumption typically 10% to 20% or more Saves fuel without replacing or upgrading costly system components and without violating manufacturers warranties Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures Saves energy without sacrificing comfort Short payback period typically 4 to 18 months Field-tested and validated energy saving control Works with any thermostat including setback and multi-zone thermostats UL listed, Energy Management Equipment State-of-the-art microprocessorbased control Easily installed plug-in sensor(s) (includes 1 required sensor) Simple installation by qualified installer Fail-safe operation requires no programming or follow-up visits Maximum efficiency year-round Reduces maintenance and extends furnace life 15-year replacement warranty for breakdowns or defects

IntelliCon - FA Forced-Air Heating System Fuel Economizer Specifications Mounting: In any position via molded-on 1/2 Electrical Fitting Size: 4 H x 4 W x 2 1/2 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. A heating system must keep its occupants comfortably warm at the coldest anticipated outdoor temperature. Most forced-air heating systems in the U.S. and abroad are between 50% and 100% larger than necessary for maintaining a comfortable temperature on most days when the temperature is not as low as those extreme days. This excess capacity causes the burner to cycle on and off continuously to prevent the furnace from overheating. Even on furnaces with programmable setback thermostats or multi-zone controls, the burner cycling is not optimized. This burner cycling pattern wastes fuel. IntelliCon -FA saves energy with our Dynamic Cycle Management (DCM) Technology by adjusting the burner run pattern to match the system s heat load. IntelliCon-FA analyzes the system s load, or demand for heat, by monitoring the out-flow air, or discharge-air, temperature as it is blown out of the furnace into the structure. Optionally, the return-air can be monitored as well for additional energy savings. The absolute temperature value of the air in-flow and outflow, coupled with the rate that the temperature is changing, is indicative of the load placed on the heating system. In addition, IntelliCon-FA measures and records how many times the burner is turned on and off and the duration of those burner cycles. IntelliCon-FA analyzes how fast heat is being lost in the system and, in turn, in the space. Using this information, the optimum running cycle for maintaining the desired heating level is calculated. IntelliCon-FA then intercedes and changes the way the burner is cycled. As a result, less fuel is consumed in delivering the same amount of heating comfort. Just as dynamic computer control has increased the gas mileage of automobiles: IntelliCon-FA with DCM Technology dynamically improves the fuel utilization of forced-air heating systems. By supplementing the simplistic on/off control action of the thermostat with the analysis and control capabilities of a real-time computer, owners can enjoy maximum energy savings with no sacrifice in comfort and with no adjustments required ever. The Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures. IntelliCon-FA typically reduces fuel consumption 10% to 20%. Installation by a qualified service technician takes about 60-90 minutes and does not require any programming or adjustments. The IntelliCon-FA s small 4 H x 4 W x 2 1/2 D size allows it to be installed almost anywhere. After installation, IntelliCon-FA does not require any maintenance and will not violate manufacturers warranties. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902

A smart way to save on your commercial refrigeration costs. IntelliCon - RU Commercial Refrigeration Unit Electrical Consumption Economizer The IntelliCon -RU will reduce electric consumption typically 10% to 20% when installed on commercial refrigeration/freezer (refrigeration) systems. IntelliCon-RU using intelligent Dynamic Cycle Management (DCM) Technology represents a major advancement in refrigeration system energy-saving technology, unsurpassed in today s commercial refrigeration marketplace. IntelliCon-RU is easily installed by a qualified installer, maintenance free and guaranteed to save energy. Features Dynamic Cycle Management (DCM) Technology reduces air conditioning electric consumption typically 10% to 20% UL listed, Energy Management Equipment Increased savings without replacing or upgrading costly system components State-of-the-art microprocessorbased control LED indicators show operating modes Protects compressor against momentary power outages and short cycling Simple installation by a qualified HVAC/R installer No programming or follow-up visits required Maximum year-round efficiency Reduces maintenance and extends compressor life Fail-safe operation Guaranteed to save energy 15-year replacement warranty for breakdowns or defects

IntelliCon - RU Commercial Refrigeration Unit Electrical Consumption Economizer Specifications Mounting: Any position via molded-on 1/2 Electrical Fitting Size: 4 H x 4 W x 2 1/2 D Operating Humidity: 5% - 95% Non-Condensing Operating Temperature Range: -10 F - +120 F Power Input: 24/115/220 VAC @ 5W Control Circuit: 24 VAC/DC, 115/220 VAC Relay Contact: 10A @ 220VAC General Purpose UL Listed, Energy Management Equipment Made in U.S.A. The IntelliCon -RU is a microprocessor-based, UL listed, electronic control that automatically adjusts the compressor cycles to achieve the greatest efficiency and reduced electrical usage. The sizing of refrigeration systems is based upon a number of factors. When any of the design considerations are not met, the refrigeration system can become oversized for the load and thus less efficient. Intellidyne s intelligent Dynamic Cycle Management (DCM) Technology analyzes the demands and thermal characteristics of the entire refrigeration system, and dynamically modifies the compressor cycle pattern. These new patterns result in less frequent and more efficient compressor cycles. Just as computer control has increased the gas mileage of automobiles, IntelliCon-RU improves the electrical efficiency of refrigeration systems, by supplementing the antiquated on/off action of the thermostat or pressuretrol with the analysis and control capabilities of a computer. The IntelliCon DCM Technology intelligent modification of compressor cycling will result in significant electrical energy savings. IntelliCon s innovative and intelligent algorithms have field proven electrical savings not only on properly sized and operating systems, but also on units that were undersized or those that had not been properly maintained. The IntelliCon-RU works in conjunction with the existing temperature controls and will not void the compressor manufacturer s warranty. An additional feature of the IntelliCon-RU is the accepted industry practice of compressor anti-short-cycling control. Installation by a qualified HVAC/R service technician is recommended. The IntelliCon-RU does not require any programming, adjustments or maintenance. 2009 Intellidyne and the IntelliCon logo are registered trademarks of Intellidyne LLC. The Energy Star logo is a registered trademark courtesy of Energy Star Corporation. All rights reserved. 200902