B & W Engineering Laboratories, Inc. P.O. Box Memphis, Tennessee (901)

Similar documents
CHAPTER 8 SLOPE STABILITY ANALYSIS

Advanced Foundation Engineering. Soil Exploration

APPENDIX E: UC Berkeley Laboratory Testing and ILIT In-Situ Field Vane Shear Testing

Rapid Drawdown with Multi-Stage

1 SITE AND PROJECT DESCRIPTION

SITE AND PROJECT DESCRIPTION

Sydney Road Reclaimed Water Main, Plant City, Florida. Prepared for: Jones Edmunds & Associates, Inc.

APPENDIX E COMPACTION CHARACTERISTICS AND EQUIPMENT

Pontiac Trail 1" = 80' B-1 B-2 B-3 B-4 B-5. to WB S23 C SB U M 14. a c Trl

Geotechnical Exploration and Evaluation Report

The City of Winnipeg Bid Opportunity No GEOTECHNICAL REPORT - TEST HOLE LOGS

Slope Stability in Harris County

Test Pit Observation Report. Albertville Business Park 67th Street to 70th Street NE Albertville, Minnesota. Prepared for.

Gary Person, Foundation Engineer Geotechnical Engineering Section

M. Block & Associates Ltd.

EAT 212 SOIL MECHANICS

Fine Coal Refuse 25 Years of Field and Laboratory Testing Data and Correlations

THE ROLE OF SUCTION IN THE PERFORMANCE OF CLAY FILL RONALD F. REED, P.E. 1 KUNDAN K. PANDEY, P.E. 2

JULY 23, 2018 PROJECT REPORT OF GEOTECHNICAL EXPLORATIONS CASS GILBERT MEMORIAL PARK SOLAR GARDEN CAPITOL COMPLEX ST.

-AIHL NOISE UNIFIED SOIL CLASSIFICATION SYSTEM. Aqx. R CORPS OF ENGINEERS, U. S. ARMY APPENDIX A

Geotechnical Exploration and Evaluation Report Revision No. 01

Technical Manual for Dam Owners Impact of Plants on Earthen Dams FEMA 534

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Road Soil. Curtis F. Berthelot Ph.D., P.Eng. Department of Civil Engineering. Road Soil Introduction

REFERENCE NO S066 JUNE 2017

V. EROSION CONTROL. -Drainage swales separation -Under rip-rap protected -Under rip-rap unprotected

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

Numerical Analysis of Leakage through Geomembrane Lining Systems for Dams

Strength of Materials for Embankment Dams

Reference No S053 MARCH 2012

NOT PROTECTIVELY MARKED SUB-APPENDIX A2: SOIL ANALYTICAL SUITES

Transition of soil strength during suction pile retrieval

Bearing Capacity Theory. Bearing Capacity

Compaction. Compaction purposes and processes. Compaction as a construction process

Assessment of Geotextile Reinforced Embankment on Soft Clay Soil

Embankment Slope Stability Analysis of Dwight Mission Mine Site Reclamation Project

04.SOIL MOISTURE MEASUREMENT

Evaluation of undrained shear strength of soft New Orleans clay using piezocone

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

APPENDIX D. Slope Stability Analysis Results for Soil and Overburden Storage Mounds

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Draft Rhode Island Stormwater Design and Installation Standards Manual

STATEMENT OF PHYSICAL CHARACTERISTICS AND AGRICULTURAL LAND CLASSIFICATION

Soil Mechanics Prof. B.V.S. Viswanadham Department of Civil Engineering Indian Institute of Technology, Bombay Lecture - 11 Compaction of Soils - 1

Reference No S082

III.DRAINAGE. This section describes the use of geotextiles in underdrains for two different field conditions:

Slope stability assessment

TECHNICAL REPORT STANDARD PAGE

Study on Effect of Water on Stability or Instability of the Earth Slopes

SOIL BORING LOCATION SKETCH GEOTECHNICAL EVALUATION ST. CROIX TRAVEL AND INFO CENTER POND 1-94, WEST OF STAGECOACH TRAIL LAKELAND, MINNESOTA

EMERGENCY ACTION PLAN

Lightweight aggregates in Civil Engineering applications. Arnstein Watn Senior Scientist, SINTEF

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

Soil Strength and Slope Stability

STATEMENT OF PHYSICAL CHARACTERISTICS AND AGRICULTURAL LAND CLASSIFICATION WITTON PARK, COUNTY DURHAM PROPOSED QUARRY EXTENSION DECEMBER 1992

THE PERFORMANCE OF STRENGTHENING SLOPE USING SHOTCRETE AND ANCHOR BY FINITE ELEMENT METHOD (FEM)

PILE FOUNDATIONS CONTENTS: 1.0 Introduction. 1.1 Choice of pile type Driven (displacement) piles Bored (replacement) piles. 2.

GLOSSARY OF GROUND IMPROVEMENT VOCABULARY

2018 Annual Landfill Inspection Report

The Effects of Woody Vegetation on Levees

Full Scale Model Test of Soil Reinforcement on Soft Soil Deposition with Inclined Timber Pile

Introduction. A soil is an earth concrete. Composition of a soil

MARQUETTE UNIVERSITY DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING LAB REPORT FORMAT

Developing Dam Operations & Maintenance Manuals

Swelling Treatment By Using Sand for Tamia Swelling Soil

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

Subsoil conditions are examined using test borings, provided by soil engineer (geotechnical).

2.1.4 Roof Downspout Rain Gardens

Part 5. Environmental Protection Overlay District Regulations

Peatland Action Guidance for land managers. Installing peat dams. Updated May 2015

Finite Element Methods against Limit Equilibrium Approaches for Slope Stability Analysis

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Advanced Foundation Engineering. Introduction

APPLICATIONS IN FILTRATION AND DRAINAGE & EROSION CONTROL

POND Construction. Perry L. Oakes, PE State Conservation Engineer Natural Resources Conservation Service

Zoning Ordinance Article 3

Subject Name: RESERVOIR AND FARM POND DESIGN (2+1) CONTENTS

An Experimental Study on Variation of Shear Strength for Layered Soils

4 Slope Stabilization Using EPS Geofoam at Route 23A

SR 28, Washoe County, from Miles North of. East Lakeshore Boulevard, Incline Village, to. NV/CA Stateline

Influence of Long-Term Increasing Trend of Maximum Hourly Rainfall on Slope Stability in Forested Area of Aso, Japan

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS

Vineyard Variability Due To Differences in Soil. Ann Tan UC Davis

Load-Carrying Capacity of Stone Column Encased with Geotextile. Anil Kumar Sahu 1 and Ishan Shankar 2

Project: Developer/Designer: Reviewer: I. Narrative: 1. Project Description: Describes the nature and purpose of the land disturbing activity.

URBAN SOILS & SEATTLE EXAMPLES

THE ULTIMATE SKIN RESISTANCE OF CONCRETE PILE IN PARTIALLY SATURATED COHESIVE SOIL BY MODIFIED Β METHOD

The University of Iowa Department of Civil & Environmental Engineering SOIL MECHANICS 53:030 Final Examination 2 Hours, 200 points

Forterra- Kimbolton Red Multi (sample ordered but awaited)

Minnesota Department of Transportation MEMO Office of Materials Mailstop Gervais Avenue Maplewood, MN 55109

Soil Stabilization by Using Fly Ash

I N D U S T R I A L Y A R D S

North Branch of Cypress Creek Ecological Restoration: A Comprehensive Approach to Stream Restoration

Shear Strength of Soils

Former Truck Maintenance Garage Soil Remediation Report

11 March 2015 Our Ref: /356573

Merrill Zwanka Geotechnical Materials Engineer SCDOT Research and Materials Lab February Definitions Sampling and Testing Classification

[Gupta* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

Transcription:

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 SLOPE STABILITY ANALYSIS WOODLAND LAKE DAM EUDORA, MISSISSIPPI

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 03 June 2016 Job No. 8654 Serial No. D-2208 Ms. Shirley Harris, President Woodland Lake Homeowners Association (662) 429-4085 cell (870) 995-1715 sbharris20@aol.com Ref: Slope Stability Analysis Woodland Lake Dam Eudora, Mississippi Dear Shirley: The purpose of this investigation was to provide slope stability analyses for the referenced earth dam to determine the factors of safety for various anticipated loading conditions, with particular interest in a rapid drawdown condition that could develop should the Lake Delta Crest dam that forms the tailwater of the referenced dam suddenly fail. The investigation included completion of three test borings at the crest and on the land side slope of the earth dam, completion of physical properties laboratory analyses on the samples obtained, and performance of engineering analyses of the resulting field and laboratory data. The services of Jones-Davis and Associates (JDA) were utilized for determination of the elevations along the section that was analyzed, as represented as Section C on Figures 1-C and 1-D, including elevations of the dam embankment and lake bottoms. Groundwater profiles through Sections A and B, illustrated on Figures 1-A and 1-B, were utilized in the analyses, with these sections being on each side of Section C, as illustrated. Section Profiles The subject earth dam has a crest width of about ten feet. The land side (downstream) slope of the earth dam was previously 1 (vertical) to about 3.5 (horizontal), but the crest has since been raised about four feet to provide about seven feet of freeboard under normal pool conditions, effectively steepening the upper portion of the land side slope to 1 (V) to 2 (H). The lower portion of the land side slope remains about 1 (V) to 3.5 H), to the toe, then flattens to about a 5 percent slope to the Lake Delta Crest water line, steepening slightly beneath the pool elevation. Lake Delta Crest is only about seven feet deep at a distance of about 200 feet from the lake s edge at Section C. The upstream slope of the Woodland Lake dam is not believed to have been significantly effected by the raising of its crest, although historic profiles beneath the pool are not available. Based on the JDA measurements, the upstream slope varies from about 1 (V) to 2 (H) to 1 (V) to 3.5 (H), and Woodland Lake is about thirty feet deep. 1

Seepage Conditions As described in the accompanying Seepage/Piezometer report, at this time there is no evidence of excessive seepage through the Woodland Lake earth dam. Embankment Soil Conditions Three test borings were completed as a part of this investigation; boring locations are illustrated on Figure Numbers 1-C and 1-D. The borings were drilled using hand augering equipment, and were terminated at depths ranging from twenty to forty feet below the existing ground surface. The boreholes were backfilled with bentonite after completion. Soil samples obtained directly from the hand auger were logged, labeled, and placed in moisture-proof containers in the field. Dynamic Cone Penetration tests were performed at regular intervals in each of the borings. The Dynamic Cone Penetration test consists of driving a conical steel penetrometer 7.25 inches by means of a fifteen pound weight dropping twenty inches. The initial 2.0 inches of this movement properly seats the penetrometer in the undisturbed soil at the bottom of the borehole. The average number of blows required to move the cone the remaining three 1.75 inch increments is recorded as the Dynamic Cone Penetration Test Blow Count. The blow counts are converted to the N-values shown on the boring log which are statistically consistent with N-Values of the Standard Penetration Test. Visual classification and natural water content determinations were performed in the laboratory on all soil samples retrieved from the borings; results are shown on the boring logs presented in Appendix A. Soil classification tests were also performed on representative soil samples; results are presented in Appendix B. The soils encountered consist of soft to stiff silty clays and clayey silts. As would be expected, the soils encountered beneath the groundwater surface are saturated and subsequently softened. Cohesion values of the soils encountered range from as low as about 250 pounds per square foot to over 1000 pounds per square foot, averaging about 500 pounds per square foot. The saturated clayey silts are on the lower end of this range, however such soils exhibit some strength from friction; the estimated friction angle of the softer clayey silts encountered in the test borings is about 25 to 26 degrees, with that of the firm to stiff being about 32 degrees. These are the values utilized in the slope stability analyses described below. Slope Stability Analyses Several conditions have been considered in the stability analyses. The first are normal conditions, with Woodland Lake and Lake Delta Crest both at their normal pool elevations, with steady, but controlled, seepage through Woodland Lake dam; the calculated factor of safety for these conditions is greater than the generally accepted value of 1.5. The calculated factor of safety of the next condition, being that described above with earthquake loadings included, is greater than the generally accepted value of 1.0. The last condition is similar to the first described above, with a sudden drawdown of the tailwaters of Lake Delta Crest, such as that which would occur if the dam that forms that lake were to suddenly breach; the calculated factor of safety for this condition is greater than both 2

the 1.2 and the 1.3 values commonly utilized for such loading conditions. It was generally found that due to the relative size of the Woodland Lake dam, with its controlled seepage, the gradual slope of the area between the toe of the Woodland Lake dam and the edge of the tailwaters of Lake Delta Crest, and the relatively shallow depth of Lake Delta Crest in the vicinity of the Woodland Lake dam, rapid draining of the lower lake would actually have minimal effect on the stability of the Woodland Lake dam. Under earthquake conditions, however, localized damage to Woodland Lake dam could occur because of the loss of soil strength of some of the already soft saturated soils of the embankment; catastrophic failure would not be expected, however, with the calculated factor of safety exceeding 1.0 under those conditions. Recommendations Other than the regularly scheduled dam inspections for signs of potential deficiencies, and the continued measurement of water levels in the recently installed piezometers and analysis of the resulting data, no additional analysis of the overall stability of the subject earth dam is recommended at this time. If there are any questions, or if additional information is required, please advise. Respectfully submitted, B & W Engineering Laboratories, Inc. JLW/jw0616 John L. Walton, Sr., P.E. President 3

APPENDIX A BORING LOGS

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 LOG OF BORING Woodland Lake Dam Stability Analysis Job No.: 8654 Woodland Lake Boring: B-1 Eudora, Mississippi Sheet 1 of 1 Boring Location: See Figure Number 1 Ground El: 243.3 feet Boring Depth: 40 feet Date: 09 May 2016 Groundwater Depth: 14 feet at drilling Weather: Clear/Warm Boring Type: Hand Auger/Dynamic Cone Penetration Insp: S. Ikner Number Interval (feet) N - Value Water Content Description 1 1.0-1.5 12+ 23% Stiff Tan Clayey SILT 2 2.0-2.5 12+ 24% Stiff Tan Clayey SILT 3 3.0-3.5 12+ 23% Stiff Tan Clayey SILT 4 4.5-5.0 12+ 26% Stiff Gray Silty CLAY 5 7.0-7.5 3 33% Soft Brown and Tan Clayey SILT 6 9.5-10.0 3 33% Soft Brown and Tan Clayey SILT to 12.0 feet 7 13.0-13.5 12+ 27% Stiff Brown Silty CLAY to 14.0 feet 8 14.5-15.0 3 35% Soft Brown Silty CLAY to 16.5 feet 9 19.5-20.0 12+ 29% Stiff Brown Silty CLAY 10 24.5-25.0 8 32% Firm Brown and Gray Silty CLAY 11 27.0-27.5 10 31% Stiff Gray Silty CLAY 12 29.5-30.0 12+ 28% Stiff Gray Clayey SILT 13 34.5-35.0 12+ 26% Stiff Gray Clayey SILT 14 39.5-40.0 12+ 27% Stiff Gray Clayey SILT

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 LOG OF BORING Woodland Lake Dam Stability Analysis Job No.: 8654 Woodland Lake Boring: B-2 Eudora, Mississippi Sheet 1 of 1 Boring Location: See Figure Number 1 Ground El: 232.8 feet Boring Depth: 25 feet Date: 04-05 May 2016 Groundwater Depth: 10 feet at drilling Weather: Clear/Warm Boring Type: Hand Auger/Dynamic Cone Penetration Insp: D. Lively Number Interval (feet) N - Value Water Content Description 1 1.0-1.5 12+ 26% Stiff Tan Clayey SILT 2 2.0-2.5 8 30% Firm Brown Silty CLAY 3 3.0-3.5 3 30% Soft Brown Silty CLAY 4 4.5-5.0 3 34% Soft Brown Silty CLAY 5 7.0-7.5 3 33% Soft Brown and Tan Silty CLAY 6 9.5-10.0 3 30% Soft Brown and Tan Silty CLAY to 12.0 feet 7 13.0-13.5 8 27% Firm Brown and Gray Silty CLAY 8 14.5-15.0 7 27% Firm Brown Silty CLAY 9 19.5-20.0 10 25% Stiff Gray Clayey SILT 10 24.5-25.0 10 25% Stiff Brown and Gray Silty CLAY

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 LOG OF BORING Woodland Lake Dam Stability Analysis Job No.: 8654 Woodland Lake Boring: B-3 Eudora, Mississippi Sheet 1 of 1 Boring Location: See Figure Number 1 Ground El: 217.7 feet Boring Depth: 20 feet Date: 05 May 2016 Groundwater Depth: 11.5 feet at drilling Weather: Clear/Warm Boring Type: Hand Auger/Dynamic Cone Penetration Insp: D. Lively Number Interval (feet) N - Value Water Content Description 1 1.0-1.5 3 29% Soft Brown and Gray Silty CLAY 2 2.0-2.5 6 33% Firm Brown Silty CLAY 3 3.0-3.5 6 29% Firm Brown and Gray Silty CLAY 4 4.5-5.0 12+ 25% Stiff Gray Clayey SILT 5 7.0-7.5 12+ 27% Stiff Gray Clayey SILT 6 9.5-10.0 12+ 27% Stiff Gray Clayey SILT 7 13.0-13.5 7 26% Firm Gray Clayey SILT 8 14.5-15.0 7 28% Firm Gray Clayey SILT to 16.5 feet 9 19.5-20.0 12+ 29% Stiff Gray Silty CLAY w/trace of Sand

APPENDIX B LABORATORY TEST RESULTS

B & W Engineering Laboratories, Inc. P.O. Box 341091 Memphis, Tennessee 38184-1091 (901) 373-7957 LABORATORY TEST REPORT Slope Stability Analysis Job No.: 8654 Woodland Lake Dam Eudora, Mississippi ATTERBERG LIMITS Boring No. No. Interval Moisture Content LL PL PI Soil Classification B-1 2 2.0-2.5 24% 28 25 3 Clayey SILT, ML B-1 4 4.5-5.0 26% 35 12 12 Silty CLAY, CL B-1 6 9.5-10.0 33% 34 24 10 Silty CLAY, CL B-1 8 14.5-15.0 35% 38 23 15 Silty CLAY, CL B-1 10 24.5-25.0 32% 35 23 12 Silty CLAY, CL B-1 13 34.5-35.0 26% 35 27 17 Clayey SILT, ML B-2 1 1.0-1.5 26% 28 25 3 Clayey SILT, ML B-2 4 4.5-5.0 34% 37 22 15 Silty CLAY, CL B-2 7 13.0-13.5 27% 32 20 12 Silty CLAY, CL B-3 4 4.5-5.0 25% 32 26 6 Clayey SILT, ML B-3 6 9.5-10.0 27% 33 26 7 Clayey SILT, ML